Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Critical current and stability tests of Nb 3 Sn for LBNL CCT magnet project

The Nb 3 Sn wires received from LBNL include the original round wires as well as the extracted wires from Rutherford cables. Total of 12 samples were prepared and heat treated. Five of them were tested for electric field versus current (E-I), among them 4 samples were further tested for electric field versus magnetic field (E-H). E-I traces were measured in magnetic field between 5 T and 8 T at 4.2 K. The critical currents of these sample are between 924 A and 993 A at 5 T. E-H measurements were performed at currents between 900 and 1500 A at 4.2 K. The stability currents, which is defined as the maximum current without quench during the E-H test, are determined to be between 1100 A and 1400 A. A separate Excel file presenting all the critical current and E-H curves is attached.

36 MATERIALS SCIENCE↗

Impact of Inverter-Based Resources on Grid Protection: A Review of Negative-Sequence Current Generation

The increasing integration of inverter-based resources (IBRs) in power grids poses challenges to traditional protection systems, primarily due to their different fault current signatures compared to conventional synchronous generators. Unlike synchronous generators whose fault response is dictated by their physical design, IBRs exhibit a wide range of fault characteristics due to manufacturer-specific control algorithms and settings. This dependence on proprietary control schemes makes modeling IBR behavior during faults significantly more complex, especially considering the rapid evolution of inverter technology and the diverse control strategies employed. While much research has focused on the positive-sequence current injections of IBRs during symmetrical faults, the understanding of negative-sequence current generation during non-symmetrical faults remains limited. This report provides an overview of current research on IBRs' negative-sequence current generation during unbalanced faults and its impact on protection schemes based on negative-sequence components. It covers both type III wind turbines and full-size converter-based IBRs. Additionally, this report reviews strategies for grid-forming controlled inverters to generate negative-sequence current during unbalanced faults, in addition to grid-following controlled ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From Ion Current to Electroosmotic Flow Rectification in Asymmetric Nanopore Membranes

Asymmetrically shaped nanopores have been shown to rectify the ionic current flowing through pores in a fashion similar to a p-n junction in a solid-state diode. Such asymmetric nanopores include conical pores in polymeric membranes and pyramidal pores in mica membranes. We review here both theoretical and experimental aspects of this ion current rectification phenomenon. A simple intuitive model for rectification, stemming from previously published more quantitative models, is discussed. We also review experimental results on controlling the extent and sign of rectification. It was shown that ion current rectification produces a related rectification of electroosmotic flow (EOF) through asymmetric pore membranes. We review results that show how to measure and modulate this EOF rectification phenomenon. Finally, EOF rectification led to the development of an electroosmotic pump that works under alternating current (AC), as opposed to the currently available direct current EOF pumps.Furthermore experimental results on AC EOF rectification are reviewed, and advantages of using AC to drive EOF are discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Plasmoid Instability in Evolving Current Sheets and Onset of Fast Reconnection

The scaling of the plasmoid instability maximum linear growth rate with respect to the Lundquist number S in a Sweet–Parker current sheet, ${\gamma }_{\max }\sim {S}^{1/4}$, indicates that at high S, the current sheet will break apart before it approaches the Sweet–Parker width. Therefore, a proper description for the onset of the plasmoid instability must incorporate the evolving process of the current sheet. We carry out a series of two-dimensional simulations and develop diagnostics to separate fluctuations from an evolving background. It is found that the fluctuation amplitude starts to grow only when the linear growth rate is sufficiently high $({\gamma }_{\max }{\tau }_{A}\gt O(1))$ to overcome advection loss and the stretching effect due to the outflow. The linear growth rate continues to rise until the sizes of plasmoids become comparable to the inner layer width of the tearing mode. At this point, the current sheet is disrupted and the instability enters the early nonlinear regime. The growth rate suddenly decreases, but the reconnection rate starts to rise rapidly, indicating that current sheet disruption triggers the onset of fast reconnection. We identify important timescales of the instability development, as well as scalings for the linear growth rate, current sheet width, and dominant wavenumber at disruption. These scalings depend not only on the Lundquist number, but also on the noise amplitude. A phenomenological model that reproduces scalings from simulation results is proposed. The model incorporates the effect of reconnection outflow, which is crucial for yielding a critical Lundquist number S c below which disruption does not occur. As a result, the critical Lundquist number S c is not a constant value, but has a weak dependence on the noise amplitude.

