Grover-like search via a Frenkel-exciton trapping mechanism

We propose the physical implementation of a Grover-like search problem by means of Frenkel exciton trapping at a shallow isotopic impurity against a background of competing mechanisms. The search, culminating at the impurity molecule, designated the 'winner' site, is marked by its enhanced interaction with acoustic phonons at low temperatures. The quantum search proceeds with the assistance of an oracle-like exciton-phonon interaction that addresses only the impurity site via the Dyson propagator within the Green's function formalism. The optimum parameters of a graph lattice with long-range intersite interactions required to trap the exciton in the fastest time are determined, and estimates of error rates for the naphthalene-doped organic system are evaluated. We extend the analysis of the quantum search to a fluctuating long-range interacting cycle (LRIC) graph-lattice system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Symmetric Blind Information Reconciliation for Quantum Key Distribution

Quantum key distribution (QKD) is a quantum-proof key-exchange scheme which is fast approaching the communication industry. An essential component in QKD is the information reconciliation step, which is used for correcting the quantum-channel noise errors. The recently suggested blind-reconciliation technique, based on low-density parity-check codes, offers remarkable prospectives for efficient information reconciliation without an a priori quantum bit error rate estimation. We suggest an improvement of the blind-information-reconciliation protocol promoting a significant increase in the efficiency of the procedure and reducing its interactivity. Finally, the proposed technique is based on introducing symmetry in operations of parties, and the consideration of results of unsuccessful belief-propagation decodings.

97 MATHEMATICS AND COMPUTING↗

Resonance states in {sup 27}P using Coulomb dissociation and their effect on the stellar reaction {sup 26}Si(p,{gamma}) {sup 27}P

The stellar reaction {sup 26}Si(p, {gamma}){sup 27}P was studied in the Coulomb dissociation of {sup 27}P. Two known resonance levels in {sup 27}P were excited and a candidate for the third excited state was found in the {sup 26}Si p relative energy spectrum. The E2 resonance strengths {omega}{gamma} were obtained to be (6.5{+-}1.3)x10{sup -11}, (6.0{+-}1.1)x10{sup -10}, and (1.10{+-}0.27)x10{sup -10} MeV. The total (E2+M1) {omega}{gamma} value for the first excited state was evaluated to be 1.9{sub -1.1}{sup +1.9}x10{sup -9} MeV with the help of the shell model. The error was estimated from the deviation of theoretical predictions with the same shell model from experimental strengths obtained in the present study for {sup 27}P and earlier ones for the mirror nucleus {sup 27}Mg. The astrophysical reaction rate for the {sup 26}Si(p, {gamma}){sup 27}P reaction was also calculated and compared with previous estimations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Noncontact gears. I. Next-to-leading order contribution to the lateral Casimir force between corrugated parallel plates

We calculate the lateral Casimir force between corrugated parallel plates, described by {delta}-function potentials, interacting through a scalar field, using the multiple scattering formalism. The contributions to the Casimir energy due to uncorrugated parallel plates is treated as a background from the outset. We derive the leading- and next-to-leading-order contribution to the lateral Casimir force for the case when the corrugation amplitudes are small in comparison to corrugation wavelengths. We present explicit results in terms of finite integrals for the case of the Dirichlet limit, and exact results for the weak-coupling limit, for the leading- and next-to-leading-orders. The correction due to the next-to-leading contribution is significant. In the weak coupling limit we calculate the lateral Casimir force exactly in terms of a single integral which we evaluate numerically. Exact results for the case of the weak limit allows us to estimate the error in the perturbative results. We show that the error in the lateral Casimir force, in the weak coupling limit, when the next-to-leading order contribution is included is remarkably low when the corrugation amplitudes are small in comparison to corrugation wavelengths. We expect similar conclusions to hold for the Dirichlet case. The analogous calculation for the electromagnetic case should reduce the theoretical error sufficiently for comparison with the experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two approaches for the gravitational self-force in black hole spacetime: Comparison of numerical results

