At least 919 records · Page 51

X-Ray Topography of Tetragonal Lysozyme Grown by the Temperature-Controlled Technique

Growth-induced defects in lysozyme crystals were observed by white-beam and monochromatic X-ray topography at the National Synchrotron Light Source (NSLS) at the Brookhaven National Laboratory (BNL). The topographic methods were non-destructive to the extent that traditional diffraction data collection could be performed to high resolution after topography. It was found that changes in growth parameters, defect concentration as detected by X-ray topography, and the diffraction quality obtainable from the crystals were all strongly correlated. In addition, crystals with fewer defects showed lower mosaicity and higher diffraction resolution as expected.

Stojanoff, V.↗

Analysis of historical delta values for IAEA/LANL NDA training courses

The Los Alamos National Laboratory (LANL) supports the International Atomic Energy Agency (IAEA) by providing training for IAEA inspectors in neutron and gamma-ray Nondestructive Assay (NDA) of nuclear material. Since 1980, all new IAEA inspectors attend this two week course at LANL gaining hands-on experience in the application of NDA techniques, procedures and analysis to measure plutonium and uranium nuclear material standards with well known pedigrees. As part of the course the inspectors conduct an inventory verification exercise. This exercise provides inspectors the opportunity to test their abilities in performing verification measurements using the various NDA techniques. For an inspector, the verification of an item is nominally based on whether the measured assay value agrees with the declared value to within three times the historical delta value. The historical delta value represents the average difference between measured and declared values from previous measurements taken on similar material with the same measurement technology. If the measurement falls outside a limit of three times the historical delta value, the declaration is not verified. This paper uses measurement data from five years of IAEA courses to calculate a historical delta for five non-destructive assay methods: Gamma-ray Enrichment, Gamma-ray Plutonium Isotopics, Passive Neutron Coincidence Counting, Active Neutron Coincidence Counting and the Neutron Coincidence Collar. These historical deltas provide information as to the precision and accuracy of these measurement techniques under realistic conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Destructive testings: dry drilling operations with TruPro system to collect samples in a powder form, from two hulls containing immobilized wastes in a hydraulic binder

The TruPro{sup R} process enables to collect a significant number of samples to characterize radiological materials. This innovative and alternative technique is experimented for the ANDRA quality-control inspection of cemented packages. It proves to be quicker and more prolific than the current methodology. Using classical statistics and geo-statistics approaches, the physical and radiological characteristics of two hulls containing immobilized wastes (sludges or concentrates) in a hydraulic binder are assessed in this paper. The waste homogeneity is also evaluated in comparison to ANDRA criterion. Sensibility to sample size (support effect), presence of extreme values, acceptable deviation rate and minimum number of data are discussed. The final objectives are to check the homogeneity of the two characterized radwaste packages and also to validate and reinforce this alternative characterization methodology. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability

Three-dimensional X-ray imaging of living specimens is challenging due to the limited resolution of conventional absorption contrast X-ray imaging and potential irradiation damage of biological specimens. In this letter, we present microtomography of a living specimen combining phase-contrast imaging and a Fourier-based iterative algorithm termed equally sloped tomography. Non-destructive 3D imaging of an anesthetized living yellow mealworm Tenebrio molitor was demonstrated with a relatively low dose using synchrotron generated X-rays. Based on the high-quality 3D images, branching tracheoles and different tissues of the insect in a natural state were identified and analyzed, demonstrating a significant advantage of the technique over conventional X-ray radiography or histotomy. Additionally, the insect survived without problem after a 1.92-s X-ray exposure and subsequent absorbed radiation dose of ∼1.2 Gy. No notable physiological effects were observed after reviving the insect from anesthesia. The improved static tomographic method demonstrated in this letter shows advantage in the non-destructive structural investigation of living insects in three dimensions due to the low radiation dose and high resolution capability, and offers many potential applications in biological science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗

Double diffraction imaging of x-ray induced structural dynamics in single free nanoparticles

