Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Lotic Water Hydrodynamic Model

Water-related natural disasters, for example, floods and droughts, are among the most frequent and costly natural hazards, both socially and economically. Many of these floods are a result of excess rainfall collecting in streams and rivers, and subsequently overtopping banks and flowing overland into urban environments. Floods can cause physical damage to critical infrastructure and present health risks through the spread of waterborne diseases. Los Alamos National Laboratory (LANL) has developed Lotic, a state-of-the-art surface water hydrodynamic model, to simulate propagation of flood waves originating from a variety of events. Lotic is a two-dimensional (2D) flood model that has been used primarily for simulations in which overland water flows are characterized by movement in two dimensions, such as flood waves expected from rainfall-runoff events, storm surge, and tsunamis. In 2013, LANL developers enhanced Lotic through several development efforts. These developments included enhancements to the 2D simulation engine, including numerical formulation, computational efficiency developments, and visualization. Stakeholders can use simulation results to estimate infrastructure damage and cascading consequences within other sets of infrastructure, as well as to inform the development of flood mitigation strategies.

16 TIDAL AND WAVE POWER↗

PH Sensitive Polymers for Improving Reservoir Sweep and Conformance Control in Chemical Flooring

There is an increasing opportunity to recover bypassed oil from depleted, mature oilfields in the US. The recovery factor in many reservoirs is low due to inefficient displacement of the oil by injected fluids (typically water). The use of chemical flooding methods to increase recovery efficiencies is severely constrained by the inability of the injected chemicals to contact the bypassed oil. Low sweep efficiencies are the primary cause of low oil recoveries observed in the field in chemical flooding operations even when lab studies indicate high oil recovery efficiency. Any technology that increases the ability of chemical flooding agents to better contact the remaining oil and reduce the amount of water produced in conjunction with the produced oil will have a significant impact on the cost of producing oil domestically in the US. This translates directly into additional economically recoverable reserves, which extends the economic lives of marginal and mature wells. The objective of this research project was to develop a low-cost, pH-triggered polymer for use in IOR processes to improve reservoir sweep efficiency and reservoir conformance in chemical flooding. Rheological measurements made on the polymer solution, clearly show that it has a low viscosity at low pH and exhibits a sudden increase in viscosity (by 2 orders of magnitude or more) at a pH of 3.5 to 4. This implies that the polymer would preferentially flow into zones containing water since the effective permeability to water is highest in these zones. As the pH of the zone increases due to the buffering capacity of the reservoir rock, the polymer solution undergoes a liquid to gel transition causing a sharp increase in the viscosity of the polymer solution in these zones. This allows operationally robust, in-depth conformance treatment of such water bearing zones and better mobility control. The rheological properties of HPAM solutions were measured. These include: steady-shear viscosity and viscoelastic behavior as functions of pH; shear rate; polymer concentration; salinity, including divalent ion effects; polymer molecular weight; and degree of hydrolysis. A comprehensive rheological model was developed for HPAM solution rheology in terms of: shear rate; pH; polymer concentration; and salinity, so that the spatial and temporal changes in viscosity during the polymer flow in the reservoir can be accurately modeled. A series of acid coreflood experiments were conducted to understand the geochemical reactions relevant for both the near-wellbore injection profile control and for conformance control applications. These experiments showed that the use hydrochloric acid as a pre-flush is not viable because of the high reaction rate with the rock. The use of citric acid as a pre-flush was found to be quite effective. This weak acid has a slow rate of reaction with the rock and can buffer the pH to below 3.5 for extended periods of time. With the citric acid pre-flush the polymer could be efficiently propagated through the core in a low pH environment i.e. at a low viscosity. The transport of various HPAM solutions was studied in sandstones, in terms of permeability reduction, mobility reduction, adsorption and inaccessible pore volume with different process variables: injection pH, polymer concentration, polymer molecular weight, salinity, degree of hydrolysis, and flow rate. Measurements of polymer effluent profiles and tracer tests show that the polymer retention increases at the lower pH. A new simulation capability to model the deep-penetrating mobility control or conformance control using pH-sensitive polymer was developed. The core flood acid injection experiments were history matched to estimate geochemical reaction rates. Preliminary scale-up simulations employing linear and radial geometry floods in 2-layer reservoir models were conducted. It is clearly shown that the injection rate of pH-sensitive polymer solutions can be significantly increased by injecting it at a pH below 3.5 (at a fixed bottom-hole pressure). This improvement in injectivity by a factor of 2 to 10 can have a significant impact on the economics of chemical flooding and conformance control applications. Simulation tools and experimental data presented in this report help to design and implement such polymer injection projects.

