Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure cause”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Operational Experience and Development of a Reliability Model for the ATR Demineralizer System (Slides)

The Advanced Test Reactor (ATR) is a light water reactor with aluminum clad driver fuel. Strict limits are implemented on pH, conductivity, and filterable solids to assure the performance of the driver fuel limit corrosion of the primary coolant system (PCS) pressure boundary components. A bypass demineralizer system is used to maintain PCS coolant within allowable bands for each of the aforementioned variables. Unlike many other reactors, the ATR does not have a filtration system. As such, failure of ion exchange resin in the bypass demineralizer can defeat the purpose of the system and result in high filterable solids in the PCS. Power operations with high filterable solids is prohibited by a technical safety requirement. This paper discusses recent failures of the ATR bypass demineralizer system. The testing and analysis done to deduce the cause of the failures is covered, as well as short term mitigative steps that were taken. To prevent the likelihood of future issues, historical data from the ATR and industry is used to develop a reliability model of the ATR bypass demineralizer system. Evidence of radiolytic decomposition of ion exchange resin was found in the cause investigation. As such, special attention is given to ion exchange resin failure due to high radiation environments. The reliability model is used to develop the ATR testing and maintenance program. Specifically, limits on resin service life are discussed.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Stress failure of pulmonary capillaries: role in lung and heart disease

Pulmonary capillaries have extremely thin walls to allow rapid exchange of respiratory gases across them. Recently it has been shown that the wall stresses become very large when the capillary pressure is raised, and in anaesthetised rabbits, ultrastructural damage to the walls is seen at pressures of 40 mm Hg and above. The changes include breaks in the capillary endothelial layer, alveolar epithelial layer, and sometimes all layers of the wall. The strength of the thin part of the capillary wall can be attributed to the type IV collagen in the extracellular matrix. Stress failure of pulmonary capillaries results in a high-permeability form of oedema, or even frank haemorrhage, and is apparently the mechanism of neurogenic pulmonary oedema and high-altitude pulmonary oedema. It also explains the exercise-induced pulmonary haemorrhage that occurs in all racehorses. Several features of mitral stenosis are consistent with stress failure. Overinflation of the lung also leads to stress failure, a common cause of increased capillary permeability in the intensive care environment. Stress failure also occurs if the type IV collagen of the capillary wall is weakened by autoantibodies as in Goodpasture's syndrome. Neutrophil elastase degrades type IV collagen and this may be the starting point of the breakdown of alveolar walls that is characteristic of emphysema. Stress failure of pulmonary capillaries is a hitherto overlooked and potentially important factor in lung and heart disease.

Review↗

Morphological transitions on lithium metal anodes.

Coin cells were prepared using a metallic lithium anode, a Li{sub 4}Ti{sub 5}O{sub 12} cathode, and a 1.2 M LiPF{sub 6}/ethylene carbonate:ethyl methyl carbonate (30:70 wt %) electrolyte. The cells were cycled galvanostatically between 1 and 2 V vs Li/Li{sup +} (i=2.0 mA/cm{sup 2}) at a 2C rate. After a specific number of cycles, the cells were disassembled and the morphology of the lithium anode was characterized using scanning electron microscopy. It was observed that the surface morphology of the lithium metal electrode transitioned from a flat and smooth morphology to a microscopically rugged structure that shows three distinct layers: a top dendritic layer, an intermediate porous layer, and a residual metallic lithium layer. Morphological and electrochemical evidence points to the depletion of the electrolyte and the active metallic lithium that reacted to produce the porous layer as the most likely cause of cell failure under the conditions studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of advanced automatic PET segmentation methods using nonspherical thin-wall inserts

