Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Rapid Cycling CO2 and H2O Removal System for EMU

NASA's planned future missions set stringent demands on the design of the Portable Life Support Systems (PLSS), requiring dramatic reductions in weight, decreased reliance on supplies and greater flexibility on the types of missions. Use of regenerable systems that reduce weight and volume of the EMU is of critical importance to NASA, both for low orbit operations and for long duration manned missions. The CO2 and humidity control unit in the existing PLSS design is relatively large, since it has to remove 8 hours worth of CO2. If the sorbent regeneration can be carried out during the extravehicular activity (EVA) with a relatively high regeneration frequency, the size of the sorbent canister and weight can be significantly reduced. TDA Research, Inc. (TDA) is developing a compact, regenerable sorbent-based system to control CO2 and humidity in the space suit ventilation loop. The sorbent can be regenerated using space vacuum during the EVA, eliminating all duration-limiting elements in the life support system. This paper summarizes the results of the sorbent development and testing, and evaluation efforts. The results of a preliminary system analysis are also included, showing the size and volume reductions provided by the new system.

Alptekin, Gokhan↗

Development of a Rapid Cycling CO(sub 2) and H(sub 2)O Removal Sorbent

The National Aeronautics and Space Administration (NASA) planned future missions set stringent demands on the design of the Portable Life Support System (PLSS), requiring dramatic reductions in weight, decreased reliance on supplies and greater flexibility on the types of missions. Use of regenerable systems that reduce weight and volume of the Extravehicular Mobility Unit (EMU) is of critical importance to NASA, both for low orbit operations and for long duration manned missions. The carbon dioxide and humidity control unit in the existing PLSS design is relatively large, since it has to remove and store 8 hours worth of CO2. If the sorbent regeneration can be carried out during the extravehicular activity (EVA) with a relatively high regeneration frequency, the size of the sorbent canister and weight can be significantly reduced. The progress of regenerable CO2 and humidity control is leading us towards the use of a rapid cycling amine system. TDA Research, Inc. is developing compact, regenerable sorbent materials to control CO2 and humidity in the space suit ventilation loop. The sorbent can be regenerated using space vacuum during the EVA, eliminating all carbon dioxide and humidity duration-limiting elements in the life support system. The material also has applications in other areas of space exploration such as the Orion spacecraft and other longer duration exploration missions requiring regenerable technologies. This paper summarizes the results of the sorbent development, testing, and evaluation efforts to date. The results of a preliminary system analysis are also included, showing the size and volume reductions for PLSS provided by the new system.

Paul, Heather↗

Development of a Rapid Cycling CO2 and H2O Removal Sorbent

The National Aeronautics and Space Administration (NASA) planned future missions set stringent demands on the design of the Portable Life Support System (PLSS), requiring dramatic reductions in weight, decreased reliance on supplies and greater flexibility on the types of missions. Use of regenerable systems that reduce weight and volume of the Extravehicular Mobility Unit (EMU) is of critical importance to NASA, both for low orbit operations and for long duration manned missions. The carbon dioxide and humidity control unit in the existing PLSS design is relatively large, since it has to remove and store eight hours worth of carbon dioxide (CO2). If the sorbent regeneration can be carried out during the Extravehicular Activity (EVA) with a relatively high regeneration frequency, the size of the sorbent canister and weight can be significantly reduced. TDA Research, Inc. is developing compact, regenerable sorbent materials to control CO2 and humidity in the space suit ventilation loop. The sorbent can be regenerated using space vacuum during the EVA, eliminating all CO2 and humidity duration-limiting elements in the life support system. The material also has applications in other areas of space exploration including long duration exploration missions requiring regenerable technologies and possibly the Crew Exploration Vehicle (CEV) spacecraft. This paper summarizes the results of the sorbent development, testing, and evaluation efforts to date.