02 PETROLEUM↗

Hazard Assessment from Storm Tides and Rainfall on a Tidal River Estuary

Here, we report on methods and results for a model-based flood hazard assessment we have conducted for the Hudson River from New York City to Troy/Albany at the head of tide. Our recent work showed that neglecting freshwater flows leads to underestimation of peak water levels at up-river sites and neglecting stratification (typical with two-dimensional modeling) leads to underestimation all along the Hudson. As a result, we use a three-dimensional hydrodynamic model and merge streamflows and storm tides from tropical and extratropical cyclones (TCs, ETCs), as well as wet extratropical cyclone (WETC) floods (e.g. freshets, rain-on-snow events). We validate the modeled flood levels and quantify error with comparisons to 76 historical events. A Bayesian statistical method is developed for tropical cyclone streamflows using historical data and consisting in the evaluation of (1) the peak discharge and its pdf as a function of TC characteristics, and (2) the temporal trend of the hydrograph as a function of temporal evolution of the cyclone track, its intensity and the response characteristics of the specific basin. A k-nearest-neighbors method is employed to determine the hydrograph shape. Out of sample validation tests demonstrate the effectiveness of the method. Thus, the combined effects of storm surge and runoff produced by tropical cyclones hitting the New York area can be included in flood hazard assessment. Results for the upper Hudson (Albany) suggest a dominance of WETCs, for the lower Hudson (at New York Harbor) a case where ETCs are dominant for shorter return periods and TCs are more important for longer return periods (over 150 years), and for the middle-Hudson (Poughkeepsie) a mix of all three flood events types is important. However, a possible low-bias for TC flood levels is inferred from a lower importance in the assessment results, versus historical event top-20 lists, and this will be further evaluated as these preliminary methods and results are finalized. Future funded work will quantify the influences of sea level rise and flood adaptation plans (e.g. surge barriers). It would also be valuable to examine how streamflows from tropical cyclones and wet cool-season storms will change, as this factor will dominate at upriver locations.

Hazard assessment↗

Chapter 12: Sea Level Rise

Global mean sea level (GMSL) has risen by about 7-8 inches (about 16-21 cm) since 1900, with about 3 of those inches (about 7 cm) occurring since 1993. Human-caused climate change has made a substantial contribution to GMSL rise since 1900, contributing to a rate of rise that is greater than during any preceding century in at least 2,800 years. Relative to the year 2000, GMSL is very likely to rise by 0.3-0.6 feet (9-18 cm) by 2030, 0.5-1.2 feet (15-38 cm) by 2050, and 1.0-4.3 feet (30-130 cm) by 2100. Future pathways have little effect on projected GMSL rise in the first half of the century, but significantly affect projections for the second half of the century. Emerging science regarding Antarctic ice sheet stability suggests that, for high emission scenarios, a GMSL rise exceeding 8 feet (2.4 m) by 2100 is physically possible, although the probability of such an extreme outcome cannot currently be assessed. Regardless of pathway, it is extremely likely that GMSL rise will continue beyond 2100. Relative sea level (RSL) rise in this century will vary along U.S. coastlines due, in part, to changes in Earth's gravitational field and rotation from melting of land ice, changes in ocean circulation, and vertical land motion (very high confidence). For almost all future GMSL rise scenarios, RSL rise is likely to be greater than the global average in the U.S. Northeast and the western Gulf of Mexico. In intermediate and low GMSL rise scenarios, RSL rise is likely to be less than the global average in much of the Pacific Northwest and Alaska. For high GMSL rise scenarios, RSL rise is likely to be higher than the global average along all U.S. coastlines outside Alaska. Almost all U.S. coastlines experience more than global mean sea level rise in response to Antarctic ice loss, and thus would be particularly affected under extreme GMSL rise scenarios involving substantial Antarctic mass loss. As sea levels have risen, the number of tidal floods each year that cause minor impacts (also called "nuisance floods") have increased 5- to 10-fold since the 1960s in several U.S. coastal cities. Rates of increase are accelerating in over 25 Atlantic and Gulf Coast cities. Tidal flooding will continue increasing in depth, frequency, and extent this century. Assuming storm characteristics do not change, sea level rise will increase the frequency and extent of extreme flooding associated with coastal storms, such as hurricanes and nor'easters. A projected increase in the intensity of hurricanes in the North Atlantic could increase the probability of extreme flooding along most of the U.S. Atlantic and Gulf Coast states beyond what would be projected based solely on RSL rise. However, there is low confidence in the projected increase in frequency of intense Atlantic hurricanes, and the associated flood risk amplification and flood effects could be offset or amplified by such factors as changes in overall storm frequency or tracks.

