Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Rapidly Deployable Acoustic Monitoring and Localization System Based on a Low-Cost Wave Buoy Platform

The primary objective of this project is to develop a cost-effective, fit-for-purpose environmental monitoring system, “NoiseSpotter®,” that characterizes, classifies, and provides accurate location information for anthropogenic and natural sounds in near real-time. NoiseSpotter was developed to support the evaluation of potential acoustic effects of marine energy (ME) projects. By utilizing a compact array of three acoustic particle motion sensors, NoiseSpotter triangulates individual bearings to provide sound source localization to within 5% accuracy, allowing the ability to discern ME device sounds relative to other confounding sounds in the environment, while providing location estimates to nearby marine mammals for environmental mitigation purposes. The ME industry needs proven solutions to meet environmental impact assessment needs. The NoiseSpotter® includes off-the-shelf, modular components that are easy to assemble and disassemble. Its acoustic particle motion sensors are commercially available and the data logger and real-time telemetry system is designed to be plug-and-play. The entire system is relatively compact and can be deployed from small vessels. NoiseSpotter’s near real-time capability enables operational monitoring of ME sounds, particularly during early stages of technology adoption to facilitate mitigation of potential noise effects. Widespread adoption of the technology for acoustic monitoring of ME devices requires that it be cost effective; hence the anticipated commercial cost of system hardware is $35,000. This project contributes to reducing barriers to ME testing through support of scientific research focused on reducing or mitigating environmental risks and lowering costs and complexity of environmental monitoring. This project has developed an acoustic monitoring system, NoiseSpotter® (U.S. Patent No. 11,156,734 and U.S. Registered Trademark No. 6,442,313), to detect and characterize baseline noise and sounds from ME operations and support geolocation of detected sounds. The intended outcome of the project is to mitigate concerns about the potential for ME device noise to alter marine mammal or fish behavior. NoiseSpotter® enables cost-effective, near real-time acoustic monitoring of an operational ME device relative to ambient environmental noise and provides a technical basis for ME developers seeking to navigate the permitting process in an efficient manner.

16 TIDAL AND WAVE POWER↗

Addressing energy storage needs at lower cost via on-site thermal energy storage in buildings

Cost-effective energy storage is a critical enabler for the large-scale deployment of renewable electricity. Significant resources have been directed toward developing cost-effective energy storage, with research and development efforts dominated by work on lithium ion (Li-ion) battery technology. Though Li-ion batteries have many attractive qualities, it is not clear whether they can provide an affordable levelized cost of storage (LCOS) for certain applications, such as buildings. Buildings consume most of the world's electricity, and as much as 50% of their consumption goes toward meeting thermal loads. Thermal energy storage (TES) can provide a cost-effective alternative to Li-ion batteries for buildings; however, two questions remain to be answered. First, how much of total building energy storage requirements can be met via thermal storage for building loads? Second, can the LCOS for TES be favorable compared with Li-ion batteries? In this perspective, using the United States as a case study, we show that the total requirement for TES in buildings is in the range of ~1200–4500 electrical GW h, depending on the fraction of solar versus wind in the generation mix. Furthermore, we show that with at least 25% wind generation, all of the storage needed by buildings to support the grid can be met by TES. We also introduce a framework to calculate LCOS for on-site TES in buildings to enable a direct comparison with electrical storage technologies such as Li-ion batteries. This is not trivial, because the input energy type for TES (electricity) differs from the output energy type (thermal energy), and the efficiency can depend on ambient conditions. Our LCOS analysis shows that in many situations, TES can be more cost-effective for buildings than Li-ion batteries. We conclude our perspective by discussing future research and development opportunities that can significantly advance the deployment of TES for buildings to help enable a renewable electricity-dependent grid.

