Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Explosion Calculations of SN1087

Explosion calculations of SNT1987A generate pictures of Rayleigh-Taylor fingers of radioactive Ni-56 which are boosted to velocities of several thousand km/s. From the KAO observations of the mid-IR iron lines, a picture of the iron in the ejecta emerges which is consistent with the "frothy iron fingers" having expanded to fill about 50% of the metal-rich volume of the ejecta. The ratio of the nickel line intensities yields a high ionization fraction of greater than or equal to 0.9 in the volume associated with the iron-group elements at day 415, before dust condenses in the ejecta. From the KAO observations of the dust's thermal emission, it is deduced that when the grains condense their infrared radiation is trapped, their apparent opacity is gray, and they have a surface area filling factor of about 50%. The dust emission from SN1987A is featureless: no 9.7 micrometer silicate feature, nor PAH features, nor dust emission features of any kind are seen at any time. The total dust opacity increases with time even though the surface area filling factor and the dust/gas ratio remain constant. This suggests that the dust forms along coherent structures which can maintain their radial line-of-sight opacities, i.e., along fat fingers. The coincidence of the filling factor of the dust and the filling factor of the iron strongly suggests that the dust condenses within the iron, and therefore the dust is iron-rich. It only takes approximately 4 x 10(exp -4) solar mass of dust for the ejecta to be optically thick out to approximately 100 micrometers; a lower limit of 4 x 10(exp -4) solar mass of condensed grains exists in the metal-rich volume, but much more dust could be present. The episode of dust formation started at about 530 days and proceeded rapidly, so that by 600 days 45% of the bolometric luminosity was being emitted in the IR; by 775 days, 86% of the bolometric luminosity was being reradiated by the dust. Measurements of the bolometric luminosity of SN1987A from 1000 - 1800 days are based on 10 micrometers and 20 micrometers photometry and rely on the suppositions that the IR emission is a greybody (proven to be true by the KAO observations at 615 and 775 days) and that the dust temperature drops to and remains at 150 K. The late time bolometric luminosity is stronger than that expected from the radioactive decay of Co-56, Co-57, Ti-44, and Na-22 and the possibility of an embedded compact object will be discussed.

Wooden, Diane H.↗

Meteoritic Constraints on Models of the Solar Nebula: The Abundances of Moderately Volatile Elements

The "moderately volatile" elements are those which condense (or evaporate) in the temperature range 650 - 1350 K, as a mix of material with solar abundances is cooled (or heated) tinder equilibrium conditions. Their relative abundances in chondritic meteorites are solar (or "cosmic", as defined by the composition of Cl meteorites) to within a factor of several, but vary within that range in a way that correlates remarkably well with condensation temperature, independent of chemical affinity. It has been argued that this correlation reflects a systematically selective process which favored the accretion of refractory material over volatile material from a cooling nebula. Wasson and Chou (Meteoritics 9, 69-94, 1974, and Wasson and co-authors in subsequent papers) suggested that condensation and settling of solids contemporaneously with the cooling and removal of nebular gas could produce the observed abundance patterns, but a quantitative model has been lacking. We show that the abundance patterns of the moderately volatile elements in chondritic meteorites can be produced, in some degree of quantitative detail, by models of the solar nebula that are designed to conform to observations of T Tauri stars and the global conservation laws. For example, even if the local surface density of the nebula is not decreasing, condensation and accretion of solids from radially inflowing gas in a cooling nebula can result in depletions of volatiles, relative to refractories, like those observed, The details of the calculated abundance patterns depend on (but are not especially sensitive to) model parameters, and can exhibit the variations that distinguish the meteorite classes. Thus it appears that nebula characteristics such as cooling rates, radial flow velocities, and particle accumulation rates can be quantitatively constrained by demanding that they conform to meteoritic data; and the models, in turn, can produce testable hypotheses regarding the time and location of the formation of the chondrite parent bodies and the planets.

Cassen, Patrick↗

Cloud Microphysics Budget in the Tropical Deep Convective Regime

Cloud microphysics budgets in the tropical deep convective regime are analyzed based on a 2-D cloud resolving simulation. The model is forced by the large-scale vertical velocity and zonal wind and large-scale horizontal advections derived from TOGA COARE for a 20-day period. The role of cloud microphysics is first examined by analyzing mass-weighted mean heat budget and column-integrated moisture budget. Hourly budgets show that local changes of mass-weighted mean temperature and column-integrated moisture are mainly determined by the residuals between vertical thermal advection and latent heat of condensation and between vertical moisture advection and condensation respectively. Thus, atmospheric thermodynamics depends on how cloud microphysical processes are parameterized. Cloud microphysics budgets are then analyzed for raining conditions. For cloud-vapor exchange between cloud system and its embedded environment, rainfall and evaporation of raindrop are compensated by the condensation and deposition of supersaturated vapor. Inside the cloud system, the condensation of supersaturated vapor balances conversion from cloud water to raindrop, snow, and graupel through collection and accretion processes. The deposition of supersaturated vapor balances conversion from cloud ice to snow through conversion and riming processes. The conversion and riming of cloud ice and the accretion of cloud water balance conversion from snow to graupel through accretion process. Finally, the collection of cloud water and the melting of graupel increase raindrop to compensate the loss of raindrop due to rainfall and the evaporation of raindrop.

