Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Frequency stabilization in injection controlled pulsed CO2 lasers

Longitudinal mode selection by injection has been demonstrated as a viable technique for tailoring a TEA-CO2 laser with pulse energies of a Joule or greater to fit the requirements of a coherent lidar transmitter. Once reliable generation of single-longitudinal-mode (SLM) pulses is obtained, one can study the intrapulse frequency variation and attempt to determine the sources of frequency sweeping, or chirp. These sources include the effect of the decaying plasma, the thermal gradient due to the energy dissipation associated with the laser mechanism itself, and the pressure shift of the center frequency of the laser transition. The use of the positive-branch unstable resonator as an efficient means of coupling a discharge with transverse spatial dimensions of the order of centimeters to an optical cavity mode introduces another concern: namely, what can be done to emphasize transverse mode discrimination in an unstable resonator cavity while maintaining high coupling efficiency. These issues are briefly discussed in the paper, and representative experimental examples are included.

Menzies, Robert T.↗

Frequency stabilization and transverse mode discrimination in injection-seeded unstable resonator TEA CO2 lasers

Longitudinal mode selection by injection has been demonstrated as a viable technique for TEA-CO2 lasers with pulse energies of a Joule or greater. Once reliable generation of single-longitudinal-mode (SLM) pulses is obtained, the characteristics and the causes of intrapulse frequency variation can be studied. These include the effect of the decaying plasma, the thermal gradient due to the energy dissipation associated with the laser mechanism itself, and the pressure shift of the center frequency of the laser transition. The use of the positive-branch unstable resonator as an efficient means of coupling a discharge with large spatial dimensions to an optical cavity mode introduces another concern: namely, what can be done to emphasize transverse mode discrimination in an unstable resonator cavity while maintaining high coupling efficiency. These issues are discussed in this paper, and relevant experimental results are included.

Ancellet, G. M.↗

Receiver Would Control Phasing of a Phased-Array Antenna

In a proposed digital signal-processing technique, a radio receiver would control the phasing of a phased-array antenna to aim the peaks of the antenna radiation pattern toward desired signal sources while aiming the nulls of the pattern toward interfering signal sources. The technique was conceived for use in a Global Positioning System (GPS) receiver, for which the desired signal sources would be GPS satellites and typical interference sources would be terrestrial objects that cause multipath propagation. The technique could also be used to optimize reception in spread-spectrum cellular-telephone and military communication systems. During reception of radio signals in a conventional phased-array antenna system, received signals at their original carrier frequencies are phase-shifted, then combined by analog circuitry. The combination signal is then subjected to down-conversion and demodulation. In a system according to the proposed technique (see figure), the signal received by each antenna would be subjected to down-conversion, spread-spectrum demodulation, and correlation; this processing would be performed separately from, and simultaneously with, similar processing of signals received by the other antenna elements. Following analog down-conversion to baseband, the signals would be digitized, and all subsequent processing would be digital. In the digital process, residual carriers would be removed and each signal would be correlated with a locally generated model pseudorandum-noise code, all following normal GPS procedure. As part of this procedure, accumulated values would be added in software and the resulting signals would be phase-shifted in software by the amounts necessary to synthesize the desired antenna directional gain pattern of peaks and nulls. The principal advantage of this technique over the conventional radio-frequency-combining technique is that the parallel digital baseband processing of the signals from the various antenna elements would be a relatively inexpensive and flexible means for exploiting the inherent multiple-peak/multiple-null aiming capability of a phased-array antenna. In the original intended GPS application, the peaks and nulls could be directed independently for each GPS signal being tracked by the GPS receiver. The technique could also be applied to other code-division multiple-access communication systems.