25 ENERGY STORAGE↗

Optimization of Low Level Waste Disposal Policy, Strategies and Techniques - 17201

The mission of low level radioactive waste disposal facilities is to accept and dispose of waste in compliance with all applicable laws, regulations, license requirements, and social expectations. These facilities need to provide a cost effective disposal service to the waste generators, so that the cost savings could be passed down to business, industry, and ultimately, to the general public. To fulfil this mission, waste disposal facilities need to establish and maintain review and optimization mechanisms to respond to changing circumstances that may impact the long-term safe, cost effective operation of their facilities. Maintaining existing disposal resources available as long as possible, managing increased demand for disposal space as a consequence of growing number of nuclear facilities to be decommissioned, and developing capacity for future needs and uncertainties are some of the key challenges that drive optimization of disposal facilities. While the concept of optimization of low level waste disposal facilities is not new, the framework for holistic optimization of waste disposal facilities, enabling them to provide cost effective, sustainable services to the nuclear industry, as well as maintaining optimized safety and radiation protection systems is a notable gap in the current radioactive waste management body of knowledge. A comprehensive optimization framework is required to support the implementation of safe, effective, and sustainable integrated waste management strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical and mechanical metallurgy of high purity Nb for accelerator cavities

In the past decade, high Q values have been achieved in high purity Nb superconducting radio frequency (SRF) cavities. Fundamental understanding of the physical metallurgy of Nb that enables these achievements is beginning to reveal what challenges remain to establish reproducible and cost-effective production of high performance SRF cavities. Recent studies of dislocation substructure development and effects of recrystallization arising from welding and heat treatments and their correlations with cavity performance are considered. With better fundamental understanding of the effects of dislocation substructure evolution and recrystallization on electron and phonon conduction, as well as the interior and surface states, it will be possible to design optimal processing paths for cost-effective performance using approaches such as hydroforming, which minimizes or eliminates welds in a cavity.

43 PARTICLE ACCELERATORS↗

Assessment of Energy Efficiency Improvement and CO 2 Emission Reduction Potentials in the Iron and Steel Industry in China

China’s annual crude steel production in 2010 was 638.7 Mt accounting for nearly half of the world’s annual crude steel production in the same year. Around 461 TWh of electricity and 14,872 PJ of fuel were consumed to produce this quantity of steel in 2010. We identified and analyzed 23 energy efficiency technologies and measures applicable to the processes in the iron and steel industry. The Conservation Supply Curve (CSC) used in this study is an analytical tool that captures both the engineering and the economic perspectives of energy conservation. Using a bottom-up electricity CSC model, the cumulative cost-effective electricity savings potential for the Chinese iron and steel industry for 2010-2030 is estimated to be 251 TWh, and the total technical electricity saving potential is 416 TWh. The CO 2 emissions reduction associated with cost-effective electricity savings is 139 Mt CO 2 and the CO 2 emission reduction associated with technical electricity saving potential is 237 Mt CO2. The FCSC model for the iron and steel industry shows cumulative cost-effective fuel savings potential of 11,999 PJ, and the total technical fuel saving potential is 12,139. The CO 2 emissions reduction associated with cost-effective and technical fuel savings is 1,191 Mt CO 2 and 1,205 Mt CO 2 , respectively. In addition, a sensitivity analysis with respect to the discount rate used is conducted to assess the effect of changes in this parameter on the results. The result of this study gives a comprehensive and easy to understand perspective to the Chinese iron and steel industry and policy makers about the energy efficiency potential and its associated cost.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparative techno-economic assessment of osmotically-assisted reverse osmosis and batch-operated vacuum-air-gap membrane distillation for high-salinity water desalination

