Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electricity demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Advances in Energy Hybridization for Resilient Supply: A Sustainable Approach to the Growing World Demand

Energy poverty, defined as a lack of access to reliable electricity and reliance on traditional biomass resources for cooking, affects over a billion people daily. The World Health Organization estimates that household air pollution from inefficient stoves causes more premature deaths than malaria, tuberculosis, and HIV/AIDS. Increasing demand for energy has led to dramatic increases in emissions. The need for reliable electricity and limiting emissions drives research on Resilient Hybrid Energy Systems (RHESs), which provide cleaner energy through combining wind, solar, and biomass energy with traditional fossil energy, increasing production efficiency and reliability and reducing generating costs and emissions. Microgrids have been shown as an efficient means of implementing RHESs, with some focused mainly on reducing the environmental impact of electric power generation. The technical challenges of designing, implementing, and applying microgrids involve conducting a cradle-to-grave Life Cycle Analysis (LCA) to evaluate these systems’ environmental and economic performance under diverse operating conditions to evaluate resiliency. A sample RHES was developed and used to demonstrate the implementation in rural applications, where the system can provide reliable electricity for heating, cooling, lighting, and pumping clean water. The model and findings can be utilized by other regions around the globe facing similar challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Breakdown of Electric Vehicle Supply Equipment Installation Costs

The plug-in electric vehicles (PEVs) market is receiving help from the current political climate, incentives at the federal and state levels, excessive cost of petroleum fuel, growing focus on climate solutions, increasing investment and direction by automobile manufacturers and increased awareness through media reports and advertising. Increasingly, the transportation industry, in both the United States and many other countries, is aimed at electric motive energy where practical. Increased investment in research and development have led to increasing vehicle range and lower battery costs; both of which have been deterrents in the past. The increasing demand for PEVs (consisting of the battery electric vehicle [BEV] and plug-in hybrid electric vehicle [PHEV], is challenged by the need for charging infrastructure to support these vehicles. The BEV relies totally on the on-board battery to supply the motive energy while the PHEV utilizes its battery and an installed internal combustion engine (ICE). The maximum benefit is achieved by using the battery power as much as possible. This arrangement requires the use of battery charging equipment, known as electric vehicle supply equipment (EVSE).

33 ADVANCED PROPULSION SYSTEMS↗

interflow: A Python package to organize, calculate, and visualize sectoral interdependency flow data

Many economic sectors rely on an uninterrupted “upstream” supply of a resource to conduct their primary functions, leaving them vulnerable to adverse effects should that resource flow be interrupted or compromised (OECD, 2017; U.S. EPA, 2010). Well-known examples of these relationships include water demand by the energy sector (e.g., thermoelectric cooling for nuclear generation) (Grubert & Sanders, 2018; Webber, 2017) and energy demand by the water sector (e.g., electricity required to treat or move water in the public water sector) (Congressional Research Service, 2017) though many others exist. Being able to calculate and document these interdependencies and evaluate where the greatest cross-sectoral intensities and flows exist can reveal opportunities to enhance the overall network. Despite the implications and potential impacts, however, these interconnections and flows have been historically complex to analyze and understand. The interflow package provides a flexible tool to organize, calculate, and visualize (using Sankey diagrams and other visualizations) sectoral interdependency flows for multiple subsectors and resources. This tool can help decision-makers, researchers, and other audiences more easily pull meaning from these interdependencies to reveal multi-faceted opportunities and risks. interflow can help investigate questions such as (1) which sectors have high cross-resource dependencies, (2) how does demand for a resource in various sectors compare across regions, and (3) where the sectoral and regional opportunities are for enhanced efficiency, security, and resiliency.

