Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beam accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Beam loading by electrons in nonlinear plasma wakes

An analytical theory for the interaction of an electron bunch with a nonlinear plasma wave is developed to make it possible to design efficient laser- and/or beam-driven accelerators that generate high quality monoenergetic electron beams. This theory shows how to choose the charge, the shape, and the placing of the bunch so that the conversion efficiency from the fields of the bubble to the accelerating electrons reaches nearly 100% and the beam quality is optimized. For intense drivers the nonlinear wake is described by the shape of the bubble and beam loading arises when the radial space-charge force of the beam acts back on the electron sheath surrounding the ion channel. The modification of the wake due to the presence of flat-top electron bunches is studied and it is shown that the energy spread of an externally injected flat-top electron bunch can be kept low. The bunch profile that leads to zero energy spread is also derived.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasmas, Dielectrics and the Ultrafast: First Science and Operational Experience at FACET

FACET (Facility for Advanced Accelerator and Experimental Tests) is an accelerator R&D test facility that has been recently constructed at SLAC National Accelerator Laboratory. The facility provides 20 GeV, 3 nC electron beams, short (20 {micro}m) bunches and small (20 {micro}m wide) spot sizes, producing uniquely high power beams. FACET supports studies from many fields but in particular those of Plasma Wakefield Acceleration and Dielectric Wakefield Acceleration. FACET is also a source of THz radiation for material studies. We present the FACET design, initial operating experience and first science from the facility.

36 MATERIALS SCIENCE↗

PRECISE CHARGE MEASUREMENT FOR LASER PLASMA ACCELERATORS

Cross-calibrations of charge diagnostics are conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). Employed diagnostics are a scintillating screen, activation based measurement, and integrating current transformer. The diagnostics agreed within {+-}8 %, showing that they can provide accurate charge measurements for LPAs provided they are used properly.

43 PARTICLE ACCELERATORS↗

The Effects of Electron Beam Endpoint Energy on Linear Induction Accelerator Performance

An analysis of beam end-point energy and its effect on accelerator performance is presented. The analysis assumes a 2.0 MeV injector and a linear induction accelerator composed of DARHT Axis-I induction cells operated at nominal voltages. The beam current was scaled to maintain a dose within the range of 3 to 5 MeV photon energy that is consistent with that of the Axis-I nominal dose. The results indicate that beam emittance, space charge effects (including the beam break-up instability), and beam-target interactions are reduced as the end-point energy is increased. Additionally, the spot size growth due to a given average voltage variation across the induction cells is shown to be nearly unchanged for end-point energies above 10 MeV.

43 PARTICLE ACCELERATORS↗

Supra-bubble regime for laser acceleration of coldelectron beams in tenuous plasma

Relativistic electrons can be accelerated by an ultraintense laser pulse in the "supra-bubble" regime, that is, in the blow-out regime ahead of the plasma bubble (as opposed to the conventional method, when particles remain inside the bubble). The acceleration is caused by the ponderomotive force of the pulse, via the so-called snow-plow mechanism. The maximum energy gain, Δγ ~ γg a, is attained when the particle Lorentz factor γ is initially about γg/a, where γg is the pulse group speed Lorentz factor, and a is the laser parameter, proportional to the laser field amplitude. The scheme operates at a ≤ γg, yielding Δγ of up to that via wakefield acceleration for the same plasma and laser parameters, Δγ ~ γ2g. The interaction length is shorter than that for the wake field mechanism but grows with the particle energy, hindering acceleration in multiple stages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Amps particle accelerator definition study

The Particle Accelerator System of the AMPS (Atmospheric, Magnetospheric, and Plasmas in Space) payload is a series of charged particle accelerators to be flown with the Space Transportation System Shuttle on Spacelab missions. In the configuration presented, the total particle accelerator system consists of an energetic electron beam, an energetic ion accelerator, and both low voltage and high voltage plasma acceleration devices. The Orbiter is illustrated with such a particle accelerator system.

