Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Chandra Observations of Comet 2P/Encke 2003: First Detection of a Collisionally Thin, Fast Solar Wind Charge Exchange System

We report the results of 15 hr of Chandra observations of comet 2P/Encke 2003 on November 24. X-ray emission from comet Encke was resolved on scales of 500-40,000 km, with unusual morphology due to the presence of a low-density, collisionally thin (to charge exchange) coma. A light curve with peak-to-peak amplitude of 20% consistent with a nucleus rotational period of 11.1 hr was found, further evidence for a collisionally thin coma. We confirm emission lines due to oxygen and neon in the 800-1000 eV range but find very unusual oxygen and carbon line ratios in the 200-700 eV range, evidence for low-density, high effective temperature solar wind composition. We compare the X-ray spectral observation results to contemporaneous measurements of the coma and solar wind made by other means and find good evidence for the dominance of a postshock bubble of expanding solar wind plasma, moving at 600 km/s with charge state composition between that of the "fast" and "slow" solar winds.

Lisse, C. M.↗

Monogroove liquid heat exchanger

A liquid supply control is disclosed for a heat transfer system which transports heat by liquid-vapor phase change of a working fluid. An assembly (10) of monogroove heat pipe legs (15) can be operated automatically as either heat acquisition devices or heat discharge sources. The liquid channels (27) of the heat pipe legs (15) are connected to a reservoir (35) which is filled and drained by respective filling and draining valves (30, 32). Information from liquid level sensors (50, 51) on the reservoir (35) is combined (60) with temperature information (55) from the liquid heat exchanger (12) and temperature information (56) from the assembly vapor conduit (42) to regulate filling and draining of the reservoir (35), so that the reservoir (35) in turn serves the liquid supply/drain needs of the heat pipe legs (15), on demand, by passive capillary action (20, 28).

Brown, Richard F.↗

Thermal Structure of the TTL and Its Relation to Stratospheric-Tropospheric Exchange of Water

This document describes the annual cycle of the trajectory track line (TTL) fine scale thermal structure as captured by global positioning system (GPS) radio occultation and the pressure levels of the East Meets West Foundation (EMWF) weather analysis. This annual cycle is compared to the annual cycle in water concentrations measured by the HALogen Occultation Experiment (HALOE). A comparison between saturation mixing ratios at the temperatures captured by GPS radio occultation and HALOE concentrations of water vapor shows an annual cycle that is dominated by supersaturation in the boreal winter months, when the upward mass fluxes are larger, and subsaturation in the summer. The longitudinal dependence of these cycles is discussed as well as the possible implications for the seasonality of stratospheric-troposheric exchanges of water.

climates↗

Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger with Bypass Setpoint Temperature Control

Spacecraft radiators are sized for their maximum heat load in their warmest thermal environment, but must operate at reduced heat loads and in colder environments. For systems where the radiator environment can be colder than the working fluid freezing temperature, radiator freezing becomes an issue. Radiator freezing has not been a major issue for the Space Shuttle and the International Space Station (ISS) active thermal control systems (ATCSs) because they operate in environments that are warm relative to the freezing point of their external coolants (Freon-21 and ammonia, respectively). For a vehicle that lands at the Lunar South Pole, the design thermal environment is 215K, but the radiator working fluid must also be kept from freezing during the 0 K sink of transit. A radiator bypass flow control design such as those used on the Space Shuttle and ISS requires more than 30% of the design heat load to avoid radiator freezing during transit - even with a very low freezing point working fluid. By changing the traditional ATCS architecture to include a regenerating heat exchanger inboard of the radiator and by using a regenerator bypass flow control valve to maintain system setpoint, the required minimum heat load can be reduced by more than half. This gives the spacecraft much more flexibility in design and operation. The present work describes the regenerator bypass ATCS setpoint control methodology. It includes analytical results comparing the performance of this system to the traditional radiator bypass system. Finally, a summary of the advantages of the regenerator bypass system are presented.

Ungar, Eugene K.↗

Evaluation of a Pilot Surveillance System: Health and Environment Linked for Information Exchange in Atlanta (HELIX-Atlanta)

CDC and its partners established the Health and Environment Linked for Information Exchange, Atlanta (HELIX-Atlanta) demonstration project, to develop linking and analysis methods that could be used by the National Environmental Public Health Tracking (EPHT) Network. Initiated in October 2003, the Metropolitan Atlanta-based collaborative conducted four projects: asthma and particulate air pollution, birth defects and ozone and particulate air pollution, childhood leukemia and traffic emissions, and children's blood lead testing and neighborhood risk factors for lead poisoning. This report provides an overview of the HELIX-Atlanta projects' goals, methods and outcomes. We discuss priority attributes and common issues and challenges and offer recommendations for implementation of the nascent national environmental public health tracking network.