Li, Xiao-Fan↗

Meteoritic Constraints on Models of the Solar Nebula: The Abundances of Moderately Volatile Elements

The "moderately volatile" elements are those which condense (or evaporate) in the temperature range 650 - 1350 K, as a mix of material with solar abundances is cooled (or heated) under equilibrium conditions. Their relative abundances in chondritic meteorites are solar (or "cosmic", as defined by tile composition of CI meteorites) to within a factor of several, but vary within that range in a way that correlates remarkably well with condensation temperature, independent of chemical affinity. It has been argued that this correlation reflects a systematically selective process which favored the accretion of refractory material over volatile material from a cooling nebula. Wasson and Chou suggested that condensation and settling of solids contemporaneously with the cooling and removal of nebular gas could produce tile observed abundance patterns, but a quantitative model has been lacking. We show that the abundance patterns of the moderately volatile elements in chondritic meteorites can be produced, in some degree of quantitative detail, by models of the solar nebula that are designed to conform to observations of T Tauri stars and the global conservation laws. For example, even if the local surface density of the nebula is not decreasing, condensation and accretion of solids from radially inflowing gas in a cooling nebula can result in depletions of volatiles, relative to refractories, like those observed. The details of the calculated abundance patterns depend on (but are not especially sensitive to) model parameters, and can exhibit the variations that distinguish the meteorite classes. Thus it appears that nebula characteristics Such as cooling rates, radial flow velocities, and particle accumulation rates can be quantitatively constrained by demanding that they conform to meteoritic data; and the models, in turn, can produce testable hypotheses regarding the time and location of the formation of the chondrite parent bodies and the planets.

Cassen, P.↗

Motion of Drops on Surfaces with Wettability Gradients

A liquid drop present on a solid surface can move because of a gradient in wettability along the surface, as manifested by a gradient in the contact angle. The contact angle at a given point on the contact line between a solid and a liquid in a gaseous medium is the angle between the tangent planes to the liquid and the solid surfaces at that point and is measured within the liquid side, by convention. The motion of the drop occurs in the direction of increasing wettability. The cause of the motion is the net force exerted on the drop by the solid surface because of the variation of the contact angle around the periphery. This force causes acceleration of an initially stationary drop, and leads to its motion in the direction of decreasing contact angle. The nature of the motion is determined by the balance between the motivating force and the resisting hydrodynamic force from the solid surface and the surrounding gaseous medium. A wettability gradient can be chemically induced as shown by Chaudhury and Whitesides who provided unambiguous experimental evidence that drops can move in such gradients. The phenomenon can be important in heat transfer applications in low gravity, such as when condensation occurs on a surface. Daniel et al have demonstrated that the velocity of a drop on a surface due to a wettability gradient in the presence of condensation can be more than two orders of magnitude larger than that observed in the absence of condensation. In the present research program, we have begun to study the motion of a drop in a wettability gradient systematically using a model system. Our initial efforts will be restricted to a system in which no condensation occurs. The experiments are performed as follows. First, a rectangular strip of approximate dimensions 10 x 20 mm is cut out of a silicon wafer. The strip is cleaned thoroughly and its surface is exposed to the vapor from an alkylchlorosilane for a period lasting between one and two minutes inside a desiccator. This is done using an approximate line source of the vapor in the form of a string soaked in the alkylchlorosilane. Ordinarily, many fluids, including water, wet the surface of silicon quite well. This means that the contact angle is small. But the silanized surface resists wetting, with contact angles that are as large as 100 degs. Therefore, a gradient of wettability is formed on the silicon surface. The region near the string is highly hydrophobic, and the contact angle decreases gradually toward a small value at the hydrophilic end away from this region. The change in wettability occurs over a distance of several mm. The strip is placed on a platform within a Plexiglas cell. Drops of a suitable liquid are introduced on top of the strip near the hydrophobic end. An optical system attached to a video camera is trained on the drop so that images of the moving drop can be captured on videotape for subsequent analysis. We have performed preliminary experiments with water as well as ethylene glycol drops. Results from these experiments will be presented in the poster. Future plans include the refinement of the experimental system so as to permit images to be recorded from the side as well as the top, and the conduct of a systematic study in which the drop size is varied over a good range. Experiments will be conducted with different fluids so as to obtain the largest possible range of suitably defined Reynolds and Capillary numbers. Also, an effort will be initiated on theoretical modeling of this motion. The challenges in the development of the theoretical description lie in the proper analysis of the region in the vicinity of the contact line, as well as in the free boundary nature of the problem. It is known that continuum models assuming the no slip condition all the way to the contact line fail by predicting that the stress on the solid surface becomes singular as the contact line is approached. One approach for dealing with this issue has been to relax the no-slip boundary condition using the Navier model. Molecular dynamics simulations of the contact line region show that for a non-polar liquid on a solid surface, the no-slip boundary condition is in fact incorrect near the contact line. Furthermore, the same simulations also show that the usual relationship between stress and the rate of deformation breaks down in the vicinity of the contact line. In developing continuum theoretical models of the system, we shall accommodate this knowledge to the extent possible.