Alptekin, Gokhan↗

Observing Mode Attitude Controller for the Lunar Reconnaissance Orbiter

The Lunar Reconnaissance Orbiter (LRO) mission is the first of a series of lunar robotic spacecraft scheduled for launch in Fall 2008. LRO will spend at least one year in a low altitude polar orbit around the Moon, collecting lunar environment science and mapping data to enable future human exploration. The LRO employs a 3-axis stabilized attitude control system (ACS) whose primary control mode, the "Observing mode", provides Lunar Nadir, off-Nadir, and Inertial fine pointing for the science data collection and instrument calibration. The controller combines the capability of fine pointing with that of on-demand large angle full-sky attitude reorientation into a single ACS mode, providing simplicity of spacecraft operation as well as maximum flexibility for science data collection. A conventional suite of ACS components is employed in this mode to meet the pointing and control objectives. This paper describes the design and analysis of the primary LRO fine pointing and attitude re-orientation controller function, known as the "Observing mode" of the ACS subsystem. The control design utilizes quaternion feedback, augmented with a unique algorithm that ensures accurate Nadir tracking during large angle yaw maneuvers in the presence of high system momentum and/or maneuver rates. Results of system stability analysis and Monte Carlo simulations demonstrate that the observing mode controller can meet fine pointing and maneuver performance requirements.

Calhourn, Philip C.↗

Observing Mode Attitude Controller for the Lunar Reconnaissance Orbiter

The Lunar Reconnaissance Orbiter (LRO) mission is the first of a series of lunar robotic spacecraft scheduled for launch in Fall 2008. LRO will spend at least one year in a low altitude polar orbit around the Moon, collecting lunar environment science and mapping data to enable future human exploration. The LRO employs a 3-axis stabilized attitude control system (ACS) whose primary control mode, the "Observing mode", provides Lunar Nadir, off-Nadir, and Inertial fine pointing for the science data collection and instrument calibration. The controller combines the capability of fine pointing with that of on-demand large angle full-sky attitude reorientation into a single ACS mode, providing simplicity of spacecraft operation as well as maximum flexibility for science data collection. A conventional suite of ACS components is employed in this mode to meet the pointing and control objectives. This paper describes the design and analysis of the primary LRO fine pointing and attitude re-orientation controller function, known as the "Observing mode" of the ACS subsystem. The control design utilizes quaternion feedback, augmented with a unique algorithm that ensures accurate Nadir tracking during large angle yaw maneuvers in the presence of high system momentum and/or maneuver rates. Results of system stability analysis and Monte Carlo simulations demonstrate that the observing mode controller can meet fine pointing and maneuver performance requirements.

Calhoun, Philip C.↗

Wide-area Demand-side Control for Inter-area Oscillation Mitigation in Power Systems

Inter-area oscillations have severely limited maximum power transfer among different areas in large-scale interconnected power grid. If not quickly damped as soon as possible, they may cause system breakup and even lead to large cascading blackouts. To increase the damping of inter-area oscillations, both power system stabilizer~(PSS) and flexible AC transmission system~(FACTS) controller have been widely considered, which affect the real power flow indirectly. However, the effectiveness of these controllers is restricted to the neighborhood of a prescribed set of operating conditions. In this paper, wide-area demand-side control is developed to directly modulate the real power of end-user loads for oscillation mitigation. The proposed control strategy is implemented in a hierarchical manner. At the device layer, individual end-user loads independently turn ON or OFF in response to the broadcasted signals from the coordinator during the real time. At the supervisory layer, autonomous responses of end-user loads are coordinated to ensure the desired power modulation. The effectiveness of the proposed wide-area demand-side control in improving small-signal stability is illustrated by simulations on a large-scale test system.

Lian, Jianming↗

Aggregated Residential Load Modeling Using Dynamic Bayesian Networks

Abstract—It is already obvious that the future power grid will have to address higher demand for power and energy, and to incorporate renewable resources of different energy generation patterns. Demand response (DR) schemes could successfully be used to manage and balance power supply and demand under operating conditions of the future power grid. To achieve that, more advanced tools for DR management of operations and planning are necessary that can estimate the available capacity from DR resources. In this research, a Dynamic Bayesian Network (DBN) is derived, trained, and tested that can model aggregated load of Heating, Ventilation, and Air Conditioning (HVAC) systems. DBNs can provide flexible and powerful tools for both operations and planing, due to their unique analytical capabilities. The DBN model accuracy and flexibility of use is demonstrated by testing the model under different operational scenarios.

