Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

The density and thickness of quiescent prominences

The electron density was determined for a number of quiescent prominences at various positions from the Stark effect. It was found that the intensity ratio of Mg I emission lines to SrII lines is independent of the observed electron density in the range of ten to the 10.2 power to 10 to the 11.4 power cm-3. This contrasts with Landman's (1984) theoretical expectation that the ratio is proportional to the electron density. From the intensity of Balmer lines and the electron density, it is inferred that the true diameter of a thread in prominence of high electron density may be smaller than 0.2". The averaged total number density of hydrogen N sub H sub of was found to be 3-6 times 10 to the 11th power cm-3, leading to a total gas pressure P =0.6 dyn cm-2 and a total density of approx. 10 to the minus twelth power g cm-3. Landman's large value of N sub H approx. 6 times 10 to the 12th power and P sub g approx. 6 may have resulted either from the fact that he has treated very bright prominences and/or from the derivation of the high electron density for all prominences he studied.

Hirayama, Tadashi↗

Hemispheric differences in the morphology of the high latitude ionosphere measured at about 500 km

Ambient electron density measurements made by the radio frequency capacitance probe on Ariel 4 have been analyzed in order to study the structures present at about 500 km altitude at latitudes poleward of + or - 50 deg Lambda during the 1971 Northern Hemisphere winter (December solstice) and the 1972 Southern Hemisphere winter (June solstice); data obtained on 94 days centered on each solstice have been used. The general morphology of, and the extreme densities within, the midlatitude electron density trough, the polar cap depletions, and the electron density enhancements associated with the cusp-auroral zone were determined statistically. Analyses of data acquired during quiet magnetic conditions show that the Northern and Southern Hemisphere winter ionospheres were significantly different; in particular, the Southern Hemisphere densities were lower than those in the Northern Hemisphere. The maximum electron densities observed in the Northern Hemisphere occurred in a magnetic-local-time range symmetrical about the 02-14 MLT meridian, whereas in the Southern Hemisphere the maxima were symmetrical with respect to the midnight-noon magnetic meridian.

Tulunay, Y. K.↗

Simultaneous measurement of core electron temperature and density fluctuations during electron cyclotron heating on DIII-D

New measurements show that long-wavelength (k{sub t}hetarho{sub s}<0.5) electron temperature fluctuations can play an important role in determining electron thermal transport in low-confinement mode (L-mode) tokamak plasmas. In neutral beam-heated L-mode tokamak plasmas, electron thermal transport and the amplitude of long-wavelength electron temperature fluctuations both increase in cases where local electron cyclotron heating (ECH) is used to modify the plasma profiles. In contrast, the amplitude of simultaneously measured long-wavelength density fluctuations does not significantly increase. Linear stability analysis indicates that the ratio of the trapped electron mode (TEM) to ion temperature gradient (ITG) mode growth rates increases in the cases with ECH. The increased importance of the TEM drive relative to the ITG mode drive in the cases with ECH may be associated with the increases in electron thermal transport and electron temperature fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative spatiotemporal density evolution of aluminum heated purely by monochromatic electrons

A spatially resolved air-wedge shearing interferometer and shadowgraph diagnostic provides measurements of electron density with a resolution of ∼40 μm. A ∼100-ns-long, monoenergetic electron bunch at 19.8 MeV and a current of 1.4 kA (8.5×1014 e−) heats 100-μm-thick aluminum (Al) foils in a 1-mm-spot to Te∼1 eV. A 5-ns-long, ∼60 mJ, frequency doubled Nd:YAG laser probes the dense Al plasma. Electron densities up to 1020cm−3 are resolved; the maximum resolvable density is limited by opacity, transmission, and spatial fringe density achievable with the detector. This diagnostic provides measurements of the total phase shift, transmission, and electron density. Several measurements at different time slices provide the ability to determine the velocity of the leading edge of the shadowgraph and compare it to the motion of different density shells. These measurements are also compared to radiation hydrodynamics simulations. A rough quantitative agreement is shown between the hydro simulations and the measurements; there are differences in the exact density distributions.

