Online Monitoring of Medium Voltage Cable Systems with Spread Spectrum Time Domain and Frequency Domain Reflectometry

In-service failures of wave energy convertor (WEC) cable systems can have a significant cost and power availability impact. Close parallel research 2019 data showed > 1B£ and 9 Terra-Watt-Hours associated with global off-shore wind (OSW) cable failures (Strang-Moran 2020). OSW is a closely related technology but currently is significantly cheaper than WEC technology. For wave energy to compete, the problem of reliable cable transmission must be mitigated. This project develops isolation technology to allow online high frequency reflectometry testing of medium voltage cables (1 to 10 kV and higher) without arcing or damage to the test instrument. Online spread spectrum time domain reflectometry (SSTDR) testing has been established for low voltage cable systems in the aircraft and rail industry and the ability to detect and locate cable flaws of interest is well understood. Extending reflectometry testing to medium voltage systems could enable detection of cable damage before failures occur thereby allowing repair and replacement of damaged cable segments to be scheduled and managed. The seedling project succeeded to pass and receive high frequency SSTDR signals onto a cable up to 1 kV using a parallel trace isolation circuit board that can be connected onto the test cable. The approach used a novel circuit design for which an invention disclosure has been filed. A proposed sapling project would extend the technology toward the higher operating voltages used by WEC systems, thereby enabling online SSTDR cable monitoring. The goal of the seedling project was to extend the capability of the ARENA cable/motor test bed to address medium voltages and to develop a high pass filter isolation architecture to protect the reflectometry instrument from the low frequency (DC – 60 Hz) line voltage while allowing the high frequency diagnostic signal to pass to and from the test instrument to the live line. Initial efforts focused on passive LCR filter circuits to reduce 60 Hz levels below 10 volts from a 10 kV line while allowing the MHz high frequency chirps to pass onto the cables and for mV signals to be detected. We discovered that the parasitic loss behavior of real high voltage components precluded this approach from working. An alternate approach was adapted for the electric field to couple between two parallel traces on a printed circuit board much like a radio-frequency coupler. The challenge here was and is to have the parallel traces close enough to each other to effectively pass the high frequency chirp onto the live line and receive any reflected signal from any encountered impedance change along the cable. This reflected signal will be in the mV range. The traces however must be far enough apart to not allow arcing on the board. A design with 3 mm spacing was determined to allow the high frequency signal to pass onto the live line and receive the mV signal back into the instrument while reducing the 60 Hz voltage amplitude by >80 dB (more than a factor of 10,000) without allowing arcing from across the parallel traces. This was confirmed by simulation and test.

16 TIDAL AND WAVE POWER↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

advanced gas reactors↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine learning for single-ended event reconstruction in PROSPECT experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and particle classification. This work highlights the effectiveness of convolutional neural networks and graph convolutional networks in enhancing data analysis. By leveraging these techniques, a 3.3% increase in effective statistics was achieved compared to traditional methods, showcasing their potential to improve analysis performance. Furthermore, these machine learning methodologies offer promising applications for other segmented particle detectors, underscoring their versatility and impact.

47 OTHER INSTRUMENTATION↗

Review of Wave Energy Converter Power Take-Off Systems, Testing Practices, and Evaluation Metrics: Preprint

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. One of the difficulties that wave energy systems have been struggling to overcome is the design of highly efficient energy conversion systems that can convert the mechanical power, derived from the oscillation of wave activated bodies, into another useful product. Often the power take-off (PTO) is defined as the single unit responsible for converting mechanical power into another usable form such as electricity, pressurized fluid, compressed air, and others. The PTO, and the entire power conversion chain (PCC), is of great importance as it affects not only how efficient wave power is converted into electricity, but also contributes to the mass, size, structural dynamics, and levelized cost of energy (LCOE) of the wave energy converter (WEC). Unlike wind and solar, there is no industrial standard device, or devices, for wave energy conversion and this diversity is transferred to the PTO system. The majority of current WEC PTO systems incorporate a mechanical or hydraulic drive train, power generator, and an electrical control system. The challenge of WEC PTO designs is designing a mechanical-to-electrical component that can efficiently convert irregular, bi-directional, low frequency and low alternating velocity wave motions. While gross average power levels can be predicted in advance, the variable wave elevation input has to be converted into smooth electrical output and hence usually necessitates some type of energy storage system, such as battery storage, accumulator super capacitors, etc., or other means of compensation such as an array of devices. One of the primary challenges for wave energy converter systems is the fluctuating nature of wave resources, which require WEC components to be designed to handle loads (i.e. torques, forces, and powers) that are many times greater than the average load. This approach requires a much greater PTO capacity than the average power output and indicates a higher cost. In addition, supporting mechanical coupling and or gearing can be added to the PCC to help alleviate the difficulties with transmission and control of fluctuating large loads with low frequencies (indicative of wave forcing) into smaller loads at higher frequencies (optimum for conventional electrical machine design) can quickly increase the complexity of the PCC which could result in a greater number of failure modes and increased maintenance costs. All of the previous points demonstrate how the PTO influences WEC dynamics, reliability, performance and cost which are critical design factors. This paper further explores these topics by providing a review of the state-of-the-art PTO systems currently under development, how these novel PTO systems are tested and derisked prior to precommercial deployment, and the evaluation metrics historically used to differentiate between PTO designs and how they can be improved to support control co-design focused development of wave energy systems.