Recently, two independent calculations have been presented of finite-mass ('self-force') effects on the orbit of a point mass around a Schwarzschild black hole. While both computations are based on the standard mode-sum method, they differ in several technical aspects, which makes comparison between their results difficult--but also interesting. Barack and Sago [Phys. Rev. D 75, 064021 (2007)] invoke the notion of a self-accelerated motion in a background spacetime, and perform a direct calculation of the local self-force in the Lorenz gauge (using numerical evolution of the perturbation equations in the time domain); Detweiler [Phys. Rev. D 77, 124026 (2008)] describes the motion in terms a geodesic orbit of a (smooth) perturbed spacetime, and calculates the metric perturbation in the Regge-Wheeler gauge (using frequency-domain numerical analysis). Here we establish a formal correspondence between the two analyses, and demonstrate the consistency of their numerical results. Specifically, we compare the value of the conservative O({mu}) shift in u{sup t} (where {mu} is the particle's mass and u{sup t} is the Schwarzschild t component of the particle's four-velocity), suitably mapped between the two orbital descriptions and adjusted for gauge. We find that the two analyses yield the same value for this shift within mere fractional differences of {approx}10{sup -5}-10{sup -7} (depending on the orbital radius)--comparable with the estimated numerical error.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weak lensing effects in the measurement of the dark energy equation of state with LISA

The Laser Interferometer Space Antenna's (LISA's) observation of supermassive binary black holes (SMBBH) could provide a new tool for precision cosmography. Inclusion of subdominant signal harmonics in the inspiral signal allows for high-accuracy sky localization, dramatically improving the chances of finding the host galaxy and obtaining its redshift. A SMBBH merger can potentially have component masses from a wide range (10{sup 5}-10{sup 8}M{sub {center_dot}}) over which parameter accuracies vary considerably. We perform an in-depth study in order to understand (i) what fraction of possible SMBBH mergers allow for sky localization, depending on the parameters of the source, and (ii) how accurately w can be measured when the host galaxy can be identified. We also investigate how accuracies on all parameters improve when a knowledge of the sky position can be folded into the estimation of errors. We find that w can be measured to within a few percent in most cases, if the only error in measuring the luminosity distance is due to LISA's instrumental noise and the confusion background from Galactic binaries. However, weak lensing-induced errors will severely degrade the accuracy with which w can be obtained, emphasizing that methods to mitigate weak lensing effects would be required to take advantage of LISA's full potential.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on primordial non-Gaussianity from galaxy-CMB lensing cross correlation

Recent studies have shown that the primordial non-Gaussianity affects the clustering of dark matter halos through a scale-dependent bias, and various constraints on the non-Gaussianity through this scale-dependent bias have been placed. Here, we introduce the cross correlation between the CMB lensing potential and the galaxy angular distribution to effectively extract information about the bias from the galaxy distribution. Then, we estimate the error of the nonlinear parameter, f{sub NL}, for the ongoing CMB experiments and galaxy surveys, such as Planck and Hyper Suprime-Cam. We found that for the constraint on f{sub NL} with Planck and Hyper Suprime-Cam, the wide field galaxy survey is preferable to the deep one, and the expected error on f{sub NL} can be as small as {Delta}f{sub NL{approx}}80 for b{sub 0}=2 and {Delta}f{sub NL{approx}}30 for b{sub 0}=4, where b{sub 0} is the linear bias parameter. It is also found that a future wide field galaxy survey could achieve {Delta}f{sub NL{approx}}5 with cosmic microwave background prior to Planck, if one could observe highly biased objects at higher redshift (z{approx}2).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Isospin breaking and chiral symmetry restoration

We analyze quark condensates and chiral (scalar) susceptibilities including isospin-breaking effects at finite temperature T. These include m{sub u{ne}}m{sub d} contributions as well as electromagnetic (e{ne}0) corrections, both treated in a consistent chiral Lagrangian framework to leading order in SU(2) and SU(3) chiral perturbation theory, so that our predictions are model-independent. The chiral restoration temperature extracted from <qq>=<uu+dd> is almost unaffected, while the isospin-breaking order parameter <uu-dd> grows with T for the three-flavor case SU(3). We derive a sum rule relating the condensate ratio <qq>(e{ne}0)/<qq>(e=0) with the scalar susceptibility difference {chi}(T)-{chi}(0), directly measurable on the lattice. This sum rule is useful also for estimating condensate errors in staggered lattice analysis. Keeping m{sub u{ne}}m{sub d} allows one to obtain the connected and disconnected contributions to the susceptibility, even in the isospin limit, whose temperature, mass, and isospin-breaking dependence we analyze in detail. The disconnected part grows linearly, diverging in the chiral (infrared) limit as T/M{sub {pi}}, while the connected part shows a quadratic behavior, infrared regular as T{sup 2}/M{sub {eta}}{sup 2}, and coming from {pi}{sup 0{eta}} mixing terms. This smooth connected behavior suggests that isospin-breaking correlations are weaker than critical chiral ones near the transition temperature. We explore some consequences in connection with lattice data and their scaling properties, for which our present analysis for physical masses, i.e. beyond the chiral limit, provides a useful model-independent description for low and moderate temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Role of Collins effect in the single spin asymmetry A{sub N} in p(transv. Polarized) p --> h X processes

