Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Sub-Doppler Stark Spectroscopy in the A−X (1,0) Band of CN

The effect of external electric fields has been measured in hyperfine-resolved sub-Doppler transitions in the A {sup 2}{Pi}-X {sup 2}{Sigma} (1,0) band of the CN radical near 10900 cm{sup -1}. Static electric fields less than 1 kV/cm are sufficient to mix the most closely spaced {Lambda}-dpublets in the A state, leading to Stark spectra with both new and shifted resonances. Simulations of the saturation-dip Stark spectral line profiles allow extraction of the A-state permanent electric dipole moment with a magnitude of 0.06 {+-} 0.02 D.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photonic Doppler Velocimetry Multiplexing Techniques: Evaluation of Photonic Techniques

This poster reports progress related to photonic technologies. Specifically, the authors developed diagnostic system architecture for a Multiplexed Photonic Doppler Velocimetry (MPDV) that incorporates frequency and time-division multiplexing into existing PDV methodology to provide increased channel count. Current MPDV design increases number of data records per digitizer channel 8x, and also operates as a laser-safe (Class 3a) system. Further, they applied heterodyne interferometry to allow for direction-of-travel determination and enable high-velocity measurements (>10 km/s) via optical downshifting. They also leveraged commercially available, inexpensive and robust components originally developed for telecom applications. Proposed MPDV architectures employ only commercially available, fiber-coupled hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Fisheye Lens as a Photonic Doppler Velocimetry Probe

These presentation visuals report an instrument that, by use of a fish-eye lens, generates a beat signal using fiber mixing of unshifted light with Doppler-shifted light and measures the beat frequency. Ray trace diagrams are shown to illustrate advantages and disadvantages. The authors find their instrument has a long tracking distance, and large angle coverage. Index matching eases assembly, reduces return loss and flattens the field.

47 OTHER INSTRUMENTATION↗

XDV: A proposal for an X-ray Doppler Velocimetry diagnostic

Presentation describes proposal to arrange several bent crystals, each tuned to a different center wavelength within the motional Doppler-broadened profile of a suitable x-ray emission line, to produce a multispectral image that maps wavelength shift to line-of-sight velocity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Stopping Power of Water for Carbon Ions Using Inverted Doppler Shift Attenuation

Carbon ion therapy has gained importance in cancer treatment due to its locally well confined dose distribution, but there is a significant lack of experimental data which is needed for dose calculations and estimation of biological damage. Since tissue is mainly comprised of water, the energy-dependent stopping power of water is the critical measure. Importantly, previous data gathered from experiments with light ions has been limited to water vapour and ice and neglected water in its liquid phase. Additionally, theoretical models regarding the stopping power cannot yet describe the complex charge transfer interactions of the projectile at velocities in the range of the mean velocity of the valence electrons of the traversed medium. There are also discrepancies in the amount of phase effects concerning water and water vapour cross sections. Despite its importance there exists no experimental data for the stopping power of water for carbon ions in the energy region between 1 MeV and 5 MeV. This may be due to the short track length of carbon ions which makes traditional transmission experiments unfeasible. Therefore a project was launched to measure the stopping power of liquid water for carbon ions in the vicinity of the Bragg peak which corresponds to the energy regime of the maximum stopping power. For this measurement the inverted Doppler shift attenuation method was used. This uses the gamma quanta emitted from excited carbon nuclei which are produced by means of the {sup 12}C(α,α'){sup 12}C* reaction. The recorded γ-spectra contain the information of the projectiles velocity at the time they decay to their ground state and an internal clock provided by the exponential decay law. The deceleration of the projectile is directly connected to the stopping power which can be determined with this method as a function of the projectiles kinetic energy. Further measurements have been carried out to improve the experimental method. The setup and the preliminary results of this study will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of KENO Thermal Moderator Doppler Broadening Method in SCALE 6.2 Beta5 Using Continuous-Energy B-VII.1 Library