New developments in pressure- and thermally driven membrane desalination technologies offer the potential to cost-effectively treat high-salinity waters, especially when powered by low-cost solar electricity and thermal energy. This paper presents a comparative techno-economic assessment of the state-of-the-art most promising pressure- and thermally driven membrane technologies for high recovery desalination, namely, osmotically-assisted reverse osmosis (OARO) and batch-operated vacuum-air-gap membrane distillation (batch V-AGMD), to produce potable water while concentrating brine within the range of 140–290 g/L TDS for minimum-liquid-discharge (MLD) and zero-liquid-discharge (ZLD) applications. It is shown that both OARO and batch V-AGMD can treat feedwater and brines with TDS in the range of 30–125 g/L with corresponding fresh water recovery rates of 85–25%. When low cost solar electricity and thermal energy are used, the resulting levelized cost of water (LCOW) from OARO is in the range of 0.70–6.28 $/m 3 , and that from batch-V-AGMD is in the range of 1.74–2.77 $/m 3 . OARO is more cost-effective than batch V-AGMD when feedwater salinity is below 70 g/L and recovery below 75%, whereas batch V-AGMD is more cost-effective at higher recovery rates and salinity levels. Finally, the sensitivity of this comparison on energy prices and module costs is discussed.

42 ENGINEERING↗

Implications of stop-and-go traffic on training learning-based car-following control

Learning-based car-following control (LCC) of connected and autonomous vehicles (CAVs) is gaining significant attention with the advancement of computing power and data accessibility. While the flexibility and large model capacity of model-free architecture enable LCC to potentially outperform the model-based car-following (CF) model in improving traffic efficiency and mitigating congestion, the generalizability of LCC for traffic conditions different from the training environment/dataset is not well-understood. Herein, this study seeks to explore the impact of stop-and-go traffic in the training dataset on the generalizability of LCC. It uses the characteristics of lead vehicle trajectories to describe stop-and-go traffic, and links the theory of identifiability (i.e., obtaining a unique parameter estimation result using sensor measurements) to the generalizability of behavior cloning (BC) and policy-based deep reinforcement learning (DRL). Correspondingly, the study shows theoretically that: (i) stop-and-go traffic can enable the property of identifiability and enhance the control performance of BC-based LCC in different traffic conditions; (ii) stop-and-go traffic is not necessary for DRL-based LCC to generalize to different traffic conditions; (iii) DRL-based LCC trained with only constant-speed lead vehicle trajectories (not sufficient to ensure identifiability) can be generalized to different traffic conditions; and (iv) stop-and-go traffic increases variance in the training dataset, which improves the convergence of parameter estimation while negatively impacting the convergence of DRL to the optimal control policy. Numerical experiments validate the above findings, illustrating that BC-based LCC entails comprehensive training datasets for generalizing to different traffic conditions, while DRL-based LCC can achieve generalization with simple free-flow traffic training environments. This further suggests DRL as a more promising and cost-effective LCC approach to reduce operational costs, mitigate traffic congestion, and enhance safety and mobility, which can accelerate the deployment and acceptance of CAVs.

33 ADVANCED PROPULSION SYSTEMS↗

RS-25 for the NASA Cargo Launch Vehicle: The Evolution of SSME for Space Exploration

A key element of the National Vision for Space Exploration is the development of a heavy-lift Cargo Launch Vehicle (CaLV). Missions to the Moon, Mars, and beyond are only possible with the logistical capacity of putting large payloads in low-earth orbit. However, beyond simple logistics, there exists the need for this capability to be as cost effective as possible to ensure mission sustainability. An element of the CaLV project is, therefore, the development of the RS-25, which represents the evolution of the proven Space Shuttle Main Engine (SSME) into a high-performance, cost-effective expendable rocket engine. The development of the RS-25 will be built upon the foundation of over one million seconds of accumulated hot-fire time on the SSME. Yet in order to transform the reusable SSME into the more cost-effective, expendable RS-25 changes will have to be made. Thus the project will inevitably strive to maintain a balance between demonstrated heritage products and processes and the utilization of newer technology developments. Towards that end, the Core Stage Engine Office has been established at the NASA Marshall Space Flight Center to initiate the design and development of the RS-25 engine. This paper is being written very early in the formulation phase of the RS-25 project. Therefore the focus of this paper will be to present the scope, challenges, and opportunities for the RS-25 project. Early schedules and development decisions and plans will be explained. For not only must the RS-25 project achieve cost effectiveness through the development of new, evolved components such as a channel-wall nozzle, a new HIP-bonded main combustion chamber, and several others, it must simultaneously develop the means whereby this engine can be manufactured on a scale never envisioned for the SSME. Thus, while the overall project will span the next eight to ten years, there is little doubt that even this schedule is aggressive with a great deal of work to accomplish.

