Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings

California is a leader in automating demand response (DR) to promote low-cost, consistent, and predictable electric grid management tools. Over 250 commercial and industrial facilities in California participate in fully-automated programs providing over 60 MW of peak DR savings. This paper presents a summary of Open Automated DR (OpenADR) implementation by each of the investor-owned utilities in California. It provides a summary of participation, DR strategies and incentives. Commercial buildings can reduce peak demand from 5 to 15percent with an average of 13percent. Industrial facilities shed much higher loads. For buildings with multi-year savings we evaluate their load variability and shed variability. We provide a summary of control strategies deployed, along with costs to install automation. We report on how the electric DR control strategies perform over many years of events. We benchmark the peak demand of this sample of buildings against their past baselines to understand the differences in building performance over the years. This is done with peak demand intensities and load factors. The paper also describes the importance of these data in helping to understand possible techniques to reach net zero energy using peak day dynamic control capabilities in commercial buildings. We present an example in which the electric load shape changed as a result of a lighting retrofit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Office Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to our understanding of how homes use energy, and we cannot control what we do not understand. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, we have investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. The scope of this report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to ten end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. We conclude that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effectiveness of Residue and Tillage Management on Runoff Pollutant Reduction from Agricultural Areas

Highlights No-till and no-till residue systems were effective in reducing runoff particulate and total nutrients but increased dissolved nutrients. Maintaining >30% residue cover reduced most runoff constituents, irrespective of no-till or tillage. No-till-residue prevented runoff nutrient losses and benefitted farm revenue by avoiding tillage. Abstract. Reduced tillage management conservation practices (No-till and Reduced-till) are widely adopted in agriculture; however, understanding their overall effectiveness for water quality protection is challenging. A meta-analysis was conducted to understand and quantify the effectiveness of residue and tillage management on runoff, sediment, and nutrient losses from agricultural fields. Annual runoff and the associated sediment, and nutrient (nitrogen and phosphorus) loads were compiled from 60 peer reviewed research articles published across the United States and Canada. A total of 1575 site-years of data were categorized into tillage (<30% surface cover), no-tillage (<30% surface cover), tillage with residue (>30% surface cover), no-tillage with residue (>30% surface cover), and pasture management. No-tillage, no-tillage-residue, and tillage-residue managements were evaluated for their effectiveness in reducing runoff, nutrients, and sediment loads compared to tillage. Synthesized and surveyed corn yield data were used to evaluate the economic cost effectiveness of no-tillage-residue management with respect to tillage. Across the site years (1968-2019) studied, median runoff depth for no-tillage and no-tillage-residue were 84% and 70% greater than tillage and tillage-residue management, respectively. No-tillage-residue management had up to 86% less sediment losses than tillage systems, on average, for both >30% and <30% surface cover. No-tillage-residue management was most effective, with a positive performance effectiveness of 65% to 90% in controlling sediments, particulate, and total nutrient losses in runoff compared to tillage. Cost effectiveness analysis revealed the benefits of no-tillage-residue management in reducing nutrient loads and increasing net-farm revenue by avoiding tillage operational costs. Except for dissolved phosphorus, no-tillage-residue management cost effectiveness for sediments and nutrient loads ranged from negative $6 to negative $102 per every Mg or kg of load reduction, indicating it had both economic and environmental benefits compared to tillage management. Overall, these results indicate that over the long-term, no-tillage and tillage, combined with greater than 30% residue cover, can effectively reduce sediment and nutrient losses. This work highlights the importance of crop residues on the soil surface to reduce runoff losses, even in no-tillage systems. Keywords: Conservation tillage, No-tillage, Residue cover, Tillage, Water quality.

Agriculture↗

Stochastic DG Placement for Conservation Voltage Reduction Based on Multiple Replications Procedure

Conservation voltage reduction (CVR) and distributed-generation (DG) integration are popular strategies implemented by utilities to improve energy efficiency. This paper investigates the interactions between CVR and DG placement to minimize load consumption in distribution networks, while keeping the lowest voltage level within the predefined range. The optimal placement of DG units is formulated as a stochastic optimization problem considering the uncertainty of DG outputs and load consumptions. A sample average approximation algorithm-based technique is developed to solve the formulated problem effectively. A multiple replications procedure is developed to test the stability of the solution and calculate the confidence interval of the gap between the candidate solution and optimal solution. The proposed method has been applied to the IEEE 37-bus distribution test system with different scenarios. The numerical results indicate that the implementations of CVR and DG, if combined, can achieve significant energy savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear Multiobjective MPC-Based Optimal Operation of a High Consistency Refining System in Papermaking