KENO, the Monte Carlo criticality safety program within the SCALE code package, has until recently used continuous-energy (CE) cross sections corresponding to the set of evaluated nuclear data closest to the temperature of interest. This method, which is used for both 1-D cross sections and thermal scattering probability data, does not fully represent the phenomenon of Doppler broadening (DB) and can result in significant differences in eigenvalues when the material temperature lies between the evaluated data sets. A method for creating temperature-dependent nuclear data has been implemented in KENO for CE calculations. This work summarizes the results of incorporating this method into two critical experiments using low-enriched uranium (LEU) in light water moderated pin lattices. The LEUCOMP-THERM-046 (LCT-046) experiment is a benchmark documented in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook); it consists of 22 critical configurations or cases. The KRITZ-2:1 experiment, a part of the International Reactor Physics Experiment Evaluation Project (IRPhEP), consists of two cases which span a significant range of moderator temperatures. The results of this work give a good indication of the value of the newly incorporated cross section processing. However, more diverse evaluations should be performed to provide a broader validation of this method. The results suggest that when dealing with systems similar to LCT-046, there is a significant improvement made when the moderator scattering data are properly broadened and sampled. The DB of the hydrogen (in water) 2-D cross sections resulted in a consistent C/E value across the temperature range, whereas the DB of the 1-D only cross sections did not exhibit this improvement. With respect to criticality safety, this consistency adds precision to the calculational method, which could potentially impact subcriticality limits. After comparing the KRITZ and LCT-046 results, the most plausible conclusion to make as to why the added thermal moderator treatment improved the results for LCT-046 and not for the KRITZ experiment is that the two systems were dissimilar with respect to their temperatures. That is, the relative temperature differences among the cases in each experiment are more significant for LCT-046 than for KRITZ. The cross section changes as a function of temperature are also smaller at higher temperatures. This difference resulted in a lesser impact of broadening in general for the KRITZ hot case.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rain retrieval from dual-frequency radar Doppler spectra: validation and potential for a midlatitude precipitating case-study

A recently developed technique retrieving the binned raindrop size distributions (DSDs) and air state parameters from ground-based K a and W-band radars Doppler spectra profiles is improved and applied to a typical midlatitude rain event. The retrievals are thoroughly validated against DSD observations of a 2D video disdrometer and independent X-band observations. Here for this case-study, profiles of rain rate, R, mean volume diameter and concentration parameter are retrieved, with low bias and standard deviations. In light rain (0.1 < R < 1 mm h -1 ), the radar reflectivities must be calibrated with a collocated disdrometer which introduces random errors due to sampling mismatch between the two instruments. The best performances are obtained in moderate rain (1 < R < 20 mm h -1 ) where the retrieval is providing self-consistent estimates of the absolute calibration and of the attenuation caused by antenna or radome wetness for both radars.

54 ENVIRONMENTAL SCIENCES↗

Endovascular Treatment of Arterial Complications After Liver Transplantation: Long-Term Follow-Up Evaluated on Doppler Ultrasound and Magnetic Resonance Cholangiopancreatography

Purpose: To evaluate long-term arterial patency and abnormalities of bile ducts in patients that had endovascular treatment for arterial complications after liver transplantation (LT). Materials and Methods: Between 2004 and 2014, 1048 LTs were consecutively performed in our institution and 53 patients (42 men; age range 19–69) were diagnosed and treated by endovascular techniques for arterial complications such as stenosis, thrombosis, dissection or kinking of the hepatic artery (HA). Radiological and surgical data were retrospectively analyzed, and survivors were contacted to undergo follow-up Doppler ultrasound (DUS) of the HA and magnetic resonance cholangiopancreatography. Results: The primary technical success of endovascular treatment was 94% (n = 50). The patency rate of HA at 5-year was 81%. After a median follow-up of 58 months, 17 patients (32%) developed radiological features of ischemic cholangiopathy (IC), including 7 patients with abnormal DUS and 10 with normal DUS. Patients who presented with complications of the HA in the first 3 months after LT developed IC more frequently (42%) than others (12%) (p = 0.028). No other factor was associated with the development of IC. Conclusion: IC was more often observed when HA complication occurred within the first 3 months after LT. The presence of IC was not excluded by a normal DUS during follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wavelength Dependence of Displacement and Velocity Resolution in Laser Doppler Vibrometry

