Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digital systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Monitoring Digital Closed-Loop Feedback Systems

A technique of monitoring digital closed-loop feedback systems has been conceived. The basic idea is to obtain information on the performances of closed-loop feedback circuits in such systems to aid in the determination of the functionality and integrity of the circuits and of performance margins. The need for this technique arises as follows: Some modern digital systems include feedback circuits that enable other circuits to perform with precision and are tolerant of changes in environment and the device s parameters. For example, in a precision timing circuit, it is desirable to make the circuit insensitive to variability as a result of the manufacture of circuit components and to the effects of temperature, voltage, radiation, and aging. However, such a design can also result in masking the indications of damaged and/or deteriorating components. The present technique incorporates test circuitry and associated engineering-telemetry circuitry into an embedded system to monitor the closed-loop feedback circuits, using spare gates that are often available in field programmable gate arrays (FPGAs). This technique enables a test engineer to determine the amount of performance margin in the system, detect out of family circuit performance, and determine one or more trend(s) in the performance of the system. In one system to which the technique has been applied, an ultra-stable oscillator is used as a reference for internal adjustment of 12 time-to-digital converters (TDCs). The feedback circuit produces a pulse-width-modulated signal that is fed as a control input into an amplifier, which controls the circuit s operating voltage. If the circuit s gates are determined to be operating too slowly or rapidly when their timing is compared with that of the reference signal, then the pulse width increases or decreases, respectively, thereby commanding the amplifier to increase or reduce, respectively, its output level, and "adjust" the speed of the circuits. The nominal frequency of the TDC s pulse width modulated outputs is approximately 40 kHz. In this system, the technique is implemented by means of a monitoring circuit that includes a 20-MHz sampling circuit and a 24-bit accumulator with a gate time of 10 ms. The monitoring circuit measures the duty cycle of each of the 12 TDCs at a repetition rate of 28 Hz. The accumulator content is reset to all zeroes at the beginning of each measurement period and is then incremented or decremented based of the value of the state of the pulse width modulated signal. Positive or negative values in the accumulator correspond to duty cycles greater or less, respectively, than 50 percent.

Katz, Richard↗

A general interactive system for compositing digital radar and satellite data

Reynolds and Smith (1979) have considered the combined use of digital weather radar and satellite data in interactive systems for case study analysis and forecasting. Satellites view the top of clouds, whereas radar is capable of observing the detailed internal structure of clouds. The considered approach requires the use of a common coordinate system. In the present investigation, it was decided to use the satellite coordinate system as the base system in order to maintain the fullest resolution of the satellite data. The investigation is concerned with the development of a general interactive software system called RADPAK for remapping and analyzing conventional and Doppler radar data. RADPAK is implemented as a part of a minicomputer-based image processing system, called Atmospheric and Oceanographic Image Processing System. Attention is given to a general description of the RADPAK system, remapping methodology, and an example of satellite remapping.

Ghosh, K. K.↗

A digital video model deformation system

The use of solid-state array cameras and a PC-controlled image acquisition system to measure model deformation in a wind tunnel is discussed. This digital system improves an earlier video model deformation system that used high-resolution tube cameras and required the manual measurement of targets on video hardcopy images. The new system eliminates both the vibration-induced distortion associated with tube cameras and the manual readup of video images necessary in the earlier version. Camera calibration and data reduction procedures necessary to convert pixel image plane data from two cameras into wing deflections are presented. Laboratory tests to establish the uncertainty of the system with the geometry to be used are described.

Burner, A. W.↗

A Digital Video Model Deformation System

The use of slid-state array cameras and a PC controlled image acquisition system to measure model deformation in a wind tunnel is discussed. This digital system is an improvement to an earlier video model deformation system used at the National Transonic Facility (NTF) which employed high-resolution tube cameras and required the manual measurement of targets on video hardcopy images. The new system eliminates both the vibration-induced distortion associated with tube cameras and the manual readup of video images necessary in the earlier version. Camera calibration and data reduction procedures necessary to convert pixel image plane data from two cameras into wing deflections are presented. Laboratory tests to establish the uncertainty of the new system with the geometry to be used at the NTF are described.

