Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Air turbulence characteristics at multiple sites in and above the Amazon rainforest canopy

Atmospheric turbulence characteristics within and above rain forest canopies are investigated at several sites located in the Amazon region of Brazil. Turbulence data provided by bi- and three-dimensional sonic anemometers, which were deployed at heights ranging from near the forest floor to about 80 m, are analyzed to describe the principal features of atmospheric turbulence, sensible heat flux (H), and components of the turbulent kinetic energy (TKE) budget equation. The analyses focused on weak (WW) and strong (SW) wind conditions to achieve the research objectives of evaluating the turbulence structure above and below the rain forest canopy and estimating the degree of coupling between air layers above the forest and deep in the canopy. Turbulence statistical moments show that atmospheric eddies, generated above the canopy, hardly penetrate the region below 0.5h (h is the canopy height). Forest-atmosphere exchanges of heat differ depending on the observed wind regimes. Sensible heat fluxes decrease with canopy depth for SW conditions and are approximately constant with the height for WW above the canopy. Sensible heat flux profiles reveal a transition layer (around 0.6h) which sometimes exchanges heat with the upper and sometimes with the lower forest canopy, depending on time of day and weather conditions. TKE balance results show that during the daytime period in SW conditions the shear production is at least an order of magnitude greater than the buoyancy above the forest canopy. This turbulence, however, is practically all dissipated in the region above 0.5h. Thus, the air layer from the soil surface to 0.5h is largely decoupled from the upper part of the forest canopy. This feature of having the bottom of the canopy mostly decoupled from the air aloft in the dense and tall rain forest can exert control on the residence times and turbulent transport of plant-emitted gases out of the forest canopy.

54 ENVIRONMENTAL SCIENCES↗

Validation of hydrogen gas stratification and mixing models

Two validation benchmarks confirm that the BMIX++ code is capable of simulating unintended hydrogen release scenarios efficiently. The BMIX++ (UC Berkeley mechanistic MIXing code in C++) code has been developed to accurately and efficiently predict the fluid mixture distribution and heat transfer in large stratified enclosures for accident analyses and design optimizations. The BMIX++ code uses a scaling based one-dimensional method to achieve large reduction in computational effort compared to a 3-D computational fluid dynamics (CFD) simulation. Two BMIX++ benchmark models have been developed. One is for a single buoyant jet in an open space and another is for a large sealed enclosure with both a jet source and a vent near the floor. Both of them have been validated by comparisons with experimental data. Excellent agreements are observed. The entrainment coefficients of 0.09 and 0.08 are found to fit the experimental data for hydrogen leaks with the Froude number of 99 and 268 best, respectively. In addition, the BIX++ simulation results of the average helium concentration for an enclosure with a vent and a single jet agree with the experimental data within a margin of about 10% for jet flow rates ranging from 1.21 × 10⁻⁴ to 3.29 × 10⁻⁴ m³/s. In conclusion, computing time for each BMIX++ model with a normal desktop computer is less than 5 min.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electric load shape benchmarking for small- and medium-sized commercial buildings

Small- and medium-sized commercial buildings owners and utility managers often look for opportunities for energy cost savings through energy efficiency and energy waste minimization. However, they currently lack easy access to low-cost tools that help interpret the massive amount of data needed to improve understanding of their energy use behaviors. Benchmarking is one of the techniques used in energy audits to identify which buildings are priorities for an energy analysis. Traditional energy performance indicators, such as the energy use intensity (annual energy per unit of floor area), consider only the total annual energy consumption, lacking consideration of the fluctuation of energy use behavior over time, which reveals the time of use information and represents distinct energy use behaviors during different time spans. To fill the gap, this study developed a general statistical method using 24-hour electric load shape benchmarking to compare a building or business/tenant space against peers. Specifically, the study developed new forms of benchmarking metrics and data analysis methods to infer the energy performance of a building based on its load shape. We first performed a data experiment with collected smart meter data using over 2,000 small- and medium-sized businesses in California. We then conducted a cluster analysis of the source data, and determined and interpreted the load shape features and parameters with peer group analysis. Finally, we implemented the load shape benchmarking feature in an open-access web-based toolkit (the Commercial Building Energy Saver) to provide straightforward and practical recommendations to users. The analysis techniques were generic and flexible for future datasets of other building types and in other utility territories.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heterogeneity or illusion? Track the carbon Kuznets curve of global residential building operations

