Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “foams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Sculpting Non-Machinable Porous Materials

The goal of this project was to establish the scientific basis for subtractive manufacturing (sculpting) of porous materials using ion beams. Using the catcher foil technique, complemented with molecular dynamics simulations, we studied the dependence of the sputtering yield of Ag and Au nanofoams as a function of foam monolith density, ion mass, and the beam incidence angle, and compared these dependencies to those measured for full-density solids. We found that the foam sputtering yield was considerably lower than for the full-density solid. The sputtering yield increased with beam incidence angle, and the open structure of the foam suppressed the development of collision cascades. We also found that the sputtering yield decreased with increasing foam density. The simulation revealed a significant redeposition of sputtered atoms in the foam.

36 MATERIALS SCIENCE↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

The Savannah River National Laboratory (SRNL) was requested to develop a new antifoam control method for the Defense Waste Processing Facility’s (DWPF) Chemical Process Cell (CPC). SRNL completed testing of both chemical and nonchemical foam controls. The nonchemical foam controls were either ineffective (or worse, created more foam) or impractical (i.e., a water spray can control foam, but excessive water is needed). As a result, the focus of this study was on finding a superwetter or commercial antifoam for controlling foam.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

The Savannah River National Laboratory (SRNL) was requested to develop a new antifoam control method for the Defense Waste Processing Facility’s (DWPF) Chemical Process Cell (CPC). SRNL completed testing of both chemical and nonchemical foam controls. The nonchemical foam controls were either ineffective (or worse, created more foam) or impractical (i.e., a water spray can control foam, but excessive water is needed). As a result, the focus of this study was on finding a superwetter or commercial antifoam for controlling foam.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

The Savannah River National Laboratory (SRNL) was requested to develop a new antifoam control method for the Defense Waste Processing Facility’s (DWPF) Chemical Process Cell (CPC). SRNL completed testing of both chemical and nonchemical foam controls. The nonchemical foam controls were either ineffective (or worse, created more foam) or impractical (i.e., a water spray can control foam, but excessive water is needed). As a result, the focus of this study was on finding a superwetter or commercial antifoam for controlling foam.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Additive Manufacturing Evaporative Casting

Traditional lost foam casting has been around for decades. The process uses foam forms blown by an injection molding like process or CNC milled into the desired shape, then pouring molten metal over the foam pattern to create a metallic object. Additive Manufacturing Evaporative Casting (AMEC) is a new process that eliminates foam forms by using additive manufacturing to 3D print the desired cast geometry. This not only saves time and money but allows for more advanced and complex designs that can’t be achieved by carving foam. Additionally, AMEC doesn’t require molds and tooling like other casting and foundry options. Because the AMEC process is new, extensive testing is needed to develop a better understanding of the process to minimize defects, quantify material properties, and start computer modeling for the process. This CRADA (collaborative research and development agreement) between ORNL and Skuld seeks to improve the process, develop a computational model, characterize material properties, and explore new applications.

36 MATERIALS SCIENCE↗

A method for reducing ground reflection effects from acoustic measurements

The method involved placing foam blocks on the ground between sound source and receiver in an approximation of the wedges in an anechoic chamber. The tests were performed out of doors as a function of the receiver height and source-receiver separation distance. The spacing between blocks and the extent of ground covered were varied to estimate the optimum placement and minimum amount of foam treatment needed. Base-line tests without foam were also performed. It was found that the foam treatment reduced the amplitude of the peaks and valleys in the sound pressure spectra substantially. The foam was least effective at low frequency, especially for the low receiver height and for large source-receiver distances. Results from the base-line tests were compared with theoretically predicted results. These base-line test results were in reasonable agreement with those from theory.

Noerager, J. A.↗

The effect of changes in the USF/NASA toxicity screening test method on data from some cellular polymers

Rankings of relative toxicity can be markedly affected by changes in test variables. Revision of the USF/NASA toxicity screening test procedure to eliminate the connecting tube and supporting floor and incorporate a 1.0 g sample weight, 200 C starting temperature, and 800 C upper limit temperature for pyrolysis, reversed the rankings of flexible polyurethane and polychloroprene foams, not only in relation to each other, but also in relation to cotton and red oak. Much of the change is attributed to reduction of the distance between the sample and the test animals, and reduction of the sample weight charged. Elimination of the connecting tube increased the relative toxicity of the polyurethane foams. The materials tested were flexible polyurethane foam, without and with fire retardant; rigid polyurethane foam with fire retardant; flexible polychloroprene foam; cotton, Douglas fir, red oak, hemlock, hardboard, particle board, polystyrene, and polymethyl methacrylate.