Bayesian↗

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

An offline unstructured biogeochemical model (UBM) for complex estuarine and coastal environments

Due to increased pollutant loads and water use from coastal development and population growth, occurrences of low-dissolved oxygen and "hypoxic zones" have increased. Reports of fish kills and water quality impairment are also becoming more frequent in many coastal waters. Water quality managers and regulatory agencies rely on numerical modeling tools to quantify the relative contributions of anthropogenic and "natural" pollutant loads (nutrients and biochemical oxygen demand) on dissolved oxygen levels and use the results for remedial activities and source control. The ability to conduct seasonlong simulations with sufficient nearshore resolution is therefore a key requirement. Mesh flexibility and the ability to increase site specific resolution without disturbing the larger domain setup and calibration are critical. The objective of this effort was to develop a robust biogeochemical model suitable for simulation of water quality dynamics including dissolved oxygen in complex coastal environments with multiple tidal channels, tidal flats, and density-driven circulation using unstructured-grid formulation. This paper presents an offline unstructured biogeochemical model that uses the Finite Volume Coastal Ocean Model (FVCOM) discretization of the study domain and the corresponding hydrodynamic solution to drive biogeochemical kinetics based on a water quality model CE-QUAL-ICM. In this paper, the linkage between selected hydrodynamic and water quality models is subjected to several scalar transport and biogeochemical module tests (plume transport and dilution, BOD/DO sag, and phytoplankton/nutrients reaction), and results are compared to their analytical solutions as part of model validation. A preliminary application of the biogeochemical model with a year-long simulation of Hood Canal basin in Puget Sound, USA, is presented as an example and a test of the tool in a real estuary setting. The model reproduced the dynamics and seasonal variations in the biogeochemical state variables and was used to test short-term wind-driven dynamics that could influence dissolved oxygen concentrations in Hood Canal.

54 ENVIRONMENTAL SCIENCES↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

GNET2: an R package for constructing gene regulatory networks from transcriptomic data

Abstract Motivation The Gene Network Estimation Tool (GNET) is designed to build gene regulatory networks (GRNs) from transcriptomic gene expression data with a probabilistic graphical model. The data preprocessing, model construction and visualization modules of the original GNET software were developed on different programming platforms, which were inconvenient for users to deploy and use. Results Here, we present GNET2, an improved implementation of GNET as an integrated R package. GNET2 provides more flexibility for parameter initialization and regulatory module construction based on the core iterative modeling process of the original algorithm. The data exchange interface of GNET2 is handled within an R session automatically. Given the growing demand for regulatory network reconstruction from transcriptomic data, GNET2 offers a convenient option for GRN inference on large datasets. Availability and implementation The source code of GNET2 is available at https://github.com/jianlin-cheng/GNET2. Supplementary information Supplementary data are available at Bioinformatics online.

59 BASIC BIOLOGICAL SCIENCES↗

Identifying Functional Requirements for Flexible Airspace Management Concept Using Human-In-The-Loop Simulations

Flexible Airspace Management (FAM) is a mid- term Next Generation Air Transportation System (NextGen) concept that allows dynamic changes to airspace configurations to meet the changes in the traffic demand. A series of human-in-the-loop (HITL) studies have identified procedures and decision support requirements needed to implement FAM. This paper outlines a suggested FAM procedure and associated decision support functionality based on these HITL studies. A description of both the tools used to support the HITLs and the planned NextGen technologies available in the mid-term are presented and compared. The mid-term implementation of several NextGen capabilities, specifically, upgrades to the Traffic Management Unit (TMU), the initial release of an en route automation system, the deployment of a digital data communication system, a more flexible voice communications network, and the introduction of a tool envisioned to manage and coordinate networked ground systems can support the implementation of the FAM concept. Because of the variability in the overall deployment schedule of the mid-term NextGen capabilities, the dependency of the individual NextGen capabilities are examined to determine their impact on a mid-term implementation of FAM. A cursory review of the different technologies suggests that new functionality slated for the new en route automation system is a critical enabling technology for FAM, as well as the functionality to manage and coordinate networked ground systems. Upgrades to the TMU are less critical but important nonetheless for FAM to be fully realized. Flexible voice communications network and digital data communication system could allow more flexible FAM operations but they are not as essential.