A theoretical approach is used to calculate wavelength dependence of displacement and velocity resolution in the technology of laser Doppler vibrometry (LDV). Mathematical description of a typical LDV system in the heterodyne arrangement is considered in this regard. Thermal noise and shot noise are assumed as the primary source of noise. Minimum target displacement and velocity which produce noise equivalent signal are considered as displacement and velocity resolution respectively. A theoretical linear relationship between laser wavelength and the mentioned resolutions is obtained when all other operational parameters of the LDV system are kept constant. The results of the present research are in good agreement with the earlier experimental researches conducted by others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimation of the mixing layer height over a high altitude site in Central Himalayan region by using Doppler lidar

A Doppler lidar was installed at Manora Peak, Nainital (29.4 N; 79.2 E, 1958 amsl) to estimate mixing layer height for the first time by using vertical velocity variance as basic measurement parameter for the period September-November 2011. Mixing layer height is found to be located ~0.57 +/- 0.1and 0.45 +/- 0.05km AGL during day and nighttime, respectively. The estimation of mixing layer height shows good correlation (R>0.8) between different instruments and with different methods. Our results show that wavelet co-variance transform is a robust method for mixing layer height estimation.

Shukla, K. K.↗

Beam focusing and consequences for Doppler backscattering measurements

The phenomenon of focusing of microwave beams in a plasma near a turning-point caustic is discussed by exploiting the analytical solution to the Gaussian beam-tracing equations in the two-dimensional (2-D) linear-layer problem. The location of maximum beam focusing and the beam width at that location are studied in terms of the beam initial conditions. This focusing must be taken into account to interpret Doppler backscattering (DBS) measurements. We find that the filter function that characterises the scattering intensity contribution along the beam path through the plasma is inversely proportional to the beam width, predicting enhanced scattering from the beam focusing region. We show that the DBS signal enhancement for decreasing incident angles between the beam path and the density gradient is due to beam focusing and not due to forward scattering, as was originally proposed by (Gusakov et al., (Plasma Phys. Contr. Fusion, vol. 56, 2014, p. 0250092014, 2017); Plasma Phys. Rep. vol. 43(6), 2017, pp. 605–613). The analytic beam model is used to predict the measurement of the k y density-fluctuation wavenumber power spectrum via DBS, showing that, in an NSTX-inspired example, the spectral exponent of the turbulent, intermediate-to-high k y density-fluctuation spectrum might be quantitatively measurable via DBS, but not the spectral peak corresponding to the driving scale of the turbulent cascade.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atmospheric Boundary Layer Classification With Doppler Lidar

We present a method using Doppler lidar data for identifying the main sources of turbulent mixing within the atmospheric boundary layer. The method identifies the presence of turbulence and then assigns a turbulent source by combining several lidar quantities: attenuated backscatter coefficient, vertical velocity skewness, dissipation rate of turbulent kinetic energy, and vector wind shear. Both buoyancy-driven and shear-driven situations are identified, and the method operates in both clear-sky and cloud-topped conditions, with some reservations in precipitation. To capture the full seasonal cycle, the classification method was applied to more than 1 year of data from two sites, Hyytiälä, Finland, and Jülich, Germany. Analysis showed seasonal variation in the diurnal cycle at both sites; a clear diurnal cycle was observed in spring, summer, and autumn seasons, but due to their respective latitudes, a weaker cycle in winter at Jülich, and almost non-existent at Hyytiälä. Additionally, there are significant contributions from sources other than convective mixing, with cloud-driven mixing being observed even within the first 500 m above ground. Also evident is the considerable amount of nocturnal mixing within the lowest 500 m at both sites, especially during the winter. The presence of a low-level jet was often detected when sources of nocturnal mixing were diagnosed as wind shear. The classification scheme and the climatology extracted from the classification provide insight into the processes responsible for mixing within the atmospheric boundary layer, how variable in space and time these can be, and how they vary with location.

