Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data reduction techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Data-Driven Discovery of Bimetallic Nanoparticles Catalysts for the Hydrogenolysis of Polyethylene

Supported platinum nanoparticles are known to convert polyolefins to high-quality liquid hydrocarbons with hydrogen under relatively mild conditions. However, no systematic study has been undertaken using bimetallic catalysts for polyethylene upcycling. Specifically, a total of 98 monometallic and bimetallic combinations (Ag, Cr, Co, Cu, Fe, Ga, In, Mn, Ni, Pd, Pt, Rh, Ru, Zr) on alumina were synthesized utilizing surface organometallic chemistry (SOMC) technique via robotic platform. These were investigated at a small scale (10 mg of catalyst and 50 mg of polyethylene) for their activity for the hydrogenolysis of polyethylene in a high-throughput batch reactor. Combinations of Ni and Co were selected as candidates with high activity toward conversion into paraffin oils. Reaction conditions were optimized with Ni/Co/Al 2 O 3 catalyst at a larger scale (300 mg catalyst and 3 g polyethylene) to obtain a high yield (93.1%) of paraffin wax with desired properties (M n = 380 Da) and low polydispersity (Đ = 1.2). Ni/Co/Al 2 O 3 was compared against Co/Ni/Al 2 O 3 to understand the role of the deposition sequence. When Co is deposited before Ni, a layer of cobalt aluminate is formed upon reduction, stabilizing the deposition of 5 nm metallic Ni particles. When nickel is deposited before Co, particles are larger (average >20 nm) and more oxidized (Ni δ+ in NiAl 2 O 4 ), decreasing the availability of the catalytically active metallic Ni. In conclusion, the difference in electronic environments was also described by DFT calculations, which revealed that smaller 3D clusters of Ni are preferred on CoAl2O4 over the 3D clusters on NiAl 2 O 4 and that these smaller clusters are more reducible, as confirmed experimentally.

Polymer↗

Direct observations of damage during unconfined brittle failure of Carrara marble

Abstract To observe and quantify the production of microfracturing from initial yield to failure, we deformed Carrara marble samples in uniaxial compression at 20, 105, and 180°C and continuously observed a region of about 1 mm 2 on an exposed face with a long‐working distance microscope. Using image processing and microscale strain‐mapping techniques, we measured local strains over a length scale of tens of micrometers. By treating the images with various filters, we identified linear damage features, as well as the magnitude of localized strain and the mode of deformation, i.e., shear versus normal deformation. In general, shear deformation is more prevalent after initial yielding, while tensile deformation dominates closer to peak stress. Independent measurements of both stress and microcrack density at different stages of each experiment provide a unique opportunity to explicitly compare the data with damage models. The model of Ashby and Sammis (1990) significantly underestimated the damage that the rock could sustain before peak stress, perhaps owing to the influence of weak grain boundaries on the damage production. In these samples, microcracks tended to form near boundaries before yield stress. During strain hardening, the damage parameters increased rapidly as longer microcracks grew along the boundaries and finally transected grains as loading neared peak stress. The microcrack density can be empirically related to the reduction of Young's modulus; stiffness ratios decay exponentially with increasing microcrack density for T ≤ 105°C.

Tal, Yuval↗

Technical and Imaging Outcomes from the UK Registry of Prostate Artery Embolization (UK-ROPE) Study: Focusing on Predictors of Clinical Success

Introduction: The UK Registry of Prostate Artery Embolization (UK-ROPE) was a prospective, multicentre study comparing PAE against surgical therapies for symptomatic benign prostatic hyperplasia (BPH). A wealth of data was collected supplementary to the main study outcomes which provide a snapshot of UK PAE practice. We aimed to interpret these data in the hope of providing insight into factors which affect clinical outcome and radiation dose. Methods: 216 patients (mean age 66, mean IPSS 21.3) undergoing PAE at 20 British centres from July 2014 to January 2016 were prospectively followed up to 12 months with retrospective analysis of the data. Technical outcome was evaluated based on procedural and fluoroscopy times, skin dose and dose area product (DAP). Clinical outcome was evaluated through collection of Qmax, IPSS reduction and prostate volume reduction. Multiple analysis of variance (MANOVA) was used to assess the significance of various patients and procedural factors on clinical outcome and patient dose. Results: Significant predictors of technical outcome which affected patient skin dose included severity of CTA-detected atheroma (p < 0.001), the practitioner (p < 0.001) and use of protective coil embolization (p = 0.019). Predictors of clinical outcome included initial prostate size (dichotomized into groups > 80 ml and = <80 ml, d = 1, p = 0.0138), embolic agent (spherical particles < 300 nm performed best, p = 0.01) and number of arteries embolized (IPSS reduction of 32.9% in unilateral PAE versus 54.4% for bilateral PAE, p = 0.026). Conclusion: We have identified several important factors which are associated with improved clinical outcome and increased patient dose which we hope will facilitate optimal patient selection and encourage improved embolization technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interpretable and flexible non-intrusive reduced-order models using reproducing kernel Hilbert spaces