Sweet, W. V.↗

FloodPlanet: High-Resolution Commercial Imagery for Training and Validation of Deep Learning-Based Models of Inundation Extent

Flooding events are becoming increasingly frequent worldwide and are known to cause extensive damage. Public optical and radar satellite imagery can be used to detect large areas of inundation in rural areas, however, long revisit times and coarse spatial resolution limit applications for short-lived events and urban areas. Commercial constellations such as those operated by Planet offer increased spatial and temporal resolution and can supplement mapping efforts to provide more information to disaster response, relief, and mitigation efforts. Deep learning requires high quality labeled data for training across coincident sensors. The FloodPlanet dataset presented here contains labeled surface water for 18 events across the world based on Planetscope imagery with coincident Harmonized Landsat Sentinel-2 ( HLS) or Sentinel-1 and builds upon the previously existing Sen1Floods11, xBD, and NASA Sentinel-1 datasets. Sen1Floods11 includes 4,831 512x512 pixel overlapping tiles of coincident Sentinel-1 and Sentinel-2 data observing 11 flood events across the world from 2017-2019. The dataset contains a combination of automated and hand-labeled surface water for use in training and validation of inundation modeling efforts. The xBD dataset identifies flood-damaged buildings and indicates the scale of damage to each (none, minor, moderate, and major) from four flood events which occurred in the United States, India, Nepal, and Bangladesh from the same time period. The NASA dataset contains hand-labeled water bodies observed in Sentinel-1 imagery during five flood events within the 2017-2019 period. The effort presented here utilizes observations from these previously investigated flood events to generate labels of surface water at the 3-5m spatial resolution provided by Planetscope and facilitate the comparison between public and commercial data. A data pipeline was built which uses clustering algorithms to pick the most suitable overlapping chips between the public data and PlanetScope data for manual labeling. Labels were created manually using NASA’s ImageLabeler tool and include areas of high- and low-confidence water. The high confidence designation is reserved for areas of open, unobstructed water while low confidence is used for areas of suspected water beneath vegetation, clouds, or cloud shadows. Expected to be released in late 2022, the FloodPlanet dataset will include tiled imagery with a unique ID for each 1024x1024 pixel tile, 7 bands of HLS data, and high- and low-confidence flood labels in both shapefile and tiff formats. The authors will follow Spatial Temporal Access Catalog (STAC) guidelines to release FloodPlanet on the Radiant Earth ML hub, which hosts public datasets for machine learning.

Alexander Melancon↗

Columbia River Treaty 2014/2024 Review: Phase 1 Technical Studies

Since 1964, the Columbia River Treaty has provided significant benefits to the United States and Canada through coordinated river management by the two countries. It remains the standard against which other international water coordination agreements around the world are compared. When the Treaty was negotiated, its goals were to provide significant flood control and power generation benefits to both countries. However, the Treaty contains two provisions that may significantly change these benefits as early as the year 2024. First, in 2024 the 60 years of purchased flood control space in Canadian Treaty projects expires. Instead of a coordinated and managed plan to regulate both Canadian and U.S. projects for flood control, the Treaty calls for a shift to a Canadian operation under which the United States can call upon Canada for flood control assistance. The United States can request this “called upon” assistance as needed but only to the extent necessary to meet forecast flood control needs in the United States that cannot adequately be met by U.S. projects. When called upon is requested, the United States will then have to pay Canada for its operational costs and any economic losses resulting from the called upon flood control operation. Second, while the Treaty has no specified end date, it does allow either Canada or the United States the option to terminate most of the provisions of the Treaty on or after Sept. 16, 2024, with a minimum of 10 years advance written notice. Thus, the year 2024 is the first year a notice of termination would take effect assuming written notice of termination is given by the Canadian or U.S. governments by 2014. Unless the Treaty is terminated or the federal governments elect to modify the Treaty, its provisions continue indefinitely, except for the changes in flood control discussed above. Given the significance of both of these provisions, it is important that the parties to the Treaty understand the implications for post-2024 Treaty planning and Columbia River operations. The U.S. Army Corps of Engineers and the Bonneville Power Administration, the agencies that implement the Treaty in the United States on behalf of the U.S. Entity (see Treaty Governance sidebar), are conducting a multi-year effort to understand these implications. This effort is called the 2014/2024 Columbia River Treaty Review.

Columbia River Treaty, United States, Canada, tech↗

Characterizing the Non-linear Interactions Between Tide, Storm Surge, and River Flow in the Delaware Bay Estuary, United States

Low-lying coastal areas in the mid-Atlantic region are prone to compound flooding resulting from the co-occurrence of river floods and coastal storm surges. To better understand the contribution of non-linear tide-surge-river interactions to compound flooding, the unstructured-grid Finite Volume Community Ocean Model was applied to simulate coastal storm surge and flooding in the Delaware Bay Estuary in the United States. The model was validated with tide gauge data in the estuary for selected hurricane events. Non-linear interactions between tide-surge-river were investigated using a non-stationary tidal analysis method, which decomposes the interactions’ components at the frequency domain. Model results indicated that tide-river interactions damped semidiurnal tides, while the tide-surge interactions mainly influenced diurnal tides. Tide-river interactions suppressed the water level upstream while tide-surge interaction increased the water level downstream, which resulted in a transition zone of damping and enhancing effects where the tide-surge-river interaction was prominent. Evident compound flooding was observed as a result of non-linear tide-surge-river interactions. Furthermore, sensitivity analysis was carried out to evaluate the effect of river flooding on the non-linear interactions. The transition zone of damping and enhancing effects shifted downstream as the river flow rate increased.