54 ENVIRONMENTAL SCIENCES↗

Planck 2013 results. XXVII. Doppler boosting of the CMB: Eppur si muove

Our velocity relative to the rest frame of the cosmic microwave background (CMB) generates a dipole temperature anisotropy on the sky which has been well measured for more than 30 years, and has an accepted amplitude of v/c = 1.23 × 10 -3 , or v = 369 s -1 . In addition to this signal generated by Doppler boosting of the CMB monopole, our motion also modulates and aberrates the CMB temperature fluctuations (as well as every other source of radiation at cosmological distances). This is an order 10 -3 effect applied to fluctuations which are already one part in roughly 10 5 , so it is quite small. Nevertheless, it becomes detectable with the all-sky coverage, high angular resolution, and low noise levels of the Planck satellite. Here we report a first measurement of this velocity signature using the aberration and modulation effects on the CMB temperature anisotropies, finding a component in the known dipole direction, ( l,b ) = (264°,48°), of 384 km s -1 ± 78 km s -1 (stat.) ± 115 km s -1 (syst.). This is a significant confirmation of the expected velocity.

79 ASTRONOMY AND ASTROPHYSICS↗

Multichannel Doppler transmission grating spectrometer at the Alcator C-Mod tokamak

Upgrades to an existing transmission grating spectrometer for visible light used for Doppler velocity and temperature measurements at the Alcator C-Mod tokamak are given. These include a new Princeton Instruments Photonmax 512B charge-coupled device and a four channel fiber optic input. These together allow improvements to the signal level, time resolution, and the number of spatial channels. The fiber optic input allows four simultaneous spatial channels each of which offers a larger percentage of input light flux when compared to the standard fiber slit combination. The ''on chip'' amplification combined with versatile pixel binning further increases the signal to noise ratio allowing a continuous acquisition of spectra every 8 ms. The error bars for extracted velocity and temperature values are potentially smaller owing to the smaller pixel size and increased light flux which allow a more detailed line shape and simplifies line fitting. Examples of time and space resolved spectra are shown and further improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photothermal excitation and laser Doppler velocimetry of higher cantilever vibration modes for dynamic atomic force microscopy in liquid

The authors present an optically based method combining photothermal excitation and laser Doppler velocimetry of higher cantilever vibration modes for dynamic atomic force microscopy in liquid. The frequency spectrum of a silicon cantilever measured in water over frequencies ranging up to 10 MHz shows that the method allows us to excite and detect higher modes, from fundamental to fifth flexural, without enhancing spurious resonances. By reducing the tip oscillation amplitude using higher modes, the average tip-sample force gradient due to chemical bonds is effectively increased to achieve high-spatial-resolution imaging in liquid. The method's performance is demonstrated by atomic resolution imaging of a mica surface in water obtained using the second flexural mode with a small tip amplitude of 99 pm; individual atoms on the surface with small height differences of up to 60 pm are clearly resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Doppler-shift attenuation method to the de-excitation {gamma} rays from the in-flight {sup 12}Be beam

The B(E2; {down_arrow}) value of the neutron-rich nucleus {sup 12}Be has been determined through the measurement of the lifetime of the first 2{sup +} state using a modified Doppler-shift attenuation method (DSAM). The first excited state was produced by the inelastic scattering of the intermediate energy {sup 12}Be beam off a thick gold target, which played two roles, to excite the beam and to decrease the velocity. The lifetime has been determined to be 2.5{+-}0.7(stat){+-}0.3(syst) ps, which gives a B(E2) value of 5.0{+-}1.3{+-}0.5 in Weisskopf units. The result shows a large quadrupole strength in the ground state transition. The B(E2) value together with the deformation length measured by proton inelastic scattering yields a neutron quadrupole matrix element two times larger than those for {sup 14}C and {sup 16}O.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IN-PLANE MODAL TESTING OF A FREE ISOTROPIC PLATE USING LASER DOPPLER VIBROMETER MEASUREMENTS

In this work an experimental procedure is proposed to obtain the lowest free in-plane vibration modes of an aluminum plate. Responses are measured along two longitudinal directions on the plate surface at selected points by an out-of-plane laser Doppler vibrometer set up to measure in-plane vibrations. Excitation is made at one specific point of the plate edge using a light impact hammer. The plate is supported by silicone spheres to simulate the free edge boundary conditions and ensure a stable stationary position in order to keep the laser focus distance. Numerical finite element simulations are carried out to compute the in-plane modes and frequencies in order to compare them with the corresponding experimental results. The identified experimental modes agree very well with the numerical predictions. The smooth in-plane modes can be used to identify the plate material constitutive model parameters using existing methods proposed elsewhere by the authors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