Dunn, Charles E.↗

The bonding of FeN2, FeCO, and Fe2N2 - Model systems for side-on bonding of CO and N2

Qualitative calculations are performed to elucidate the nature of the side-on interaction of both N2 and CO with a single Fe atom. The systems are found to be quite similar, with bonding leading to an increase in the CO or N2 bond length and a decrease in the vibrational frequency. The CO or N2 stretching modes lead to a large dipole derivative along the metal-ligand bond axis. The populations show an almost identical, large donation from the Fe 3d orbitals into the CO or N2 Pi-asterisk. The larger system Fe2N2 is then considered, with the N2 bridging the Fe2, both parallel and perpendicular to the Fe2 bond axis for two different Fe-Fe distances. For FeN2, the shift in the observed N2 frequency is smaller than observed for the alpha state of N2/Fe(111). The shift in the N2 vibrational frequency increases when the N2 interacts with two Fe atoms, either at the Fe-Fe nearest neighbor distance or at the first layer Fe-Fe distance, when the side-on N2 axis is oriented perpendicular to an Fe-Fe bond.

Bauschlicher, Charles W., Jr.↗

Probing Heterogeneous Charge Distributions at the α-Al 2 O 3 (0001)/H 2 O Interface

Unlike metal or semiconductor electrodes, the surface charge resulting from the protonation or deprotonation of insulating mineral oxides is highly localized and heterogeneous in nature. In this work the Stark active C≡N stretch of potassium thiocyanate is used as a molecular probe of the heterogeneity of the interfacial electrostatic potential at the α-Al 2 O 3 (0001)/H 2 O interface. Vibrational sum frequency generation (vSFG) measurements performed in the OH stretching region suggest that thiocyanate species organize interfacial water similarly to halide ions. Changes in the electrostatic potential are then tracked via Stark shifts of the vibrational frequency of the thiocyanate stretch. Our vSFG measurements show that we can simultaneously measure the vSFG response of SCN – ions experiencing charged and neutral surface sites. We assign local potentials of +308 and -154 mV to positively and negatively charged aluminol groups that are present at pH = 4 and pH = 10, respectively. Thiocyanate anions at positively charged surface sites and negatively charged surface sites and those participating in contact ion pairing adopt similar orientations and are oppositely oriented relative to thiocyanate ions near neutral surface sites. All four species followed Langmuir adsorption isotherms. Density functional theory–molecular dynamics (DFT-MD) simulations of SCN – near the neutral α-Al 2 O 3 (0001)/H 2 O interface show that the vSFG response in the C≡N stretch region originates from a SCN–H–O–Al complex, suggesting the surface site specificity of these experiments. To our knowledge this is the first spectroscopic measurement of local potentials associated with a heterogeneously charged surface. The ability to probe the evolution of local charges in situ could provide vital insight into many industrial, electrochemical, and geochemically relevant interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A PWM Strategy for Cascaded H-bridges to Reduce the Loss Caused by Parasitic Capacitances of Medium Voltage Dual Active Bridge Transformers

In this paper, to reduce the power loss caused by the parasitic capacitances of medium voltage medium frequency transformers in a two-stage dc/ac converter, including a dual active bridge (DAB)-based dc/dc stage and a cascaded H-bridge (CHB)-based dc/ac stage, a PWM strategy is proposed for the dc/ac stage. For each H-bridge, by shifting the high switching frequency to one half-bridge and having the other half-bridge switching at the fundamental frequency of the ac voltage, equivalent frequencies of transformer terminal-to-ground voltages are reduced. As a result, the frequencies of charging and discharging current to the parasitic capacitance are reduced, and therefore the loss caused by the parasitic capacitances is reduced. Compared to the conventional phase-shift PWM, the proposed PWM strategy can reduce the parasitic capacitance loss by about 75%. Experimental test results of one phase in the 13.8 kV/ 100 kW converter prototype are provided to validate the approach.

