Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contact pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

CO2 (dry ice) cleaning system

Tomco Equipment Company has participated in the dry ice (solid carbon dioxide, CO2) cleaning industry for over ten years as a pioneer in the manufacturer of high density, dry ice cleaning pellet production equipment. For over four years Tomco high density pelletizers have been available to the dry ice cleaning industry. Approximately one year ago Tomco introduced the DI-250, a new dry ice blast unit making Tomco a single source supplier for sublimable media, particle blast, cleaning systems. This new blast unit is an all pneumatic, single discharge hose device. It meters the insertion of 1/8 inch diameter (or smaller), high density, dry ice pellets into a high pressure, propellant gas stream. The dry ice and propellant streams are controlled and mixed from the blast cabinet. From there the mixture is transported to the nozzle where the pellets are accelerated to an appropriate blasting velocity. When directed to impact upon a target area, these dry ice pellets have sufficient energy to effectively remove most surface coatings through dry, abrasive contact. The meta-stable, dry ice pellets used for CO2 cleaning, while labeled 'high density,' are less dense than alternate, abrasive, particle blast media. In addition, after contacting the target surface, they return to their equilibrium condition: a superheated gas state. Most currently used grit blasting media are silicon dioxide based, which possess a sharp tetrahedral molecular structure. Silicon dioxide crystal structures will always produce smaller sharp-edged replicas of the original crystal upon fracture. Larger, softer dry ice pellets do not share the same sharp-edged crystalline structures as their non-sublimable counterparts when broken. In fact, upon contact with the target surface, dry ice pellets will plastically deform and break apart. As such, dry ice cleaning is less harmful to sensitive substrates, workers and the environment than chemical or abrasive cleaning systems. Dry ice cleaning system components include: a dry ice pellet supply, a non-reactive propellant gas source, a pellet and propellant metering device, and a media transport and acceleration hose and nozzle arrangement. Dry ice cleaning system operating parameters include: choice of propellant gas, its pressure and temperature, dry ice mass flow rate, dry ice pellet size and shape, and acceleration nozzle configuration. These parameters may be modified to fit different applications. The growth of the dry ice cleaning industry will depend upon timely data acquisition of the effects that independent changes in these parameters have on cleaning rates, with respect to different surface coating and substrate combinations. With this data, optimization of cleaning rates for particular applications will be possible. The analysis of the applicable range of modulation of these parameters, within system component mechanical constraints, has just begun.

Barnett, Donald M.↗

The evolution of seafloor venting from hydrate-sealed gas reservoirs

Here we use 3D seismic data to show that three rows of seafloor gas mounds can be traced downward to leak points that lie at the hydrate-gas contact within three individual dipping coarse-grained sand bodies in the Terrebonne Basin, Walker Ridge block 313, northern Gulf of Mexico. We predict the overpressure within the sand bodies by assuming that the gas pressure at the vent points equal the least principal stress. We interpret that free gas accumulates at the base of the hydrate stability zone, trapped by the overlying sand which has a high methane hydrate saturation. The free gas accumulates until the gas pressure at the base of the hydrate stability zone reaches the least principal stress in the overlying mudrock, whereupon hydraulic fractures form and fluids are vented to the surface. The warm rising fluids and perhaps localized exothermic formation of hydrate raise the local salinity and temperature. This process progressively shifts the base of the hydrate stability zone to shallower depths and dissociates the hydrate seal within the sand, which creates new leak points and results in the observed migration of the seafloor vents. Within the southwest corner of the Terrebonne Basin, this process has repeated multiple times within the Blue, Orange, and Green sands. Here this study shows how the hydrate stability zone can influence the location of fluid expulsion and in turn be affected by the warm, rising, saline fluids sealed by hydrate.

58 GEOSCIENCES↗

Insights into Designing an Efficient and Reliable Microwave-Assisted Methane Dehydroaromatization Process: Effect of Microwave Absorber on Catalyst Performance