Kynard, Michael H.↗

Cyber Security Concerns for Sharing Distributed Antenna Systems

Wireless access to data is a challenge for environments with poor radio frequency coverage such as nuclear power plants. An 802.11 Wi-Fi data network is often not a cost-effective solution not a cost-effective solution due to the requirement for extensive antenna outlays in large nuclear facilities and poor signal penetration due to thick concrete walls. Combining commercial Long-Term Evolution (LTE) with an existing distributed antenna system’s (DAS) resources and infrastructure is an attractive solution due to and lower cost of implementation and likely coverage increases. A 2017 technical report by EPRI has demonstrated that multiple systems such as Land Mobile Radio (LMR) and LTE can be operated using the same DAS and by sharing the leaky coaxial cabling and indoor antenna systems (Reference 1). Since the radio frequency (RF) bands used by the two wireless systems are specified to be non-overlapping, it is believed that the systems are isolated from each other. No extensive analysis has been conducted to determine whether RF signals from one system sharing antennas and coaxial cable can influence another. This paper investigates the assumption of isolation between the two wireless systems and provides recommendations for future needed work to identify specific vulnerabilities and potential mitigations.

97 MATHEMATICS AND COMPUTING↗

Consolidation of graphite thermoplastic textile preforms for primary aircraft structure

The use of innovative cost effective material forms and processes is being considered for fabrication of future primary aircraft structures. Processes that have been identified as meeting these goals are textile preforms that use resin transfer molding (RTM) and consolidation forming. The Novel Composites for Wing and Fuselage Applications (NCWFA) program has as its objective the integration of innovative design concepts with cost effective fabrication processes to develop damage-tolerant structures that can perform at a design ultimate strain level of 6000 micro-inch/inch. In this on-going effort, design trade studies were conducted to arrive at advanced wing designs that integrate new material forms with innovative structural concepts and cost effective fabrication methods. The focus has been on minimizing part count (mechanical fasteners, clips, number of stiffeners, etc.), by using cost effective textile reinforcement concepts that provide improved damage tolerance and out-of-plane load capability, low-cost resin transfer molding processing, and thermoplastic forming concepts. The fabrication of representative Y spars by consolidation methods will be described. The Y spars were fabricated using AS4 (6K)/PEEK 150g commingled angle interlock 0/90-degree woven preforms with +45-degree commingled plies stitched using high strength Toray carbon thread and processed by autoclave consolidation.

Suarez, J.↗

Outcome of Patients Treated With a Single-Fraction Dose of Palliative Radiation for Cutaneous T-Cell Lymphoma

Purpose: Cutaneous T-cell lymphoma (CTCL) is a radiosensitive tumor. Presently, treatment with radiation is given in multiple fractions. The current literature lacks data that support single-fraction treatment for CTCL. This retrospective review assesses the clinical response in patients treated with a single fraction of radiation. Methods and Materials: This study reviewed the records of 58 patients with CTCL, primarily mycosis fungoides, treated with a single fraction of palliative radiation therapy (RT) between October 1991 and January 2011. Patient and tumor characteristics were reviewed. Response rates were compared using Fisher's exact test and multiple logistic regressions. Survival rates were determined using the Kaplan-Meier method. Cost-effectiveness analysis was performed to assess the cost of a single vs a multifractionated treatment regimen. Results: Two hundred seventy individual lesions were treated, with the majority (97%) treated with ≥700 cGy; mean follow-up was 41.3 months (range, 3-180 months). Response rate by lesion was assessed, with a complete response (CR) in 255 (94.4%) lesions, a partial response in 10 (3.7%) lesions, a partial response converted to a CR after a second treatment in 4 (1.5%) lesions, and no response in 1 (0.4%) lesion. The CR in lower extremity lesions was lower than in other sites (P=.0016). Lesions treated with photons had lower CR than those treated with electrons (P=.017). Patients with lesions exhibiting large cell transformation and tumor morphology had lower CR (P=.04 and P=.035, respectively). Immunophenotype did not impact response rate (P=.23). Overall survival was significantly lower for patients with Sézary syndrome (P=.0003) and erythroderma (P<.0001). The cost of multifractionated radiation was >200% higher than that for single-fraction radiation. Conclusions: A single fraction of 700 cGy-800 cGy provides excellent palliation for CTCL lesions and is cost effective and convenient for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An efficient Bayesian data-worth analysis using a multilevel Monte Carlo method

