Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Aerosol generation and distribution system for the Third International Cloud Condensation Nuclei Workshop

In order to obtain identical samples participating CCN instruments and aerosol characterizing equipment were located along and connected to a 8.2 cm diameter aluminum tube through which the test aerosols were pumped directly from the source at very slight overpressure. Of the total of 29 experiments, 18 were carried out with artificial NaCl or (NH4)2SO4 aerosols. These were generated from salt solutions by pneumatic atomizers of special design to ensure high constancy of the aerosol output concentration. In three experiments with insoluble CCN (AgI, paraffin wax) the aerosols were generated thermally. In some of the tests, an electrostatic classifier was used for narrowing the particle size distributions.

Katz, U.↗

Mini Guide: Community Engagement Approaches for Distribution System Resilience

The focus on electric grid resilience has gained significant momentum in recent years. The imperatives behind this focus are multifaceted, including the escalating threats of climate change, extreme weather events, and cyber and physical attacks. These challenges expose the vulnerabilities of the country’s aging grid infrastructure and underscore the important

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peer-to-peer Communication Control Architecture for Engaging Ubiquitous DERs to Support Distribution System Resiliency

In this project, we developed a leader-follower consensus (LFC) control architecture to coordinate between GFM and GFL inverters with the former being leaders and the latter being followers. The objective is to simultaneously achieve a fast frequency and voltage regulation along with accurate real power and var sharing among all inverters under various disturbances. The distinction of our work is that we consider both GFM and GFL inveters for frequency and voltage regulations. In addition, rather than a standard consensus algorithm, our work utilized a leader-follower consensus algorithm which exploits the physical characteristics of GFM-GFL inverters: (i) the GFM inverters directly control frequency and voltage, and hence, serve as leaders, (ii) the GFL inverters measure frequency/voltage to modulate their outputs, and hence, they should serve as followers. The effectiveness of the proposed LFC coordination was tested on a networked microgrid test system under different disturbances and communication degradation events. We demonstrated that the proposed fully coordinated control is robust to disturbances, while outperforming uncoordinated and GFM-only coordinated approaches. Overall, this work emphasized the necessity and benefits of the GFMGFL coordination in the secondary control of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System V1G PEV Charging Impacts Report

Plug-in Electric Vehicles (PEVs) are a clean form of transportation that will require a new control paradigm between the energy supply and the transportation sectors as PEV adoption continues to grow. Meeting the projected PEV energy demands will require implementing PEV / grid integration methods beyond charging PEVs at incentivized times. MATLAB was used to simulate the daily vehicle trip demands and charging processes of hundreds of PEVs. The National Household Travel Survey (NHTS) data was used as the source of vehicle travel data, and EV Project provided measured PEV charging data to calibrate the PEV population models. GridLAB-D analyses used a prototypical feeder and PEV population models to evaluate residential PEV V1G (unidirectional) charging in multiple locations, V1G PEV distribution feeder impacts, Time-Of-Use (TOU) rate effects on PEV charging, and charging control methods. The key findings were: optimized charging using California TOU rates could result in savings of over $20 per month for non-TOU program participants; non-TOU participants consume 30-40% of PEV charging energy; about 50% of PEV drivers have their transportation fuel bill reduced by 50 dollars per month; 6.6kW charging will cause distribution transformer power limits to be exceeded on prototypical feeders if the household PEV adoption rate reaches 0.75 PEVs per home; distribution feeder loading is proportional to PEV charging rate; a method was devised to remotely identify when residential transformer overloads occur using changes in PEV charging rate; and the low-cost TOU period is composed of a distribution of PEVs needing small, medium and larger energy needs that can be more effectively shifted as groups to mitigate the TOU peak power and enable a higher PEV adoption rate per household without overloading distribution transformers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurements from an Electrical Distribution System Substation During Hurricane Zeta

Hurricane Zeta made landfall on the United States mainland on October 29, 2020. The hurricane’s impacts on electrical service within the storm path included millions of customers losing power. The eye of the hurricane crossed over Chattanooga, Tennessee, USA, where advanced sensors were monitoring the operational state of a utility substation. A report on the measurement capability and rudimentary results is presented here.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems: Preprint

As the penetration of inverter-based resources (IBRs) continues to increase in modern power systems, system stability is challenged by the insufficient inertia induced by IBRs; hence, there is a need to develop various methods to address the potential instabilities. In this paper, grid-forming (GFM) and grid-following (GFL) controls are implemented for inverters with flexible-mode transitions between them. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small signal stability margin. Further, a holistic and detailed small signal model of the entire system with the dynamics from both synchronous generators (SGs) and IBRs is derived. The effectiveness of the proposed work in adjusting the system small signal stability margin is validated by conducting case studies with varying penetration levels of IBRs. A test system with one SG and five inverters was implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach. Index Terms - grid-following control, grid-forming control, operation mode transition, small-signal stability analysis

grid-following control↗

A VSM-Based DER Dispatch MINLP for Volt-VAR Control in Unbalanced Power Distribution Systems