Microwave-assisted methane dehydroaromatization has the potential to address challenges of traditional dehydroaromatization reactions. However, catalysts for microwave-enhanced reaction systems require effective coupling of fields with the catalyst to produce heat and reach reaction temperatures. Here, this work presents an in-depth understanding of the effect of the addition of silicon carbide as a microwave absorber on catalyst performance among other variables, the viability of the microwave reactor configuration, and insights into designing an effective and reliable microwave-based methane dehydroaromatization process. The effect of other parameters including temperature, weight hourly space velocity, role of microwave absorber, and methane concentration during microwave-assisted methane dehydroaromatization reaction are studied. Mo/ZSM-5 was found to suffer from low permittivity and nonuniform heating under microwave conditions. Mixing silicon carbide powder as a microwave absorber with the catalyst was found to provide more uniform heating. When assessing the catalytic performance of the mixture, it was found that higher methane partial pressures at 2000 cc/g cat .h and a temperature range of 500-600°C produced the highest amount of benzene. The formation of graphitic carbon on the spent catalyst increased with temperature, gas-solid contact period, and methane concentration, which resulted in higher methane conversion and benzene selectivity. The study indicates that under microwave heating the presence of localized carbon enhanced catalyst life by coupling with microwave energy, leading to localized heating, and improving benzene selectivity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concerning the origin of novae and U Geminorum stars

The dynamical stability of the contact component in a semi-detached binary system is investigated by a linear time dependent analysis. The boundary condition imposed on the photosphere by the Roche lobe is assumed to be one of constant pressure over the whole surface of the lobe, which is treated as being spherically symmetric. The eigenvalues of the linear equation of motion are evaluated for sequences of stellar envelope models under the constraint of this boundary condition. An extensive region in the Hertzprung-Russell diagram is found to be dynamically unstable. This region coincides almost precisely with that predicted by a previous quasi-static study. Time scales for the growth of the instability are also evaluated. Color observations of several novae and U Geminorum stars are discussed in an attempt to provide semi-empirical tests of the proposed theoretical model of the outbursts. In particular the track in the H-R diagram of the U Geminorum star, EM Cygni, is shown to be consistent with an outburst which is purely a temperature change at constant radius, as is demanded by the theory.

Bath, G. T.↗

Vibration isolation and pressure compensation apparatus for sensitive instrumentation

A system for attenuating the inherent vibration associated with a mechanical refrigeration unit employed to cryogenically cool sensitive instruments used in measuring chemical constituents of the atmosphere is described. A modular system including an instrument housing and a reaction bracket with a refrigerator unit floated there between comprise the instrumentation system. A pair of evacuated bellows that "float' refrigerator unit and provide pressure compensation at all levels of pressure from seal level to the vacuum of space. Vibration isolators and when needed provide additional vibration damping for the refrigerator unit. A flexible thermal strap (20 K) serves to provide essentially vibration free thermal contact between cold tip of the refrigerator unit and the instrument component mounted on the IDL mount. Another flexible strap (77 K) serves to provide vibration free thermal contact between the TDL mount thermal shroud and a thermal shroud disposed about the thermal shaft.

Averill, R. D.↗

Characterization of an electrically conductive proppant for fracture diagnostics

Fracture diagnosis with electromagnetic (EM) and electrical tools requires proppants with high electrical conductivity and mechanical strength. Lab measurements of the electrical and hydraulic conductivity of proppants are critical for selecting the best candidates. Such measurements greatly benefit simulations, field tests, and the ultimate application of such proppants in the field. To that end, a new lab protocol is developed for measuring the electrical and hydraulic conductivity of proppants. The lab setup, which mainly includes a resistivity core holder and a Hassler sleeve core holder, allows for simulation of realistic pressure and temperature conditions when making measurements. Petroleum coke (PC) is proposed as a candidate proppant because of its widespread availability and low cost. Lab measurements show that the effective electrical conductivity of pure PC in a model fracture is approximately 5000 S/m, under a closure stress greater than [Formula: see text] (4000 psi). When PC is mixed with sand, the effective electrical conductivity of the mixture decreases with an increasing weight percentage of sand. Although sand degrades the contact between PC particles, the electrical conductivity stays reasonably high (approximately 1700 S/m) when 50% sand is added. Hydraulic conductivity measurements show that when a fracture is propped with pure PC, the measured fracture conductivity is greater than [Formula: see text] ([Formula: see text]) (dimensionless fracture conductivity greater than 100 for a shale with [Formula: see text] or 100 nD permeability) under a confining pressure of [Formula: see text] (6000 psi). This means that a fracture propped with PC is infinitely conductive in a typical shale formation. When sand is added, the fracture’s hydraulic conductivity becomes even higher, which clearly shows PC’s ability of sustaining high stresses. The proposed protocol provides a robust and effective method that can be generalized for lab testing for other candidate proppants. The data presented clearly show that PC has the potential for field-scale applications in EM hydraulic fracture diagnostics.