Coleman, J. E. (ORCID:0000000308873757)↗

Design of far-infrared three-wave polarimeter-interferometer system for the J-TEXT tokamak

A multichannel three-wave far-infrared polarimeter-interferometer will be constructed on the J-TEXT tokamak (R=1.05 m, a=0.27 m, B{sub T}{<=}3 T, and I{sub P}{<=}350 kA) for current density profile and electron density profile measurements. The system will adopt the three-wave polarimeter configuration which was first introduced on RTP. Three 432.5 {mu}m HCOOH lasers pumped by three CO{sub 2} lasers separately will be adopted, which could generate high output power, nearly 50 mW at each cavity. Two of them will be counter-rotating circularly polarized to probe the Faraday angle, while the third laser will be used as a local oscillator to get the phase shift caused by electron density. Excellent port access (600x76 mm{sup 2}) and high laser power would promise a profile measurement across the whole plasma section with good signal quality. A high-speed digital phase comparator with a few ({approx}2) {mu}s temporal resolution will be developed, so that fast changes of current or density profile could be measured. Six channels will be installed in the first stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operating a radio-frequency plasma source on water vapor

A magnetically enhanced radio-frequency (rf) plasma source operating on water vapor has an extensive list of potential applications. In this work, the use of a rf plasma source to dissociate water vapor for hydrogen production is investigated. This paper describes a rf plasma source operated on water vapor and characterizes its plasma properties using a Langmuir probe, a residual gas analyzer, and a spectrometer. The plasma source operated first on argon and then on water vapor at operating pressures just over 300 mtorr. Argon and water vapor plasma number densities differ significantly. In the electropositive argon plasma, quasineutrality requires n{sub i}{approx_equal}n{sub e}, where n{sub i} is the positive ion density. But in the electronegative water plasma, quasineutrality requires n{sub i+}=n{sub i-}+n{sub e}. The positive ion density and electron density of the water vapor plasma are approximately one and two orders of magnitude lower, respectively, than those of argon plasma. These results suggest that attachment and dissociative attachment are present in electronegative water vapor plasma. The electron temperature for this water vapor plasma source is between 1.5 and 4 eV. Without an applied axial magnetic field, hydrogen production increases linearly with rf power. With an axial magnetic field, hydrogen production jumps to a maximum value at 500 W and then saturates with rf power. The presence of the applied axial magnetic field is therefore shown to enhance hydrogen production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decision-making in structure solution using Bayesian estimates of map quality: the PHENIX AutoSol wizard

Ten measures of experimental electron-density-map quality are examined and the skewness of electron density is found to be the best indicator of actual map quality. A Bayesian approach to estimating map quality is developed and used in the PHENIX AutoSol wizard to make decisions during automated structure solution. Estimates of the quality of experimental maps are important in many stages of structure determination of macromolecules. Map quality is defined here as the correlation between a map and the corresponding map obtained using phases from the final refined model. Here, ten different measures of experimental map quality were examined using a set of 1359 maps calculated by re-analysis of 246 solved MAD, SAD and MIR data sets. A simple Bayesian approach to estimation of map quality from one or more measures is presented. It was found that a Bayesian estimator based on the skewness of the density values in an electron-density map is the most accurate of the ten individual Bayesian estimators of map quality examined, with a correlation between estimated and actual map quality of 0.90. A combination of the skewness of electron density with the local correlation of r.m.s. density gives a further improvement in estimating map quality, with an overall correlation coefficient of 0.92. The PHENIX AutoSol wizard carries out automated structure solution based on any combination of SAD, MAD, SIR or MIR data sets. The wizard is based on tools from the PHENIX package and uses the Bayesian estimates of map quality described here to choose the highest quality solutions after experimental phasing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Faraday-effect polarimeter-interferometer system for current density measurement on EAST

A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide real-time Faraday rotation angle and density phase shift output, have been developed for use on the POINT system. Initial calibration indicates the electron line-integrated density resolution is less than 5 × 10{sup 16} m{sup −2} (∼2°), and the Faraday rotation angle rms phase noise is <0.1°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equilibrium reconstruction based on core magnetic measurement and its applications on equilibrium transition in Joint-TEXT tokamak