This paper develops an interpretable, non-intrusive reduced-order modeling technique using regularized kernel interpolation. Existing non-intrusive approaches approximate the dynamics of a reduced-order model (ROM) by solving a data-driven least-squares regression problem for low-dimensional matrix operators. Our approach instead leverages regularized kernel interpolation, which yields an optimal approximation of the ROM dynamics from a user-defined reproducing kernel Hilbert space. We show that our kernel-based approach can produce interpretable ROMs whose structure mirrors full-order model structure by embedding judiciously chosen feature maps into the kernel. The approach is flexible and allows a combination of informed structure through feature maps and closure terms via more general nonlinear terms in the kernel. We also derive a computable a posteriori error bound that combines standard error estimates for intrusive projection-based ROMs and kernel interpolants. In conclusion, the approach is demonstrated in several numerical experiments that include comparisons to operator inference using both proper orthogonal decomposition and quadratic manifold dimension reduction.

Data-driven model reduction↗

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage induced by intense synchrotron radiation sources is indispensable for the correct interpretation of scattering data, there is still a lack of effective methods to overcome radiation-induced aggregation and extract scattering profiles free from chemical or structural damage. It is found that radiation-induced aggregation mainly begins on the surface of the sample cell and grows along the beam path; the diameter of the damaged region is comparable to the x-ray beam size. Radiation-induced aggregation can be effectively avoided by using a two-dimensional scan (2D mode), with an interval as small as 1.5 times the beam size, at low temperature (e.g., 4 deg. C). A radiation sensitive protein, bovine hemoglobin, was used to test the method. A standard deviation of less than 5% in the small angle region was observed from a series of nine spectra recorded in 2D mode, in contrast to the intensity variation seen using the conventional stationary technique, which can exceed 100%. Wide-angle x-ray scattering data were collected at a standard macromolecular diffraction station using the same data collection protocol and showed a good signal/noise ratio (better than the reported data on the same protein using a flow cell). The results indicate that this method is an effective approach for obtaining precise measurements of protein solution scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GNOSIS: THE FIRST INSTRUMENT TO USE FIBER BRAGG GRATINGS FOR OH SUPPRESSION

The near-infrared is an important part of the spectrum in astronomy, especially in cosmology because the light from objects in the early universe is redshifted to these wavelengths. However, deep near-infrared observations are extremely difficult to make from ground-based telescopes due to the bright background from the atmosphere. Nearly all of this background comes from the bright and narrow emission lines of atmospheric hydroxyl (OH) molecules. The atmospheric background cannot be easily removed from data because the brightness fluctuates unpredictably on short timescales. The sensitivity of ground-based optical astronomy far exceeds that of near-infrared astronomy because of this long-standing problem. GNOSIS is a prototype astrophotonic instrument that utilizes 'OH suppression fibers' consisting of fiber Bragg gratings and photonic lanterns to suppress the 103 brightest atmospheric emission doublets between 1.47 and 1.7 {mu}m. GNOSIS was commissioned at the 3.9 m Anglo-Australian Telescope with the IRIS2 spectrograph to demonstrate the potential of OH suppression fibers, but may be potentially used with any telescope and spectrograph combination. Unlike previous atmospheric suppression techniques GNOSIS suppresses the lines before dispersion and in a manner that depends purely on wavelength. We present the instrument design and report the results of laboratory and on-sky tests from commissioning. While these tests demonstrated high throughput ( Almost-Equal-To 60%) and excellent suppression of the skylines by the OH suppression fibers, surprisingly GNOSIS produced no significant reduction in the interline background and the sensitivity of GNOSIS+IRIS2 is about the same as IRIS2. It is unclear whether the lack of reduction in the interline background is due to physical sources or systematic errors as the observations are detector noise dominated. OH suppression fibers could potentially impact ground-based astronomy at the level of adaptive optics or greater. However, until a clear reduction in the interline background and the corresponding increasing in sensitivity is demonstrated optimized OH suppression fibers paired with a fiber-fed spectrograph will at least provide a real benefit at low resolving powers.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Clustering-Based Scenario Generation Framework for Power Market Simulation with Wind Integration