Geochemistry & Geophysics↗

Development of Gas-Lubricated Pistons for Heavy Duty Diesel Engine Technology Program

Static testing of a segmented, gas-lubricated, piston-ring was accomplished. The ring utilizes high-pressure gas generated during the diesel cycle to energize a hydrostatic gas film between the piston and cylinder liner. The configuration was deficient in overall performance, because all segments of a ring set failed to form a fluid-film simultaneously, when exposed to internal preload. The difficulty was traced to the moment balance required to prevent the segments from overturning and contacting the cylinder walls. Some individual sectors formed a film and performed well in every respect including load capability to 6,000 N. These results produce optimism as to the ultimate feasibility of hydrostatic, gas-lubricated piston rings. In addition to test results, the principles of operation, and theoretical developments are presented. Breathable liner concepts are suggested for future consideration. In these configurations, solid hydrostatic pistons are coupled with flexible liners that elastically deform to form a gas-film under hydrostatic pressurization. Breathable liners afford the mechanical simplicity required for mass produced engines, and initial examination indicates satisfactory operation.

Shapiro, W.↗

Fractal Model for Drag Reduction on Multiscale Nonwetting Rough Surfaces

Rough surfaces in contact with a flow of fluid exhibit alternating no-slip and free shear boundary conditions at the solid–liquid and air–liquid interfaces, respectively, thereby potentially offering drag reduction benefits. The balance between the dynamic pressure in the flow and the restoring capillary pressure in the interasperity spaces determines the stability of the Cassie state of wettability and is a function of the relative extent of no-slip and free shear regions per unit surface area. In the present study, using a fractal representation of rough surface topography, an analytical model is developed to quantify the stability of the Cassie state of wettability as well as drag reduction and the friction factor for laminar flow in a rectangular channel between nonwetting multiscale rough surfaces. A systematic study is conducted to quantify the effects of fractal parameters of the surfaces and the flow Reynolds number on drag reduction and the friction factor. The studies are used to develop friction factor curves extending the classical Moody diagram to hydrophobic and superhydrophobic surfaces. On the basis of the studies, regime maps are derived for estimating the extent of drag reduction offered by hydrophobic and superhydrophobic surfaces, revealing that superhydrophobic surfaces do not always offer the best drag reduction performance. The application of the fractal model to practical topographies of nonwetting surfaces of copper, aluminum, and zinc oxide fabricated via electrodeposition and etching is also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

Investigations of lubricant rheology as applied to elastohydrodynamic lubrication

The pressure viscometer was modified to permit the measurement of viscosity at elevated pressures and shear stresses up to 5 x 10 to the 6th power N/sq m (720 psi). This shear stress is within a factor of three of the shear stress occurring in a sliding ehd point contact such as occurs in the ehd simulator. Viscosity data were taken on five lubricant samples, and it was found that viscous heating effects on the viscosity were predominant and not non-Newtonian behavior at the high shear stresses. The development of the infrared temperature measuring technique for the ehd simulator was completed, and temperature data for a set of operating conditions and one lubricant are reported. The numerical analysis of the behavior of nonlinear lubricants in the lubrication of rollers is reported.

Carlson, S.↗

Electrically Connecting to Pressure Vessels

Resilient conductive disk eliminates need for holes in vessel walls. Grounding disk made from wire and solder and sandwiched between electrical-component support and pressure-vessel wall. Emplaced in component support, disk squeezed to 66 percent of its thickness. Disk conforms to surfaces of support and vessel wall when support attached to wall with adhesive. Disk thus forms reliable electrical contact from support (and its electrical component) to wall.

Rossi, P. J.↗

Low-pressure, chemical vapor deposition polysilicon

The low-pressure chemical vapor deposition (LPCVD) of polycrystalline silicon was investigted. The physical system was described, as was the controlling process parameters and requirements for producing films for use as an integral portion of the solar cell contact system.

Gallagher, B. D.↗

Control of Flowing Liquid Films By Electrostatic Fields in Space

A novel type of lightweight space radiator has been proposed which employs internal electrostatic fields to stop coolant leaks from punctures caused by micrometeorites or space debris. Extensive calculations have indicated the feasibility of leak stoppage without film destabilization for both stationary and rotating designs. Solutions of the evolution equation for a liquid-metal film on an inclined plate, using lubrication theory for low Reynolds numbers, Karman-Pohlhausen quadratic velocity profiles for higher Reynolds numbers, and a direct numerical solution are shown. For verification an earth-based falling-film experiment on a precisely-vertical wall with controllable vacuum on either side of a small puncture is proposed. The pressure difference required to start and to stop the leak, in the presence and absence of a strong electric field, will be measured and compared with calculations. Various parameters, such as field strength, film Reynolds number, contact angle, and hole diameter will be examined. A theoretical analysis will be made of the case where the electrode is close enough to the film surface that the electric field equation and the surface dynamics equations are coupled. Preflight design calculations will be made in order to transfer the modified equipment to a flight experiment.