Residential buildings, the “last mile” sector in the global decarbonization, have become the most significant uncertain factor hindering carbon neutrality with increasing household energy demand. To track the operational carbon in buildings, this study investigates the carbon Kuznets curve (CKC) and the corresponding decoupling status of residential building operations at four emission scales by using the data of 30 countries from 2000 to 2019. The results show that (1) the CKC model can fit more than half of the samples. Most curves have an inverted U-shape, with 76% of emission per household and 82% of total emissions. (2) In the presence of the CKC, over four-fifths of global residential buildings peak regardless of any emission scale. The analysis denotes that the carbon emissions of developed countries reach their peaks earlier. In the total emissions, the samples’ peaking proportion is 20% and 25% with income per capita < 20,000 United States dollars (USD) and 20,000–40,000 USD, respectively. (3) The Tapio decoupling analysis and the threshold regression effectively verify the robustness and the heterogeneity of CKCs, respectively. Strong decoupling effects of CKCs in most countries are demonstrated at the scales of emission per floor space and the total emissions, and the heterogeneity proves the classic inverted U-shaped relationship between economy and emissions doesn’t exist in all emitters. Overall, this study tracks the historical carbon emission trajectories of residential building operations at a global scale, providing reference for different economies to simulate the dynamic of building carbon emissions along with the economic booming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing peak electricity demand for U.S. households: an assessment of end-use loads and demand factors

Understanding household peak electricity demand is critical to evaluate the technical need for electrical infrastructure upgrades. This study characterizes peak loads for existing and new equipment using metered data from a convenience sample of 11,940 U.S. dwellings from four sources, including 911 from two sources with end-use metering. After standardized data cleaning and labeling, we derived descriptive statistics for key metrics, such as maximum demand and demand factors, and developed predictive models relating 60- to 15-min demand for the National Electrical Code (NEC). Mean 15-min maximum demand was 9.7 kW (median 9.0 kW; IQR 7.0–11.5 kW, 95% CI 9.6–9.8 kW), indicating spare capacity in 98% of homes with hypothetical 100 A panels. Maximum demand increased with floor area and number of high-demand loads. Dwelling maximum demand was driven by higher-power, longer-duration heating appliances and vehicle charging, while most user-operated appliances contributed little. Demand factors are used to account for how most devices contribute less than their rated power to maximum demand. Existing load mean demand factors (28%; median 10%; IQR 0–58%; CI 28–29%) were higher than those for new loads (21%; median 7%; IQR 0–35%; CI 20–21%), because new loads changed the timing and magnitude of maximum demand. New high-demand loads had higher than average demand factors (40–60%). Whole dwelling demand factors support the NEC's 40% assumption, but they challenge its conservative 100% treatment of new HVAC. We propose a data-driven 50% demand factor for new equipment, which would align with metered data, improve affordability, and modernize electrical codes.

Appliances↗

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation↗

Mercury emission from terrestrial background surfaces in the eastern USA. Part I: Air/surface exchange of mercury within a southeastern deciduous forest (Tennessee) over one year

This study focused on the development of a seasonal data set of the Hg air/surface exchange over soils associated with low Hg containing surfaces in a deciduous forest in the southern USA. Data were collected every month for 11 months in 2004 within Standing Stone State Forest in Tennessee using the dynamic flux chamber method. Mercury air/surface exchange associated with the litter covered forest floor was very low with the annual mean daytime flux being 0.4 0.5 ng m-2 h-1 (n = 301). The daytime Hg air/surface exchange over the year oscillated between emission (81% of samples with positive flux) and deposition (19% of samples with negative flux). A seasonal trend of lower emission in the spring and summer (closed canopy) relative to the fall and winter (open canopy) was observed. Correlations were found between the air/surface exchange and certain environmental factors on specific days sampled but not collectively over the entire year. The very low magnitude of Hg air/surface exchange as observed in this study suggests that an improved methodology for determining and reporting emission fluxes is needed when the values of fluxes and chamber blanks are both very low and comparable. This study raises questions and points to a need for more research regarding how to scale the Hg air/surface exchange for surfaces with very low emissions.