Li, Haiguo↗

Compensating For Doppler Shift In Laser Instrumentation

Electronic tuning system continually adjusts frequency of tunable diode laser to compensate for Doppler shift caused by motion of transmitter or receiver containing laser. Doppler-shift-compensating system intended primarily for use in transmitter or receiver of laser remote-sensing or communication system to keep frequency of received signal within frequency range of narrow-band-pass filter. By use of narrow-band filter (instead of wide-band filter required in absence of Doppler compensation), signal-to-noise ratio of laser system increased. Thus, less-powerful transmitter usable.

Schwemmer, Geary K.↗

Hydrogen Bonding and Vibrational Spectroscopy: A Theoretical Study

Effects of hydrogen bonding on vibrational spectra are studied for several hydrogen-bonded complexes, in which hydrogen bonding ranges from weak (<5 kcal/mol) to very strong (>25 kcal/mol). The systems studied include complexes of inorganic acids and salts with water and ammonia, as well as complexes of several organic molecules (nitriles and amino acids) with water. Since anharmonic effects are very strong in hydrogen-bonded systems, anharmonic vibrational frequencies and infrared intensities are computed using the correlation-corrected vibrational self-consistent field (CC-VSCF) method with ab initio potential surfaces at the MP2 and CCSD(T) levels. The most common spectral effects induced by hydrogen bonding are red shifts of stretching vibrational frequencies ranging from approx.200/cm to over 2000/cm and significant increases of infrared intensities for those bonds that participate in hydrogen bonding. However, some systems (e.g. nitrile-water complexes) exhibit shifts in the opposite direction (to the blue) upon formation of hydrogen bonds.

Chaban, Galina M.↗

Resonant Doppler velocimeter

A technique is presented for visualizing and quantitatively measuring velocity, temperature, and pressure by shining a single frequency laser beam into a gaseous flow which is seeded with an atomic species. The laser is tuned through the absorption frequencies of the seeded species and the absorption profile is detected by observing fluorescence as the atoms relax back to the ground state. The flow velocity is determined by observing the Doppler shift in the absorption frequency. Spectroscopic absorption line broadening mechanisms furnish information regarding the static temperature and pressure of the moving gas. Results of experiments conducted in the free stream and in the bow shock of a conical model mounted in a hypersonic wind tunnel indicate that the experimental uncertainties in the measurement of average values for the velocity, temperature and pressure of the flow are 0.1, 5 and 10 percent respectively.

Zimmermann, M.↗

Spread-Spectrum Carrier Estimation With Unknown Doppler Shift

We present a method for the frequency estimation of a BPSK modulated, spread-spectrum carrier with unknown Doppler shift. The approach relies on a classic periodogram in conjunction with a spectral matched filter. Simulation results indicate accurate carrier estimation with processing gains near 40. A DSP-based prototype has been implemented for real-time carrier estimation for use in New Mexico State University's proposal for NASA's Demand Assignment Multiple Access service.

DeLeon, Phillip L.↗

Two-phase charge-coupled device

A charge-transfer efficiency of 99.99% per stage was achieved in the fat-zero mode of operation of 64- and 128-stage two-phase charge-coupled shift registers at 1.0-MHz clock frequency. The experimental two-phase charge-coupled shift registers were constructed in the form of polysilicon gates overlapped by aluminum gates. The unidirectional signal flow was accomplished by using n-type substrates with 0.5 to 1.0 ohm-cm resistivity in conjunction with a channel oxide thickness of 1000 A for the polysilicon gates and 3000 A for the aluminum gates. The operation of the tested shift registers with fat zero is in good agreement with the free-charge transfer characteristics expected for the tested structures. The charge-transfer losses observed when operating the experimental shift registers without the fat zero are attributed to fast interface state trapping. The analytical part of the report contains a review backed up by an extensive appendix of the free-charge transfer characteristics of CCD's in terms of thermal diffusion, self-induced drift, and fringing field drift. Also, a model was developed for the charge-transfer losses resulting from charge trapping by fast interface states. The proposed model was verified by the operation of the experimental two-phase charge-coupled shift registers.

