Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Analysis of PNAR Spent Fuel Safeguards Measurements using the ORIGEN Data Analysis Module

This paper summarizes the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements using the ORIGEN data analysis module for 23 boiling water reactor spent fuel assemblies that were performed in Finland under an international collaboration on spent fuel safeguards verification methods. PNAR is part of the proposed integrated nondestructive system to be used for safeguards verifications at the planned Finnish encapsulation facility. Besides measuring passive neutron and gamma emission rates from an assembly like a Fork detector, PNAR also measures the PNAR ratio, which is expected to correlate with the fissile content in the assembly. The emission rates and PNAR ratio can be used to verify the operator declarations and the fissile content of an assembly, respectively. The analysis was performed using the ORIGEN Data Analysis Module, which was originally developed for predicting Fork detector neutron and gamma signals for spent fuel measurements and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the IAEA. The Module includes the ORIGEN burnup analysis code and integrates detector response functions pre-generated using MCNP to predict detector signals in several seconds per assembly. In this study, new response functions specific to PNAR measurements were generated for ORIGEN Module. The study also analyzes impacts of using detailed fuel design and operation information vs. standard safeguards information on results calculated by ORIGEN Module. Using detailed information reduced the standard deviation of relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. This paper describes how ORIGEN Module calculates the expected PNAR neutron and gamma signals and PNAR ratio and how they compare with corresponding measured values.

Ilas, Germina↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single crystal diamond detector measurements of deuterium-deuterium and deuterium-tritium neutrons in Joint European Torus fusion plasmas

First simultaneous measurements of deuterium-deuterium (DD) and deuterium-tritium neutrons from deuterium plasmas using a Single crystal Diamond Detector are presented in this paper. The measurements were performed at JET with a dedicated electronic chain that combined high count rate capabilities and high energy resolution. The deposited energy spectrum from DD neutrons was successfully reproduced by means of Monte Carlo calculations of the detector response function and simulations of neutron emission from the plasma, including background contributions. The reported results are of relevance for the development of compact neutron detectors with spectroscopy capabilities for installation in camera systems of present and future high power fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Graphical Environment Tools for Application to Gamma-Ray Energy Tracking Arrays (Final Report)

Highly segmented, position-sensitive germanium detector systems are being developed for nuclear physics research where traditional electronic signal processing with mixed analog and digital function blocks would be enormously complex and costly. Future systems will be constructed using pipelined processing of high-speed digitized signals as is done in the telecommunications industry. Techniques which provide rapid algorithm and system development for future systems are desirable. This project has used digital signal processing concepts and existing graphical system design tools to develop a set of re-usable modular functions and libraries targeted for the nuclear physics community. Researchers working with complex nuclear detector arrays such as the Gamma-Ray Energy Tracking Array (GRETA) have been able to construct advanced data processing algorithms for implementation in field programmable gate arrays (FPGAs) through application of these library functions using intuitive graphical interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Report from: US Muon Workshop 2021: A Road Map for a Future Muon Facility February 1-2, 2021

The workshop titled “US Muon Workshop 2021: A road map for a future Muon Facility” was held virtually on February 1-2, 2021. The workshop aimed to bring together world experts in muon spectroscopy (µSR) and other techniques along with interested stakeholders to evaluate the scientific need to construct a new µSR facility in the United States (US). The more than 200 participants highlighted several key scientific areas for µSR research, including quantum materials, hydrogen chemistry, and battery materials, and how each area could benefit from a new, high flux pulsed muon source. Experts also discussed aspects of the µSR technique, such as low-energy µSR, novel software developments, and beam and detector technologies that could enable revolutionary advances in µSR at a next-generation facility. The workshop concluded with discussion of a concept being developed for a new µSR facility at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (ORNL). That novel design concept was first envisioned by many of the same µSR experts at a workshop held previously at ORNL in 2016. The participants expressed that the current design had the potential to be a world-leading µSR facility, and strongly encouraged the principal investigators to continue their work in order to refine the concept and determine instrument parameters that would enable new scientific opportunities

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of Portable Programming Models to Accelerate LArTPC Detector Simulations