Abstract Because of their high photon flux, x-ray free-electron lasers (FEL) allow to resolve the structure of individual nanoparticles via coherent diffractive imaging (CDI) within a single x-ray pulse. Since the inevitable rapid destruction of the sample limits the achievable resolution, a thorough understanding of the spatiotemporal evolution of matter on the nanoscale following the irradiation is crucial. We present a technique to track x-ray induced structural changes in time and space by recording two consecutive diffraction patterns of the same single, free-flying nanoparticle, acquired separately on two large-area detectors opposite to each other, thus examining both the initial and evolved particle structure. We demonstrate the method at the extreme ultraviolet (XUV) and soft x-ray Free-electron LASer in Hamburg (FLASH), investigating xenon clusters as model systems. By splitting a single XUV pulse, two diffraction patterns from the same particle can be obtained. For focus intensities of about 2 × 10 12 W cm −2 we observe still largely intact clusters even at the longest delays of up to 650 picoseconds of the second pulse, indicating that in the highly absorbing systems the damage remains confined to one side of the cluster. Instead, in case of five times higher flux, the diffraction patterns show clear signatures of disintegration, namely increased diameters and density fluctuations in the fragmenting clusters. Future improvements to the accessible range of dynamics and time resolution of the approach are discussed.

Sauppe, M. (ORCID:0000000163123102)↗

Laser holographic nondestructive testing of the NASA X-248 rocket motor

A program to apply holography for nondestructive testing of the X-248 rocket motor was undertaken. The objective was to establish the capability of holography in detecting known unbonding between liner and propellant. Holography was performed employing stressing techniques: (1) acoustical, (2) thermal, (3) radiative, and (4) static loading. Radiative stressing was successful in locating a large area of liner/propellant unbond. The results were correlated with destructive testing. Theoretical analysis provided an understanding of motor case holography in conjunction with radiative stressing.

Harris, W. J.↗

From Tomography to Material Properties of Thermal Protection Systems

A NASA Ames Research Center (ARC) effort, under the Entry Systems Modeling (ESM) project, aims at developing micro-tomography (micro-CT) experiments and simulations for studying materials used in hypersonic entry systems. X-ray micro-tomography allows for non-destructive 3D imaging of a materials micro-structure at the sub-micron scale, providing fiber-scale representations of porous thermal protection systems (TPS) materials. The technique has also allowed for In-situ experiments that can resolve response phenomena under realistic environmental conditions such as high temperature, mechanical loads, and oxidizing atmospheres. Simulation tools have been developed at the NASA Ames Research Center to determine material properties and material response from the high-fidelity tomographic representations of the porous materials with the goal of informing macroscopic TPS response models and guiding future TPS design.

Tomography↗

Interaction of tritium with oils and tritiated waste oil decontamination

Mineral and synthetic oils used as lubricants or operating fluids in pumps are mixtures of branched or cyclic saturated hydrocarbons. They are chemically inert but their slow partial oxidation is possible even at room temperature. Specific activity of pump oils contacted with gaseous tritium for a long time may exceed 10{sup 13} Bq/kg. Studies of waste oils show that more than 90% of the radionuclide is bound with oxidation products. This selectivity is owned to predominant formation of quasifree tritons or {sup 3}HeT{sup +} ions when one of the two nuclei in the T{sub 2} molecule decays. The sequence of ion-molecule triton transport reactions is the mechanism responsible for accumulation of tritium by oxidation products with higher proton affinity. The most effective technique of oil decontamination is adsorption of tritiated species by polar adsorbents (silica gels, zeolites). The detritiation degree for these adsorbents amounts to 95%. Then complete thermal oxidative destruction can be used to convert adsorbed organic compounds into CO{sub 2} and water. Thus, adsorption, thermal oxidation and adsorbent regeneration may be proposed as the technology of tritium recycling since HTO returns to the isotope separation system. As a result, the radiation danger related with storage of high activity waste oils can be significantly decreased. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Applications of Transient Grating Spectroscopy to Radiation Materials Science