54 ENVIRONMENTAL SCIENCES↗

Planning green infrastructure placement based on projected precipitation data

Continued urbanization has led to tremendous changes on the landscape. These changes have exacerbated the effects of extreme climatic events such as flooding because of constrained water infiltration and increased surface flow. Typical runoff control measures involve sophisticated gray infrastructure that guide excess surface flow into storage and disposal sites. In a dynamic climate system, these measures are not sustainable since they cannot be easily modified to accommodate large volumes of runoff. Green Infrastructure (GI) is an adaptable technique that can be used to minimize runoff, in addition to offering an array of additional benefits (urban heat regulation, aesthetics, improved air quality etc.). Strategic placement of GI is key to achieving maximum utility. While physical site characteristics play a major role in determining suitable GI placement sites, knowledge of future precipitation patterns is crucial to ensure successful flood mitigation. Here, suitable GI sites within the city of Knoxville, Tennessee, were determined based on potential impact of an extreme flood event as indicated by site characteristics. Then, the relative potential likelihood of a flood event was determined based on projected precipitation data and knowledge of existing flood zones. By combining potential impact with likelihood information, low, medium, and high priority GI implementation sites were established. Results indicate that high priority sites are in the central parts of the city with priority decreasing outward. The GI prioritization scheme presented here, offers valuable guidance to city planners and policy makers who wish to exploit the GI approach for flood mitigation.

54 ENVIRONMENTAL SCIENCES↗

Development of A High Performance Cold Climate Heat Pump

The primary goals of the proposed project were to develop, test, and evaluate a high performance and cost-effective vapor compression air-source heat pump for use in cold climate regions. Vapor compression heat pumps are a proven technology, and have been used for many years to meet heating requirements for buildings in residential, commercial, and industrial applications. However, in climate regions that experience very low outdoor ambient temperatures both the heating capacity and coefficient of performance (COP) of traditional air-source vapor compression heat pumps drops dramatically with a decrease in the outdoor air temperature. The efficiency of heat pumping equipment has improved substantially over the past 20 years; however, the efficiencies of the highest rated equipment on the market are approaching practical limits that cannot be surpassed without modifications to the basic cycle and possibly the use of additional hardware. In this report, three technologies to improve the efficiency of vapor compression systems are described. These are a) vapor injected compression, b) oil flooded compression and c) hybrid flow control of the evaporator. Compressor prototypes for both, oil flooded and vapor injected compression were developed by Emerson Climate Technologies. For the oil flooded compressor, the oil injection port location was optimized and an internal oil separator was added using several design iterations. After initial testing at Emerson Climate Technologies, further testing was done at Purdue University, and compressor models were developed. These models were then integrated into a system model to determine the achievable improvement of seasonal energy efficiency (SEER) for Minneapolis (Minnesota) climate. For the oil flooded compression, a 34% improvement in seasonal energy efficiency was found while a 21% improvement in seasonal energy efficiency ratio was found for the vapor injected compression. It was found that one benefit of both tested compression technologies is a lower discharge temperature, which allows for continued operation at lower ambient temperatures. A bin analysis of the vapor injected prototype cold climate heat pump predicts a 6% improvement in HSPF for Minneapolis. This improvement is mainly a result of the increased capacity of the system for active vapor injection. For the oil flooded system, a slightly larger performance improvement is predicted, in this case mostly caused by an increase in heating COP. Based on an economic analysis of these results, the maximum additional cost of the system changes, for the Minneapolis location, are $\$430$ for the vapor injected system and $\$391$ for the oil flooded system. These estimates assume that a 3-year simple payback period is accepted by the customer. For the hybrid flow control of evaporators, a new type of balancing valve was developed together with Emerson Climate technologies to reduce the cost of the control scheme. In contrast to conventional stepper motor valves, this valve requires less cables and can be driven by a cheaper output circuit on the control board. The correct valve size was determined in a dedicated test stand in several design iterations. The performance benefits of the hybrid control of the evaporator coil were determined for clean coil conditions as well as with partial blockage of the air inlet grille and under frosting conditions. For clean coil conditions, the benefits in terms of COP and capacity are negligible. However, significant benefits were noted for severely air-maldistributed operating conditions. For the H2-test, the maximum COP improvement of 17% along with a capacity improvement of nearly 40% was observed. Overall, the hybrid control scheme leads to a significant amount of performance improvement, if the air inlet conditions to the evaporator are maldistributed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Critical Role of the Routing Scheme in Simulating Peak River Discharge in Global Hydrological Models