Burner, A. W.↗

Digital controller design: Continuous and discrete describing function analysis of the IPS system

The digital IPS with wire cable and flex pivot nonlinearity is simulated on the digital computer to determine the effects of varying the sampling period T on the system stability, and to determine a range of optimal values of the parameters of the digital controller. The listing of the computer program is shown as well as the Dahl model for the flex pivot nonlinearity. For the wire cable nonlinearity, two ranges of values were used and the nominal values of the digital controller parameters are included.

Source record↗

Digital-flight-control-system software written in automated-engineering-design language: A user's guide of verification and validation tools

The user guide of verification and validation (V&V) tools for the Automated Engineering Design (AED) language is specifically written to update the information found in several documents pertaining to the automated verification of flight software tools. The intent is to provide, in one document, all the information necessary to adequately prepare a run to use the AED V&V tools. No attempt is made to discuss the FORTRAN V&V tools since they were not updated and are not currently active. Additionally, the current descriptions of the AED V&V tools are contained and provides information to augment the NASA TM 84276. The AED V&V tools are accessed from the digital flight control systems verification laboratory (DFCSVL) via a PDP-11/60 digital computer. The AED V&V tool interface handlers on the PDP-11/60 generate a Univac run stream which is transmitted to the Univac via a Remote Job Entry (RJE) link. Job execution takes place on the Univac 1100 and the job output is transmitted back to the DFCSVL and stored as a PDP-11/60 printfile.

Saito, Jim↗

Digital data-acquisition system for measuring the free decay of acoustical standing waves in a resonant tube

A low-cost digital system based on an 8-bit Apple II microcomputer has been designed to provide on-line control, data acquisition, and evaluation of sound absorption measurements in gases. The measurements are conducted in a resonant tube, in which an acoustical standing wave is excited, the excitation removed, and the sound absorption evaluated from the free decay envelope. The free decay is initiated from the computer keyboard after the standing wave is established, and the microphone response signal is the source of the analog signal for the A/D converter. The acquisition software is written in ASSEMBLY language and the evaluation software in BASIC. This paper describes the acoustical measurement, hardware, software, and system performance and presents measurements of sound absorption in air as an example.

Meredith, R. W.↗

Quantitative Risk Analysis of High Safety Significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants using IRADIC Technology

This report documents the activities performed by Idaho National Laboratory (INL) during fiscal year (FY) 2021 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) Risk Assessment project. In FY-2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a strong technical basis to support effective, licensable, and secure DI&C technologies for digital upgrades/designs. An integrated risk assessment technology for the DI&C systems (IRADIC technology) was proposed for this strategy, which aims to (1) provide a best-estimate risk-informed capability to quantitatively and accurately estimate the safety margin obtained from plant modernization, especially for the High Safety Significant Safety-related (HSSSR) DI&C systems, (2) develop an advanced risk assessment technology to support transition from analog to DI&C technologies for nuclear industry, (3) assure the long-term safety and reliability of vital HSSSR DI&C systems, (4) reduce uncertainty in costs and support integration of DI&C systems in the plant. To achieve these technical goals and deal with the expensive licensing justifications from regulatory insights, the IRADIC technology is instructive for nuclear vendors and utilities to effectively lower the costs associated with digital compliance and speed industry advances by: (1) defining an integrated risk-informed analysis process for DI&C upgrade, including hazard analysis, reliability analysis, and consequence analysis, (2) applying systematic and risk-informed tools to address common cause failures (CCFs) and quantify responding failure probabilities for DI&C technologies, particularly software CCFs, (3) evaluating the impact of digital failures at the individual level, system level, and plant level, (4) providing insights and suggestions on designs to manage the risks; thus, to support the development, licensing, and deployment of advanced DI&C technologies on nuclear power plant (NPPs). In this report, an approach for performing software CCF analysis, given limited data, is developed and demonstrated using a case study of a highly redundant digital reactor trip system. Consequence analysis is also performed based on different accident scenarios. Results indicate that plant modernization including the improvement of HSSSR DI&C systems will make great benefits to plant safety by providing more safety margins to accident management. In addition, a novel approach is proposed in this report for the quantification of software hazards when sufficient operational and testing data available. The method incorporates software development quality as well as strong analysis techniques to identify and link software defects to potential failure modes. The approach includes both semantic and test-based analysis to detect failures that can exist in different stages of the software development life cycle. This method is applied to an advanced human system interface relevant to reactor trip safety developed from the APR 1400 design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Signal-to-noise ratio estimation in digital computer simulation of lowpass and bandpass systems with applications to analog and digital communications, volume 3