54 ENVIRONMENTAL SCIENCES↗

An update on the natural sources and sinks of atmospheric mercury

This paper summarizes recent advances in the understanding of the exchange of Hg between the atmosphere and natural terrestrial surfaces including substrates (soil, rocks, litter-covered surfaces and weathered lithological material) and foliage. Terrestrial landscapes may act as new sources of atmospheric Hg, and as repositories or temporary residences for anthropogenically and naturally derived atmospheric Hg. The role of terrestrial surfaces as sources and sinks of atmospheric Hg must be quantified in order to develop regional and global Hg mass balances, and to assess the efficacy of regulatory controls on anthropogenic point sources in reduction of human Hg exposure. Continued field research has allowed for refinement of emission estimates for geothermal and volcanic, and Hg mineralized areas in the western USA to 1.2 3.0, and 10 20 Mg/a, respectively. The emission estimate for areas of Hg mineralization in the western USA includes only identified Hg deposits and occurrences, and since other areas of geologic Hg enrichment such as Au and Ag deposits are not considered, the range in values is most likely an underestimate. Laboratory and field measurements have improved understanding of air surface Hg exchange associated with soils with low or natural background concentrations of Hg (<100 ppb), litter-covered forest floors, and foliar surfaces, all of which have large spatial coverage. Deposition of atmospheric Hg and re-emission are important processes occurring at these surfaces on diel and seasonal time scales. Foliage is a significant sink for atmospheric elemental Hg, however, the net flux associated with low Hg containing soils is uncertain. Mass balances developed for soil air exchange using measured fluxes and estimated deposition indicate that over a year background soils may exhibit no net flux. This suggests that the residence time for elemental Hg in the air is on the order of hours to weeks. Short term exchange would result in a homogenous air Hg concentration due to constant mixing and in an apparent calculated residence time that is most likely too long (one year). Recycling of atmospheric Hg between natural background soils and foliar surfaces also provides a mechanism for long-term atmospheric contamination and continued deposition in pristine ecosystems well after anthropogenic sources are controlled.

54 ENVIRONMENTAL SCIENCES↗

Characterization and modeling of the cemented sediment surrounding the Iulia Felix glass

About 1800 years ago a Roman Corbita sunk off the coast of Italy carrying a barrel of glass cullet to the floor of the Adriatic Sea. Samples of glass cullet and the cemented surrounding sediment have been characterized and the reaction between the glass and the sea water saturated with respect to calcite and dolomite has been modeled. Results from characterization and modeling show that the cement phase surrounding the sediment grains is a high-Mg calcite. The origin of the cement phase is likely the reaction between the glass and the sea water to from a Mg-silicate, here modeled as sepiolite.

archaeological glass↗

Impact of post-rainfall evaporation from porous roof tiles on building cooling load in subtropical China

Rainfall occurs frequently in subtropical regions of China, with the subsequent water evaporation from building roofs impacting the thermal performance and the energy consumption of buildings. In this paper, we proposed a novel simulation method using actual meteorological data to evaluate this impact. New features were developed in EnergyPlus to enable the simulation: (1) an evaporation latent heat flux source term was added to the heat balance equation of the external surface and (2) algorithms for the evaporative cooling module (ECM) were developed and implemented into EnergyPlus. The ECM experimental results showed good agreement with the simulated results. The ECM was used to assess the impact of evaporation from porous roof tiles on the cooling load of a one-floor building in subtropical China. The results show that the evaporation process decreased the maximal values of the external and internal roof surface temperatures by up to 6.4 °C and 3.2 °C, respectively, while the lower internal surface temperature decreased the room accumulated cooling load by up to 14.8% during the hot summer period. Lastly, the enhanced EnergyPlus capability can be used to evaluate the evaporative cooling performance of roofs with water-storage mediums, as well as to quantify their impact on building cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber

Finding unequivocal evidence of dark matter interactions in a particle detector is a major goal of research in physics. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nuclei down to the so-called neutrino floor, in a mass range from a few GeV to hundreds of TeV. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all types of events observed in the detector, is essential for the optimal design of the new experiment. In this article, we report on a specific set of events, namely, standard two-pulse scintillation–ionization signals with a third small amplitude pulse, occurring within the 440 μ s data acquisition window of standard events. Some of these events are due to the photoionization of the TPC cathode. We compare our results with those published by collaborations using liquid xenon time projection chambers, which observed a similar phenomenon, and, in particular, with a recent paper by the LUX Collaboration (D.S. Akerib et al. Phys.Rev.D 102, 092004 (2020)) From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths of around 128 nm, in liquid argon. Also, both experiments observe events likely related to the photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be an order of magnitude lower in DarkSide-50 than in LUX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracing the source of soil organic matter eroded from temperate forest catchments using carbon and nitrogen isotopes