Global hydrological models (GHMs) have been applied to assess global flood hazards, but their capacity to capture the timing and amplitude of peak river discharge which is crucial in flood simulations has traditionally not been the focus of examination. Here we evaluate to what degree the choice of river routing scheme affects simulations of peak discharge and may help to provide better agreement with observations. To this end we use runoff and discharge simulations of nine GHMs forced by observational climate data (1971-2010) within the ISIMIP2a (Inter-Sectoral Impact Model Intercomparison Project phase 2a) project. The runoff simulations were used as input for the global river routing model CaMa-Flood (Catchment-based Macro-scale Floodplain). The simulated daily discharge was compared to the discharge generated by each GHM using its native river routing scheme. For each GHM both versions of simulated discharge were compared to monthly and daily discharge observations from 1701 GRDC (Global Runoff Data Centre) stations as a benchmark. CaMa-Flood routing shows a general reduction of peak river discharge and a delay of about two to three weeks in its occurrence, likely induced by the buffering capacity of floodplain reservoirs. For a majority of river basins, discharge produced by CaMa-Flood resulted in a better agreement with observations. In particular, maximum daily discharge was adjusted, with a multi-model averaged reduction in bias over about two-thirds of the analysed basin area. The increase in agreement was obtained in both managed and near-natural basins. Overall, this study demonstrates the importance of routing scheme choice in peak discharge simulation, where CaMa-Flood routing accounts for floodplain storage and backwater effects that are not represented in most GHMs. Our study provides important hints that an explicit parameterisation of these processes may be essential in future impact studies.

peak river discharge↗

Empirical correlations for prediction of minimum miscible pressure and near-miscible pressure interval for oil and CO 2 systems

Although near-miscible CO 2 flooding has recently received considerable attention, no criteria are available to predict its applicability to a specific reservoir. Evaluating the viability of near-miscible flooding requires experimental exploration of a specific region in pressure–temperature space. The near-miscible pressure field is bounded on one side in P, T space by the MMP (minimum miscible pressure). This paper provides robust empirical correlations to estimate the MMP for both pure and impure CO 2 and for prediction of the near-miscible pressure region for CO 2 -oil. Many slim tube analyses, lacking high density data points, systematically underestimate the MMP, when the near miscible region is not accounted for. They are based on 147 published data sets that include: slim tube experimental determination of MMP; interfacial tension (IFT) between oil and CO 2 ; concentration of solution gas; and purity of the CO 2 . This paper is the first to begin a systematic exploration of the pressure-temperature space within which near-miscible effects characterize CO 2 floods. Our new correlations provide a basis for identifying and investigating the nature of near miscible effects associated with existing CO 2 floods. For a case study of an offshore field we determined that lower and upper pressure boundaries for effective near-miscible flooding, are 0.87 MMP and 1.07 MMP at reservoir temperatures. The proposed model is the first empirical correlation for the prediction of near-miscible pressure region, it will provide the basis for both screening the relative potential of oil reservoirs for economically viable miscible or near-miscible CO 2 -flooding.

42 ENGINEERING↗

Changes in inundation drive carbon dioxide and methane fluxes in a temperate wetland

Wetlands cycle carbon by being net sinks for carbon dioxide (CO 2 ) and net sources of methane (CH 4 ). Daily and seasonal temporal patterns, dissolved oxygen (DO) availability, inundation status (flooded or dry/partially flooded), water depth, and vegetation can affect the magnitude of carbon uptake or emissions, but the extent and interactive effects of these variables on carbon gas fluxes are poorly understood. We characterized the linkages between carbon fluxes and these environmental and temporal drivers at the Old Woman Creek National Estuarine Research Reserve (OWC), OH. We measured diurnal gas flux patterns in an upstream side channel (called the cove) using chamber measurements at six sites (three vegetated and three non-vegetated). We sampled hourly from 7 AM to 7 PM and monthly from July to October 2022. DO concentrations and water levels were measured monthly. Water inundation status had the most influential effect on carbon fluxes with flooded conditions supporting higher CH 4 fluxes (0.39 μmol CH 4 m –2 s –1 ; –1.23 μmol CO 2 m –2 s –1 ) and drier conditions supporting higher CO 2 fluxes (0.03 μmol CH 4 m –2 s –1 ; 0.86 μmol CO 2 m –2 s –1 ). When flooded, the wetland was a net CO 2 sink; however, it became a source for both CH 4 and CO 2 when water levels were low. We compared chamber-based gas fluxes from the cove in flooded (July) and dry (August) months to fluxes measured with an eddy covariance tower whose footprint covers flooded portions of the wetland. The diurnal pattern of carbon fluxes at the tower did not vary with changing water levels but remained a CO 2 sink and a CH 4 source even when the cove where we performed the chamber measurements dried out. Furthermore, these results emphasize the role of inundation status on wetland carbon cycling and highlight the importance of fluctuating hydrologic patterns, especially hydrologic drawdowns, under changing climatic conditions.