Meyer, P.↗

Determining Regional Arctic Tundra Carbon Exchange: A Bottom-Up Approach

This viewgraph presentation reviews the carbon atmospheric exchange with Arctic tundra. In the Arctic the ecosystem has been a net carbon sink. The project investigates the question of how might climate warming effect high latitude ecosystems and the Earth ecosystems and how to measure the changes.

Huemmrich, Fred↗

Observation of Solar Wind Charge Exchange Emission from Exospheric Material in and Outside Earth's Magnetosheath

A long XMM-Newton exposure is used to observe solar wind charge exchange (SWCX) emission from exospheric material in and outside Earth s magnetosheath. The light curve of the O VII (0.5-0.62 keV) band is compared with a model for the expected emission, and while the emission is faint and the light curve has considerable scatter, the correlation is significant to better than 99.9%. This result demonstrates the validity of the geocoronal SWCX emission model for predicting a contribution to astrophysical observations to a scale factor of order unity (1.36). The results also demonstrate the potential utility of using X-ray observations to study global phenomena of the magnetosheath which currently are only investigated using in situ measurements.

Snowden, S. L.↗

Solar Wind Change Exchange from the Magnetosheath

We report the results of a long (approximately 100 ks) XMM-Newton observation designed to observe solar wind charge exchange emission (SWCX) from Earth's magnetosheath. By luck, the observation took place during a period of minimal solar wind flux so the SWCX emission was also minimal. Never-the-less, there is a significant if not stunning correlation between the observed O VIII count rate and our model for magnetosheath emission. We also report on the observed O VII and O VII emission.

Snowden, Steve↗

Investigation of Liquid Metal Heat Exchanger Designs for Fission Surface Power

Fission surface power is an option for future Moon and Mars surface missions. High power nuclear reactor heated Stirling convertors are an option to provide reliable power for long duration outpost operations. This report investigates various design approaches for the liquid metal to acceptor heat exchange and clarifies the details used in the analysis.

Dyson, Rodger W.↗

Health and Environment Linked for Information Exchange in Atlanta (HELIX-Atlanta): A Pilot Tracking System

Objectives. To provide an overview of four environmental public health surveillance projects developed by CDC and its partners for the Health and Environment Linked for Information Exchange, Atlanta (HELIX-Atlanta) and to illustrate common issues and challenges encountered in developing an environmental public health tracking system. Methods. HELIX-Atlanta, initiated in October 2003 to develop data linkage and analysis methods that can be used by the National Environmental Public Health Tracking Network (Tracking Network), conducted four projects. We highlight the projects' work, assess attainment of the HELIX-Atlanta goals and discuss three surveillance attributes. Results. Among the major challenges was the complexity of analytic issues which required multidiscipline teams with technical expertise. This expertise and the data resided across multiple organizations. Conclusions:Establishing formal procedures for sharing data, defining data analysis standards and automating analyses, and committing staff with appropriate expertise is needed to support wide implementation of environmental public health tracking.

Rickman, Doug↗

Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water

A nanoporous membrane is used for the pervaporation process in which potable water is maintained, at atmospheric pressure, on the feed side of the membrane. The water enters the non-pervaporation (NPV) membrane device where it is separated into two streams -- retentate water and permeated water. The permeated pure water is removed by applying low vapor pressure on the permeate side to create water vapor before condensation. This permeated water vapor is subsequently condensed by coming in contact with the cool surface of a heat exchanger with heat being recovered through transfer to the feed water stream.

Tsai, Chung-Yi↗

XTCE. XML Telemetry and Command Exchange Tutorial

An XML Telemetry Command Exchange (XTCE) tutoral oriented towards packets or minor frames is shown. The contents include: 1) The Basics; 2) Describing Telemetry; 3) Describing the Telemetry Format; 4) Commanding; 5) Forgotten Elements; 6) Implementing XTCE; and 7) GovSat.

Rice, Kevin↗

A Comparison of Flow-Through Versus Non-Flow-Through Proton Exchange Membrane Fuel Cell Systems for NASA's Exploration Missions