Kosonocky, W. F.↗

Fiber-optic rotation sensors

Possible approaches to the design of fiber optic inertial frame rotation sensors based on the Sagnac effect are reviewed under two general categories: (1) single frequency interferometers which generate a phase shift proportional to inertial rotation rate, and (2) dual frequency interferometers for which the beat frequency is proportional to rotation rate. The principal variations within the single frequency class involve the way in which the nonreciprocal phase bias is used and techniques for generating the nonreciprocal bias. Within the dual frequency class, the various approaches differ principally in the way in which the counter-circulating frequencies are established.

Goss, W. C.↗

Carrier Estimation Using Classic Spectral Estimation Techniques for the Proposed Demand Assignment Multiple Access Service

In any satellite communication, the Doppler shift associated with the satellite's position and velocity must be calculated in order to determine the carrier frequency. If the satellite state vector is unknown then some estimate must be formed of the Doppler-shifted carrier frequency. One elementary technique is to examine the signal spectrum and base the estimate on the dominant spectral component. If, however, the carrier is spread (as in most satellite communications) this technique may fail unless the chip rate-to-data rate ratio (processing gain) associated with the carrier is small. In this case, there may be enough spectral energy to allow peak detection against a noise background. In this thesis, we present a method to estimate the frequency (without knowledge of the Doppler shift) of a spread-spectrum carrier assuming a small processing gain and binary-phase shift keying (BPSK) modulation. Our method relies on an averaged discrete Fourier transform along with peak detection on spectral match filtered data. We provide theory and simulation results indicating the accuracy of this method. In addition, we will describe an all-digital hardware design based around a Motorola DSP56303 and high-speed A/D which implements this technique in real-time. The hardware design is to be used in NMSU's implementation of NASA's demand assignment, multiple access (DAMA) service.

Scaife, Bradley James↗

Prevalence of Self-Reported Voice Concerns and Associated Risk Markers in a Nonclinical Sample of Military Service Members

Introduction: Difficult communication environments are common in military settings, and effective voice use can be critical to mission success. This study aimed to estimate the prevalence of self-reported voice disorders among U.S. military service members and to identify factors that contribute to their voice concerns. Method: A nonclinical sample of 4,123 active-duty service members was recruited across Department of Defense hearing conservation clinics. During their required annual hearing evaluation, volunteers provided responses to voice-related questions including a slightly adapted version of the Voice Handicap Index-10 (VHI-10) as part of a larger survey about communication issues. Changepoint detection was applied to age and years of service to explore cohort effects in the reporting of voice concerns. Logistic regression analyses examined multiple available factors related to communication to identify factors associated with abnormal results on the VHI-10. Results: Among the respondents, 41% reported experiencing vocal hoarseness or fatigue at least several times per year, and 8.2% ( n = 336) scored above the recommended abnormal cut-point value of 11 on the VHI-10. Factors independently associated with the greatest risk for self-reported voice concerns were sex (female), cadmium exposure, vocal demands (the need for a strong, clear voice), and auditory health measures (frequency of experiencing temporary threshold shifts; self-reported hearing difficulties). Conclusions: Based on self-reported voice concerns and false negative rates reported in the literature, the prevalence of dysphonia in a large sample of active-duty service members is estimated to be 11.7%, which is higher than that in the general population. Certain predictors for voice concerns were expected based on previous literature, like female sex and voice use, but frequency of temporary threshold shifts and exposure to cadmium were surprising. The strong link between voice and auditory problems has particular implications regarding the need for effective communication in high-noise military and other occupational environments.