As one of the most important unit in the papermaking industry, the high consistency (HC) refining system is confronted with challenges such as improving pulp quality, energy saving, and emissions reduction in its operation processes. Here in this correspondence, an optimal operation of HC refining system is presented using nonlinear multiobjective model predictive control strategies that aim at set-point tracking objective of pulp quality, economic objective, and specific energy (SE) consumption objective, respectively. First, a set of input and output data at different times are employed to construct the subprocess model of the state process model for the HC refining system, and then the Wiener-type model can be obtained through combining the mechanism model of Canadian Standard Freeness and the state process model that determines their structures based on Akaike information criterion. Second, the multiobjective optimization strategy that optimizes both the set-point tracking objective of pulp quality and SE consumption is proposed simultaneously, which uses NSGA-II approach to obtain the Pareto optimal set. Furthermore, targeting at the set-point tracking objective of pulp quality, economic objective, and SE consumption objective, the sequential quadratic programming method is utilized to produce the optimal predictive controllers. In conclusion, the simulation results demonstrate that the proposed methods can make the HC refining system provide a better performance of set-point tracking of pulp quality when these predictive controllers are employed. In addition, while the optimal predictive controllers orienting with comprehensive economic objective and SE consumption objective, it has been shown that they have significantly reduced the energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternate Methods in Refining the SLS Nozzle Plug Loads

Numerical analysis has shown that the SLS nozzle environmental barrier (nozzle plug) design is inadequate for the prelaunch condition, which consists of two dominant loads: 1) the main engines startup pressure and 2) an environmentally induced pressure. Efforts to reduce load conservatisms included a dynamic analysis which showed a 31% higher safety factor compared to the standard static analysis. The environmental load is typically approached with a deterministic method using the worst possible combinations of pressures and temperatures. An alternate probabilistic approach, utilizing the distributions of pressures and temperatures, resulted in a 54% reduction in the environmental pressure load. A Monte Carlo simulation of environmental load that used five years of historical pressure and temperature data supported the results of the probabilistic analysis, indicating the probabilistic load is reflective of a 3-sigma condition (1 in 370 probability). Utilizing the probabilistic load analysis eliminated excessive conservatisms and will prevent a future overdesign of the nozzle plug. Employing a similar probabilistic approach to other design and analysis activities can result in realistic yet adequately conservative solutions.

Burbank, Scott↗

Occupancy Simulation in Three Residential Research Houses

Three houses of similar floor plan are being compared for energy consumption. The first house is a typical builder house of 2400 ft2 (223 m2) in east Tennessee. The second house contains retrofits available to a home owner such as energy efficient appliances, windows and HVAC, as well as an insulated attic which contains HVAC duct work. The third house was built using optimum-value framing construction with photovoltaic modules and solar water heating. To consume energy researchers have set up appliances, lights, and plug loads to turn on and off automatically according to a schedule based on the Building America Research Benchmark Definition. As energy efficiency continues to be a focus for protecting the environment and conserving resources, experiments involving whole house energy consumption will be done. In these cases it is important to understand how to simulate occupancy so that data represents only house performance and not human behavior. The process for achieving automated occupancy simulation will be discussed. Data comparing the energy use of each house will be presented and it will be shown that the third house used 66% less and the second house used 36% less energy than the control house in 2010. The authors will discuss how energy prudent living habits can further reduce energy use in the third house by 23% over the average American family living in the same house.

Boudreaux, Philip R↗

Verification and Validation of EnergyPlus Phase Change Material Model for Opaque Wall Assemblies

Phase change materials (PCMs) represent a technology that may reduce peak loads and HVAC energy consumption in buildings. A few building energy simulation programs have the capability to simulate PCMs, but their accuracy has not been completely tested. This study shows the procedure used to verify and validate the PCM model in EnergyPlus using a similar approach as dictated by ASHRAE Standard 140, which consists of analytical verification, comparative testing, and empirical validation. This process was valuable, as two bugs were identified and fixed in the PCM model, and version 7.1 of EnergyPlus will have a validated PCM model. Preliminary results using whole-building energy analysis show that careful analysis should be done when designing PCMs in homes, as their thermal performance depends on several variables such as PCM properties and location in the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clustering and statistical analyses of air-conditioning intensity and use patterns in residential buildings

Energy conservation in residential buildings has gained increased attention due to its large portion of global energy use and potential of energy savings. Occupant behavior has been recognized as a key factor influencing the energy use and load diversity in buildings, therefore more realistic and accurate air-conditioning (AC) operating schedules are imperative for load estimation in equipment design and operation optimization. With the development of sensor technology, it became easier to access an increasing amount of heating/cooling data from thermal energy metering systems in residential buildings, which provides another possible way to understand building energy usage and occupant behaviors. However, except for cooling energy consumption benchmarking, there currently lacks effective and easy approaches to analyze AC usage and provide actionable insights for occupants. To fill this gap, this study proposes clustering analysis to identify AC use patterns of residential buildings, and develops new key performance indicators (KPIs) and data analytics to explore the AC operation characteristics using the long-term metered cooling energy use data, which is of great importance for inhabitants to understand their thermal energy use and save energy cost through adjustment of their AC use behavior. We demonstrate the proposed approaches in a residential district comprising 300 apartments, located in Zhengzhou, China. Main outcomes include: Representative AC use patterns are developed for three room types of residential buildings in the cold climate zone of China, which can be used as more realistic AC schedules to improve accuracy of energy simulation; Distributions of KPIs on household cooling energy usage are established, which can be used for household AC use intensity benchmarking and performance diagnoses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LABORATORY EVALUATION: PERFORMANCE OF A 10 RT GAS-ENGINE-DRIVEN HEAT PUMP (GHP)