54 ENVIRONMENTAL SCIENCES↗

Climate change and federal aid disbursements after Hurricane Harvey: an extreme event attribution analysis

The role climate change plays in increasing the burden placed on governments and insurers to pay for recovery has not been extensively explored and is the focus of this study. This study examines the impacts of climate change attributed flooding on federal disaster aid disbursement in Harris County, Texas following Hurricane Harvey in 2017. Our approach uses flood models to estimate the amount of flood damages attributable and not attributable to climate change under two climate change attribution scenarios from peer reviewed studies: 20% and 38% increases in rainfall associated with the hurricane due to climate change. These estimates are combined with census tract-level disbursement data for FEMA’s National Flood Insurance Program (NFIP) and the Individual Assistance (IA) part of the Individuals and Households Program. We employ spatial lag regression models with direct and spatial spillover effects to analyze the relationship between a tract’s flood damages—both attributed and not attributed to climate change—and federal disaster aid. We find that both types of flood damage shape federal aid disbursements, but that climate change attributed damages tend to have larger effect sizes (elasticities) especially for IA. Specifically, for a 1% increase in additional climate change attributed damages per household in a census tract (under the 20% scenario), expected NFIP levels in that census tract are 0.26% higher and IA levels are 0.3% higher. Implications center on federal funding in an era of climate change.

FEMA↗

Methane-cycling microbial communities from Amazon floodplains and upland forests respond differently to simulated climate change scenarios

Seasonal floodplains in the Amazon basin are important sources of methane (CH 4 ), while upland forests are known for their sink capacity. Climate change effects, including shifts in rainfall patterns and rising temperatures, may alter the functionality of soil microbial communities, leading to uncertain changes in CH 4 cycling dynamics. To investigate the microbial feedback under climate change scenarios, we performed a microcosm experiment using soils from two floodplains (i.e., Amazonas and Tapajós rivers) and one upland forest. We employed a two-factorial experimental design comprising flooding (with non-flooded control) and temperature (at 27 °C and 30 °C, representing a 3 °C increase) as variables. We assessed prokaryotic community dynamics over 30 days using 16S rRNA gene sequencing and qPCR. These data were integrated with chemical properties, CH 4 fluxes, and isotopic values and signatures. In the floodplains, temperature changes did not significantly affect the overall microbial composition and CH 4 fluxes. CH 4 emissions and uptake in response to flooding and non-flooding conditions, respectively, were observed in the floodplain soils. By contrast, in the upland forest, the higher temperature caused a sink-to-source shift under flooding conditions and reduced CH 4 sink capability under dry conditions. The upland soil microbial communities also changed in response to increased temperature, with a higher percentage of specialist microbes observed. Floodplains showed higher total and relative abundances of methanogenic and methanotrophic microbes compared to forest soils. Isotopic data from some flooded samples from the Amazonas river floodplain indicated CH 4 oxidation metabolism. This floodplain also showed a high relative abundance of aerobic and anaerobic CH 4 oxidizing Bacteria and Archaea. Taken together, our data indicate that CH 4 cycle dynamics and microbial communities in Amazonian floodplain and upland forest soils may respond differently to climate change effects. We also highlight the potential role of CH 4 oxidation pathways in mitigating CH 4 emissions in Amazonian floodplains.

16S rRNA sequencing↗

Heavy Oil Polymer EOR in the Challenging Alaskan Arctic - It Works!