The much debated issue of the transverse single spin asymmetry A{sub N} observed in the inclusive large P{sub T} production of a single hadron in pp interactions, p(transv. polarized) p --> {pi} X, is considered in a Transverse Momentum Dependent factorization scheme. A previous result stating that the maximum contribution of the Collins effect is strongly suppressed, is revisited, correcting a numerical error. New estimates are given, adopting the Collins functions recently extracted from Semi-Inclusive Deep Inelastic Scattering and e{sup +}e{sup -} data, and phenomenological consequences are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Testing using Silicon Devices - Analysis of Accuracy: Preprint

Accurately determining PV module performance in the field requires accurate measurements of solar irradiance reaching the PV panel (i.e., Plane-of-Array - POA Irradiance) with known measurement uncertainty. Pyranometers are commonly based on thermopile or silicon photodiode detectors. Silicon detectors, including PV reference cells, are an attractive choice for reasons that include faster timeresponse (10 us) than thermopile detectors (1 s to 5 s), lower cost and maintenance. The main drawback of silicon detectors is their limited spectral response. Therefore, to determine broadband POA solar irradiance, a pyranometer calibration factor that converts the narrowband response to broadband is required. Normally this calibration factor is a single number determined under clear-skyconditions with respect to a broadband reference radiometer. The pyranometer is then used for various scenarios including varying airmass, panel orientation and atmospheric conditions. This would not be an issue if all irradiance wavelengths that form the broadband spectrum responded uniformly to atmospheric constituents. Unfortunately, the scattering and absorption signature varies widely withwavelength and the calibration factor for the silicon photodiode pyranometer is not appropriate for other conditions. This paper reviews the issues that will arise from the use of silicon detectors for PV performance measurement in the field based on measurements from a group of pyranometers mounted on a 1-axis solar tracker. Also we will present a comparison of simultaneous spectral andbroadband measurements from silicon and thermopile detectors and estimated measurement errors when using silicon devices for both array performance and resource assessment.

14 SOLAR ENERGY↗

Timestamp Shift Detection for Synchrophasor Data Based on Similarity Analysis between Relative Phase Angle and Frequency

Timestamp Shift (TS) in synchrophasor data can lead to false operation of synchrophasor-based wide-area monitoring, protection and control applications. The letter presents a method to detect TS of synchrophasor data based on similarity analysis between its own relative phase angle and frequency. Here, a linear correlation component, caused by TS, between relative phase angle and measured frequency is discovered via theoretical derivation. Then a detection method is developed utilizing this linear component for TS diagnosis. Firstly, system phase angle is leveraged as angle reference and then relative phase angle is calculated. Secondly, the correlation coefficient between relative phase angle and frequency is calculated for similarity analysis. Thirdly, the TS is detected via threshold criterion and corresponding time error is estimated. The effectiveness of this method is validated via experiments with actual synchrophasor data in FNET/Grideye.

97 MATHEMATICS AND COMPUTING↗

Road exposure and the detectability of birds in field surveys

Road ecology, the study of the impacts of roads and their traffic on wildlife, including birds, is a rapidly growing field, with research showing effects on local avian population densities up to several kilometres from a road. However, in most studies, the effects of roads on the detectability of birds by surveyors are not accounted for. This could be a significant source of error in estimates of the impacts of roads on birds and could also affect other studies of bird populations. Using road density, traffic volume and bird count data from across Great Britain, we assess the relationships between roads and detectability of a range of bird species. Of 51 species analysed, the detectability of 36 was significantly associated with road exposure, in most cases inversely. Across the range of road exposure recorded for each species, the mean positive change in detectability was 52% and the mean negative change was 36%, with the strongest negative associations found in smaller‐bodied species and those for which aural cues are more important in detection. These associations between road exposure and detectability could be caused by a reduction in surveyors’ abilities to hear birds or by changes in birds’ behaviour, making them harder or easier to detect. We suggest that future studies of the impacts of roads on populations of birds or other taxa, and other studies using survey data from road‐exposed areas, should account for the potential impacts of roads on detectability.