This paper presents an optimal dispatch algorithm to coordinate customer-owned controllable loads and smart solar inverters with utility-owned voltage regulators and capacitors to meet voltage control objectives. The optimization problem is formulated as a mixed-integer nonlinear programming (MINLP) problem. A voltage sensitivity matrix (VSM) is used to linearize the effect of control actions on the voltage at customer nodes when solving the MINLP. The VSM is recalculated at each time step to improve the computational accuracy. Both discrete switching actions of the capacitor and VRs and the continuous adjustment of real and reactive power from load and smart inverters are considered in the MINLP volt-var problem formulation. The objective function minimizes the cost of all control actions and the magnitude of voltage fluctuations from the previous time period. Constraints ensure that the voltage at each node is maintained within ANSI limits and the feeder power factor is controlled within the desired range. The algorithm is tested using an actual 3-phase unbalanced distribution feeder model. Simulation results demonstrate that the proposed algorithm is computationally feasible on real circuits and improves voltage control while minimizing operational costs.

McEntee, Catie↗

Accurate, Fast and Scalable Kernel Ridge Regression on Parallel and Distributed Systems

Kernel Ridge Regression (KRR) is a fundamental method in machine learning. Given an n-by-d data matrix as input, a traditional implementation requires Θ(n2) memory to form an n-by-n kernel matrix and Θ(n3) flops to compute the final model. These time and storage costs prohibit KRR from scaling up to large datasets. For example, even on a relatively small dataset (a 520k-by-90 input requiring 357 MB), KRR requires 2 TB memory just to store the kernel matrix. Additionally, the reason is that n usually is much larger than d for real-world applications. On the other hand, weak scaling becomes a problem: if we keep d and n/p fixed as p grows (p is # machines), the memory needed grows as Θ(p) per processor and the flops as Θ(p2) per processor. In the perfect weak scaling situation, both the memory needed and the flops grow as Θ(1) per processor (i.e. memory and flops are constant). The traditional Distributed KRR implementation (DKRR) only achieved 0.32% weak scaling efficiency from 96 to 1536 processors. In this work, we propose two new methods to address these problems: the Balanced KRR (BKRR) and K-means KRR (KKRR). These methods consider alternative ways to partition the input dataset into p different parts, generating p different models, and then selecting the best model among them. Compared to a conventional implementation, KKRR2 (optimized version of KKRR) improves the weak scaling efficiency from 0.32% to 38% and achieves a 591x speedup for getting the same accuracy by using the same data and the same hardware (1536 processors). BKRR2 (optimized version of BKRR) achieves a higher accuracy than the current fastest method using less training time for a variety of datasets. For the applications requiring only approximate solutions, BKRR2 improves the weak scaling efficiency to 92% and achieves 3505x speedup (theoretical speedup: 4096x).

97 MATHEMATICS AND COMPUTING↗

A Secure Key Distribution System of Quantum Cryptography Based on the Coherent State

The cryptographic communication has a lot of important applications, particularly in the magnificent prospects of private communication. As one knows, the security of cryptographic channel depends crucially on the secrecy of the key. The Vernam cipher is the only cipher system which has guaranteed security. In that system the key must be as long as the message and most be used only once. Quantum cryptography is a method whereby key secrecy can be guaranteed by a physical law. So it is impossible, even in principle, to eavesdrop on such channels. Quantum cryptography has been developed in recent years. Up to now, many schemes of quantum cryptography have been proposed. Now one of the main problems in this field is how to increase transmission distance. In order to use quantum nature of light, up to now proposed schemes all use very dim light pulses. The average photon number is about 0.1. Because of the loss of the optical fiber, it is difficult for the quantum cryptography based on one photon level or on dim light to realize quantum key-distribution over long distance. A quantum key distribution based on coherent state is introduced in this paper. Here we discuss the feasibility and security of this scheme.