Hilado, C. J.↗

External insulator for liquid hydrogen tanks

With optimized insulation thickness, tank temperatures were always below 311 K (100 F). This conclusion indicated that an aluminum tank could be used with an optimized insulation system if desired. The N2 purged systems were always lighter than CO2 purged systems. The lower condensation temperature was the controlling factor. Closed cell foam systems were lightest. Closed cell foams, in spite of their need for protective outer insulation, produced insulation systems which were lighter than systems which allowed cryodeposition. Foam system durability established for TMAX = 316 K (110 F). Tests for a subsonic application established this durability; higher temperature limit foam durability was unknown at this. An increase in foam TMAX from 316 K (110 F) to 450 K (350 F) potentially decreased TPS mass by 25 percent.

Sharpe, E. L.↗

Thermally stable polyimide components for space and commercial applications

The properties and applications of the thermally stable polyimide foams are discussed, together with an investigation of the methods for producing these materials. The qualities of the polyimide foams such as resistance to fire, not emitting smoke below 204 C, not producing incapacitating toxic by-products below 204 C, and resiliency and flexibility from minus 184 C to 315 C are stressed. The thermal, dielectric, induction, and microwave heating methods are discussed, particularly in relation to producing flexible resilient foams, thermal acoustical polyimide foams, and polyimide foam structural materials. It is concluded that the microwave approach shows to be a viable concept for generating flexible, low density cellular materials possessing a homogeneous structure and applicable to the aerospace industry and for commercial uses.

Gagliani, J.↗

Non-linear properties of metallic cellular materials with a negative Poisson's ratio

Negative Poisson's ratio copper foam was prepared and characterized experimentally. The transformation into re-entrant foam was accomplished by applying sequential permanent compressions above the yield point to achieve a triaxial compression. The Poisson's ratio of the re-entrant foam depended on strain and attained a relative minimum at strains near zero. Poisson's ratio as small as -0.8 was achieved. The strain dependence of properties occurred over a narrower range of strain than in the polymer foams studied earlier. Annealing of the foam resulted in a slightly greater magnitude of negative Poisson's ratio and greater toughness at the expense of a decrease in the Young's modulus.

Choi, J. B.↗

Testing Microgravity Flight Hardware Concepts on the NASA KC-135

This paper provides an overview of utilizing the NASA KC-135 Reduced Gravity Aircraft for the Foam Optics and Mechanics (FOAM) microgravity flight project. The FOAM science requirements are summarized, and the KC-135 test-rig used to test hardware concepts designed to meet the requirements are described. Preliminary results regarding foam dispensing, foam/surface slip tests, and dynamic light scattering data are discussed in support of the flight hardware development for the FOAM experiment.

Motil, Susan M.↗

Material Modeling of Space Shuttle Leading Edge and External Tank Materials For Use in the Columbia Accident Investigation

Upon the commencement of the analytical effort to characterize the impact dynamics and damage of the Space Shuttle Columbia leading edge due to External Tank insulating foam, the necessity of creating analytical descriptions of these materials became evident. To that end, material models were developed of the leading edge thermal protection system, Reinforced Carbon Carbon (RCC), and a low density polyurethane foam, BX-250. Challenges in modeling the RCC include its extreme brittleness, the differing behavior in compression and tension, and the anisotropic fabric layup. These effects were successfully included in LS-DYNA Material Model 58, *MAT_LAMINATED_ COMPOSITE_ FABRIC. The differing compression and tension behavior was modeled using the available damage parameters. Each fabric layer was given an integration point in the shell element, and was allowed to fail independently. Comparisons were made to static test data and coupon ballistic impact tests before being utilized in the full scale analysis. The foam's properties were typical of elastic automotive foams; and LS-DYNA Material Model 83, *MAT_FU_CHANG_FOAM, was successfully used to model its behavior. Material parameters defined included strain rate dependent stress-strain curves for both loading and un-loading, and for both compression and tension. This model was formulated with static test data and strain rate dependent test data, and was compared to ballistic impact tests on load-cell instrumented aluminum plates. These models were subsequently utilized in analysis of the Shuttle leading edge full scale ballistic impact tests, and are currently being used in the Return to Flight Space Shuttle re-certification effort.