Cooke, Sophia C.↗

Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors

Purpose: As the practice of using high-energy photon beams to create therapeutic radiation fields of subcentimeter dimensions (as in intensity-modulated radiotherapy or stereotactic radiosurgery) grows, so too does the need for accurate verification of beam output at these small fields in which standard practices of dose verification break down. This study investigates small-field output factors measured using a small plastic scintillation detector (PSD), as well as a 0.01 cm{sup 3} ionization chamber. Specifically, output factors were measured with both detectors using small fields that were defined by either the X-Y collimator jaws or the multileaf collimator (MLC). Methods: A PSD of 0.5 mm diameter and 2 mm length was irradiated with 6 and 18 MV linac beams. The PSD was positioned vertically at a source-to-axis distance of 100 cm, at 10 cm depth in a water phantom, and irradiated with fields ranging in size from 0.5x0.5 to 10x10 cm{sup 2}. The field sizes were defined either by the collimator jaws alone or by a MLC alone. The MLC fields were constructed in two ways: with the closed leaves (i.e., those leaves that were not opened to define the square field) meeting at either the field center line or at a 4 cm offset from the center line. Scintillation light was recorded using a CCD camera and an estimation of error in the median-filtered signals was made using the bootstrapping technique. Measurements were made using a CC01 ionization chamber under conditions identical to those used for the PSD. Results: Output factors measured by the PSD showed close agreement with those measured using the ionization chamber for field sizes of 2.0x2.0 cm{sup 2} and above. At smaller field sizes, the PSD obtained output factors as much as 15% higher than those found using the ionization chamber by 0.6x0.6 cm{sup 2} jaw-defined fields. Output factors measured with no offset of the closed MLC leaves were as much as 20% higher than those measured using a 4 cm leaf offset. Conclusions: The authors' results suggest that PSDs provide a useful and possibly superior alternative to existing dosimetry systems for small fields, as they are inherently less susceptible to volume-averaging and perturbation effects than larger, air-filled ionization chambers. Therefore, PSDs may provide more accurate small-field output factor determination, regardless of the collimation mechanism.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analytic variance estimates of Swank and Fano factors

Purpose: Variance estimates for detector energy resolution metrics can be used as stopping criteria in Monte Carlo simulations for the purpose of ensuring a small uncertainty of those metrics and for the design of variance reduction techniques. Methods: The authors derive an estimate for the variance of two energy resolution metrics, the Swank factor and the Fano factor, in terms of statistical moments that can be accumulated without significant computational overhead. The authors examine the accuracy of these two estimators and demonstrate how the estimates of the coefficient of variation of the Swank and Fano factors behave with data from a Monte Carlo simulation of an indirect x-ray imaging detector. Results: The authors' analyses suggest that the accuracy of their variance estimators is appropriate for estimating the actual variances of the Swank and Fano factors for a variety of distributions of detector outputs. Conclusions: The variance estimators derived in this work provide a computationally convenient way to estimate the error or coefficient of variation of the Swank and Fano factors during Monte Carlo simulations of radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-151: Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT

Purpose: To estimate dosimetric errors resulting from using contours deformably mapped from planning CT to 4D cone beam CT (CBCT) images for image-guided adaptive radiotherapy of locally advanced non-small cell lung cancer (NSCLC). Methods: Ten locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan-beam CT (4DFBCT) and weekly 4DCBCT scans. Multiple physicians delineated the gross tumor volume (GTV) and normal structures in planning CT images and only GTV in CBCT images. Manual contours were mapped from planning CT to CBCTs using small deformation, inverse consistent linear elastic (SICLE) algorithm for two scans in each patient. Two physicians reviewed and rated the DIR-mapped (auto) and manual GTV contours as clinically acceptable (CA), clinically acceptable after minor modification (CAMM) and unacceptable (CU). Mapped normal structures were visually inspected and corrected if necessary, and used to override tissue density for dose calculation. CTV (6mm expansion of GTV) and PTV (5mm expansion of CTV) were created. VMAT plans were generated using the DIR-mapped contours to deliver 66 Gy in 33 fractions with 95% and 100% coverage (V66) to PTV and CTV, respectively. Plan evaluation for V66 was based on manual PTV and CTV contours. Results: Mean PTV V66 was 84% (range 75% – 95%) and mean CTV V66 was 97% (range 93% – 100%) for CAMM scored plans (12 plans); and was 90% (range 80% – 95%) and 99% (range 95% – 100%) for CA scored plans (7 plans). The difference in V66 between CAMM and CA was significant for PTV (p = 0.03) and approached significance for CTV (p = 0.07). Conclusion: The quality of DIR-mapped contours directly impacted the plan quality for 4DCBCT-based adaptation. Larger safety margins may be needed when planning with auto contours for IGART with 4DCBCT images. Reseach was supported by NIH P01CA116602.

60 APPLIED LIFE SCIENCES↗

TU-F-9A-01: Balancing Image Quality and Dose in Radiography

Emphasis is often placed on minimizing radiation dose in diagnostic imaging without a complete consideration of the effect on image quality, especially those that affect diagnostic accuracy. This session will include a patient image-based review of diagnostic quantities important to radiologists in conventional radiography, including the effects of body habitus, age, positioning, and the clinical indication of the exam. The relationships between image quality, radiation dose, and radiation risk will be discussed, specifically addressing how these factors are affected by image protocols and acquisition parameters and techniques. This session will also discuss some of the actual and perceived radiation risk associated with diagnostic imaging. Regardless if the probability for radiation-induced cancer is small, the fear associated with radiation persists. Also when a risk has a benefit to an individual or to society, the risk may be justified with respect to the benefit. But how do you convey the risks and the benefits to people? This requires knowledge of how people perceive risk and how to communicate the risk and the benefit to different populations. In this presentation the sources of errors in estimating risk from radiation and some methods used to convey risks are reviewed. Learning Objectives: Understand the image quality metrics that are clinically relevant to radiologists. Understand how acquisition parameters and techniques affect image quality and radiation dose in conventional radiology. Understand the uncertainties in estimates of radiation risk from imaging exams. Learn some methods for effectively communicating radiation risk to the public.

60 APPLIED LIFE SCIENCES↗

WE-E-18A-09: Application of a Channelized Hotelling Observer Model to Evaluate Angiographic Imaging Equipment

Purpose: To develop and apply an observer model to objectively evaluate and compare the performance of different angiographic imaging equipment and acquisition variables. Methods: Image Acquisition— Iodine-based phantoms were created with target diameters: 0.5, 1, 2, and 4 mm. The phantoms were imaged using both planes of a bi-plane angiography system with detector pixel dimensions 0.1542 mm{sup 2} and 0.1842 mm{sup 2}, respectively. All four phantoms were imaged with magnification factors 1.5, 1.25 and 1 and with the large and small focal spots. Phantom position and the dose per frame (0.12– 0.24 μ Gy/frame) were varied for a single phantom size, magnification and focal spot. Observer Model— For each experimental condition, 1200 signal-present and signal-absent images were acquired and a detectability index (d') was calculated with a Gabor-channelized Hotelling observer (CHO) model. Detectability indices were evaluated as a function of dose, phantom size, and magnification. The model was then applied to compare d' of the two imaging planes and focal spots. Uncertainty in d' was estimated by bootstrapping the data and by examining the shift-variance of systems. Results: Detectability indices varied linearly with magnification and the square root of dose. For the 2 and 4 mm phantoms, d' varied linearly with diameter. For the 0.5 and 1 mm phantoms, d' expectedly deviated from this linear relationship due to substantial detector and focal spot blurring of the phantoms. The small focal spot yielded up to 50% greater d' values than the large focal spot. For the two detectors, differences in d' did not exceed the estimated ∼7% error. Conclusions: The detectability indices predictably scaled with dose, diameter, magnification, and focal spot size and serve to validate the model. Results demonstrate statistically similar target detectability for both investigated detectors, despite differences in pixel dimensions. This CHO model provides a framework to evaluate angiographic system performance.

60 APPLIED LIFE SCIENCES↗