Under co-sponsorship of the US Department of Energy and Hilcorp Alaska LLC the first ever polymer field pilot commenced on 8/28/2018 in the Schrader Bluff heavy oil reservoir at the Milne Point Field on Alaska North Slope (ANS). The primary objective of the pilot is to prove the efficacy of polymer Enhanced Oil Recovery (EOR) to unlock the vast heavy oil resources on ANS. More than two and half years after startup, the polymer injection, supporting laboratory experiments and simulation studies steadily continue. The pilot started injecting hydrolyzed polyacrylamide (HPAM), at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP, into the two horizontal injectors in the flood pattern. Production is monitored in the two horizontal producers. Based on laboratory measurements of polymer viscosity at reservoir conditions, the team decided to reduce polymer concentration to 1,200 ppm since July 2020 in an effort to control injection pressure and optimize polymer utilization. Quality control (QC) on the field ensures uniform polymer solution properties. Representative rock and fluid systems and test conditions are utilized in the corefloods on polymer retention, effect of injection water salinity, polymer loading, and their combinations on oil recovery. A history matched reservoir simulation model for forecasting oil recovery was developed on the basis of all the available field data. Field concerns related to the post-polymer breakthrough impact on flow assurance is addressed via specialized laboratory tests. Notwithstanding early operational disruptions and hydration issues, continuous polymer injection in both injectors has been achieved. To date, 950,000 lbs of polymer or 2 million barrels of polymer solution, equating to 13% of total pore volume (PV), has been placed in the flood pattern, serving as an effective indicator of adequate polymer injectivity. So far, the success of polymer EOR is evident from drastically reduced water cut in the producers, an estimated incremental 1,000 bopd over waterflood, and a favorable polymer utilization of 1.7 lbs/barrel of incremental oil. Polymer breakthrough was observed 26 months after the start of polymer injection. Main observations from corefloods are unusually high polymer retention values in some cases and a positive response to low salinity water. Although the heterogeneity in the flood pattern and exceptionally low water cut pose some challenges, persistent novel and justifiable simulation approaches have resulted in a robust history matched model. Experimental results on produced fluids treatment provide operational guidance for improved oil-water separation and mitigation of heater tube fouling. The ongoing success of the pilot is a key indicator of bringing the team ever closer to meeting the project’s primary objective. The encouraging results of the pilot is one of the drivers that has provided the impetus to apply polymer EOR throughout the Milne Point Field, which would increase oil recovery and extend the economic life of the Trans Alaska Pipeline System. The scientific knowledge, including the many lessons learned from this pilot also has referential value for other potential heavy oil EOR projects throughout the world. The collected data, operational lessons learned, and the overall success of the pilot are summarized in the paper.

None, None↗

The SURE House (Solar Decathlon 2015)

Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable architecture for New Jersey and beyond. This is what informed the architectural design of the house. Configured about a compact form, thickly insulated and air-sealed walls eliminate thermal bridging and minimize energy losses while advanced glazing brings in free solar heat during the winter months. As a result of these passive design strategies, the SURE HOUSE has a greatly reduced carbon footprint requiring 91% less energy than a typical New Jersey home. Photovoltaic (PV) arrays on both the rooftop and operable shutters easily provide energy in excess of the home’s modest demands. The Stevens team considers a truly sustainable home in the era of climate change, one that prioritizes low energy use, and integrates right-sized renewable generation to supply the home’s needs. Low consumption, low production. RESILIENT In October of 2012, Hurricane Sandy wreaked havoc along the east coast of the US. In New Jersey alone there was an estimated 29.4 billion dollars in damages, 346,000 homes affected, and almost two and a half million people left without power, in some cases for over 10 days. Recovery from this storm and associated flooding is ongoing to this day, as many New Jersey homeowners grapple with the large costs of rebuilding and struggle to adapt to complicated new home building regulations. Damage from this storm to Hoboken, the home of the Stevens Institute of Technology’s campus, and to the New Jersey shore was extensive and many students on the SURE HOUSE team were directly affected by this historic event. The Stevens design team recognizes that in a world of more frequent and stronger storms, the ability to absorb and adapt to change is more important than ever. Successfully weathering the next storm and its aftermath is one of the primary goals in the design of the SURE HOUSE prototype. The SURE HOUSE introduces unique ‘dry flood-proofing’ methods to residential construction. Innovative wall and floor flood-proofing, utilizing durable composite sheathing materials adapted from the boating industry, were developed by the student team to render the SURE House’s building envelope flood proof up to the FEMA AE 6/7 Zone (+ 6/7 feet of water above sea-level). Designed and fabricated utilizing glass-fiber composite materials, the custom storm shutter system serves to protect the large glazed openings of the home from both air-borne debris impact and water infiltration during a storm event while also providing deterrence from the vandalism that often occurs in the aftermath of a calamitous event. During extended power outages, a ‘resilient’ solar array is capable of supplying critical amounts of energy and hot water to the home, without the use of battery storage or grid infrastructure. PV Description AC GRID-TIED PV SYSTEM The SURE HOUSE solar system consists of two distinct arrays, the grid-tied rooftop array which produces AC Powerand the shutter-mounted array which converts DC power generated by the modules directly into usable heat for the domestic hot water (DHW). The roof-mounted AC grid-tied array is comprised of three strings, two 11 module strings connected to an SMA SB 5000TL-US-223 inverter and a single 10 module string equipped and an SMA SB 3000TL-US-22 central inverter. All modules for the rooftop AC array are LG MonoX 2804 watt solar panels, chosen for their durability and efficiency. Inverter sizing and string size are optimized to the electrical characteristics of the chosen PV modules and the desired energy production, see Appendix 5B. The SURE HOUSE is projected to produce 12,353 kWh per year to meet 6,157 kWh per year of estimated consumption. Solar modules for the two AC grid-tied sub arrays are mounted on the main roof surface of the SURE HOUSE with a 10 degree tilt angle using a partially-ballasted polyethylene roof mounting system made by Renusol, which is particularly suited to the corrosive salt air of a coastal environment. This method was chosen for its installation simplicity and to limit detrimental roof penetrations. The 10 degree tilt optimizes the energy generated per roof area at a lower price, see Appendix 5A, and ensures that there is minimal wind uplift. DC SOLAR ELECTRIC DOMESTIC HOT WATER The SURE HOUSE’s approach to sustainable and resilient domestic hot water (DHW) consists of a unique, custom engineered DC solar electric hot water system. Employing the use of Advanced Energy’s DC electric PV heater (DCPVH)5 to heat domestic water well beyond the draw temperature, the SURE HOUSE is able to obtain a remarkably high solar fraction of 75% or more. The custom modified 80 gallon Vaughn DHW tank acts as a large solar ‘battery’ that stores heat energy in the form of hot water at almost 150 degrees, harvesting energy when the sun is out for use later in the day or overnight. The system, which uses electricity rather than heated fluid, is distinct from traditional ‘solar thermal’ systems by eliminating the dangers and associated maintenance issues of fluid based systems. By forgoing the use of external fluid loops, overheated solar collectors and pipes are not an issue for the SURE HOUSE system which never needs any yearly or seasonal flushing. In weather conditions where the integrated DCPVH unit cannot produce enough hot water via solar energy alone, the Vaughn hot water tank comes factory made with an AC powered 2.6 COP heat pump and a AC heating coil that serve as back-up heating elements. The DCPVH is powered by a DC array consisting of 10 custom-made Solbian by PVilion 180 watt, monocrystalline, flexible solar modules6. The Solbian modules are directly mounted to the top half of the operable storm shutters on the south façade of the SURE HOUSE. The SURE HOUSE team worked closely with PVillion, a PV system designer specializing in flexible architectural photovoltaics, to design an adhesive system that works with the glass-fiber storm shutter surface in a reliable manner over an extended period. Because this system operates in DC-only mode and never connects to the municipal power grid, the system can continue to create hot water safely and effectively even during grid disruption events. This hot water, and the energy stored within it, could be used for a range of activities including washing and cooking to more elaborate hydronic heating systems as desired. See Appendix 6 for system engineering, sizing and modeling.