79 ASTRONOMY AND ASTROPHYSICS↗

Formation and Reconnection of Electron Scale Current Layers in the Turbulent Outflows of a Primary Reconnection Site

We simulate with 3D particle in cell, the spontaneous formation of turbulent outflows in an initially laminar 3D reconnecting current layer. We observe the formation of many secondary current layers and reconnection sites in the outflow. The approach we follow is to study each individual feature within the turbulent outflow. To identify all clusters of current in the outflow we use a clustering technique widely used in unsupervised machine learning: density-based spatial clustering of applications with noise. Once the clusters are identified we measure their size and compute reconnection indicators to establish which are undergoing reconnection. With this analysis we establish that the size of the current clusters reaches all the way from its initial system scale down to subelectron skin depth scale. We observe that the smaller current clusters are more prone to reconnecting and to releasing energy. We then find the process of reconnection of the smaller current cluster to be of the recently observed electron-only type that leaves the ions essentially unaffected.

79 ASTRONOMY AND ASTROPHYSICS↗

Beta-dependent Properties of Solar Wind Current Sheets at 1 au

We utilize plasma turbulence in interplanetary coronal mass ejections as a natural laboratory to analyze more than 4600 current sheets observed over a broad range of electron and proton beta values, 10 −2 ≲ β e ≲ 10 and 10 −3 ≲ β p ≲ 10. The analysis shows that the shear angle Δθ and the thickness λ CS of the current sheets depend on both electron and proton beta. Specifically, the dependencies on electron beta are Δθ ≈ 12.6° $β^{0.41}_{e}$ and, λ CS /λ p ≈ 1.9 $β^{0.26}_{e}$ where λ p is the local proton inertial length. We argue that the beta dependence of the shear angle is an intrinsic feature of solar wind turbulence arising from the natural correlation between turbulence intensity and plasma beta. In contrast, the beta dependence of current sheet scales is likely a general characteristic of plasma turbulence. According to recent theory, current sheets formed in turbulence are disrupted by the electron tearing instability once their thickness is smaller than a critical scale. We demonstrate that normalizing the thickness of current sheets by this critical scale eliminates the dependence on beta across the entire range of plasma beta. This observation not only supports the theory suggesting that current sheets mediate the transition from the inertial to the kinetic cascade through the electron tearing instability, but also demonstrates the plausibility of similar processes in astrophysical plasma. The presented results also indicate that the theory may be applicable beyond its formal limits, m e /m i ≪ β ≪ 1.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining non-standard neutrino interactions with neutral current events at long-baseline oscillation experiments

We explore, for the first time, neutral-current events at long-baseline experiments to constrain vector and axial-vector neutrino non-standard interactions (NSI) with quarks. We leverage the flavor dependence of NSIs to perform an oscillation analysis in the neutral- current channel. We first introduce a framework to parametrize the effect of NSI on the cross section. Then, as an example, we analyze NOvA neutral-current data which provides significantly improved constraints on the axial-vector NSI parameters $ {\varepsilon}_{\mu \mu}^A $,$ {\varepsilon}_{\tau \tau}^A $ and $ {\varepsilon}_{e\mu}^A $. This is highly complementary to constraints from SNO data, which, differently from long-baseline neutral current data, is not sensitive to isospin conserving NSIs $ {\varepsilon}_u^A $ = $ {\varepsilon}_d^A $. Additionally, we disfavor large values of the diagonal vectorial NSI $ {\varepsilon}_{\mu \mu}^{VV} $ and $ {\varepsilon}_{\tau \tau}^V $ which originate from the LMA-Dark solution. We also highlight the complementarity between NSI searches at oscillation experiments using charged current and neutral current channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage controlled reverse-bias tests. Here we instead present an investigation of perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers with better indium-doped tin oxide (ITO) coverage can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with the phosphonic-acid interface layer MeO-2PACz, with poorer ITO coverage compared to PTAA, exhibit soft, gradual, and largely recoverable degradation, regardless of the shading conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more severe degradation than higher currents over shorter periods. Combining electrical measurements with spatially resolved photoluminescence imaging, we argue against shunt formation and instead support an ion- and charge-mediated interfacial electrochemical degradation mode.