Techniques are developed to estimate power gain, delay, signal-to-noise ratio, and mean square error in digital computer simulations of lowpass and bandpass systems. The techniques are applied to analog and digital communications. The signal-to-noise ratio estimates are shown to be maximum likelihood estimates in additive white Gaussian noise. The methods are seen to be especially useful for digital communication systems where the mapping from the signal-to-noise ratio to the error probability can be obtained. Simulation results show the techniques developed to be accurate and quite versatile in evaluating the performance of many systems through digital computer simulation.

Tranter, W. H.↗

A flight test evaluation of the pilot interface with a digital advanced avionics system

A flight study was conducted to study pilot workload and the pilot interface with high levels of avionics capability and automation. The study was done in the context of general aviation, single-pilot IFR operations and utilized an experimental, digital, integrated avionics system. Results indicate that such advanced systems can provide improved information to the pilot and increased functional capability. The results also indicate that additional research is needed to increase the knowledge base required to design the pilot interfaces with highly capable systems. A CRT-based moving map display format tested provided excellent navigational situational awareness but was inferior to an HSI for manual path tracking. The complexity of navigation data management, autopilot management, and maintaining awareness of system status contributed to pilot workload and errors. Suggested guidelines for the design of the pilot/avionics interface for advanced avionics systems are given.

Hinton, D. A.↗

Spurious actuations in digital instrumentation and control systems - evaluation framework - 137

When a digital Instrumentation and Control (I and C) system or its associated components produce an unintended operation, it is known as a spurious actuation. Spurious actuations could lead to unnecessary challenges to safety equipment, challenge the ability of safety systems to provide their intended functions, or place the plant in an un-analyzed state. There is arguably a lack of clear and sufficient regulatory guidance for assessing spurious actuations. In an attempt to address this guidance gap, this paper provides a generic framework for evaluating spurious actuations in digital I and C systems, components, or supporting systems that are important to safety. The framework provides a methodology for: (1) defining the scope of the evaluation including supporting assumptions; (2) providing options for excluding a spurious actuation from the evaluation; (3) assessing the potential consequences from the assessed spurious actuations; and, (4) defining a high-level acceptance criteria. The methodology discussed by this paper is not to be construed as a requirement, regulation, or acceptable guidance by either domestic or international regulators; instead, it is intended to serve as a potential foundation or technical basis to be used for developing clear and sufficient regulatory guidance for assessing spurious actuations in digital I and C systems. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation

Purpose: Previously, the authors developed a dual-energy (DE) acquisition technique for a photon-counting digital breast tomosynthesis (DBT) imaging system. Low-energy (LE) and high-energy (HE) images are acquired in a single scan by covering alternate slits of a multislit prepatient collimator with Sn and Cu, respectively. A theoretical model was used to optimize the technique. In this article, an experimental validation of this technique is presented. Methods: Experiments were performed on a prototype DBT system. LE and HE projection images were acquired sequentially; either a Sn or a Cu filter was positioned in the filter holder at the exit window of the x-ray tube. Sn filters from 0.113 to 0.242 mm thick and Cu filters from 0.103 to 0.267 mm were used. The images were acquired with a W target at 49 kV. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. DE-DBT images were obtained by weighted logarithmic subtraction of the LE and HE images. Weighting factors w{sub t} that optimally cancel breast tissues with two different glandularities were assessed for 20-80 mm thick phantoms with 0%, 50%, and 100% glandularity. The mean and standard deviation in the per-pixel signal intensity (SI) were calculated in the DBT images. These data were used to calculate signal-difference-to-noise ratios (SDNRs) between iodine enhanced and nonenhanced polymethyl methacrylate backgrounds. To illustrate the feasibility of the technique, DE-DBT images of a structured phantom containing iodine disks were assessed. The experimental results were compared against the values obtained from a theoretical model of the imaging system. Results: The average difference between theoretical and experimental w{sub t} was found to range from 8% to 21%. Experimental w{sub t} values increase with phantom thickness and Cu thickness, depend somewhat on Sn thickness, and vary more as a function of breast composition in thick breasts than in thin breasts. Theoretical and experimental mean and standard deviation in the per-pixel SI differ by -7% to 10% and by -3% to 4%. Theoretical and experimental SDNR values differ, on average, by 1.5%. Iodine concentrations can be predicted from SDNR; the relationship can be accurately fit to a quadratic. In the images of the structured phantom, iodine concentrations of 1 mg/cm{sup 2} and larger are discernable. Conclusions: The strong agreement between experimental and theoretical results in this article indicates that the authors' computer model is accurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interactive digital image manipulation system