97 MATHEMATICS AND COMPUTING↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

Technical and Economic Assessment and Gap Analysis of Advanced Nuclear Reactor Integration with a Reference Oil Refinery

Efforts to identify the most-economic methods to decarbonize several sectors of the U.S. economy are underway. Industrial processes such as crude-oil refining rely heavily on energy-dense and easily stored and transported fossil fuels for powering their operations. Refineries use large amounts of energy, primarily derived from fossil sources to separate crude-oil components, break down heavier hydrocarbons into lighter compounds, remove impurities, reform hydrocarbon molecules, and generate steam and electricity for pumps and compressors and other various auxiliary systems. Crude-oil refining operations such as distillation, cracking, desulfurization, reforming, utilities systems and some offsite facilities collectively account for most of the energy consumption. Other operations such as hydrocracking or hydrotreating also require hydrogen for developing hydrogenation reactions which involve substantial heating to keep the reactors at high-temperature and pressure levels. All heat and energy demands are typically provided by natural gas (NG), oil, or other fuels, which makes refinery industry one of the most-difficult sectors to decarbonize. Nuclear power is a viable and energy-dense source of clean electricity, heat, and hydrogen to provide the large, sustainable energy supply that the refining industry demands. The U.S. Department of Energy’s (DOE’s) Integrated Energy Systems (IES) program is working to perform research and development, design, economic siting, and risk analysis. This state-of-the-art work will enable the first on-site demonstrations and commercial deployments of advanced small modular nuclear reactors (SMNRs) integrated with industries such as chemical production, refining, iron and steel making, and more. IES seeks to demonstrate the ability of advanced nuclear reactors to meet the heat and power demands of these industries while reducing carbon emissions in a sustainable and cost-competitive way. The primary objective of this research effort is to analyze industrial-scale SMNR integration intended to decarbonize refining facilities. The foreseen outcome is the provision of reliable, cost-competitive, and sustainable clean energy, alongside a reduction of carbon emissions. Specifically, the focus of this work lies on meeting the reference facilities’ heat and electricity demands with nuclear power while also supplying clean hydrogen via integrated high-temperature steam electrolysis (HTSE). This report presents a comprehensive technical and economic assessment of the integration of advanced nuclear reactors into a reference refinery, leveraging financial incentives from the Inflation Reduction Act (IRA). The evaluation aims to explore the potential economic benefits and challenges associated with incorporating advanced nuclear reactors into refinery operations, particularly in terms of energy efficiency, economic implications and environmental impact. By examining both the technical feasibility and economic viability, this analysis seeks to identify existing gaps and propose solutions for successful nuclear integration implementation. The findings are intended to provide valuable insights for stakeholders considering the adoption of advanced nuclear reactors in the refining sector. A refinery reference-plant was developed, using an open-source refinery model, Petroleum Refinery Lifecycle Inventory Model (PRELIM) and expert assessment, as a base case for comparison with various nuclear integration options. The capacity of 100 kbd/day (KBD) of heavy crude-oil feed was selected to represent a general coking-type refinery with deep conversion capabilities (incorporating heavy-oil upgrading with FCC, coking, and associated hydrotreating process units), using a heavy crude-oil feed, which represents about 70% of U.S. refineries configurations. A summary of all cases considered in this study is shown in Table 1.

13 HYDRO ENERGY↗

Efficient Low-Temperature Direct Lithium Extraction from Chloride Brines Enabled by High-Capacity Sorbent

The demand for lithium, a key component in rechargeable batteries for electric vehicles and renewable energy storage systems, has surged in recent years. Meeting this demand requires efficient extraction methods that are both environmentally friendly and economically viable. This study investigates the utilization of the high-capacity sorbent amorphous aluminum hydroxide for enabling efficient direct lithium extraction at low temperatures. Traditional extraction methods often involve acid-leaching and energy-intensive processes that are not only expensive but also environmentally taxing. In contrast, our approach leverages the exceptional sorption properties of amorphous aluminum hydroxide to facilitate lithium extraction directly from brine, achieving extraction efficiencies of 94.4% in case 1 and 96.2% in case 2 at low temperatures. Kinetic modeling using the Avrami–Erofe’ev framework reveals a nucleation-growth mechanism ( n = 0.71, k = 0.131 h –1 ), providing quantitative insights into the solid-state phase transformation process. This method significantly reduces energy consumption and minimizes the environmental footprint. Through systematic experimentation and optimization, we demonstrate the effectiveness and scalability of our approach, highlighting its potential to revolutionize lithium extraction processes. Our findings highlight the potential of high-capacity sorbents, particularly amorphous aluminum hydroxide toward sustainable lithium production, contributing to the advancement of clean-energy technologies.