Evaluation and reconstruction of plasma equilibrium, especially to resolve the safety factor profile, is imperative for advanced tokamak operation and physics study. Based on core magnetic measurement by the high resolution laser polarimeter-interferometer system (POLARIS), the equilibrium of Joint-TEXT (J-TEXT) plasma is reconstructed and profiles of safety factor, current density, and electron density are, therefore, obtained with high accuracy and temporal resolution. The equilibrium reconstruction procedure determines the equilibrium flux surfaces essentially from the data of POLARIS. Refraction of laser probe beam, a major error source of the reconstruction, has been considered and corrected, which leads to improvement of accuracy more than 10%. The error of reconstruction has been systematically assessed with consideration of realistic diagnostic performance and scrape-off layer region of plasma, and its accuracy has been verified. Fast equilibrium transitions both within a single sawtooth cycle and during the penetration of resonant magnetic perturbation have been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation characteristics of input power from surface wave sustained plasma antenna

This paper reports radiation characteristics of input power from a surface wave sustained plasma antenna investigated theoretically and experimentally, especially focusing on the power consumption balance between the plasma generation and the radiation. The plasma antenna is a dielectric tube filled with argon and small amount of mercury, and the structure is a basic quarter wavelength monopole antenna at 2.45 GHz. Microwave power at 2.45 GHz is supplied to the plasma antenna. The input power is partially consumed to sustain the plasma, and the remaining part is radiated as a signal. The relationship between the antenna gain and the input power is obtained by an analytical derivation and numerical simulations. As a result, the antenna gain is kept at low values, and most of the input power is consumed to increase the plasma volume until the tube is filled with the plasma whose electron density is higher than the critical electron density required for sustaining the surface wave. On the other hand, the input power is consumed to increase the electron density after the tube is fully filled with the plasma, and the antenna gain increases with increasing the electron density. The dependence of the antenna gain on the electron density is the same as that of a plasma antenna sustained by a DC glow discharge. These results are confirmed by experimental results of the antenna gain and radiation patterns. The antenna gain of the plasma is a few dB smaller than that of the identical metal antenna. The antenna gain of the plasma antenna is sufficient for the wireless communication, although it is difficult to substitute the plasma antenna for metal antennas completely. The plasma antenna is suitable for applications having high affinity with the plasma characteristics such as low interference and dynamic controllability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The 1973 solar occultation of the Crab Nebula pulsar

The mean electron density of the solar corona was determined by measuring the dispersion of radiofrequency pulses from pulsar NP 0532 during the June 1973 solar occultation. Trends continued which were noticed in 1971 as solar activity declined. Model fitting results suggest that the corona continued to become even more concentrated toward the equator in 1973 than in 1971. The number density of electrons in most regions decreased. The best model of the distribution of corona electrons is suggested to be one with zero density at the poles. K-corona isophotes and contours of equal path-integrated density are presented for several models. Electron density versus date and position in the corona are tabulated. It is seen that there is no simple relationship between the onset of major solar activity and density or scattering enhancements.

Weisberg, J. M.↗

The Effect of Background Gas on the Excitation Temperature and Electron Number Density of Basalt Plasma Induced by 10.6 Micron Laser Radiation

Time-integrated optical emission spectroscopy was applied for the analysis of emission spectra, and determination of electron densities and excitation temperatures of basalt plasma induced by 10.6 micron laser radiation. The plasma was studied in air, argon and carbon dioxide, under pressure of 10, 50, and 100 mbar. The plasma emission intensity was found to be strongly dependent on the nature of the ambient gas and its pressure. The highest emission intensities and signal to noise ratios were obtained in argon. Depending on the composition and pressure of the surrounding atmosphere, the values of plasma temperature varied between 14,400 K (air at 10 mbar) and 17,100 K (carbon dioxide at 100 mbar). Similarly, the electron number density varied between 3 × 1016 cm−3 (10 mbar air) and 1.6 × 1017 cm−3 (100 mbar CO2). The observed behavior was correlated with the properties of the studied gases, in particular, their mass, thermal conductivity and ionization energy, and the role of the ambient gas in controlling the efficiency of laser-target coupling, laser-plasma interaction and plasma shielding. © 2019, Springer Science+Business Media, LLC, part of Springer Nature.