A critical step in stochastic optimization models of power system analysis is to select a set of appropriate scenarios and significant numbers of scenario generation methods exist in the literature. This paper develops a clustering based scenario generation method, which aims to improve the performance of existing scenario generation techniques by grouping a set of correlated wind sites into clusters according to their cross-correlations. Copula based models are utilized to model spatiotemporal correlations and the Gibbs sampling is then used to generate scenarios for day-ahead markets. Our results show that the generated scenarios based on clustered wind sites outperform existing approaches in terms of reliability and sharpness and can reduce the total computational time for scenario generation and reduction significantly. The clustering-based framework can therefore provide a better support for real-world market simulations with high wind penetration.

data visualization↗

Efficient optimal reconstruction of linear fields and band-powers from cosmological data

We present an efficient implementation of Wiener filtering of real-space linear field and optimal quadratic estimator of its power spectrum Band-powers. We first recast the field reconstruction into an optimization problem, which we solve using quasi-Newton optimization. We then recast the power spectrum estimation into the field marginalization problem, from which we obtain an expression that depends on the field reconstruction solution and a determinant term. We develop a novel simulation based method for the latter. We extend the simulations formalism to provide the covariance matrix for the power spectrum. We develop a flexible framework that can be used on a variety of cosmological fields and present results for a variety of test cases, using simulated examples of projected density fields, projected shear maps from galaxy lensing, and observed Cosmic Microwave Background (CMB) temperature anisotropies, with a wide range of map incompleteness and variable noise. For smaller cases where direct numerical inversion is possible, we show that our solution matches that created by direct Wiener Filtering at a fraction of the overall computation cost. Even more significant reduction of computational is achieved by this implementation of optimal quadratic estimator due to the fast evaluation of the Hessian matrix. This technique allows for accurate map and power spectrum reconstruction with complex masks and nontrivial noise properties.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.

60 APPLIED LIFE SCIENCES↗

Applying Waveform Correlation to Aftershock Sequences Using a Global Sparse Network

Agencies that monitor for underground nuclear tests are interested in techniques that automatically characterize earthquake aftershock sequences to reduce the human analyst effort required to produce high-quality event bulletins. Waveform correlation is effective in detecting similar seismic waveforms from repeating earthquakes, including aftershock sequences. We report the results of an experiment that uses waveform templates recorded by multiple stations of the Comprehensive Nuclear-Test-Ban Treaty International Monitoring System during the first twelve hours after a mainshock to detect and identify aftershocks that occur during the subsequent week. We discuss approaches for station and template selection, threshold setting, and event detection that are specialized for aftershock processing for a sparse, global network. We apply the approaches to three aftershock sequences to evaluate the potential for establishing a set of standards for aftershock waveform correlation processing that can be effective for operational monitoring systems with a sparse network. We compare candidate events detected with our processing methods to the Reviewed Event Bulletin of the International Data Center to develop an intuition about potential reduction in analyst workload.

58 GEOSCIENCES↗

3'-deoxy-3'-[{sup 18}F]fluorothymidine PET Quantification of Bone Marrow Response to Radiation Dose

Purpose: The purpose of this study was to quantify the relationship of bone marrow response to radiation dose, using 3'-deoxy-3'-[{sup 18}F]fluorothymidine ([{sup 18}F]FLT)-labeled uptake quantified in positron-emission tomography (PET) scans. Methods and Materials: Pre- and post-Week 1 treatment [{sup 18}F]FLT PET images were registered to the CT images used to create the radiation treatment plan. Changes in [{sup 18}F]FLT uptake values were measured using profile data of standardized uptake values (SUVs) and doses along the vertebral bodies located at a field border where a range of radiation doses were present for 10 patients. Data from the profile measurements were grouped into 1 Gy dose bins from 1 to 9 Gy to compare SUV changes for all patients. Additionally, the maximum pretreatment, the post-Week 1 treatment, and the dose values located within the C6-T7 vertebrae that straddled the field edge were measured for all patients. Results: Both the profile and the individual vertebral data showed a strong correlation between SUV change and radiation dose. Relative differences in SUVs between bins >1 Gy and <7 Gy were statistically significant (p < 0.01, two-sample t test). The reduction in SUV was approximately linear until it reached a reduction threshold of 75%-80% in SUV for doses greater than 6 Gy/week for both the dose-binned data and the vertebral maximum SUVs. Conclusions: The change in SUV observed in head and neck cancer patients treated with chemoradiation shows the potential for using [{sup 18}F]FLT PET images for identifying active bone marrow and monitoring changes due to radiation dose. Additionally, the change in [{sup 18}F]FLT uptake observed in bone marrow for different weekly doses suggests potential dose thresholds for reducing bone marrow toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ceria-based Catalysts for the Production of H2 Through the Water-gas-shift Reaction: Time-Resolved XRD and XAFS Studies