The Liquid Argon Time Projection Chamber (LArTPC) technology is widely used in high energy physics experiments, including the upcoming Deep Underground Neutrino Experiment (DUNE). Accurately simulating LArTPC detector responses is essential for analysis algorithm development and physics model interpretations. Accurate LArTPC detector response simulations are computationally demanding, and can become a bottleneck in the analysis workflow. Compute devices such as General-Purpose Graphics Processing Units (GPGPUs) have the potential to substantially accelerate simulations compared to traditional CPU-only processing. The software development for these compute accelerators often carries the cost of specialized code refactorization and porting to match the target hardware architecture. With the rapid evolution and increased diversity of the computer architecture landscape, it is highly desirable to have a portable solution that also maintains reasonable performance. We report our ongoing effort in evaluating Kokkos as a basis for this portable programming model using LArTPC simulations in the context of the Wire-Cell Toolkit, a C++ library for LArTPC simulations, data analysis, reconstruction and visualization.

47 OTHER INSTRUMENTATION↗

Energy resolution of the CdTe-XPAD detector:calibration and potential for Laue diffractionmeasurements on protein crystals

The XPAD3S-CdTe, a CdTe photon-counting pixel array detector, has been used to measure the energy and the intensity of the white-beam diffraction from a lysozyme crystal. A method was developed to calibrate the detector in terms of energy, allowing incident photon energy measurement to high resolution (approximately 140 eV), opening up new possibilities in energy-resolved X-ray diffraction. In order to demonstrate this, Laue diffraction experiments were performed on the bending-magnet beamline METROLOGIE at Synchrotron SOLEIL. The X-ray energy spectra of diffracted spots were deduced from the indexed Laue patterns collected with an imaging-plate detector and then measured with both the XPAD3S-CdTe and the XPAD3S-Si, a silicon photon-counting pixel array detector. The predicted and measured energy of selected diffraction spots are in good agreement, demonstrating the reliability of the calibration method. These results open up the way to direct unit-cell parameter determination and the measurement of high-quality Laue data even at low resolution. Based on the success of these measurements, potential applications in X-ray diffraction opened up by this type of technology are discussed.

36 MATERIALS SCIENCE↗

US Muon Workshop 2021: A road map for a future Muon Facility

The workshop title “US Muon Workshop 2021: A road map for a future Muon Facility” was held virtually on February 1-2, 2021. The workshop aimed to bring together world experts in muon spectroscopy (µSR) and other techniques along with interested stakeholders to evaluate the scientific need to construct a new µSR facility in the United States (US). The more than 200 participants highlighted several key scientific areas for µSR research, including quantum materials, hydrogen chemistry, and battery materials, and how each area could benefit from a new, high flux pulsed muon source. Experts also discussed aspects of the µSR technique, such as low-energy µSR, novel software developments, alongside beam and detector technologies, that could enable revolutionary advances in µSR at a next-generation facility. The workshop concluded with discussion of a concept being developed for a new µSR facility at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (ORNL). That novel design concept was first envisioned by many of the same µSR experts at a workshop held previously at ORNL in 2016. The participants expressed that the current design had the potential to be a world-leading µSR facility, and strongly encouraged the principal investigators to continue their work in order to refine the concept and determine instrument parameters that would enable new scientific opportunities.

36 MATERIALS SCIENCE↗

Evaluation of Portable Programming Models to Accelerate LArTPC Detector Simulations

The Liquid Argon Time Projection Chamber (LArTPC) technology is widely used in high energy physics experiments, including the upcoming Deep Underground Neutrino Experiment (DUNE). Accurately simulating LArTPC detector responses is essential for analysis algorithm development and physics model interpretations. Accurate LArTPC detector response simulations are computationally demanding, and can become a bottleneck in the analysis workflow. Compute devices such as General-Purpose Graphics Processing Units (GPGPUs) have the potential to substantially accelerate simulations compared to traditional CPU-only processing. The software development that requires often carries the cost of specialized code refactorization and porting to match the target hardware architecture. With the rapid evolution and increased diversity of the computer architecture landscape, it is highly desirable to have a portable solution that also maintains reasonable performance. We report our ongoing effort in evaluating Kokkos as a basis for this portable programming model using LArTPC simulations in the context of the Wire-Cell Toolkit, a C++ library for LArTPC simulations, data analysis, reconstruction and visualization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differentiable Simulation of a Liquid Argon Time Projection Chamber