Improving the understanding of subsurface systems and thus reducing prediction uncertainty requires collection of data. As the collection of subsurface data is costly, it is important that the data collection scheme is cost-effective. Design of a cost-effective data collection scheme, i.e., data-worth analysis, requires quantifying model parameter, prediction, and both current and potential data uncertainties. Assessment of these uncertainties in large-scale stochastic subsurface hydrological model simulations using standard Monte Carlo (MC) sampling or surrogate modeling is extremely computationally intensive, sometimes even infeasible. In this paper, we propose an efficient Bayesian data-worth analysis using a multilevel Monte Carlo (MLMC) method. Compared to the standard MC that requires a significantly large number of high-fidelity model executions to achieve a prescribed accuracy in estimating expectations, the MLMC can substantially reduce computational costs using multifidelity approximations. Since the Bayesian data-worth analysis involves a great deal of expectation estimation, the cost saving of the MLMC in the assessment can be outstanding. While the proposed MLMC-based data-worth analysis is broadly applicable, we use it for a highly heterogeneous two-phase subsurface flow simulation to select an optimal candidate data set that gives the largest uncertainty reduction in predicting mass flow rates at four production wells. Finally, the choices made by the MLMC estimation are validated by the actual measurements of the potential data, and consistent with the standard MC estimation. But compared to the standard MC, the MLMC greatly reduces the computational costs.

97 MATHEMATICS AND COMPUTING↗

Multi-technology building system retrofits for utility incentive programs: Savings, costs and baseline considerations

Utility incentive programs are an important channel to support the deployment of energy efficiency in buildings. To date, these programs have largely been limited to single-component strategies. However, many utilities are now motivated to identify and develop multi-component system retrofits to achieve deeper energy savings, which are essential to achieving broader energy and greenhouse gas reduction goals in the buildings sector. In this paper we present the energy savings, demand reductions, and cost-effectiveness of 16 systems retrofit packages in six utility regions in the United States. These results are being used by these utilities to inform and develop incentive programs for systems retrofits. Our analysis shows that packages with proven lighting and HVAC measures can provide 5–22% whole building annual energy savings, and 13–22% annual energy costs savings, using utility incentive program baselines (code and existing building). The packages are reasonably cost effective for replace-on-burnout but generally not for a retrofit scenario prior to end of equipment life. Demand response can increase both the energy savings and energy cost savings, further improving the cost effectiveness of these packages. We analyzed the impact of using existing building vs. code baselines for calculating savings, showing that the choice of baseline in developing utility incentive programs has a substantial impact on the attributable energy savings to a program, with significant implications for the overall viability of a program (generally savings against existing building condition are higher and improve project and program cost-effectiveness).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A study of the relative effectiveness and cost of computerized information retrieval in the interactive mode

Results of a number of experiments to illuminate the relative effectiveness and costs of computerized information retrieval in the interactive mode are reported. It was found that for equal time spent in preparing the search strategy, the batch and interactive modes gave approximately equal recall and relevance. The interactive mode however encourages the searcher to devote more time to the task and therefore usually yields improved output. Engineering costs as a result are higher in this mode. Estimates of associated hardware costs also indicate that operation in this mode is more expensive. Skilled RECON users like the rapid feedback and additional features offered by this mode if they are not constrained by considerations of cost.