Purpose: The use of positron emission tomography (PET) within radiotherapy treatment planning requires the availability of reliable and accurate segmentation tools. PET automatic segmentation (PET-AS) methods have been recommended for the delineation of tumors, but there is still a lack of thorough validation and cross-comparison of such methods using clinically relevant data. In particular, studies validating PET segmentation tools mainly use phantoms with thick plastic walls inserts of simple spherical geometry and have not specifically investigated the effect of the target object geometry on the delineation accuracy. Our work therefore aimed at generating clinically realistic data using nonspherical thin-wall plastic inserts, for the evaluation and comparison of a set of eight promising PET-AS approaches. Methods: Sixteen nonspherical inserts were manufactured with a plastic wall of 0.18 mm and scanned within a custom plastic phantom. These included ellipsoids and toroids derived with different volumes, as well as tubes, pear- and drop-shaped inserts with different aspect ratios. A set of six spheres of volumes ranging from 0.5 to 102 ml was used for a baseline study. A selection of eight PET-AS methods, written in house, was applied to the images obtained. The methods represented promising segmentation approaches such as adaptive iterative thresholding, region-growing, clustering and gradient-based schemes. The delineation accuracy was measured in terms of overlap with the computed tomography reference contour, using the dice similarity coefficient (DSC), and error in dimensions. Results: The delineation accuracy was lower for nonspherical inserts than for spheres of the same volume in 88% cases. Slice-by-slice gradient-based methods, showed particularly lower DSC for tori (DSC < 0.5), caused by a failure to recover the object geometry. The region-growing method reached high levels of accuracy for most inserts (DSC > 0.76 except for tori) but showed the largest errors in the recovery of pears and drops dimensions (higher than 10% and 30% of the true length, respectively). Large errors were visible for one of the gradient-based contouring methods when delineating drop-shaped inserts. Low DSC due to systematic underestimation of the volumes was observed for our fuzzy clustering method when using nonspherical inserts. The adaptive iterative thresholding method produced the highest DSC score on our nonspherical dataset (DSC > 0.83, except for tori) and showed robustness to the insert geometry. Conclusions: This study investigated the accuracy of eight PET-AS methods for the delineation of objects with a range of nonspherical geometries. The authors’ results confirmed the robustness of some segmentation approaches, but also showed the weaknesses of some of the other methods implemented, which were not observed with spherical inserts. This work therefore highlights the importance of using a variety of thin-wall inserts with complex geometries for the validation of PET-AS methods and provided useful information for further development of the methods tested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertical Extraction Process Implemented at the 118-K-1 Burial Ground for Removal of Irradiated Reactor Debris from Silo Structures - 12431

The primary objective of a remediation project is the safe extraction and disposition of diverse waste forms and materials. Remediation of a solid waste burial ground containing reactor hardware and irradiated debris involves handling waste with the potential to expose workers to significantly elevated dose rates. Therefore, a major challenge confronted by any remediation project is developing work processes that facilitate compliant waste management practices while at the same time implementing controls to protect personnel. Traditional burial ground remediation is accomplished using standard excavators to remove materials from trenches and other excavation configurations often times with minimal knowledge of waste that will be encountered at a specific location. In the case of the 118-K-1 burial ground the isotopic activity postulated in historic documents to be contained in vertical cylindrical silos was sufficient to create the potential for a significant radiation hazard to project personnel. Additionally, certain reported waste forms posed an unacceptably high potential to contaminate the surrounding environment and/or workers. Based on process knowledge, waste management requirements, historic document review, and a lack of characterization data it was determined that traditional excavation techniques applied to remediation of vertical silos would expose workers to unacceptable risk. The challenging task for the 118-K-1 burial ground remediation project team then became defining an acceptable replacement technology or modification of an existing technology to complete the silo remediation. Early characterization data provided a good tool for evaluating the location of potential high exposure rate items in the silos. Quantitative characterization was a different case and proved difficult because of the large diameter of the silos and the potential for variable density of attenuating soils and waste forms in the silo. Consequently, the most relevant information supporting job planning and understanding of the conditions was the data obtained from the gross gamma meter that was inserted into each casing to provide a rough estimate of dose rates in the tubes. No added value was realized in attempting to quantify the source term and/or associate the isotopic activity with a particular actual waste form (e.g., sludge). Implementing the WRM system allowed monitoring of worker and boundary exposure rates from a distance, maintaining compliance with ALARA principles. This system also provided the project team early knowledge of items being removed that had high exposure rates associated with them, thus creating an efficient method of acknowledging an issue and arriving at a solution prior to having an upset condition. An electronic dosimeter with telemetry capability replaced the excavator mounted AMP-100 system approximately half way through remediation of the silos. Much higher connectivity efficiency was derived from this configuration. Increasing the data feed efficiency additionally led to less interruption of the remediation effort. Early in system testing process a process handicap on the excavator operator was acknowledged. A loss of depth perception resulted when maneuvering the excavator and bucket using the camera feed to an in-cab monitor. Considerable practice and mock-up testing allowed this handicap to be overcome. The most significant equipment failures involved the cable connection to the camera mounted between the clamshell bucket jaws and the video splitter in the excavator cab. Rotation of the clamshell bucket was identified as the cause of cable connection failures because of the cyclic twisting motion and continuous mechanical jarring of the connection. In-cab vibration was identified as the culprit in causing connection failures of the video splitter. While these failures were repaired, substantial production time was lost. Ultimately, the decision was made to purchase a second cable and higher quality video splitter eliminate the down time. An engineering improvement for future operations would be inserting cable pig tails at more stressed cable connection points to facilitate rapid change out of the cable should that be required. Overall, the system performed better than expected in a safe and efficient manner. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Function reconsideration of indium bump in InSb IRFPAs