Liquid argon time projection chambers (LArTPCs) are widely used in particle detection for their tracking and calorimetric capabilities. The particle physics community actively builds and improves high-quality simulators for such detectors in order to develop physics analyses in a realistic setting. The ability of these simulators to mimic real, measured data is limited by the modeling of the physical detectors used for data collection. This modeling can be improved by performing dedicated calibration measurements. Conventional approaches calibrate individual detector parameters or processes one at a time. However, the impact of detector processes is entangled, making this a poor description of the underlying physics. We introduce a differentiable simulator that enables a gradient-based optimization, allowing for the first time a simultaneous calibration of all detector parameters. We describe the procedure of making a differentiable simulator, highlighting the challenges of retaining the physics quality of the standard, non-differentiable version while providing meaningful gradient information. We further discuss the advantages and drawbacks of using our differentiable simulator for calibration. Finally, we provide a starting point for extensions to our approach, including applications of the differentiable simulator to physics analysis pipelines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

FVTX Technical Report for P-25

A forward silicon vertex detector (the FVTX) was developed to provide the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) with precise charged particle tracking at forward and backward rapidity. The requirements that the detector had to meet included (1) ability to track charged particles to a precision of 25 μm in the azimuthal direction and project those particles to a track vertex with the precision of ~100-200 μm (2) noise levels of ~500 electrons or less (3) very low mass detector configuration so that particles traversing the detector are not scattered by material (4) ability to efficiently reconstruct tracks in an environment where the occupancy of the 1- million channel detector reaches a few % (5) radiation-hard electronics in the interaction region where the detector resides. The FVTX, half of which is shown in Figure 1, is composed of two annular endcaps, each with four stations of silicon mini-­strip sensors, covering forward angles of 10°-­ 35° (with respect to the beam line). Each station consists of 48 individual silicon sensors, which contain two columns of mini-strips with 75μm pitch in the radial direction and lengths in the azimuthal φ direction varying from 3.4 mm at the inner radius to 11.5 mm at the outer radius. The FVTX has approximately 0.54 million strips in each endcap. These are read out with FPHX chips, developed in collaboration with Fermilab, which are wire bonded directly to the mini-strips.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SiD Letter of Intent

This document presents the current status of the Silicon Detector (SiD) effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R and D needed to provide the technical basis for an optimised SiD.

43 PARTICLE ACCELERATORS↗

Kinematic reconstruction of atmospheric neutrino events in a large water Cherenkov detector with proton identification

We report the development of a proton identification method for the Super-Kamiokande (SK) detector. This new tool is applied to the search for events with a single proton track, a high purity neutral current sample of interest for sterile neutrino searches. After selection using a neural network, we observe 38 events in the combined SK-I and SK-II data corresponding to 22 85.1 days of exposure, with an estimated signal-to-background ratio of 1.6 to 1. Proton identification was also applied to a direct search for charged-current quasielastic (CCQE) events, obtaining a high precision sample of fully kinematically reconstructed atmospheric neutrinos, which has not been previously reported in water Cherenkov detectors. The CCQE fraction of this sample is 55%, and its neutrino (as opposed to antineutrino) fraction is 91.7{+-}3%. We selected 78{mu}-like and 47 e-like events in the SK-I and SK-II data set. With this data, a clear zenith angle distortion of the neutrino direction itself is reported in a sub-GeV sample of {mu} neutrinos where the lepton angular correlation to the incoming neutrino is weak. Our fit to {nu}{sub {mu}}{yields}{nu}{sub {tau}} oscillations using the neutrino (L/E) distribution of the CCQE sample alone yields a wide acceptance region compatible with our previous results and excludes the no-oscillation hypothesis at 3-sigma.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

Highly multiplexible thermal kinetic inductance detectors for x-ray imaging spectroscopy

For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present a TKID prototype, which is able to achieve an energy resolution of 75 eV at 5.9 keV, even though its general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing, and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations, we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