Radiation damage is an inherently multi-scale phenomenon, with much of the key material evolution occurring at the mesoscale. Current techniques for the direct interrogation of material property changes due to irradiation either function with very small volumes, such as in-situ TEM, cannot cover the full range of defect populations produced, such as in positron annihilation spectroscopy, or requires destruction of the test material, such as in standard or micromechanical testing. In addition, the ultimate quantities of interest to radiation materials scientists are the changes in key material properties with irradiation. These include stiffness, ductility, and thermal conductivity for structural materials, and optical properties such as index of refraction or changes in transmittance spectra for optically active materials. The latter of these are often correlated directly to stress- or thermally-induced changes, themselves a function of the specific defect populations responsible for their change. The rapid study of such a mesoscale phenomenon requires an inherently mesoscale technique, where multiple quantities of interest can be accurately measured in very short times. Determining the sensitivity of any technique with known certainly is of critical importance to qualifying a new technique to measure in-situ material property changes during irradiation. In this paper, we present the new applicability of an existing technique, known as transient grating (TG) spectroscopy, to rapidly and accurately study key problems in radiation materials science. Results quantifying the absolute sensitivity of the technique are presented, alongside molecular dynamics (MD) simulations of the TG spectroscopy process to gauge direct agreement between theory, simulation, and experiment. An example problem of interest is demonstrated as an illustration of what is possible, showing elastic and thermal changes in irradiated silicon carbide (SiC) films. Finally, future work to quantify the effects of experimentally-simulated radiation defects is proposed, in support of building a database to use TG spectroscopy to deconvolve irradiated material property changes in-situ in terms of the defect populations responsible for their evolution. The application of the TG spectroscopy technique to in-situ radiation materials science has the potential to answer long-standing questions in the field, relating to ion beam rastering, the onset of void swelling, and direct measurement of radiation-created point defect concentrations. Before it can do so, the technique must carefully be analyzed and tuned to increase its sensitivity, the certainty of its results, and the ability to predict radiation-induced changes by simulations must be developed. Making such measurements in-situ with the aid of predictive MD simulations has the potential to elucidate mechanisms of radiation damage accumulation, as well as more rapidly qualify radiation-resistant alloys for service in nuclear systems. Work is underway to build this database of experimentally-simulated radiation-produced defects, which will be combined and compared with actual irradiated materials for eventual in-situ deconvolution of the TG signal into the defect populations responsible for irradiation-induced microstructural change. (authors)

36 MATERIALS SCIENCE↗

Feasibility Study on MR-Guided High-Intensity Focused Ultrasound Ablation of Sciatic Nerve in a Swine Model: Preliminary Results

IntroductionSpastic patients often seek neurolysis, the permanent destruction of the sciatic nerve, for better pain management. MRI-guided high-intensity focused ultrasound (MRgHIFU) may serve as a noninvasive alternative to the prevailing, more intrusive techniques. This in vivo acute study is aimed at performing sciatic nerve neurolysis using a clinical MRgHIFU system.MethodsThe HIFU ablation of sciatic nerves was performed in swine (n = 5) using a HIFU system integrated with a 3 T MRI scanner. Acute lesions were confirmed using T1-weighted contrast-enhanced (CE) MRI and histopathology using hematoxylin and eosin staining. The animals were euthanized immediately following post-ablation imaging.ResultsReddening and mild thickening of the nerve and pallor of the adjacent muscle were seen in all animals. The HIFU-treated sections of the nerves displayed nuclear pyknosis of Schwann cells, vascular hyperemia, perineural edema, hyalinization of the collagenous stroma of the nerve, myelin sheet swelling, and loss of axons. Ablations were visible on CE MRI. Non-perfused volume of the lesions (5.8–64.6 cc) linearly correlated with estimated lethal thermal dose volume (4.7–34.2 cc). Skin burn adjacent to the largest ablated zone was observed in the first animal. Bilateral treatment time ranged from 55 to 138 min, and preparation time required 2 h on average.ConclusionThe acute pilot study in swine demonstrated the feasibility of a noninvasive neurolysis of the sciatic nerve using a clinical MRgHIFU system. Results revealed that acute HIFU nerve lesions were detectable on CE MRI, gross pathology, and histology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure Analysis and Magnetic Evaluation of Tertiary Superheater Tube Used in Gas-Fired Boiler

Failure analysis was carried out on a prematurely failed tertiary superheater tube used in gas-fired boiler. The analysis includes a comparative study of visual examination, chemical composition, hardness and microstructure at failed region, adjacent and far to failure as well as on fresh tube. The chemistry was found matching to the standard specification, whereas the hardness was low in failed tube compared to the fish mouth opening region and the fresh tube. Microscopic examination of failed sample revealed the presence of spheroidal carbides of Cr and Mo predominantly along the grain boundaries. The primary cause of failure is found to be localized heating. Magnetic hysteresis loop (MHL) measurements were carried out to correlate the magnetic parameters with microstructure and mechanical properties to establish a possible non-destructive evaluation (NDE) for health monitoring of the tubes. The coercivity of the MHL showed a very good correlation with microstructure and mechanical properties deterioration enabling a possible NDE technique for the health monitoring of the tubes.