The system is designed for manipulation, analysis, interpretation, and processing of a wide variety of image data. LANDSAT (ERTS) and other data in digital form can be input directly into the system. Photographic prints and transparencies are first converted to digital form with an on-line high-resolution microdensitometer. The system is implemented on a Hewlett-Packard 3000 computer with 128 K bytes of core memory and a 47.5 megabyte disk. It includes a true color display monitor, with processing memories, graphics overlays, and a movable cursor. Image data formats are flexible so that there is no restriction to a given set of remote sensors. Conversion between data types is available to provide a basis for comparison of the various data. Multispectral data is fully supported, and there is no restriction on the number of dimensions. In this way multispectral data collected at more than one point in time may simply be treated as a data collected with twice (three times, etc.) the number of sensors. There are various libraries of functions available to the user: processing functions, display functions, system functions, and earth resources applications functions.

Henze, J.↗

HAZARD ANALYSIS OF DIGITAL ENGINEERED SAFETY FEATURES ACTUATION SYSTEM IN ADVANCED NUCLEAR POWER PLANTS USING A REDUNDANCY-GUIDED APPROACH

Replacing the existing aging analog instrumentation and control (I&C) systems with modern safety control and protection digital technology offers one of the foremost means of performance improvements and cost reductions for the existing nuclear power plants (NPPs). However, the qualification of digital I&C systems remains a challenge, especially considering the issue of software common-cause failures (CCFs), which are difficult to address. With the application and upgrades of advanced digital I&C systems, software CCFs have become a potential threat to plant safety because most redundant designs use similar digital platforms or software in the operating and application systems. With complex designs of multilayer redundancy to meet the single-failure criterion, digital I&C safety systems (e.g., engineered safety-features actuation system [ESFAS]) are of a particular concern in the U.S. Nuclear Regulatory Commission (NRC) licensing procedures. This paper applies a modularized approach to conduct redundancy-guided systems-theoretic hazard analysis for an advanced digital ESFAS with multilevel redundancy designs. Systematic methods and risk-informed tools are incorporated to address both hardware and software CCFs, which provide guidance to eliminate the triggers of potential single points of failure in the design of digital safety systems in advanced plant designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Nuclear Digital I&C System Supply Chain Cyber-Attack Surface

The nuclear supply chain attack surface is a large, complex network of interconnected stakeholders and activities. The global economy has widened and deepened the supply chain, resulting in larger numbers of geographically dispersed locations and increased difficulty ensuring the authenticity and security of digital assets. Although the nuclear industry has made significant strides in securing facilities from cyber-attacks, the supply chain remains vulnerable. This paper outlines supply chain threats and vulnerabilities and provides a Digital I&C System Supply Chain Cyber-Attack Surface diagram to illustrate the complexity of securing hardware, firmware, software, and system information throughout the entire supply chain lifecycle. The knowledge presented in this paper provides a foundation to use in cybersecurity supply chain risk analysis and to guide future supply chain research and development efforts leading to enhancement of a nuclear facility’s overall security posture.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

V/STOLAND avionics system flight-test data on a UH-1H helicopter

The flight-acceptance test results obtained during the acceptance tests of the V/STOLAND (versatile simplex digital avionics system) digital avionics system on a Bell UH-1H helicopter in 1977 at Ames Research Center are presented. The system provides navigation, guidance, control, and display functions for NASA terminal area VTOL research programs and for the Army handling qualities research programs at Ames Research Center. The acceptance test verified system performance and contractual acceptability. The V/STOLAND hardware navigation, guidance, and control laws resident in the digital computers are described. Typical flight-test data are shown and discussed as documentation of the system performance at acceptance from the contractor.