Indium bumps are generally accepted to possess functions of electrical connection, mechanical support and heat transfer in flip-chip devices. After comparing the distribution of stress components along different paths in InSb infrared focal plane arrays (IRFPAs), we ascertain that local enhancement effects of the stress components are remarkable in regions where the indium bumps are. More specifically, the local enhanced tensile stress in InSb chip connected with the indium bumps can lead to the local fracture of the InSb chip, and the locally enhanced shear and peeling stresses may give rise to the local interfacial delamination between the InSb chip and the indium bumps. These inferences are confirmed by the observed local failure characteristics, such as the distribution of the local delamination, the distribution of the crack widths, and the distribution of the cracks. In addition, the simulated Z-component strain distribution in InSb IRFPAs is also consistent with the backside surface profile of the InAs/GaSb IRFPAs fabricated in America with the identical structure, that is, the InSb chip glued with the indium bumps is concave downward, and the InSb chip glued with the underfill is convex upward. Judging from all these confirmed simulation results, we are confident that the indium bumps play a pivotal role in inducing the local failure of InSb IRFPAs. So the role of the indium bumps in causing the local failure of InSb IRFPAs needs to be supplemented and emphasized to comprehensively evaluate the structural reliability of InSb IRFPAs.

42 ENGINEERING↗

Investigation of electromigration in In{sub 2}Se{sub 3} nanowire for phase change memory devices

The decomposition of In{sub 2}Se{sub 3} nanowire phase change memory devices during current-driving operation was investigated. The devices were subjected to thermal/electrical stress with current density and electric field during the reset operation at 0.24–0.38 MA/cm{sup 2} and 5.3–6.4 kV/cm, respectively. After multiple operation cycles, a change in morphology and composition of the In{sub 2}Se{sub 3} nanowire was observed and led to the device failure. The transmission electron microscopy and energy dispersive analysis indicate that electromigration causes the catastrophic failure by void formation where In atoms migrate toward the cathode and Se atoms migrate toward the anode depending on their electronegativities.

36 MATERIALS SCIENCE↗

Assessment of the Analysis Capability for Core-wide PWR Pellet-Clad Interaction (PCI) Screening

The Level 1 Milestone, L1:CASL.P13.03, “Assess the analysis capability for core-wide PWR Pellet-Clad Interaction (PCI) screening and demonstrate detailed 3-D analysis on selected sub-region.”, has been completed by the Fuels, Materials and Chemistry and Physics Integration focus areas of CASL. This report illustrates the application of VERA simulation to PWR core-wide PCI screening, with emphasis on the multi-dimensional analysis capabilities of BISON fuel performance code. The VERA codes utilized in this effort are: the fuel performance code BISON and the VERA-CS sub-element, which combines the neutron transport code MPACT and the thermal-hydraulics code COBRA-TF (CTF). The target reactor for this work is Watts Bar Unit 1, Cycles 6 and 7, selected on the basis that PCI failures had occurred during power start-up in both cycles, despite the moderate power levels, which offered an interesting test of the code’s veracity and a particularly challenging condition for this Milestone’s assessment. The analysis began by performing BISON-IN-VERA, i.e. VERA-CS + BISON, quarter-core depletion calculations, from which limiting assemblies and limiting fuel rods were selected using a four-parameter selection criterion: high power, high temperature, small gap thickness and high cladding hoop stress. The cladding material being Westinghouse Zirlo, the analysis utilized a new material model developed for this cladding by CASL’s FMC team using open literature sources. The VERA-CS + BISON analysis resulted in identifying 51 limiting rods as candidates for more detailed PCI analysis using stand-alone BISON, employing local 2D and 3D geometric models. This local-effects BISON analysis provided detailed PCI failure assessment, considering the impact of power histories on the two potential sources of PCI failure: the classical SCC-PCI and the missing pellet surface geometry MPS-PCI. The 51-rod analyses of Watts Bar Unit 1 cycle 6 and 7 revealed that the classical SCC-PCI stress levels were well below the failure threshold determined in a previous CASL study, which implicated the other mode of failure, namely MPS-PCI. Considering MPS defects to be the root cause for the failure, the local-effects calculations was repeated using MPS defect sizes equal to and larger than Westinghouse quality assurance standards. Initial results of this new analysis showed a significant increase in the cladding stress, indicating that an MPS may have been present in cycle 6 and 7 for the failure to occur. In order to determine the size of MPS needed for cycle 6 and 7 rods to fail, a sensitivity study using 2-D and 3-D models was performed. The results showed cladding hoop stresses, while remaining below the failure level for an MPS of equal size to the acceptance standard, continued to increase as the size of the MPS increased. This report has demonstrated the use of BISON, in consort with VERA’s simulation methodology, for core-wide PCI failure screening capability. Utilizing this demonstration, and emulating the PCI margin analysis methodology developed in the EPRI PCI guidelines, BISON-IN-VERA simulation can be used very effectively to develop core power histories to minimize PCI failure potential.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary results: Root cause investigation of orbital anomalies and failures in NASA standard 50 ampere-hour nickel-cadmium batteries