anions↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy demand science for a decarbonized society in the context of the residential sector

To develop a decarbonized society, two contradictory requirements must be met: (1) reducing energy demand and (2) creating flexibility in energy demand in order to respond to fluctuations in renewable electricity generation. To help meet these requirements, conventional energy efficiency studies should be extended to incorporate “energy demand science.” This paper presents a definition of “energy demand science” and then reviews the related history and research questions of energy demand science in the context of the residential sector. It then examines three key areas that must be integrated into the next-generation energy demand science: (1) energy demand measurement with detailed granularity and analysis using cutting-edge technology, (2) energy demand modeling that helps clarify the formation mechanism of energy demand, and (3) identification of the factors that influence people's decision making, which represents typical human-dimension research. Energy demand science consists of technical, human, natural environment, demographic, and land-use dimensions, and their integration is key for the establishment of a decarbonized society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microwave Absorbing Perovskite Catalysts for Efficient Electrification of Syngas Production from CO2 and Methane

Microwave absorbing catalysts have the potential to make thermal reactions such as methane reforming (CH4 + CO2 + H2O → H2 + CO) into carbon negative processes when coupled with decarbonized electricity. Due to microwaves directly heating the catalyst rather than heating the reactor and gases, even high temperature reactions such as dry reforming methane (DRM, CH4 + CO2 → H2 + CO) can be achieved rapidly, efficiently, and on-demand, ideal for coupling with intermittent renewable electricity. However, microwave catalysts present unique design challenges due to the same material needing to both efficiently absorb microwaves in oxidative and reductive reaction conditions and be an efficient and stable catalyst in inherently non-isothermal reactors. We screened from over 28 catalysts in the La0.8Sr0.2(Co-Ni-Mn)O3 perovskite solid-solution family to determine promising microwave reforming catalysts and identify design principles for effective materials. The best performing catalyst candidate was able to produce syngas ratios (H2:CO) from 1-3, and scale up testing showed CO and H2 production efficiencies rivaling conventional carbon intensive steam reforming efficiencies at the liters per minute level of production.

Marin, Christopher↗

Optimal Control of SOEC-Based Hydrogen Production Systems for Demand Response Using Deep Reinforcement Learning in Smart Grids

Solid oxide electrolysis cell (SOEC) hydrogen production technology can range in size from small, appliance-size equipment to large-scale, central production facilities that can be tied directly to renewable or non-greenhouse-gas-emitting forms of electricity production, making it an ideal resource for demand response (DR). The SOEC hydrogen production system is a complex integrated system that encompasses fluid dynamics, electrical dynamics, and electrochemical and thermal dynamics, all of which involve non-linearity and non-convexity. Proper control of the SOEC hydrogen production system is crucial to enable its participation in the DR program. Here, to overcome the difficulty of designing an explicit control law for such nonlinear systems with nonconvex optimization features in DR applications, deep reinforcement learning (DRL) is explored to achieve the optimal control of the SOEC system for DR participation. Specifically, a twin delayed deterministic policy gradient (TD3) control framework is applied to achieve optimal response performance during DR events by considering power tracking error and hydrogen production efficiency with a suitable reward function. Two case studies with grid connections for tracking different DR commands were investigated. The first case study involved operating conditions reaching the boundaries, while the second involved operating conditions within the boundaries. The results showed that the proposed DRL-based control for SOEC can track the DR signal in a timely manner while maintaining high energy efficiency.