Carney, Kelly↗

Characterization of Space Shuttle External Tank Thermal Protection System (TPS) Materials in Support of the Columbia Accident Investigation

NASA suffered the loss of the seven-member crew of the Space Shuttle Columbia on February 1, 2003 when the vehicle broke apart upon re-entry to the Earth's atmosphere. The final report of the Columbia Accident Investigation Board (CAIB) determined that the accident was caused by a launch ascent incident-a suitcase-sized chunk of insulating foam on the Shuttle's External Tank (ET) broke off, and moving at almost 500 mph, struck an area of the leading edge of the Shuttle s left wing. As a result, one or more of the protective Reinforced Carbon-Carbon (RCC) panels on the wing leading edge were damaged. Upon re-entry, superheated air approaching 3,000 F breached the wing damage and caused the vehicle breakup and loss of crew. The large chunk of insulating foam that broke off during the Columbia launch was determined to come from the so-called bipod ramp area where the Shuttle s orbiter (containing crew) is attached to the ET. Underneath the foam in the bipod ramp area is a layer of TPS that is a cork-filled silicone rubber composite. In March 2003, the NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama received cured samples of the foam and composite for testing from the Michoud Assembly Facility (MAF) in New Orleans, Louisiana. The MAF is where the Shuttle's ET is manufactured. The foam and composite TPS materials for the ET have been well characterized for mechanical property data at the super-cold temperatures of the liquid oxygen and hydrogen fuels used in the ET. However, modulus data on these materials is not as well characterized. The TA Instruments 2980 Dynamic Mechanical Analyzer (DMA) was used to determine the modulus of the two TPS materials over a range of -145 to 95 C in the dual cantilever bending mode. Multi-strain, fixed frequency DMA tests were followed by multi-frequency, fixed strain tests to determine the approximate bounds of linear viscoelastic behavior for the two materials. Additional information is included in the original extended abstract.

Wingard, Charles D.↗

The Effect of Sensory Noise Created by Compliant and Sway-Referenced Support Surfaces on Postural Stability

The purpose of the present experiment was to compare in normal human subjects the differential effects on postural stability of introducing somatosensory noise via compliant and/or sway-referenced support surfaces during quiet standing. The use of foam surfaces (two thicknesses: thin (0.95cm) and thick (7.62cm)) and sway-referenced support allowed comparison between two different types of destabilizing factors that increased ankle/foot somatosensory noise. Under some conditions neck extensions were used to increase sensory noise by deviating the vestibular system from its optimal orientation for balance control. The impact of these conditions on postural control was assessed through objective measures of instability. Thick foam and sway-referenced support conditions generated comparable instability in subjects, as measured by equilibrium score and minimum time-to-contact. However, simultaneous application of the conditions resulted in greater instability, suggesting a higher level of generated sensory noise and thus, different receptor types affected during each manipulation. Indeed, sway-referenced support generated greater anterior-posterior center-of-mass (COM) sway, while thick foam generated greater medio-lateral COM sway and velocity. Neck extension had minimal effect on postural stability until combined with simultaneous thick foam and sway-referenced support. Thin foam never generated enough sensory noise to affect postural stability even with noise added by sway-reference support or neck extension. These results provide an interesting window into the central integration of redundant sensory information and indicate the postural impact of sensory inputs is not solely based on their existence, but also their level of noise.

Forth, Katharine E.↗

Post Test Evaluation of HSCT Nozzle Acoustic Liner Subcomponents Subjected to a Hot Acoustic Durability Test

The acoustic liner system designed for use in the High Speed Civil Transport (HSCT) was tested in a thermal-acoustic environment. Five ceramic matrix composite (CMC) acoustic tile configurations, five bulk acoustic absorbers, and one thermal protection system design were tested. The CMC acoustic tiles were subjected to two 2 3/4 hr ambient temperature acoustic exposures to measure their dynamic response. One exposure was conducted on the tiles alone and the second exposure included the tiles and the T-foam bulk absorber. The measured tile RMS strains were small. With or without the T-foam absorber, the dynamic strains were below strain levels that would cause damage during fatigue loading. After the ambient exposure, a 75-hr durability test of the entire acoustic liner system was conducted using a thermal-acoustic cycle that approximated the anticipated service cycle. Acoustic loads up to 139 dB/Hz and temperatures up to 1670 F (910 C) were employed during this 60 cycle test. During the durability test, the CMC tiles were exposed to temperatures up to 1780 F and a transient through thickness gradient up to 490 F. The TPS peak temperatures on the hot side of the panels ranged from 750 to 1000 F during the 60 cycles. The through thickness delta T ranged from 450 to 650 F, varying with TPS location and cycle number. No damage, such as cracks or chipping, was observed in the CMC tiles after completion of the testing. However, on tile warped during the durability test and was replaced after 43 or 60 cycles. No externally observed damage was found in this tile. No failure of the CMC fasteners occurred, but damage was observed. Cracks and missing material occurred, only in the fastener head region. No indication of damage was observed in the T-foam acoustic absorbers. The SiC foam acoustic absorber experienced damage after about 43 cycles. Cracking in the TPS occurred around the attachment holes and under a vent. In spite of the development of damage, the TPS maintained its insulative capability throughout the durability test. The durability test results demonstrate damage-tolerant CMC tile, CMC fastener, TPS, and T-foam absorber designs for the combined thermal and acoustic engine nozzle environment.