36 MATERIALS SCIENCE↗

In-situ synchrotron X-ray micro-diffraction investigation of ultra-low-strain deformation microstructure in laminated Ti-Al composites

An ultra-low-strain deformation microstructure was revealed for the first time non-destructively in the bulk interior of an annealed laminated Ti-Al composite-in the "fully recrystallized" Al layer-by a synchrotron-based micro-diffraction technique, namely differential aperture X-ray microscopy (DAXM), through real space mapping with a very high angular resolution (0.01 degrees). This ultra-low-strain deformation microstructure was found to result from the thermal stress, induced during cooling after annealing, due to the different coefficients of thermal expansion for the Ti and Al layers. The annealed sample was further tensile deformed to a strain of 1.66% and followed by in situ DAXM and analyzed by various misorientation mapping methods. The results pointed to the important effects of the initial microstructure and the interface constraint, as well as the grain size and crystal orientation, on the plastic deformation. A gradient in dislocation density from the layer interface to the center was found in the Al layer of the annealed sample, and this gradient increased slightly during tensile deformation. The variation of the dislocation density was further discussed based on the activation and interaction of dislocations in grains of different sizes and orientations during plastic deformation. The findings of this study provided valuable insights in understanding the constraint effect of the laminated metal composite and the design of novel composite materials. (c) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Crystallographic orientation↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

Mechanics of finite cracks in dissimilar anisotropic elastic media considering interfacial elasticity

Interfacial crack fields and singularities in bimaterial interfaces (i.e., grain boundaries or dissimilar materials interfaces) are considered through a general formulation for two-dimensional (2-D) anisotropic elasticity while accounting for the interfacial structure by means of an interfacial elasticity paradigm. The interfacial elasticity formulation introduces boundary conditions that are effectively equivalent to those for a weakly bounded interface. This formalism considers the 2-D crack-tip elastic fields using complex variable techniques. While the consideration of the interfacial elasticity does not affect the order of the singularity, it modifies the oscillatory effects associated with problems involving interface cracks. Constructive or destructive “interferences” are directly affected by the interface structure and its elastic response. Furthermore, this general formulation provides an insight on the physical significance and the obvious coupling between the interface structure and the associated mechanical fields in the vicinity of the crack tip.

36 MATERIALS SCIENCE↗

Non-Destructive Characterization of Engineering Materials Using High-Energy X-rays at the Advanced Photon Source

High energy X-rays can penetrate large components and samples made from engineering alloys. Brilliant synchrotron sources like the Advanced Photon Source (APS) combined with unique experimental setups are increasingly allowing scientists and engineers to non-destructively characterize the state of materials across a range of length scales. In this article, some of the new developments at the APS, namely the high energy diffraction microscopy technique for grain-by-grain maps and aperture-based techniques for aggregate maps, are described.

36 MATERIALS SCIENCE↗

Space shuttle nonmetallic materials age life prediction

The chemiluminescence from samples of polybutadiene, Viton, Teflon, Silicone, PL 731 Adhesive, and SP 296 Boron-Epoxy composite was measured at temperatures from 25 to 150 C. Excellent correlations were obtained between chemiluminescence and temperature. These correlations serve to validate accelerated aging tests (at elevated temperatures) designed to predict service life at lower temperatures. In most cases, smooth or linear correlations were obtained between chemiluminescence and physical properties of purified polymer gums, including the tensile strength, viscosity, and loss tangent. The latter is a complex function of certain polymer properties. Data were obtained with far greater ease by the chemiluminescence technique than by the conventional methods of study. The chemiluminescence from the Teflon (Halon) samples was discovered to arise from trace amounts of impurities, which were undetectable by conventional, destructive analysis of the sample.