Hydrogen is a potential alternate energy source for satisfying many of our energy needs. In this work, we studied H2 production from the water-gas-shift (WGS) reaction over Ce1-x Cu x O2 catalysts, prepared with a novel microemulsion method, using two synchrotron-based techniques: time-resolved X-ray diffraction (XRD) and X-ray absorption fine structure (XAFS). The results are compared with those reported for conventional CuO x /CeO2 and AuO x /CeO2 catalysts obtained through impregnation of ceria. For the fresh Ce1-x Cu x O2 catalysts, the results of XAFS measurements at the Cu K-edge indicate that Cu is in an oxidation state higher than in CuO. Nevertheless, under WGS reaction conditions the Ce1-x Cu x O2 catalysts undergo reduction and the active phase contains very small particles of metallic Cu and CeO2-x . Time-resolved XRD and XAFS results also indicate that Cud+ and Aud+ species present in fresh CuO x /CeO2 and AuO x /CeO2 catalysts do not survive above 200 C under the WGS conditions. In all these systems, the ceria lattice displayed a significant increase after exposure to CO and a decrease in H2O, indicating that CO reduced ceria while H2O oxidized it. Our data suggest that H2O dissociation occurred on the Ovacancy sites or the Cu-Ovacancy and Au-Ovacancy interfaces. The rate of H2 generation by a Ce0.95Cu0.05O2 catalyst was comparable to that of a 5 wt% CuO x /CeO2 catalyst and much bigger than those of pure ceria or CuO.

08 HYDROGEN↗

Split-field vs extended-field intensity-modulated radiation therapy plans for oropharyngeal cancer: Which spares the larynx? Which spares the thyroid?

Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques. To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.

61 RADIATION PROTECTION AND DOSIMETRY↗

PARLO: PArallel Run-Time Layout Optimization for Scientific Data Explorations with Heterogeneous Access Patterns

The size and scope of cutting-edge scientific simulations are growing much faster than the I/O and storage capabilities of their run-time environments. The growing gap is exacerbated by exploratory, data-intensive analytics, such as querying simulation data with multivariate, spatio-temporal constraints, which induces heterogeneous access patterns that stress the performance of the underlying storage system. Previous work addresses data layout and indexing techniques to improve query performance for a single access pattern, which is not sufficient for complex analytics jobs. We present PARLO a parallel run-time layout optimization framework, to achieve multi-level data layout optimization for scientific applications at run-time before data is written to storage. The layout schemes optimize for heterogeneous access patterns with user-specified priorities. PARLO is integrated with ADIOS, a high-performance parallel I/O middleware for large-scale HPC applications, to achieve user-transparent, light-weight layout optimization for scientific datasets. It offers simple XML-based configuration for users to achieve flexible layout optimization without the need to modify or recompile application codes. Experiments show that PARLO improves performance by 2 to 26 times for queries with heterogeneous access patterns compared to state-of-the-art scientific database management systems. Compared to traditional post-processing approaches, its underlying run-time layout optimization achieves a 56% savings in processing time and a reduction in storage overhead of up to 50%. PARLO also exhibits a low run-time resource requirement, while also limiting the performance impact on running applications to a reasonable level.