Two lots of NASA standard 50 A.H. Ni-Cd battery cells, manufactured by Gates Aerospace Batteries and built into batteries by McDonnell Douglas, have experienced significant performance problems. The two lots were used on the Compton Gamma Ray Observatory and the Upper Atmosphere Research Satellite. Both of these satellites are Low Earth Orbital (LEO) satellites containing batteries on a parallel bus charged to NASA standard V/T curves using a NASA standard power regulator. The following preliminary conclusions were reached: (1) several plate and cell parameters have migrated within their spec limits over the years (in some cases, from one extreme to the other); (2) several parametric relationships, not generally monitored and therefore not under specification control, have also migrated over the years; (3) many of these changes appear to have taken place as a natural consequence of changes in GE/GAB materials and processes; (4) several of these factors may be 'conspiring' to aggravate known cell failure mechanisms (factors such as heavier plate, less teflon and/or less-uniform teflon, and less electrolyte) but all are still in spec (where specs exist); (5) the weight of the evidence collected to characterize the anomalies and to characterize the negative electrode itself, strongly suggests that alterations to the structure, composition, uniformity, and efficiency of the negative electrode are at the heart of the battery performance problems currently being experienced; and (6) further investigation at all levels (plate, cell, battery, and system) continues to be warranted.

Toft, Mark R.↗

Evaluation of Contact Separation Force Testing as a Screening Methodology for Electrical Socket Contacts

During system level testing intermittent and permanent open circuit failures of mated, crimp removable, electrical contact pairs were experienced. The root cause of the failures was determined to be low (but not zero) contact forces applied by the socket contact tines against the engaging pin. The low contact force reduces the effectiveness of the wiping action of the socket tines against the pin. The observed failure mode may be produced when insufficient wiping during mate, demate and small relative movement in use allows for the accumulation of debris or insulating films that electrically separate the contact pair. The investigation identified at least three manufacturing process control problems associated with the socket contacts that enabled shipment of contacts susceptible to developing low contact forces: (1) Improper heat treatment of the socket tines resulting in plastic rather than elastic behavior; (2) Overly thinned socket tines at their base resulting in reduced pin retention forces; (3) Insufficient screening tests to identify parts susceptible to the aforementioned failure mechanisms. The results from an extensive screening program of socket contacts utilizing the industry standard contact separation force test procedures are described herein. The investigation shows this method to be capable of identifying initially weak sockets. However, sockets whose contact retention forces may degrade during use may not be screened out by pin retention testing alone. Further investigations are required to correlate low contact retention forces with increased electrical contact resistance in the presence of insulating films that may accumulate in the use environment.

Christopher Green↗

Building Reliable Printed Circuit Boards - the Lessons Learned

"Printed circuit boards (PCBs) are the baseline for electronics manufacturing upon which electronic components are mounted and formed into electronic systems. PCBs are used in a variety of electronic circuits from simple one-transistor amplifiers to large super computers. A PCB serves three main functions: 1) it provides the necessary mechanical support for the components in the circuit 2) it provides the necessary electrical interconnections, and 3) it bears some form of legend which identifies the components it carries. The failure modes on the PCBs can be categorized in a hierarchical structure, in which the mechanisms and causes are site or location dependant. This one day workshop will discuss a variety of failure mechanisms that effect the functionality of PCBs. These mechanisms can be related to how PCB materials are selected, PCBs are designed, manufactured, tested and used in the field conditions. The workshop will begin with an overview of PCB manufacturing, materials and processes. With the help of examples and case studies, a wide range of failure mechanisms will be discussed, case studies are focused on digital circuits, however some failures in analog, double sided boards are also presented. The workshop then provides the guideline for selection of methodologies for identifying potential failure mechanisms based on the failure history and how a systematic root cause failure analysis of the PCB can result in prevention of future issues."