Verrilli, Michael J.↗

Determination of Time Required for Materials Exposed to Oxygen to Return to Reduced Flammability

Increased material flammability due to exposure to high oxygen concentrations is a concern from both a safety and operational perspective. Localized, high oxygen concentrations can occur when exiting a higher oxygen concentration environment due to material saturation, as well as oxygen entrapment between barrier materials. Understanding of oxygen diffusion and permeation and its correlation to flammability risks can reduce the likelihood of fires while improving procedures as NASA moves to longer missions with increased extravehicular activities in both spacecraft and off-Earth habitats. This paper examines the time required for common spacecraft materials exposed to oxygen to return to reduced flammability after removal from the increased oxygen concentration environment. Specifically, NASA-STD-6001A maximum oxygen concentration testing and ASTM F-1927 permeability testing were performed on Nomex 4 HT90-40, Tiburon 5 Surgical Drape, Cotton, Extravehicular Mobility Unit (EMU) Liquid-Cooled Ventilation Garment, EMU Thermal Comfort Undergarment, EMU Mosite Foam with Spandex Covering, Advanced Crew Escape Suit (ACES) Outer Cross-section, ACES Liquid Cooled Garment (LCG), ACES O2 Hose Material, Minicel 6 Polyethylene Foam, Minicel Polyethylene Foam with Nomex Covering, Pyrell Polyurethane Foam, and Zotek 7 F-30 Foam.

Harper, Susana↗

Grounding Headphones for Protection Against ESD

A simple alternative technique has been devised protecting delicate equipment against electrostatic discharge (ESD) in settings in which workers wear communication headsets. In the original setting in which the technique was devised, the workers who wear the headsets also wear anti-ESD grounding straps on their wrists. The alternative technique eliminates the need for the wrist grounding straps by providing for grounding through the headsets. In place of the electrically insulating foam pads on the headsets, one installs pads made of electrically conductive foam like that commonly used to protect electronic components. Grounding wires are attached to the conductive foam pads, then possibly to the shielding cable which may be grounded to the backshell on the connector. The efficacy of this technique in protecting against ESD has been verified in experiments. The electrical resistance of the pads is a few megohms - about the same as that of a human body between the fingers of opposite hands and, hence, low enough for grounding. The only drawback of the technique is that care must be taken to place the foam pads in contact with the user s skin: any hair that comes between the foam pads and the skin must be pushed aside because hair is electrically insulating and thus prevents adequate grounding.

Peters, John↗

Cryogenic Temperature-Gradient Foam/Substrate Tensile Tester

The figure shows a fixture for measuring the tensile strength of the bond between an aluminum substrate and a thermally insulating polymeric foam. The specimen is meant to be representative of insulating foam on an aluminum tank that holds a cryogenic liquid. Prior to the development of this fixture, tensile tests of this type were performed on foam/substrate specimens immersed in cryogenic fluids. Because the specimens were cooled to cryogenic temperatures throughout their thicknesses, they tended to become brittle and to fracture at loads below true bond tensile strengths. The present fixture is equipped to provide a thermal gradient from cryogenic temperature at the foam/substrate interface to room temperature on the opposite foam surface. The fixture includes an upper aluminum block at room temperature and a lower aluminum block cooled to -423 F (approx. -253 C) by use of liquid helium. In preparation for a test, the metal outer surface (the lower surface) of a foam/substrate specimen is bonded to the lower block and the foam outer surface (the upper surface) of the specimen is bonded to the upper block. In comparison with the through-the-thickness cooling of immersion testing, the cryogenic-to-room-temperature thermal gradient that exists during testing on this fixture is a more realistic approximation of the operational thermal condition of sprayed insulating foam on a tank of cryogenic liquid. Hence, tensile tests performed on this fixture provide more accurate indications of operational bond tensile strengths. In addition, the introduction of the present fixture reduces the cost of testing by reducing the amount of cryogenic liquid consumed and the time needed to cool a specimen.

Vailhe, Christophe↗