08 HYDROGEN↗

FREQUENCY REGULATION WITH CONNECTED LIGHTING SYSTEMS

The management of end-use energy resources, e.g., commercial buildings, has been investigated as a promising source of services for the electric power grid. Lighting consumes about 17% electricity of U.S. commercial buildings; however, it may contribute significantly to services that improve the reliability and resilience of the grid due to its rapid speed of response. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change their power demand more quickly than most other building electricity end uses. But the potential of CLS to provide grid services has not been considerably investigated. In this paper, we describe initial research to evaluate the potential of CLS for the grid service of frequency regulation. Frequency regulation is a reliability product that corrects in a matter of seconds for short-term changes in the balance between supply and demand in the balancing area that might affect the stability of the power system. Frequency regulation signals for a medium office building are generated from the normalized test signals for the PJM Interconnection Reg-A and Reg-D regulations services. Control of the CLS locally to follow the Reg-A or Reg-D signal is used to provide contributions to the corresponding frequency regulation service. The performance of CLS for frequency regulation is evaluated using the PJM 40-Minute Performance Score Template. The performance scores obtained for all CLS categories for both Reg-A and Reg-D signals far exceed the minimum score for the qualification, a very promising result for CLS to provide frequency regulation service.

Wang, Peng↗

Development of Next Generation Hierarchical Hybrid Cu-Si anode Batteries via Direct-Ink Writing Application: End of (6th) Month Report - November 2025

Sustainable renewable energy continues to be in dire need to effectively combat global warming. Emerging technology for electric vehicles/ devices remains in high demand that is not only lower in cost, more efficient, but safer in comparison to commercial materials on the market. Although first-generation lithium-ion batteries have exhibited extensive commercial application, conventional graphite no longer meets this increasing demand as an efficient anode material. Due to the fact that graphite has a subpar theoretical specific capacity (372 mAh g -1 ), thus significant limitations in rate capability (for potential faster charging at higher C-rates currently commercially available.). Alternatively, silicon has gained significant attention as a superior candidate to potentially surpass graphite. Due to silicon’s exceedingly high theoretical capacity (4,200 mAh g -1 ) in comparison to standard graphite, its abundance thus in turn it’s low-cost, in addition to exhibiting a significantly low working potential (< 0.4 V vs Li/Li + ). However, one of the main (and most detrimental) challenges is silicon’s tendency to expand in volume (> 300%) upon discharge as it begins the lithiation process. As a direct result, it causes not only for the particles to both crack and pulverize under mechanical stress as the volume continues to expand and contract during cycling. Upon assembling the cell, it needs to undergo ‘charging’ for initially discharging/ ‘activating’ the cell, otherwise commonly known as the ‘formation’ step. As a result a solid electrolyte interface (SEI) layer begins to form at the anode surface because some of the electrolyte begins to react during the formation process. However, this (SEI) layer is deemed as a ‘protective’ interlayer because in theory it prevents further reaction as the cell continues to cycle. However, due to the volume change it causes significant degradation at the interface. As cracking starts to occur at the anode surface, it results in a ‘new’ altered surface with each cycle that causes further reaction with the electrolyte as a byproduct quickly consuming active Li/ and more electrolyte. Thus, fracturing this ‘protective layer,’ causing significantly higher impedance as a result, and in turn a decline in capacity due to active Li-loss. In addition to the active material exfoliating off from the current collector, further contributing to the steady decline in capacity and overall performance. Current state of the art Si-anode batteries on the market range between a maximum content of 5-10 Si wt%. It has been previously reported Tesla has utilized SiO x -C anodes containing 5 wt% Si within their ‘Model 3/ Model X’ electric vehicles. However, more recent ‘Model 3’ vehicles have started to incorporate 10 Si wt%, in which they were able to increase their energy density upwards by approximately 30%. Recent effort has been focused on continuing to increase the wt% of Si being utilized, eventually to 100 wt% of Si, to maximize the energy density even further.

36 MATERIALS SCIENCE↗

Results from "Charging Needs for Electric Semi-Trailer Trucks"

This data set includes modeling results from “Charging Needs for Electric Semi-Trailer Trucks” including charging demand distributions and charging speed requirements for the multiple scenarios and semi-trailer truck operating segments described in the study. Please cite as: Borlaug, B., Moniot, M., Birky, A., Alexander, M., and Muratori, M., Charging needs for electric semi-trailer trucks, Renew. Sust. Energ. Transit. (2022), 2, https://doi.org/10.1016/j.rset.2022.100038.

24 POWER TRANSMISSION AND DISTRIBUTION↗