Sood, Bhanu↗

Small vulnerable sets determine large network cascades in power grids

The understanding of cascading failures in complex systems has been hindered by the lack of realistic large-scale modeling and analysis that can account for variable system conditions. Using the North American power grid, we identified, quantified, and analyzed the set of network components that are vulnerable to cascading failures under any out of multiple conditions. We show that the vulnerable set consists of a small but topologically central portion of the network and that large cascades are disproportionately more likely to be triggered by initial failures close to this set. These results elucidate aspects of the origins and causes of cascading failures relevant for grid design and operation and demonstrate vulnerability analysis methods that are applicable to a wider class of cascade-prone networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Software dependability in the Tandem GUARDIAN system

Based on extensive field failure data for Tandem's GUARDIAN operating system this paper discusses evaluation of the dependability of operational software. Software faults considered are major defects that result in processor failures and invoke backup processes to take over. The paper categorizes the underlying causes of software failures and evaluates the effectiveness of the process pair technique in tolerating software faults. A model to describe the impact of software faults on the reliability of an overall system is proposed. The model is used to evaluate the significance of key factors that determine software dependability and to identify areas for improvement. An analysis of the data shows that about 77% of processor failures that are initially considered due to software are confirmed as software problems. The analysis shows that the use of process pairs to provide checkpointing and restart (originally intended for tolerating hardware faults) allows the system to tolerate about 75% of reported software faults that result in processor failures. The loose coupling between processors, which results in the backup execution (the processor state and the sequence of events) being different from the original execution, is a major reason for the measured software fault tolerance. Over two-thirds (72%) of measured software failures are recurrences of previously reported faults. Modeling, based on the data, shows that, in addition to reducing the number of software faults, software dependability can be enhanced by reducing the recurrence rate.

Lee, Inhwan↗

Application of Fault Containment Principles to EMC

A hardware fault in aerospace is an undesired response to a designed engineering function in hardware. Therefore, in aerospace systems fault management is of prime importance. An important aspect of hardware faults is fault propagation. Fault propagation (also known as failure propagation) is a condition where a fault will not only produce an undesired hardware response, at its location of origin, but the fault will also propagate to other interfaced hardware and cause additional faults, or failures. Fault containment is necessary to avoid fault propagation. A fault containment region is an electronic or electromechanical region within a given hardware assembly where a fault in that region will not physically propagate to other regions of the assembly, and beyond. Rather, the fault will cause a functional failure of the hardware, where the fault occurred, without causing any additional propagated failures. Electromagnetic Compatibility (EMC) is a desired state in aerospace hardware. Electromagnetic Interference (EMI) in aerospace hardware is a fault condition of EMC. Like other faults EMI can also propagate to other aerospace hardware unless it occurs inside an EMI containment region. The paper addresses the concepts of fault containment region and introduces the concept of EMI containment region with examples of both.

Perez, Reinaldo↗

Fill Factor Loss in Fielded Photovoltaic Modules Due to Metallization Failures, Characterized by Luminescence and Thermal Imaging

Understanding the causes of photovoltaic module failure in the field can be achieved using spatially-resolved imaging tools in combination with current-voltage (IV) characterization. We evaluate 23 field-degraded modules by comparing their IV characteristics with module images obtained by electroluminescence, photoluminescence, UV-fluorescence, and dark lock-in thermography. We identify primarily metallization failures (metallization series resistance, solder point heating, broken fingers, disrupted interconnects) in these modules that has led to a severe drop in the fill factor and up to 35% power loss over only 2 years of deployment.

14 SOLAR ENERGY↗

Improved Collectors for High Power Gyrotrons

High power gyrotrons are used for electron cyclotron heating, current drive and parasitic mode suppression in tokamaks for fusion energy research. These devices are crucial for successful operation of many research programs around the world, including the ITER program currently being constructed in France. Recent gyrotron failures resulted from cyclic fatigue of the copper material used to fabricated the collectors. The techniques used to collect the spent beam power is common in many gyrotrons produced around the world. There is serious concern that these tubes may also be at risk from cyclic fatigue. This program addresses the cause of the collector failure. The Phase I program successfully demonstrated feasibility of a mode of operation that eliminates the cyclic operation that caused the failure. It also demonstrated that new material can provide increased lifetime under cyclic operation that could increase the lifetime by more than on order of magnitude. The Phase II program will complete that research and develop a collector that eliminates the fatigue failures. Such a design would find application around the world.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