Guo, Guang-Can↗

Advanced Intelligent Sensor Development and Demonstration for Future Distribution Systems with High Penetration DERs

The nation’s electric grid is evolving to supply the electricity needed for economic growth, health, and quality of life. As the DOE has pointed out “Old Tools Won’t Solve New Problems” This project conceived, designed, built, and demonstrated a new tool that promises to make the emerging grid dependable at a lower cost. The tool is a smart sensor with the sensitivity and the bandwidth to measure actionable information about grid health that was unmeasurable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building

With aggressive goals to reduce national energy use and carbon emissions, the U.S. Department of Energy (DOE) will be looking to exemplary buildings that have already invested in new approaches to achieving the energy performance goals now needed at a national level. The New York Times Building, in New York, New York, incorporates a number of innovative technologies, systems and processes and could become model for widespread replication in new and existing buildings. A year-long monitored study was conducted to verify energy performance, assess occupant comfort and satisfaction with the indoor environment, and evaluate impact on maintenance and operations. Lessons learned were derived from the analysis; these lessons could help identify and shape policy, financial, or supporting strategies to accelerate diffusion in the commercial building market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Signal-Based Fast Tripping Protection Schemes for Electric Power Distribution System Resilience

This report is a summary of a 3-year LDRD project that developed novel methods to detect faults in the electric power grid dramatically faster than today’s protection systems. Accurately detecting and quickly removing electrical faults is imperative for power system resilience and national security to minimize impacts to defense critical infrastructure. The new protection schemes will improve grid stability during disturbances and allow additional integration of renewable energy technologies with low inertia and low fault currents. Signal-based fast tripping schemes were developed that use the physics of the grid and do not rely on communication to reduce cyber risks for safely removing faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Noise propagation effects in power supply distribution systems for high-energy physics experiments

High-energy physics experiments are supplied by thousands of power supply units placed in distant areas from the front-end electronics. The power supply units and the front-end electronics are connected through long power cables that propagate the output noise from the power supplies to the detector. Here, this paper addresses the effect of long cables on the noise propagation and the impact that those cables have on the conducted emission levels required for the power supplies and the selection of EMI filters for the front-end electronic low-voltage input. Lastly, this analysis is part of the electromagnetic compatibility based design focused on functional safety to define the type of cable, shield connections, EMI filters and power supply specifications required to ensure the successful integration of the detector and, specifically, to achieve the designed performance of the front-end electronics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RuralAI in Tomato Farming: Integrated Sensor System, Distributed Computing, and Hierarchical Federated Learning for Crop Health Monitoring

Precision horticulture is evolving due to scalable sensor deployment and machine learning (ML) integration. These advancements boost the operational efficiency of individual farms, balancing the benefits of analytics with autonomy requirements. However, given concerns that affect wide geographic regions (e.g., climate change), there is a need to apply models that span farms. Federated learning (FL) has emerged as a potential solution. FL enables decentralized ML across different farms without sharing private data. Traditional FL assumes simple two-tier network topologies and, thus, falls short of operating on more complex networks found in real-world agricultural scenarios. Networks vary across crops and farms and encompass various sensor data modes, extending across jurisdictions. New hierarchical FL (HFL) approaches are needed for more efficient and context-sensitive model sharing, accommodating regulations across multiple jurisdictions. Here, we present the RuralAI architecture deployment for tomato crop monitoring, featuring sensor field units for soil, crop, and weather data collection. HFL with personalization is used to offer localized and adaptive insights. Model management, aggregation, and transfers are facilitated via a flexible approach, enabling seamless communication between local devices, edge nodes, and the cloud.

60 APPLIED LIFE SCIENCES↗

Persistence and decontamination of surrogate radioisotopes in a model drinking water distribution system

Contamination of a model drinking water system with surrogate radioisotopes was examined with respect to persistence on and decontamination of infrastructure surfaces. Cesium and cobalt chloride salts were used as surrogates for cesium-137 and cobalt-60. Studies were conducted in biofilm annular reactors containing heavily corroded iron surfaces formed under shear and constantly submerged in drinking water. Cesium was not detected on the corroded iron surface after equilibration with 10 and 100 mg L{sup -1} solutions of cesium chloride, but cobalt was detected on corroded iron coupons at both initial concentrations. The amount of adhered cobalt decreased over the next six weeks, but was still present when monitoring stopped. X-ray absorption near-edge spectroscopy (XANES) showed that adhered cobalt was in the III oxidation state. The adsorbed cobalt was strongly resistant to decontamination by various physicochemical methods. Simulated flushing, use of free chlorine and dilute ammonia were found to be ineffective whereas use of aggressive methods like 14.5 M ammonia and 0.36 M sulfuric acid removed 37 and 92% of the sorbed cobalt, respectively.

54 ENVIRONMENTAL SCIENCES↗

Mockup Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

air distribution↗

Building America Case Study: Mockup Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Analysis of a Modular Small-Diamter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air handler unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