14 SOLAR ENERGY↗

Examples of Mission-driven Data Science from Jefferson Lab and ACES

This presentation details mission-driven data science initiatives at Jefferson Lab and the Joint Institute for Advanced Computing on Environmental Studies (ACES). JLab, a U.S. Department of Energy Office of Science national laboratory, operates the Continuous Electron Beam Accelerator Facility (CEBAF), and is the lead institute for the new High Performance Data Facility (HPDF) Hub. The Joint Institute for ACES brings together interdisciplinary teams in health informatics, climate modeling, computer science, and physics to address environmental challenges, including flood modeling. The Hampton Roads region, particularly Norfolk and Virginia Beach, faces increasing flood risks, motivating the need for rapid, reliable, and risk-aware decision support. ACES’s flooding work has a focus on uncertainty quantification (UQ) and machine learning (ML) for coastal flood management. The work is motivated by the increasing vulnerability of communities such as Norfolk and Virginia Beach, Virginia, to frequent coastal flooding events, and the need for rapid, reliable decision support. The research develops computationally efficient ML surrogate models to forecast water levels and flooding risk. A central theme is the quantification and calibration of predictive uncertainty, especially for out-of-distribution (OOD) scenarios, using techniques such as Monte Carlo Dropout, Deep Ensembles, Gaussian Processes, and Deep Quantile Regression (DQR). The study demonstrates that distance-aware UQ is critical for reliable scientific AI, particularly in high-dimensional, safety-critical, and real-time applications.

McSpadden, Diana [Thomas Jefferson National Accele↗

Channeling episodes of Kasei Valles, Mars, and the nature of ridged plains material

The geologic mapping compiled at 1:500,000 scale of the northern Kasei Valles area of Mars (MTMs 25062 and 25067) indicates (1) at least three periods of Kasei Valles channeling, (2) the development of Sacra Fossae (linear depressions on Tempe Terra and Lunae Planum) in relation to Kasei channeling episodes, and (3) the nature of ridged plains material dissected by Kasei Valles on northern Lunae Planum. (The three channeling periods consists of two flood events and a later, sapping related event). These findings suggest hydrologic conditions and processes that formed Kasei Valles and associated features and terrains. It is concluded that an early period of flooding, whose source is perhaps buried beneath lava flows of Tharsis Montes, may have eroded streamlined features in northern Lunae Planum. Also, later floods originating from Echus Chasma formed after the initial flooding and the mesas adjacent to the plateau. The Sacra Fossae formed after the initial flooding and during the second flooding by sapping, outbreak, scarp retreat, and collapse along joints and fractures in ridged plains materials.

Chapman, Mary G.↗