Building air-conditioning (cooling) is the single largest use of electricity, driving increases in summer peak electric demand in much of the United States. Increases in peak load on the utility grid lead to high electricity prices, power quality problems, and grid system inefficiencies and even failures. Improved air-conditioning technology thus has the greatest potential impact on the electric grid compared to other technologies that use electricity. Thermally-activated systems, such as natural gas engine-driven heat pumps, can provide overall peak load reduction and electric grid relief for summer peak demand. This study describes the performance of a 10 refrigeration ton (RT) natural gas engine-driven heat pump rooftop unit in a controlled environment over a wide range of operating conditions in heating and cooling modes. Results showed gas COP exceeding the goal of 1.6 at 47 F (8.3 C) rating condition. Gas COP in cooling mode also exceeded the goal of 1.2 at 95 F (35 C) rating condition. Future work will investigate additional applications for gas engine-driven equipment, such as residential space conditioning.

03 NATURAL GAS↗

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identifying Sources of Volatile Organic Compounds and Aldehydes in a High Performance Building

The developers of the Paharpur Business Center (PBC) and Software Technology Incubator Park in New Delhi, India offer an environmentally sustainable building with a strong emphasis on energy conservation, waste minimization and superior indoor air quality (IAQ). To achieve the IAQ goal, the building utilizes a series of air cleaning technologies for treating the air entering the building. These technologies include an initial water wash followed by ultraviolet light treatment and biolfiltration using a greenhouse located on the roof and numerous plants distributed throughout the building. Even with the extensive treatment of makeup air and room air in the PBC, a recent study found that the concentrations of common volatile organic compounds and aldehydes appear to rise incrementally as the air passes through the building from the supply to the exhaust. This finding highlights the need to consider the minimization of chemical sources in buildings in combination with the use of advanced air cleaning technologies when seeking to achieve superior IAQ. The goal of this project was to identify potential source materials for indoor chemicals in the PBC. Samples of building materials, including wood paneling (polished and unpolished), drywall, and plastic from a hydroponic drum that was part of the air cleaning system, were collected from the building for testing. All materials were collected from the PBC building and shipped to the Lawrence Berkeley National Laboratory (LBNL) for testing. The materials were pre-conditioned for two different time periods before measuring material and chemical specific emission factors for a range of VOCs and Aldehydes. Of the six materials tested, we found that the highest emitter of formaldehyde was new plywood paneling. Although polish and paint contribute to some VOC emissions, the main influence of the polish was in altering the capacity of the surface to accumulate formaldehyde. Neither the new nor aged polish contributed significantly to formaldehyde emissions. The VOC emission stream (excluding formaldehyde) was composed of up to 18 different chemicals and the total VOC emissions ranged in magnitude from 7 mu g/m2/h (old wood with old polish) to>500 mu g/m2/h (painted drywall). The formaldehyde emissions from drywall and old wood with either new or old polish were ~;;15 mu g/m2/h while the new wood material emitted>100 mu g/m2/h. However, when the projected surface area of each material in the building was considered, the new wood, old wood and painted drywall material all contributed substantially to the indoor formaldehyde loading while the coatings contributed primarily to the VOCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data‐Driven Safety Risk Prediction of Lithium‐Ion Battery

Abstract Inevitable safety issues have pushed battery engineers to become more conservative in battery system design; however, battery‐involved accidents still frequently are reported in headlines. Identifying, understanding, and predicting safety risks have become priorities to further accelerate technology and industry development. However, diverse loading scenarios, significantly varied stress‐induced short circuit mechanisms, and highly coupled mechanical–electrochemical safety behaviors have remained grand challenges. Herein, the safety risk is termed as the probability of the mechanical triggering of an internal short circuit, to reflect the safety related behaviors of lithium‐ion batteries. Based on a mechanical model and experimental results, a sufficient dataset is generated consisting of strain states and their corresponding safety risks, covering both cylindrical and pouch cells, various states of charges, and loading conditions. Machine‐learning tools combined with the established finite element mechanical model are applied to predict the safety risks of the cells. The results achieve a high level of accuracy on the test data (the relative error of the average short circuit prediction deviation is less than 6.2%.). This work underpins the safety risk concept and highlights the promise of physics combined with data‐driven modeling methodology to predict the safety behaviors of energy storage systems.

Jia, Yikai↗