dynamic airspace configuration↗

Mechanism Design for Demand Response Programs

Demand response (DR) programs serve to reduce the consumption of electricity at times when the supply is scarce and expensive. Consumers or agents with flexible consumption profiles are recruited by an aggregator who manages the DR program. The aggregator calls on a subset of its pool of recruited agents to reduce their electricity use during DR events. Agents are paid for reducing their energy consumption from contractually established baselines. Baselines are counter-factual consumption estimates of the energy an agent would have consumed if they were not participating in the DR program. Baselines are used to determine payments to agents. This creates an incentive for agents to inflate their baselines in order to increase the payments they receive. There are several newsworthy cases of agents gaming their baseline for economic benefit. We propose a novel self-reported baseline mechanism (SRBM) where each agent reports its baseline and marginal utility. These reports are strategic and need not be truthful. Based on the reported information, the aggregator selects or calls on agents with a certain probability to meet the load reduction target. Called agents are paid for observed reductions from their self-reported baselines. Agents who are not called face penalties for consumption shortfalls below their baselines. Under SRBM, we show that truthful reporting of baseline consumption and marginal utility is a dominant strategy. Thus, SRBM eliminates the incentive for agents to inflate baselines. SRBM is assured to meet the load reduction target. To conclude, we show that SRBM is almost optimal in the metric of average cost of DR provision faced by the aggregator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemically Active, Porous 3D-Printed Thermoplastic Composites

Metal-organic frameworks (MOFs) exhibit exceptional properties and are widely investigated because of their structural and functional versatility relevant to catalysis, separations, and sensing applications. However, their commercial or large-scale application is often limited by their powder forms. To address this, we report the production of MOF-thermoplastic polymer composites accessed via a standard 3D printer. MOFs (Zeolitic imidazolate framework; ZIF-8) were successfully incorporated homogeneously into both poly(lactic acid) (PLA) and thermoplastic polyurethane (TPU) matrices, extruded into filaments, and utilized for on-demand access to 3D structures by fused-deposition modeling. Printed rigid PLA-MOF composites displayed good structural integrity, high surface area ((SA)avg = 531 m2 g-1) and hierarchical pore features. Flexible TPU-MOF composites (SAavg = 706 m2 g-1) were achieved by employing a sacrificial fluoropolymer readily removed post-printing. Critically, embedded particles in the plastic matrices retain their ability to participate in chemical interactions characteristic of the parent MOF. The fabrication strategies can be extended to other MOFs and illustrate the potential of 3D printing to create unique porous and high surface area chemically-active structures.

Additive Manufacturing, Metal-Organic Framework, 3↗

Probabilistic Hydropower Flexibility Valuation: Case Studies for Boating Flow Regime

The optimal scheduling of hydropower generation holds significant importance to power system operation. The unique requirements of environmental constraints and the power system, depending on their respective objectives, demand distinct flow patterns. While power system stakeholders strive to optimize revenue in electricity markets, stakeholders from boating recreation seeks to identify flow ranges that optimize the boating experience. In pursuit of a win-win solution, this study aims to reconcile the interests of various stakeholders in hydropower scheduling. The maximum revenue from day-ahead electricity market is explored through an optimization process considering both plant operation constraints, boating flow constraints, water availability, and market prices. Results of real world case studies at a river in California show that the proposed approach can achieve dual objectives: maximizing market revenue while addressing boating recreation necessities. In addition, as the accuracy of electricity price forecasting and flow forecasting increase, the optimal revenue becomes increasingly advantageous to hydropower plant operators.

13 HYDRO ENERGY↗

Flexible and Scalable Data Fusion using Proactive, Schemaless Information Services

Exascale data environments are fast approaching, driven by diverse structured and unstructured data such as system and application telemetry streams, open-source information capture, and on-demand simulation output. Storage costs having plummeted, the question is now one of converting vast stores of data to actionable information. Complicating this problem are the low degrees of awareness across domain boundaries about what potentially useful data may exist, and write-once-read- never issues (data generation/collection rates outpacing data analysis and integration rates). Increasingly, technologists and researchers need to correlate previously unrelated data sources and artifacts to produce fused data views for domain-specific purposes. New tools and approaches for creating such views from vast amounts of data are vitally important to maintaining research and operational momentum. We propose to research and develop tools and services to assist in the creation, refinement, discovery and reuse of fused data views over large, diverse collections of heterogeneously structured data. We innovate in the following ways. First, we enable and encourage end-users to introduce customized index methods selected for local benefit rather than for global interaction (flexible multi-indexing). We envision rich combinations of such views on application data: views that span backing stores with different semantics, that introduce analytic methods of indexing, and that define multiple views on individual data items. We specifically decline to build a big fused database of everything providing a centralized index over all data, or to export a rigid schema to all comers as in federated query approaches. Second, we proactively advertise these application-specific views so that they may be programmatically reused and extended (data proactivity). Through this mechanism, both changes in state (new data in existing view collected) and changes in structure (new or derived view exists) are made known. Lastly, we embrace found data heterogeneity by coupling multi-indexing to backing stores with appropriate semantics (as opposed to a single store or schema).

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