60 APPLIED LIFE SCIENCES↗

MODEL-OBSERVATION COMPARISONS OF ELECTRON NUMBER DENSITIES IN THE COMA OF 67P/CHURYUMOV–GERASIMENKO DURING 2015 JANUARY

During 2015 January 9–11, at a heliocentric distance of ∼2.58–2.57 au, the ESA Rosetta spacecraft resided at a cometocentric distance of ∼28 km from the nucleus of comet 67P/Churyumov–Gerasimenko, sweeping the terminator at northern latitudes of 43°N–58°N. Measurements by the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis/Comet Pressure Sensor (ROSINA/COPS) provided neutral number densities. We have computed modeled electron number densities using the neutral number densities as input into a Field Free Chemistry Free model, assuming H{sub 2}O dominance and ion-electron pair formation by photoionization only. A good agreement (typically within 25%) is found between the modeled electron number densities and those observed from measurements by the Mutual Impedance Probe (RPC/MIP) and the Langmuir Probe (RPC/LAP), both being subsystems of the Rosetta Plasma Consortium. This indicates that ions along the nucleus-spacecraft line were strongly coupled to the neutrals, moving radially outward with about the same speed. Such a statement, we propose, can be further tested by observations of H{sub 3}O{sup +}/H{sub 2}O{sup +} number density ratios and associated comparisons with model results.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-space imaging of the electron-pair density hole in molecular Auger–Meitner decay

Electrons in matter can rearrange extremely quickly under external perturbations, underpinning subsequent structural and chemical transformations. Coulomb interactions between neighbouring electrons often shape this response, giving rise to correlated motion and strongly affecting the distribution of electrons in the system. Here we show that non-resonant hard X-ray scattering can directly access changes in the radial electron-pair density during the rapid rearrangement of core and valence electrons. We do this by studying sulfur hexafluoride molecules undergoing Auger–Meitner decay. We exploit a second-order interaction between the X-ray photons and the molecules to trigger and probe the decay dynamics with a single pulse, capturing the electron loss and redistribution before the molecules dissociate. The experiment shows that changes in electron-pair densities can be isolated and measured on ultrafast timescales, providing insight into the real-space evolution of highly excited and short-lived electronic states.

Simmermacher, Mats [University of Oxford (United K↗

Experimental evidence of excited electron number density and temperature effects on electron-phonon coupling in gold films

The electronic transport properties of metals with weak electron-phonon coupling can be influenced by non-thermal electrons. Relaxation processes involving non-thermal electrons competing with the thermalized electron system have led to inconsistencies in the understanding of how electrons scatter and relax with the less energetic lattice. Recent theoretical and computational works have shown that the rate of energy relaxation with the metallic lattice will change depending on the thermalization state of the electrons. Even though 20 years of experimental works have focused on understanding and isolating these electronic relaxation mechanisms with short pulsed irradiation, discrepancies between these existing works have not clearly answered the fundamental question of the competing effects between non-thermal and thermal electrons losing energy to the lattice. In this work, we demonstrate the ability to measure the electron relaxation for varying degrees of both electron-electron and electron-phonon thermalization. This series of measurements of electronic relaxation over a predicted effective electron temperature range up to ∼3500 K and minimum lattice temperatures of 77 K validate recent computational and theoretical works that theorize how a nonequilibrium distribution of electrons transfers energy to the lattice. Utilizing this wide temperature range during pump-probe measurements of electron-phonon relaxation, we explain discrepancies in the past two decades of literature of electronic relaxation rates. We experimentally demonstrate that the electron-phonon coupling factor in gold increases with increasing lattice temperature and laser fluences. Specifically, we show that at low laser fluences corresponding to small electron perturbations, energy relaxation between electrons and phonons is mainly governed by non-thermal electrons, while at higher laser fluences, non-thermal electron scattering with the lattice is less influential on the energy relaxation mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