Applied Physics (physics.app-ph)↗

Measurement of internal dark current in a 17 GHz accelerator structure with an elliptical sidewall

A 17 GHz single cell, standing wave, copper accelerator structure with an axisymmetric elliptical central cell sidewall was tested for internal and downstream dark current as a function of gradient up to 93 MV/m. The elliptical sidewall was predicted to suppress the internal dark current and the lower order multipactor modes as compared with a previously tested structure having a straight sidewall. During the conditioning phase of the elliptical sidewall structure, strong internal dark current generated by an N = 1 multipactor mode was observed at gradients in the 10 to 20 MV/m range. After conditioning with 2.2x10^5 pulses to 93 MV/m, the N = 1 mode was completely suppressed and no multipactor resonances were observed. The internal dark current was reduced to a comparatively low level, much smaller than in the previously studied, straight sidewall structure, in good agreement with simulations. The energy spectrum of the electrons colliding with the sidewall was measured using an isolated side dark current monitor and a bias voltage. As the conditioning progressed, the electron energy spectrum showed an increase in the concentration of lower energy electrons, also in good agreement with simulations. Studies of internal dark current may help to understand the rf conditioning and ultimate performance of high gradient accelerator structures.

43 PARTICLE ACCELERATORS↗

The high current, fast, 100ns, Linear Transformer Driver (LTD) developmental project at Sandia Laboratories and HCEI.

Sandia National Laboratories, Albuquerque, N.M., USA, in collaboration with the High Current Electronic Institute (HCEI), Tomsk, Russia, is developing a new paradigm in pulsed power technology: the Linear Transformer Driver (LTD) technology. This technological approach can provide very compact devices that can deliver very fast high current and high voltage pulses straight out of the cavity with out any complicated pulse forming and pulse compression network. Through multistage inductively insulated voltage adders, the output pulse, increased in voltage amplitude, can be applied directly to the load. The load may be a vacuum electron diode, a z-pinch wire array, a gas puff, a liner, an isentropic compression load (ICE) to study material behavior under very high magnetic fields, or a fusion energy (IFE) target. This is because the output pulse rise time and width can be easily tailored to the specific application needs. In this paper we briefly summarize the developmental work done in Sandia and HCEI during the last few years, and describe our new MYKONOS Sandia High Current LTD Laboratory. An extensive evaluation of the LTD technology is being performed at SNL and the High Current Electronic Institute (HCEI) in Tomsk Russia. Two types of High Current LTD cavities (LTD I-II, and 1-MA LTD) were constructed and tested individually and in a voltage adder configuration (1-MA cavity only). All cavities performed remarkably well and the experimental results are in full agreement with analytical and numerical calculation predictions. A two-cavity voltage adder is been assembled and currently undergoes evaluation. This is the first step towards the completion of the 10-cavity, 1-TW module. This MYKONOS voltage adder will be the first ever IVA built with a transmission line insulated with deionized water. The LTD II cavity renamed LTD III will serve as a test bed for evaluating a number of different types of switches, resistors, alternative capacitor configurations, cores and other cavity components. Experimental results will be presented at the Conference and in future publications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric current locator

The disclosure herein provides an apparatus for location of a quantity of current vectors in an electrical device, where the current vector has a known direction and a known relative magnitude to an input current supplied to the electrical device. Mathematical constants used in Biot-Savart superposition equations are determined for the electrical device, the orientation of the apparatus, and relative magnitude of the current vector and the input current, and the apparatus utilizes magnetic field sensors oriented to a sensing plane to provide current vector location based on the solution of the Biot-Savart superposition equations. Description of required orientations between the apparatus and the electrical device are disclosed and various methods of determining the mathematical constants are presented.

47 OTHER INSTRUMENTATION↗

Apparatuses and method for converting electromagnetic radiation to direct current

An energy conversion device may include a first antenna and a second antenna configured to generate an AC current responsive to incident radiation, at least one stripline, and a rectifier coupled with the at least one stripline along a length of the at least one stripline. An energy conversion device may also include an array of nanoantennas configured to generate an AC current in response to receiving incident radiation. Each nanoantenna of the array includes a pair of resonant elements, and a shared rectifier operably coupled to the pair of resonant elements, the shared rectifier configured to convert the AC current to a DC current. The energy conversion device may further include a bus structure operably coupled with the array of nanoantennas and configured to receive the DC current from the array of nanoantennas and transmit the DC current away from the array of nanoantennas.