Bankoff, S. George↗

Guide for Hydrogen Hazards Analysis on Components and Systems

The physical and combustion properties of hydrogen give rise to hazards that must be considered when designing and operating a hydrogen system. One of the major concerns in the use of hydrogen is that of fire or detonation because of hydrogen's wide flammability range, low ignition energy, and flame speed. Other concerns include the contact and interaction of hydrogen with materials, such as the hydrogen embrittlement of materials and the formation of hydrogen hydrides. The low temperature of liquid and slush hydrogen bring other concerns related to material compatibility and pressure control; this is especially important when dissimilar, adjoining materials are involved. The potential hazards arising from these properties and design features necessitate a proper hydrogen hazards analysis before introducing a material, component, or system into hydrogen service. The objective of this guide is to describe the NASA Johnson Space Center White Sands Test Facility hydrogen hazards analysis method that should be performed before hydrogen is used in components and/or systems. The method is consistent with standard practices for analyzing hazards. It is recommended that this analysis be made before implementing a hydrogen component qualification procedure. A hydrogen hazards analysis is a useful tool for hydrogen-system designers, system and safety engineers, and facility managers. A hydrogen hazards analysis can identify problem areas before hydrogen is introduced into a system-preventing damage to hardware, delay or loss of mission or objective, and possible injury or loss of life.

Beeson, Harold↗

In-situ gloveport glove leak tester

The invention provides a system for detecting leaks in glovebox gloves, the system having a first seal within a glovebox aperture; a second seal contacting exterior surfaces of a glovebox, wherein the exterior surfaces define a periphery of the aperture; a first fluid supply for circumferentially expanding the first seal against center facing surfaces of the aperture to a first pressure; a second fluid supply for inflating the glove to a second pressure; and a pressure gauge for detecting a pressure decrease of the second pressure. Also provided is an in situ method for detecting leaks in glove box gloves, the method having the steps of applying a radially directed force to inside surfaces of cuffs of the gloves to hermetically seal the gloves from the exterior of the glovebox, thereby establishing a seal; inflating the gloves to a pressure; and monitoring the pressure for any decrease in pressure.

42 ENGINEERING↗

Catalytic production of 1,2,5,6-hexanetetrol from levoglucosenone

A method of making of 1,2,5,6-hexanetetrol (“tetrol”). The method includes the steps of contacting a reaction solution containing water as well as levoglucosenone, dihydrolevoglucosenone, and/or levoglucosanol, with a catalyst containing metal and acid functionalities, at temperature of from about 100° C. to about 175° C., and a hydrogen partial pressure of from about 1 bar to about 50 bar (about 0.1 MPa to about 5 MPa), and for a time wherein at least a portion of the reactant is converted into 1,2,5,6-hexanetetrol.

Krishna, Siddarth H.↗

Stretchable Photodiodes with Polymer-Engineered Semiconductor Nanowires for Wearable Photoplethysmography

Healthcare systems worldwide have been stressed to provide sufficient resources to serve the increasing and aging population in our society. The situation became more challenging at the time of pandemic. Technology advancement, especially the adoption of wearable health monitoring devices, has provided an important supplement to current clinical equipment. Most health monitoring devices are rigid, however, human tissues are soft. Such a difference has prohibited intimate contact between the two and jeopardized wearing comfortableness, which hurdles measurement accuracy especially during longtime usage. Here, in this work, we report a soft and stretchable photodiode that can conformally adhere onto the human body without any pressure and measure cardiovascular variables for an extended period with higher reliability than commercial devices. The photodiode used a composite light absorber consisting of an organic bulk heterojunction embedded into an elastic polymer matrix. It is discovered that the elastic polymer matrix not only improves the morphology of the bulk heterojunction for obtaining the desired mechanical properties but also alters its electronic band structure and improves the electrical properties that lead to a reduced dark current and enhanced photovoltage in the stretchable photodiode. The work has demonstrated high fidelity measurements and longtime monitoring of heat rate variability and oxygen saturation, potentially enabling next-generation wearable photoplethysmography devices for point-of-care diagnosis of cardiovascular diseases in a more accessible and affordable way.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