Here, soil erosion continuously redistributes soil and associated soil organic matter (SOM) on the Earth's surface, with important implications for biogeochemical cycling of essential elements and terrestrial carbon sequestration. Despite the importance of soil erosion, surprisingly few studies have evaluated the sources of eroded carbon (C). We used natural abundance levels of the stable and radioactive isotopes of C ( 13 C and 14 C) and stable isotope of nitrogen ( 15 N) to elucidate the origins of SOM eroded from low-order catchments along the western slopes of the Sierra Nevada of California, USA. Our work was conducted in two relatively undisturbed catchments (low elevation = 1800 m, and high elevation = 2300 m) of the Kings River Experimental Watersheds (KREW) in the Sierra National Forest. Sediment captured in basins at the outlet of each gauged watershed were compared to possible source materials, which included: upland surficial organic horizons (i.e., forest floor) and mineral soils (0–0.6 m) from three landform positions (i.e., crest, backslope, and toeslope), stream bank soils (0–0.6 m), and stream-bed materials (0–0.05 m). We found that most of the organic matter (OM) in the captured sediments was composed of O-horizon material that had high C concentrations. Radiocarbon analyses also showed that the captured OM is composed of modern (post-1950) C, with fraction modern values at or above 1.0. Our results suggest that surface (sheet) erosion, as opposed to channeling through established streams and episodic mass wasting events, is likely the largest source of sediment exported out of these minimally disturbed, headwater catchments. The erosional export of sediment with a high concentration of C, especially in the form of relatively undecomposed litter from the O horizon, suggests that a large fraction of the exported C is likely to be decomposed during or after erosion; hence, it is unlikely that soil erosion acts as a significant net sink for atmospheric CO 2 in these low-order, temperate forest catchments.

54 ENVIRONMENTAL SCIENCES↗

A techno-economic survey of energy storage media for long-duration energy storage applications

Energy storage technologies that can economically store and provide electricity over multi-day and seasonal timescales are likely to be a critical component of a sustainable and resilient energy system. In this analysis, we perform a broad survey of energy storage technologies to find storage media (SM) that are promising for these long-duration energy storage (LDES) applications. The energy capital cost of the SM is identified as a key figure of merit for LDES. We develop a data collection framework to collect material price and physical property data, which are used to calculate the energy capital cost floor for 376 SM. These costs are then compared with cost targets for the LDES applications. The results show a multitude of thermal and chemical SM are economically promising, including some synthetic fuels, sensible thermal, latent thermal, thermochemical, and batteries based on low-cost materials. In contrast, currently deployed energy storage systems such as lithium-ion batteries and pumped hydro storage do not appear to be promising systems for LDES applications.

25 ENERGY STORAGE↗

Digitalization of an experimental electrochemical reactor via the smart manufacturing innovation platform

The exponential increase in data produced over the last two decades has revolutionized the way we collect, store, process, analyze, model, and interpret information to improve profitability. Manufacturing is no exception. How- ever, Smart Manufacturing, the digital practice, organization, workforce, and infrastructure transformation for collection and deployment of data and models at scale and at all levels of manufacturing, is a complex, costly, and labor-intensive journey that is still seeing slow adoption. The Clean Energy Smart Manufacturing Innovation Institute (CESMII), a national Manufacturing USA public-private partnership sponsored by the Department of Energy, is addressing this scaled use of data and modeling in manufacturing. CESMII has focused on how to col- lect and use operating data for numerous applications that improve productivity, precision, and performance of manufacturing operations from factory floor to supply chain using process simulation, predictive analytics, mon- itoring and control, and real-time optimization. Because contextualized data are key, CESMII has developed the Smart Manufacturing Innovation Platform (SMIP) to lower the barriers to the data that are needed to accelerate data-based model building, improve data visualization, and more quickly gain insights. Reusable, standards-based ways of doing data collection, ingestion, and contextualization are particularly important for scaling access and use of data. The SMIP uses a standards-based definition and construct for reusable information models called an SM Profile. When an SM Profile is used in conjunction with the SMIP, the SMIP ensures the availability of contextualized, operational data for model building. The present work demonstrates Smart Manufacturing and the application of the SMIP for building several data-centered models for the operation and control of an ex- perimental electrochemical reactor that reduces carbon dioxide (CO 2 ) gas to valuable liquid and gas chemicals, such as alcohols, olefins, and syngas. We describe how the SMIP plays a central role in more effective model building and we demonstrate how the electochemical reactor can be controlled and optimized for the desired products. Use of the SMIP involves the transmission of real-time sensor measurements to a cloud resource so that the operating data are available to all model building experts. The data collection and transmission process is fully automated to greatly reduce the need for manual manipulation of the data. Data-driven machine learning models are used for advanced real-time state estimation, real-time optimization, and model-based feedback control for the reactor. The application models are implemented as a system to monitor the data flow and control the electrochemical reactor with a single visualization interface. SM Profiles are used to demonstrate reusability of the information models for the reactor and the instrumentation. The application packages, algorithms, and user interfaces developed are cast as Docker images in a library to facilitate reusability of the application models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Building rehabilitation versus demolition and new construction: Economic and environmental assessment