Computer Science↗

Light Water Reactor Sustainability Program Potential to Extend the Range of Established Online Monitoring Technologies, Such as Guided Waves in Nuclear Power Plant Systems

The Light Water Reactor Sustainability Program began to evaluate technologies that could be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real-time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for most nuclear power generation costs. This report describes the current state of research related to ultrasonic guided wave testing and its application to defect detection in commercial nuclear power plants. The report analyses the applicability of the guided wave technology to secondary piping systems and also study the potential for expanding the range of guided wave technology to include bent piping and other piping components. The ultrasonic guided waves can inspect long stretches of straight piping, however more complex geometries such as elbows, welds, and tees are causing spurious reflections and coherent noise which significantly decrease the sensitivity of the technique. The report analyses two approaches to suppression of coherent noise in guided wave systems: advanced signal processing and pattern recognition based on independent component analysis and blind source separation and hardware-based technique of piezoelectric paint which can be used to facilitate the propagation of mechanical stress waves through piping. It is demonstrated on simulated guided wave data that the independent component analysis is capable of separating different coherent noise components and segregating them from useful signal. The piezoelectric paint approach seem to be a viable alternative to the signal processing methods, however it requires significantly more complicated logistics and initial financial outlay. The future efforts will be concentrated on applying the independent component analysis to real-world guided wave data recorded by the guided wave monitoring system installed on the shell of the low-pressure feedwater heater 13A at Exelon Corporation’s Braidwood Nuclear Generating Station. Also, the joint EPRI-INL research efforts will focus on experimental evaluation of piezoelectric paint as a technique to extend the range of guided wave technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Substitutional Mechanism of Ni into the Wide-Band-Gap Semiconductor InTaO4 and its Implications for Water Splitting Activity in the Wolframite Structure Type

The mechanism of Ni substitution into the oxide semiconductor InTaO{sub 4} has been studied through a combination of structural and spectroscopic techniques, providing insights into its previously reported photoactivity. Magnetic susceptibility and X-ray absorption near-edge spectroscopy (XANES) measurements demonstrate that nickel is divalent within the host lattice. The combined refinement of synchrotron X-ray and neutron powder diffraction data indicates that the product of Ni doping has the stoichiometry of (In{sub 1-x}Ni{sub 2x/3}Ta{sub x/3})TaO{sub 4} with a solubility limit of x {approx} 0.18, corresponding to 12% Ni on the In site. Single-phase samples were only obtained at synthesis temperatures of 1150 C or higher due to the sluggish reaction mechanism that is hypothesized to result from small free energy differences between (In{sub 1-x}Ni{sub 2x/3}Ta{sub x/3})TaO{sub 4} compounds with different x values. Undoped InTaO{sub 4} is shown to have an indirect band gap of 3.96 eV, with direct optical transitions becoming allowed at photon energies in excess of 5.1 eV. Very small band-gap reductions (less than 0.2 eV) result from Ni doping, and the origin of the yellow color of (In{sub 1-x}Ni{sub 2x/3}Ta{sub x/3})TaO{sub 4} compounds instead results from a weak {sup 3}A{sub 2g} {yields} {sup 3}T{sub 1g} internal d {yields} d transition not associated with the conduction or valence band that is common to oxide compounds with Ni{sup 2+} in an octahedral environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PARLO: PArallel Run-Time Layout Optimization for Scientific Data Explorations with Heterogeneous Access Pattern

Download Citation Email Print Request Permissions Save to Project The size and scope of cutting-edge scientific simulations are growing much faster than the I/O and storage capabilities of their run-time environments. The growing gap is exacerbated by exploratory, data-intensive analytics, such as querying simulation data with multivariate, spatio-temporal constraints, which induces heterogeneous access patterns that stress the performance of the underlying storage system. Previous work addresses data layout and indexing techniques to improve query performance for a single access pattern, which is not sufficient for complex analytics jobs. We present PARLO a parallel run-time layout optimization framework, to achieve multi-level data layout optimization for scientific applications at run-time before data is written to storage. The layout schemes optimize for heterogeneous access patterns with user-specified priorities. PARLO is integrated with ADIOS, a high-performance parallel I/O middleware for large-scale HPC applications, to achieve user-transparent, light-weight layout optimization for scientific datasets. It offers simple XML-based configuration for users to achieve flexible layout optimization without the need to modify or recompile application codes. Experiments show that PARLO improves performance by 2 to 26 times for queries with heterogeneous access patterns compared to state-of-the-art scientific database management systems. Compared to traditional post-processing approaches, its underlying run-time layout optimization achieves a 56% savings in processing time and a reduction in storage overhead of up to 50%. PARLO also exhibits a low run-time resource requirement, while also limiting the performance impact on running applications to a reasonable level.

Gong, Zhenhuan↗