30 DIRECT ENERGY CONVERSION↗

Current limiter circuit system

An apparatus comprising a steady state sensing circuit, a switching circuit, and a detection circuit. The steady state sensing circuit is connected to a first, a second and a third node. The first node is connected to a first device, the second node is connected to a second device, and the steady state sensing circuit causes a scaled current to flow at the third node. The scaled current is proportional to a voltage difference between the first and second node. The switching circuit limits an amount of current that flows between the first and second device. The detection circuit is connected to the third node and the switching circuit. The detection circuit monitors the scaled current at the third node and controls the switching circuit to limit the amount of the current that flows between the first and second device when the scaled current is greater than a desired level.

42 ENGINEERING↗

Supply-noise-rejecting current source

Various technologies pertaining to a high-impedance current source are described herein. The current source outputs a substantially constant current by way of a first transistor that draws current from a supply. The current source is configured to feed back noise from the supply to a feedback resistor at an input of an operational amplifier (op-amp) by way of a second transistor. The feedback resistor and the op-amp are configured such that responsive to receiving the supply noise feedback, the op-amp drives a gate voltage of the first transistor to cause the first transistor to reject the supply noise and cause the output of the current source to remain substantially constant.

Wessendorf, Kurt O.↗

Supply-noise-rejecting current source

Various technologies pertaining to a high-impedance current source are described herein. The current source outputs a substantially constant current by way of a first transistor that draws current from a supply. The current source is configured to feed-back noise from the supply to a feedback resistor at an input of an operational amplifier (op-amp) by way of a second transistor. The feedback resistor and the op-amp are configured such that responsive to receiving the supply noise feedback, the op-amp drives a gate voltage of the first transistor to cause the first transistor to reject the supply noise and cause the output of the current source to remain substantially constant.

42 ENGINEERING↗

Simulating current flow through a well casing and an induced fracture

A system includes a receiver component that receives a model of a well system, the model comprising a representation of an electrically energized well casing and/or a fracture as a transmission line that leaks electric current as the current traverses the well casing and/or fracture. The receiver component also receives a value that indicates an amount of the current that is applied to the well casing and a location of a source of the current on the well casing. The system further includes an electromagnetic field calculator component that calculates an estimated electromagnetic field at at least one location on the surface of the earth based at least in part upon the representation of the electrically energized well casing and/or fracture, the value that indicates the amount of current that is applied to the well casing, and the location of the source of the current on the well casing.

02 PETROLEUM↗

System and method for implementing a zero-sequence current filter for a three-phase power system

In a three-phase, four-wire electrical distribution system, a zig-zag transformer and at least one Cascade Multilevel Modular Inverter (CMMI) is coupled between the distribution system and the neutral. A controller modulates the states of the H-bridges in the CMMI to build an AC waveform. The voltage is chosen by the controller in order to control an equivalent impedance that draws an appropriate neutral current through the transformer. This neutral current is generally chosen to cancel the neutral current sensed in the line. The chosen neutral current may be based on a remotely sensed imbalance, rather than on a local value, determined by the power utility as a critical load point in the system. The desired injection current is then translated by the controller into a desired zero-sequence reactive impedance, based on measurement of the local terminal voltage, allowing the controller to regulate the current without generating or consuming real power.

Benavides, Nicholas↗

Application of Frequency Division Multiplexing and Neural Networks in the Operation and Diagnosis of the Stator Current and Shaft Position Sensors Used in Electric/Hybrid Vehicles

Fast, precise and robust sensing of currents and motor shaft angle is essential for the excellent performance of electric and hybrid vehicles (EV/HEV). Multiplexing techniques are commonly applied in data acquisition systems (DAQs) to digitize the signals sensed in EV/HEV drives. Frequency-division multiplexing (FDM) applied to get the signals from current sensors and resolver angular position sensor has advantages over conventional multiplexing approaches. However, problems such as aging and mechanical imperfections distort the outputs of those sensors, producing measurement errors of the angular position and currents. Conventional techniques designed to compensate for those errors cannot be applied in signals multiplexed in frequency. This paper proposes online techniques to detect and compensate for the distortions in the resolver sensor and current sensors. The demultiplexing process was adjusted to allow distortion detection and compensation. An auto-associative neural network (ANN) compensates for the current measurement error, while an energy-based technique is applied to compensate for the distortions in the resolver outputs. The obtained results show that the distortions were compensated, allowing a more accurate estimation of stator currents and angular position when FDM is applied in EV/HEV DAQs.

Pereira Pinto, Joao↗