laboratory testing↗

Leveraging 3D CAD and Virtual Reality in Design of the Calcine Disposition Project - 20512

Fluor Idaho's Calcine Disposition Project (CDP) is leveraging the power of three-dimensional (3D) visualization, light detection and ranging (Lidar), and virtual reality to improve designs and worker safety. With the use of computer-aided design (CAD) modeling software, the CDP has created 3D models of the facility and systems to aid in the design, development, and operation of its retrieval and transfer system. This by itself is nothing new and has been done in industry for years. The CDP project however is taking this a few steps farther with the use of Lidar and virtual reality software. The CRP is tasked with removing a radioactive granular material from stainless steel bins located in concrete vaults that were constructed in the late 1950's and early 1960's. While construction drawings are available, it is not certain that the drawings are as-built or how accurate they truly are. Part of the project requires precise placement of equipment on to bins around multiple pipe, electrical lines, and bin stiffeners. Relying solely on the existing drawings and models created from these drawings is highly risky and prone to failure. The first step to determine the precise location and orientation of all obstructions in the vault the project will use a Lidar system to scan the vault structure and precisely locate all vault and bin components. Once this information is obtained, the data will be integrated into the CAD model. The model will then be verified, and a true as-built model developed. Precise component location, size, and orientation will be used for final design and placement of retrieval components. The second step will be to take the verified 3D model and scan data and import it into virtual reality software creating a virtual world. While some work on the project requires all work to be completed remotely due to high radiation fields, some areas have low enough radiation levels that personnel can enter and perform work. With the use of a virtual reality headset, operators and technicians will be able to enter our virtual world and become familiar with the surroundings and perform work prior to ever entering the radiation environment. This training is expected to pay dividends by improving worker efficiency, reducing errors, and improving confidence that the work can be performed as expected. It will play a key aspect in as low as reasonably achievable (ALARA) principles. An additional aspect in using the Lidar scans and virtual environment, is that it will give engineers and managers an opportunity to revisit the facility, especially radiation areas, at any time to obtain design information and measurements that may be costly or impossible to obtain once the facility transitions into radiation operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A regional nuclear conflict would compromise global food security

A limited nuclear war between India and Pakistan could ignite fires large enough to emit more than 5 Tg of soot into the stratosphere. Climate model simulations have shown severe resulting climate perturbations with declines in global mean temperature by 1.8 °C and precipitation by 8%, for at least 5 y. Here we evaluate impacts for the global food system. Six harmonized state-of-the-art crop models show that global caloric production from maize, wheat, rice, and soybean falls by 13 (±1)%, 11 (±8)%, 3 (±5)%, and 17 (±2)% over 5 y. Total single-year losses of 12 (±4)% quadruple the largest observed historical anomaly and exceed impacts caused by historic droughts and volcanic eruptions. Colder temperatures drive losses more than changes in precipitation and solar radiation, leading to strongest impacts in temperate regions poleward of 30°N, including the United States, Europe, and China for 10 to 15 y. Integrated food trade network analyses show that domestic reserves and global trade can largely buffer the production anomaly in the first year. Persistent multiyear losses, however, would constrain domestic food availability and propagate to the Global South, especially to food-insecure countries. By year 5, maize and wheat availability would decrease by 13% globally and by more than 20% in 71 countries with a cumulative population of 1.3 billion people. In view of increasing instability in South Asia, this study shows that a regional conflict using <1% of the worldwide nuclear arsenal could have adverse consequences for global food security unmatched in modern history.