As part of the Exploration Technology Development Program (ETDP) under the auspices of the Exploration Systems Mission Directorate (ESMD), NASA is developing both primary fuel cell power systems and regenerative fuel cell (RFC) energy storage systems within the fuel cell portion of the Energy Storage Project. This effort is being led by the NASA Glenn Research Center (GRC) in partnership with the NASA Johnson Space Center (JSC), Jet Propulsion Laboratory (JPL), NASA Kennedy Space Center (KSC), and industrial partners. The development goals are to improve fuel cell and electrolysis stack electrical performance, reduce system mass, volume, and parasitic power requirements, and increase system life and reliability. A major focus of this effort has been the parallel development of both flow-through and non-flow-through proton exchange membrane (PEM) primary fuel cell power systems. The plan has been, at the appropriate time, to select a single primary fuel cell technology for eventual flight hardware development. Ideally, that appropriate time would occur after both technologies have achieved a technology readiness level (TRL) of six, which represents an engineering model fidelity PEM fuel cell system being successfully tested in a relevant environment. Budget constraints in fiscal year 2009 and beyond have prevented NASA from continuing to pursue the parallel development of both primary fuel cell options. Because very limited data exists for either system, a toplevel, qualitative assessment based on engineering judgement was performed expeditiously to provide guidance for a selection. At that time, the non-flow-through technology was selected for continued development because of potentially major advantages in terms of weight, volume, parasitic power, reliability, and life. This author believes that the advantages are significant enough, and the potential benefits great enough, to offset the higher state of technology readiness of flow-through technology. This paper summarizes the technical considerations which helped form the engineering judgement that led to the final decision.

Hoberecht, Mark A.↗

Hybrid Heat Exchangers

A hybrid light-weight heat exchanger concept has been developed that uses high-conductivity carbon-carbon (C-C) composites as the heat-transfer fins and uses conventional high-temperature metals, such as Inconel, nickel, and titanium as the parting sheets to meet leakage and structural requirements. In order to maximize thermal conductivity, the majority of carbon fiber is aligned in the fin direction resulting in 300 W/m.K or higher conductivity in the fin directions. As a result of this fiber orientation, the coefficient of thermal expansion (CTE) of the C-C composite in both non-fiber directions matches well with the CTE of various high-temperature metal alloys. This allows the joining of fins and parting sheets by using high-temperature braze alloys.

Tu, Jianping Gene↗

Evolution of the Tropical Cyclone Integrated Data Exchange And Analysis System (TC-IDEAS)

The Tropical Cyclone Integrated Data Exchange and Analysis System (TC-IDEAS) is being jointly developed by the Jet Propulsion Laboratory (JPL) and the Marshall Space Flight Center (MSFC) as part of NASA's Hurricane Science Research Program. The long-term goal is to create a comprehensive tropical cyclone database of satellite and airborne observations, in-situ measurements and model simulations containing parameters that pertain to the thermodynamic and microphysical structure of the storms; the air-sea interaction processes; and the large-scale environment.

CloudSat↗

Measurement of Anomalously Strong Emission from the 1s-9p Transition in the Spectrum of H-like Phosphorus Following Charge Exchange with Molecular Hydrogen

We have measured K-shell x-ray spectra of highly ionized argon and phosphorus following charge exchange with molecular hydrogen at low collision energy in an electron beam ion trap using an x-ray calorimeter array with approx.6 eV resolution. We find that the emission at the high-end of the Lyman series is greater by a factor of two for phosphorus than for argon, even though the measurement was performed concurrently and the atomic numbers are similar. This does not agree with current theoretical models and deviates from the trend observed in previous measurements.

Leutenegger, M. A.↗

Observation of Solar Wind Charge Exchange Emission From Exospheric Material in and Outside Earth's Magnetosheath 2008 September 25

A long XMM-Newton exposure is used to observe solar wind charge exchange (SWCX) emission from exospheric material in and outside Earth's magnetosheath. The light curve of the O vii (0.5-0.62 keV) band is compared with a model for the expected emission, and while the emission is faint and the light curve has considerable scatter, the correlation is significant to better than 99.9%. This result demonstrates the validity of the geocoronal SWCX emission model for predicting a contribution to astrophysical observations to a scale factor of order unity (1.5). In addition, an average value of the SWCX O vii emission from the magnetosheath over the observation of 2.6 +/- 0.5 LU is derived. The results also demonstrate the potential utility of using X-ray observations to study global phenomena of the magnetosheath which currently are only investigated using in situ measurements.

Snowden, S. L.↗

What Can Be Learned from X-Ray Spectroscopy Concerning Hot Gas in the Local Bubble and Charge Exchange Processes?

Both solar wind charge exchange emission and diffuse thermal emission from the Local Bubble are strongly dominated in the soft X-ray band by lines from highly ionized elements. While both processes share many of the same lines, the spectra should differ significantly due to the different production mechanisms, abundances, and ionization states. Despite their distinct spectral signatures, current and past observatories have lacked the spectral resolution to adequately distinguish between the two sources. High-resolution X-ray spectroscopy instrumentation proposed for future missions has the potential to answer fundamental questions such as whether there is any hot plasma in the Local Hot Bubble, and if so, what are the abundances of the emitting plasma and whether the plasma is in equilibrium. Such instrumentation will provide dynamic information about the solar wind including data on ion species which are currently difficult to track. It will also make possible remote sensing of the solar wind.

Snowden, S. L.↗