Smetana, F. O.↗

UTILIZING INNOVATIVE TECHNOLOGIES FOR ENVIRONMENTAL CLEAN-UP, SAVAHHAH RIVER SITE

The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy nuclear facility located along the Savannah River near Aiken, South Carolina. During operations, which started in 1951, hazardous substances (chemicals and radionuclides) were released to the environment. The releases occurred as a result of inadvertent spills and waste disposal in unlined pits and basins which was common practice before environmental regulations existed. The hazardous substances have migrated to the vadose zone and groundwater in many areas of the SRS, resulting in 515 waste units and facilities that are required by environmental regulations, to undergo characterization and, if needed, remediation. In the initial years of the SRS environmental cleanup program (early 1990s), the focus was to use common technologies (such as pump and treat, air stripping, excavation and removal) that actively and tangibly removed contamination. Exclusive use of these technologies required continued and significant funding while often failing to meet acceptable clean-up goals and objectives. Recognizing that a more cost-effective approach was needed, SRS implemented new and complementary remediation methods focused on active and passive technologies targeted to solve specific remediation problems. Today, SRS uses technologies such as chemical/pH-adjusting injection, phytoremediation, underground cutoff walls, dynamic underground stripping, soil fracturing, microbial degradation, baroballs, electrical resistance heating, soil vapor extraction, and microblowers to more effectively treat contamination at lower costs. Additionally, SRS's remediation approach cost effectively maximizes cleanup as SRS works proactively with multiple regulatory agencies. Using GIS, video, animation, and graphics, SRS is able to provide an accurate depiction of the evolution of SRS groundwater and vadose zone cleanup activities to convince stakeholders and regulators of the effectiveness of various cleanup technologies. Remediating large, complex groundwater plumes using state-of-the-art technologies and approaches is a hallmark of years of experience and progress. Environmental restoration at SRS continues to be a challenging and dynamic process as new cleanup technologies and approaches are adopted. technologies and approaches is a hallmark of years of experience and progress. Environmental restoration at SRS continues to be a challenging and dynamic process as new cleanup technologies and approaches are adopted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A 100 kW-Class Technology Demonstrator for Space Solar Power