Audiology & Speech-Language Pathology↗

Observations of gravity waves in the mesosphere with the MU radar

Wind motions were observed at 60 to 90 km altitudes with the MU radar during daylight hours (0800 to 1600 LT) from 13 to 31 October 1986. Quasi-monochromatic gravity waves were evident on 16 of the 19 days of observations. They were characterized by typical vertical wavelength of 5 to 15 km and intrinsic periods centered at about 9 hours. The propagation direction of the gravity waves, determined by the gravity wave dispersion relation, was mostly equatorward. The vertical wave number spectra of the horizontal components of the mesoscale wind fluctuations are explained well by saturated gravity wave theory. The frequency spectrum of vertical wind component has a slope of + 1/3, while the oblique spectra have a slope of -5/3 up to 4 x 10(-3) (c/s); these agree fairly well with model gravity wave spectra. Doppler shift effects on the frequency spectra are recognized at higher frequencies. Upward flux was determined of horizontal momentum flux induced by waves with periods from 10 min to 8 hours, and westward and northward body forces of 5.1 and 4.0 m/s/day, were estimated respectively.

Tsuda, T.↗

Summary Abstract: Vibrations of Ammonia on the Cu (100) Surface

Recently, the TR frequencies for NH3 molecularly adsorbed on Cu(100) have been measured by infrared laser-induced photodesorption using a tunable laser operating in the group frequency range. Additionally, photodesorption, photo-fragmentation, and photoionization has been observed using a CO2 laser in the 10 microns range. In this contribution we report on work in progress where we use quantum chemical methods to analyze the shifts in the NH, frequencies relative to the gas phase upon chemisorption. We also compute the Cu- N stretch vibration, which has been observed experimentally,and the change in the IR intensities associated with chemisorption; this change is insufficient by itself to explain the increased photoionization efficiency observed.

Pettersson, Lars G. M.↗

Cardiovascular regulation in humans in response to oscillatory lower body negative pressure

The frequency response characteristics of human cardiovascular regulation during hypotensive stress have not been determined. We therefore exposed 10 male volunteers to seven frequencies (0.004-0.1 Hz) of oscillatory lower body negative pressure (OLBNP; 0-50 mmHg). Fourier spectra of arterial pressure (AP), central venous pressure (CVP), stroke volume (SV), cardiac output (CO), heart rate (HR), and total peripheral resistance (TPR) were determined and first harmonic mean, amplitude, and phase angles with respect to OLBNP are presented. AP was relatively well regulated as demonstrated by small oscillations in half amplitude (3.5 mmHg) that were independent of OLBNP frequency and similar to unstressed control spectra. Due to the biomechanics of the system, the magnitudes of oscillations in calf circumference (CC) and CVP decreased with increasing frequency; therefore, we normalized responses by these indexes of the fluid volume shifted. The ratios of oscillations in AP to oscillations in CC increased by an order of magnitude, whereas oscillations in CVP to oscillations in CC and oscillations in AP to oscillations in CVP both tripled between 0.004 and 0.1 Hz. Therefore, even though the amount of fluid shifted by OLBNP decreased with increasing frequency, the magnitude of both CVP and AP oscillations per volume of fluid shifted increased (peaking at 0.08 Hz). The phase relationships between variables, particularly the increasing lags in SV and TPR, but not CVP, indicated that efferent responses with lags of 5-6 s could account for the observed responses. We conclude that, at frequencies below 0.02 Hz, the neural system of humans functioned optimally in regulating AP; OLBNP-induced decreases in SV (by as much as 50%) were counteracted by appropriate oscillations in HR and TPR responses. As OLBNP frequency increased, SV, TPR, and HR oscillations increasingly lagged the input and became less optimally timed for AP regulation.

NASA Discipline Cardiopulmonary↗

YBCO superconducting ring resonators at millimeter-wave frequencies

Microstrip ring resonators operating at 35 GHz were fabricated from laser ablated YBCO films deposited on lanthanum aluminate substrates. They were measured over a range of temperatures and their performances compared to identical resonators made of evaporated gold. Below 60 Kelvin the superconducting strip performed better than the gold, reaching an unloaded Q approximately 1.5 times that of gold at 25 K. A shift in the resonant frequency follows the form predicted by the London equations. The Phenomenological Loss Equivalence Method is applied to the ring resonator and the theoretically calculated Q values are compared to the experimental results.

Chorey, Christopher M.↗