54 ENVIRONMENTAL SCIENCES↗

Process Anomaly Detection for Sparsely Labeled Events in Nuclear Power Plants

An essential aspect of online monitoring, subtle anomaly detection increases the detection lead time for equipment failure and enables a nuclear power plant (NPP) to mitigate unexpected partial or full outages, resulting in significant cost saving to the plant. Once an anomaly is detected by plant staff, its cause and severity are investigated. Because the vast majority of anomalies require some level of investigation, including some that require time-consuming examination, before they are passed over to the engineering organization for further analysis, plants are often equipped with tools to assist the staff in performing anomaly detection. Those tools operate as a black box and are often based on statistical methods that establish sensor correlations using preconfigured mathematical models and flag correlation deviations as anomalies. Due to the number of anomalies detected at a given NPP on a daily basis, a significant number of flagged anomalies usually await examination for days or weeks. A primary cause of this backlog is that the methods used by the tools generate many false positives. Though this is usually attributed to oversensitive model settings due to very narrow normal operation bands, it can also be associated with the model development being inadequate for the process being monitored, or with missing model inputs that could have explained misclassified positives. The performance of anomaly detection tools impacts their plant acceptance and utilization, especially when the effort to address false positives generated by the tool depletes the value or cost saved by using that tool. Thus, means to advance anomaly detection performance have been investigated by the Department of Energy’s Light Water Reactor Sustainability program. Previous and ongoing efforts have targeted unsupervised machine-learning (ML) methods, which do not require the labeling of any data fed into the ML model. By contrast, in supervised anomaly detection methods, every data point is labeled as either a normal or abnormal process condition, and the model is trained to replicate the classification process. Supervised methods usually outperform unsupervised methods, due to the added value in differentiating normal from anomalous states of the monitored process. An NPP’s corrective action program requires it to track and document, via a dedicated report, the resolution of any issues that occur within the plant. Once created, each report is reviewed by a plant screening committee, and several classifications and decisions are made. Recently, a collaborating NPP developed an artificial intelligence and ML-based classifier to categorize a condition report (CR) into classes that can serve to label the data as normal or anomalous. Applying CRs as labels represents a semi-supervised use case. Semi-supervised ML assumes that labels exist for some data points (i.e., labeled anomalies, in this case) but not for the rest. In this effort, semi-supervised ML methods were used to fuse data from CRs with anomaly detection methods in order to test the hypothesis that partially labeled anomalies would improve the accuracy of the anomaly detection methods. Specifically, two methods were used. The first is the deep Semi-supervised Anomaly Detection (deep SAD) method, which can handle labels ranging from fully unsupervised to fully supervised cases. The second is a newly designed ML method developed specifically for this effort and referred to as the high-order feature (HOF)-based method. To evaluate these two methods in controlled environments, synthetic data generators were developed and used. The first datasets used a spring-mass-damper (SMD) system simulator commonly found in mechanical engineering references. This was used to create two use cases: a one- and a three-mass system. Anomalies were introduced by changing the spring and damper coefficients while the system was actuated by random forces. The second datasets used the commercial Dymola-Modelica software to build a simplified nuclear reactor model. Anomalies were added in the form of corrupted sensor readings and/or control commands. The deep SAD method was tested using the SMD system, while the HOF method was tested using both datasets. Application of the deep SAD semi-supervised ML method demonstrated that labels can generate increased confidence in detecting true anomalies. This helped increase the number of true positives and decrease the number of false negatives—something that would aid in addressing the backlog of possible anomalies. Application of the HOF method demonstrated that labels can aid in down selecting from a candidate set of features to a more optimal subset in order to better differentiate between normal and anomalous conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing and Implementing New Waste Chemistry Controls for Hanford's Double-Shell Tanks - 20041

Waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the Savannah River Site (SRS). The controls were established based on a combination of SRS chemistry limits and corrosion testing results. Conditions in the Hanford DSTs have changed over time, with the temperature in the majority of the DSTs dropping below 50 deg. C. Testing indicated that the original chemistry control specification and SCC testing performed in 2010 did not protect against pitting corrosion mechanisms - what is believed to have caused the failure of tank 241-AY-102. New waste chemistry controls are necessary to protect the DSTs from both SCC and pitting corrosion. Savannah River National Laboratory (SRNL), with input from the Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG), performed a statistically based investigation of nitrate and halide ion induced pitting corrosion. The investigation was intended to develop a comprehensive waste chemistry envelope that minimizes the risk of both SCC and pitting caused by halide and nitrate ions. The waste chemistry envelope needed to be robust enough to address future waste retrieval and process changes which could significantly change the waste composition of the DSTs. The experimental design allowed the statistically significant ions and their effect on pitting corrosion to be determined. SRNL developed the 'pitting factor' which is an empirical relationship between the statistically significant inhibitive species (hydroxide, and nitrite), and pitting inducing species (nitrate, chloride, and fluoride). The coefficients are weighted factors that show the degree of influence the species have on the propensity for pitting. New waste chemistry control limits were recommended by SRNL, and concurred with by the TIEP CSG, that incorporated the pitting factor along with other limits. The controls developed to reduce the risk of pitting corrosion were evaluated to determine if they also protected against SCC. Hundreds of test results were reviewed and compared against the proposed limits. With the exception of one test result, instances where cracking was observed corresponded to chemistry that was outside of the proposed limits - indicating that the chemistry controls developed for pitting also adequately addressed SCC concerns. Existing tank composition estimates were evaluated against the new chemistry controls - three current tank chemistries are suspect, and may not meet the new chemistry control requirements. These included the interstitial liquid (liquid associated with solids) of DSTs 241-AN-102, 241-AN-106, 241-AN-107, and 241-AY-101. Measures are ongoing to evaluate the tanks with the suspect chemistry. These include varying combinations of: performing additional evaluations (history of use, modeling); DST specific laboratory testing; and, pursuing core samples of the DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