A first step in the development of solar power from space is the flight demonstration of critical technologies. These fundamental technologies include efficient solar power collection and generation, power management and distribution, and thermal management. In addition, the integration and utilization of these technologies into a viable satellite bus could provide an energy-rich platform for a portfolio of payload experiments such as wireless power transmission (WPT). This paper presents the preliminary design of a concept for a 100 kW-class free-flying platform suitable for flight demonstration of technology experiments. Recent space solar power (SSP) studies by NASA have taken a stepping stones approach that lead to the gigawatt systems necessary to cost-effectively deliver power from space. These steps start with a 100 kW-class satellite, leading to a 500 kW and then a 1 MW-class platform. Later steps develop a 100 MW bus that could eventually lead to a 1-2 GW pilot plant for SSP. Our studies have shown that a modular approach is cost effective. Modular designs include individual laser-power-beaming satellites that fly in constellations or that are autonomously assembled into larger structures at geosynchronous orbit (GEO). Microwave power-beamed approaches are also modularized into large numbers of identical units of solar arrays, power converters, or supporting structures for arrays and microwave transmitting antennas. A cost-effective approach to launching these modular units is to use existing Earth-to-orbit (ETO) launch systems, in which the modules are dropped into low Earth orbit (LEO) and then the modules perform their own orbit transfer to GEO using expendable solar arrays to power solar electric thrusters. At GEO, the modules either rendezvous and are assembled robotically into larger platforms, or are deployed into constellations of identical laser power-beaming satellites. Since solar electric propulsion by the modules is cost-effective for both self-transport of the modules from LEO to GEO, and for on-orbit stationkeeping and repositioning capability during the satellite’s lifetime, this technology is also critical in technology development for SSP. The 100 kW-class technology demonstrator will utilize advanced solar power collection and generation technologies, power management and distribution, advanced thermal management, and solar electric propulsion. State-of-the-art solar concentrators, highly efficient multi-junction solar cells, integrated thermal management on the arrays, and innovative deployable structure design and packaging make the 100 kW satellite feasible for launch on one existing launch vehicle. Early SSP studies showed that a major percentage of the on-orbit mass for power-beaming satellites was from massive power converters at the solar arrays, at the bus, at the power transmitter, or at combinations of these locations. Higher voltage mays and power management and distribution (PMAD) systems reduce or eliminate the need for many of these massive power converters, and could enable direct-drive of high-voltage solar electric thrusters. Lightweight, highly efficient thermal management systems are a critical technology that must be developed and flown for SSP feasibility. Large amounts of power on satellites imply that large amounts of waste heat will need to be managed. In addition, several of the more innovative lightweight configurations proposed for SSP satellites take advantage of solar concentrators that are intractable without advanced thermal management technologies for the solar arrays. These thermal management systems include efficient interfaces with the WPT systems or other high-power technology experiments, lightweight deployable radiators that can be easily integrated into satellite buses, and efficient reliable thermal distribution systems that can pipe heat from the technology experiments to the radiators. In addition to demonstrating the integration and use of these mission-critical technologies, the 100 kw-class satellite will provide a large experiment deck for a portfolio of technology experiments. Current plans for this technology demonstrator allow 2000 kg of payload capability and up to 100 kW of power. The technology experiments could include one or more wireless power transmission demonstrations, either to the Earth’s surface or to a suitable space-based receiver. Technology experiments to quantify the on-orbit performance of critical technologies for SSP or space exploration are welcomed. In addition, the technology experiments provide an opportunity for international cooperation, to advance technology readiness levels of SSP technologies that require flight demonstration. This paper will present the preliminary design for a 100 kW solar-powered satellite and a variety of technology experiments that may be suitable for flight demonstration. In addition, a space-to-Earth-surface WPT experiment will be discussed.

Connie Carrington↗

Techno-economic analysis of DC power distribution in commercial buildings

Improvements in building end-use efficiency have significantly reduced the energy intensity of new buildings, but diminishing returns make it a challenge to build very-low energy buildings cost-effectively. A largely untapped efficiency strategy is to improve the efficiency of power distribution within buildings. Direct current (DC) distribution with modern power electronics has the potential to eliminate much of the power conversion loss in alternating current (AC) building distribution networks that include photovoltaics and DC end uses. Previous literature suggests up to 15% energy savings from DC power distribution in very energy efficient buildings with onsite generation and battery storage. This paper extends prior energy modeling of DC versus AC distribution in buildings, to consider the cost of implementing DC systems on a life-cycle basis. A techno-economic analysis framework based on commercially available products that evaluates the cost-effectiveness of DC systems is presented. The analysis is conducted for three commercial building types in two California climate zones and for various PV and battery storage capacities. Monte Carlo simulation is used to compute the payback period and lifecycle cost savings of DC versus AC distribution systems. A future-market scenario is also examined, which evaluates how future efficiency improvements in power converters and changes in electricity tariffs may affect cost savings. This analysis shows that DC systems can be cost-effective in all scenarios that include large capacities of battery storage and onsite solar, whereas for systems without storage, DC distribution is generally not cost-effective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Main Street Zero Energy Buildings: The Zero Energy Method in Concept and Practice: Preprint

Ongoing work at the National Renewable Energy Laboratory indicates that net-zero energy building (NZEB) status is both achievable and repeatable today. This paper presents a definition framework for classifying NZEBs and a real-life example that demonstrates how a large-scale office building can cost-effectively achieve net-zero energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