Sellen, J. M., Jr.↗

Decimetric type III radio bursts and associated hard X-ray spikes

For a relatively weak solar flare on August 6, 1981, at 10:32 UT, a detailed comparison is made between hard X-ray spikes and decimetric type III radio bursts. The hard X-ray observations are made at energies above 30 keV, and the radio data are obtained in the frequency range from 100 to 1000 MHz. The time resolution for all the data sets is approximately 0.1 s or better. The dynamic radio spectrum exhibits many fast drift type III radio bursts with both normal and reverse slope, whereas the X-ray time profile contains many well resolved short spikes with durations less than or equal to 1 s. Some of the X-ray spikes are seen to be associated in time with reverse-slope bursts, indicating either that the electron beams producing the radio burst contain two or three orders of magnitude more fast electrons than has previously been assumed or that the electron beams can induce the acceleration of additional electrons or occur in coincidence with this acceleration. A case is presented in which a normal slope radio burst at approximately 600 MHz occurs in coincidence with the peak of an X-ray spike to within 0.1 s.

Dennis, B. R.↗

Space experiments with particle accelerators

Electron and plasma beams and neutral gas plumes were injected into the space environment by instruuments on Spacelab 1, and various diagnostic measurements including television camera observations were performed. The results yield information on vehicle charging and neutralization, beam-plasma interactions, and ionization enhancement by neutral beam injection.

Obayashi, T.↗

Research, design and development activities on high power pulsed rf/microwave systems and test facilities for particle accelerators

Several high power S Band microwave systems in the peak power range from 2 MW to 6.5 MW and mean power upto 25 kW along with associated waveguide components, pulse power technology were developed in house at RRCAT. These systems have been used extensively in the development of particle accelerators in the country. Several test facilities were developed in house and supplied to tube R and D labs for development, conditioning and evaluation of microwave tubes indigenously under collaborative efforts. RRCAT has also taken up establishing high power test facilities for advanced accelerators. For such used design and development of 45 MW peak power S Band test facility as well as energy doubler scheme is underway. A 1.3 MW pulsed test stand at 352.2 MHz was also successfully designed and developed to qualify devices, subsystems and components developed in-house. The present paper will describe the research, design and development efforts towards the high power pulsed RF/Microwave systems, test facilities and components. The results and performance of these developments are reported. (author)

43 PARTICLE ACCELERATORS↗

Axis-encircling electron beam generation using a smooth magnetic cusp for gyrodevices

The generation of an annular-shaped axis-encircling electron beam using a smooth magnetic cusp was studied through numerical simulations and experiments for harmonic operation of a gyrodevice. Two magnetic coils were used to form a magnetic cusp located just downstream from the velvet cathode of an accelerator diode. An electron beam of current 34 A and voltage 130 kV with an adjustable velocity ratio {alpha} up to 1.2 was fully transported to the downstream uniform magnetic field region and used to drive a gyrotron traveling wave amplifier into saturation.

43 PARTICLE ACCELERATORS↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Mode growth and competition in the x-ray free-electron laser oscillator start-up from noise.

We describe the radiation properties of an x-ray free-electron laser (FEL) oscillator, beginning with its start-up from noise through saturation. We first decompose the initially chaotic undulator radiation into the growing longitudinal modes of the composite system consisting of the electron beam, the undulator, and the Bragg mirror resonator cavity. Because the radiation initially comprises several modes whose growth rates are comparable, we find that only after many oscillator passes is the output pulse dominantly characterized by the lowest-order Gaussian mode. We verify our analytic results with a novel, reduced one-dimensional FEL code (derived in the text), and with two-dimensional FEL simulations. Understanding the full longitudinal structure during the initial amplification will be critical in assessing the tolerances on the electron beam, undulator, and optical cavity required for robust operation.

43 PARTICLE ACCELERATORS↗