Baker, F. A.↗

Demonstration of the Dynamic Flowgraph Methodology using the Titan 2 Space Launch Vehicle Digital Flight Control System

Dynamic Flowgraph Methodology (DFM) is a new approach developed to integrate the modeling and analysis of the hardware and software components of an embedded system. The objective is to complement the traditional approaches which generally follow the philosophy of separating out the hardware and software portions of the assurance analysis. In this paper, the DFM approach is demonstrated using the Titan 2 Space Launch Vehicle Digital Flight Control System. The hardware and software portions of this embedded system are modeled in an integrated framework. In addition, the time dependent behavior and the switching logic can be captured by this DFM model. In the modeling process, it is found that constructing decision tables for software subroutines is very time consuming. A possible solution is suggested. This approach makes use of a well-known numerical method, the Newton-Raphson method, to solve the equations implemented in the subroutines in reverse. Convergence can be achieved in a few steps.

Yau, M.↗

An Integrated Framework for Risk Assessment of Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants: Methodology Refinement and Exploration

This report documents activities performed by Idaho National Laboratory (INL) during Fiscal Year (FY) 2023 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) risk assessment project. In FY 2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a technical basis to support effective, and secure DI&C technologies for digital upgrades/designs. A risk assessment-informed framework was proposed for this strategy, which aims to (1) provide a best-estimate, risk informed capability to quantitatively estimate the safety margin obtained from plant modernization, especially for safety-related DI&C systems, (2) support and supplement existing risk informed DI&C design guides by providing quantitative risk information and evidence, (3) offer a capability of design architecture evaluation of various DI&C systems, (4) assure the long-term safety and reliability of safety-related DI&C systems, and (5) reduce uncertainty in costs and support integration of DI&C systems in the plant. To achieve these technical goals, the LWRS-developed framework provides a means to address relevant technical issues by: (1) defining a risk informed analysis process for DI&C upgrade that integrates hazard analysis, reliability analysis, and consequence analysis, (2) applying risk informed tools to address common cause failures (CCFs) and quantify corresponding failure probabilities for DI&C technologies, particularly software CCFs, (3) evaluating the impact of digital failures at the component level, system level, and plant level, and (4) providing insights and suggestions on designs to manage the risks, thus to support the development and deployment of advanced DI&C technologies in nuclear power plants (NPPs). Adding diversity within a system or components is the primary means to eliminate and mitigate CCFs, but diversity also increases system complexity and may not address all sources of systematic failures. Optimization of diversity and redundancy applications for the safety-critical DI&C systems remains a challenge. To deal with the technical issues in addressing potential software CCFs in safety-related DI&C systems of NPPs and supporting relevant design optimization, the proposed framework provides: (a) A best-estimate, risk informed capability to address new technical digital issues quantitatively, focusing on software CCFs in safety-related DI&C systems of NPPs; (b) A common and a modularized platform for DI&C designers, software developers, cybersecurity analysts, and plant engineers to predict and prevent risk in the early design stage of DI&C systems; (c) Technical bases and risk informed insights to assist users address the risk informed alternatives for evaluation of CCFs in safety-related DI&C systems of NPPs; and (d) A risk informed tool that offers a capability of design architecture evaluation of various DI&C systems to support system design decisions in diversity and redundancy applications. The research and development efforts of this project in FY 2023 are focused on refining current methods on software CCF modeling and estimation and exploring additional innovative approaches to risk assessment of DI&C systems to enable a more comprehensive and complete assessment of various safety-related DI&C design architectures. The primary audience of this report are DI&C designers, engineers, and probabilistic risk assessment (PRA) practitioners. This includes stakeholders, such as the nuclear utilities and regulators who consider the deployment and upgrade of DI&C systems, DI&C software developers and reviewers, and cybersecurity specialists. It should be noted that all the analyses are performed for the demonstration of the methodology, not for the evaluation of an actual digital control system. Results are obtained based on limited design information and testing data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