Since the end of the twentieth century, discussion on dwelling rehabilitation versus its demolition and new construction has been steadily increasing in intensity, which is especially due to the necessity for the regeneration of urban centres. However, rehabilitation is not always considered the most economical solution, and demolition and new construction may constitute a better option. In the present work, a multi-family building in Seville, Spain, is used as a case study. After having suffered damage from a construction failure, it is assessed for its complete rehabilitation. Defective maintenance has worsened the bad condition of the building. A model is proposed, from the project budget perspective, that allows the environmental (Ecological Footprint indicator) and the economic (project's bill of quantities) assessment of the recovery of the dwelling. In the case study, the rehabilitation Ecological Footprint and the project cost are 0.06 gha/m{sup 2} of floor area (457.22 EUR/m{sup 2}) and 0.14 gha/m{sup 2} (576.33 EUR/m{sup 2}) for a new building on the same plot, respectively. It can be deduced that, even with a severely damaged building, the repair and retrofit work incurs a lower economic and environmental impact than that of the total replacement with a new construction.

54 ENVIRONMENTAL SCIENCES↗

Regional Analysis of Building Distributed Energy Costs and CO2 Abatement: A U.S. - China Comparison

The following paper conducts a regional analysis of the U.S. and Chinese buildings? potential for adopting Distributed Energy Resources (DER). The expected economics of DER in 2020-2025 is modeled for a commercial and a multi-family residential building in different climate zones. The optimal building energy economic performance is calculated using the Distributed Energy Resources Customer Adoption Model (DER CAM) which minimizes building energy costs for a typical reference year of operation. Several DER such as combined heat and power (CHP) units, photovoltaics, and battery storage are considered. The results indicate DER have economic and environmental competitiveness potential, especially for commercial buildings in hot and cold climates of both countries. In the U.S., the average expected energy cost savings in commercial buildings from DER CAM?s suggested investments is 17percent, while in Chinese buildings is 12percent. The electricity tariffs structure and prices along with the cost of natural gas, represent important factors in determining adoption of DER, more so than climate. High energy pricing spark spreads lead to increased economic attractiveness of DER. The average emissions reduction in commercial buildings is 19percent in the U.S. as a result of significant investments in PV, whereas in China, it is 20percent and driven by investments in CHP. Keywords: Building Modeling and Simulation, Distributed Energy Resources (DER), Energy Efficiency, Combined Heat and Power (CHP), CO2 emissions 1. Introduction The transition from a centralized and fossil-based energy paradigm towards the decentralization of energy supply and distribution has been a major subject of research over the past two decades. Various concerns have brought the traditional model into question; namely its environmental footprint, its structural inflexibility and inefficiency, and more recently, its inability to maintain acceptable reliability of supply. Under such a troubled setting, distributed energy resources (DER) comprising of small, modular, electrical renewable or fossil-based electricity generation units placed at or near the point of energy consumption, has gained much attention as a viable alternative or addition to the current energy system. In 2010, China consumed about 30percent of its primary energy in the buildings sector, leading the country to pay great attention to DER development and its applications in buildings. During the 11th Five Year Plan (FYP), China has implemented 371 renewable energy building demonstration projects, and 210 photovoltaics (PV) building integration projects. At the end of the 12th FYP, China is targeting renewable energy to provide 10percent of total building energy, and to save 30 metric tons of CO2 equivalents (mtce) of energy with building integrated renewables. China is also planning to implement one thousand natural gas-based distributed cogeneration demonstration projects with energy utilization rates over 70percent in the 12th FYP. All these policy targets require significant DER systems development for building applications. China?s fast urbanization makes building energy efficiency a crucial economic issue; however, only limited studies have been done that examine how to design and select suitable building energy technologies in its different regions. In the U.S., buildings consumed 40percent of the total primary energy in 2010 [1] and it is estimated that about 14 billion m2 of floor space of the existing building stock will be remodeled over the next 30 years. Most building?s renovation work has been on building envelope, lighting and HVAC systems. Although interest has emerged, less attention is being paid to DER for buildings. This context has created opportunities for research, development and progressive deployment of DER, due to its potential to combine the production of power and heat (CHP) near the point of consumption and delivering multiple benefits to customers, such as cost

25 ENERGY STORAGE↗