Subramanian, R. Shankar↗

The Galileo Probe: How it Has Changed Our Understanding of Jupiter

The Galileo Mission to Jupiter, which arrived in December of 1995, provided the first study by an orbiter, and the first in-situ sampling via an entry probe, of an outer planet atmosphere. The rationale for an entry probe is that, even from an orbiter, remote sensing of the jovian atmosphere could not adequately retrieve the information desired. This paper provides a current summary of the most significant aspects of the data returned from the Galileo entry probe. As a result of the probe measurements, there has been a reassessment of our understanding of outer planet formation and evolution of the solar system. The primary scientific objective of the Galileo probe was to determine the composition of the jovian atmosphere, which from remote sensing remained either very uncertain, or completely unknown, with respect to several key elements. The probe found that the global He mass fraction is. significantly above the value reported from the Voyager Jupiter flybys but is slightly below the protosolar value, implying that there has been some settling of He to the deep jovian interior. The probe He measurements have also led to a reevaluation of the Voyager He mass fraction for Saturn, which is now determined to be much closer to that of Jupiter. The elements C, N, S, Ar, Kr, Xe were all found to have global abundances approximately 3 times their respective solar abundances. This result has raised a number of fundamental issues with regard to properties of planetesimals and the solar nebula at the time of giant planet formation. Ne, on the other hand, was found to be highly depleted, probably as the result of it being carried along with helium as helium settles towards the deep interior. The global abundance of O was not obtained by the probe because of the influence of local processes at the probe entry site (PES), processes which depleted condensible species, in this case H2O, well below condensation levels. Other condensible species, namely NH3 and H2S, were similarly affected but attained their deep equilibrium mixing ratios before the maximum depth sampled by the probe. Processes that might be capable of producing such effects on the condensibles are still under investigation. Measured isotopic ratios of noble gases and other heavy elements are solar, and (D + (Sup 3)He)/H is the same to within measurement uncertainties as in the local interstellar medium. No thick clouds were detected, and in particular no significant water cloud, but the PES location clearly affected the probe measurements of clouds. In fact, the probe data must be understood in the context of the location of the PES, which was within what is termed a 5 micron hot spot, a local clearing in the clouds that is bright near the 5 microns spectral region. The thermal structure at the PES was determined from approximately 1000 km above the 1 bar pressure level (10(exp -9 bars)) to 132 km 1 bar (22bars). The probe showed the atmosphere to have a generally sub-adiabatic temperature gradient (static stability) of = 0.1 K/km to as deep as the probe made measurements. In the upper atmosphere the probe derived a maximum positive vertical temperature gradient of approximately 5 K/km, and maximum temperature of = 900 K. The energy sources producing the warm upper atmosphere have yet to be completely identified. At first glance, Doppler tracking of the probe indicates that the long observed cloud level zonal winds extend to levels at least as deep as the probe made measurements. Zonal wind increases from = 80 m/s at pressures less than a bar to about 180 m/s near 5 bars, and remains approximately constant with depth thereafter. However, there is a question as to whether the winds measured from probe tracking are representative of the general wind field, or are considerably influenced by localized winds associated with the PES.

Young, Richard E.↗

Analysis of water from the Space Shuttle and Mir Space Station by ion chromatography and capillary electrophoresis

Drinking water and condensate samples collected from the US Space Shuttle and the Russian Mir Space Station are analyzed routinely at the NASA-Johnson Space Center as part of an ongoing effort to verify water quality and monitor the environment of the spacecraft. Water quality monitoring is particularly important for the Mir water supply because approximately half of the water consumed is recovered from humidity condensate. Drinking water on Shuttle is derived from the fuel cells. Because there is little equipment on board the spacecraft for monitoring the water quality, samples collected by the crew are transported to Earth on Shuttle or Soyuz vehicles, and analyzed exhaustively. As part of the test battery, anions and cations are measured by ion chromatography, and carboxylates and amines by capillary electrophoresis. Analytical data from Shuttle water samples collected before and after several missions, and Mir condensate and potable recovered water samples representing several recent missions are presented and discussed. Results show that Shuttle water is of distilled quality, and Mir recovered water contains various levels of minerals imparted during the recovery processes as designed. Organic ions are rarely detected in potable water samples, but were present in humidity condensate samples.

NASA Discipline Environmental Health↗

Rejoining and misrejoining of radiation-induced chromatin breaks. I. experiments with human lymphocytes

Fluorescence in situ hybridization with a composite probe for human chromosome 4 and a probe that stained all centromeres was used to study gamma-ray induced breakage, rejoining and misrejoining in prematurely condensed chromosomes in human lymphocytes. Dose-response curves for the induction of all types of aberrations in prematurely condensed human chromosomes 4 were determined immediately after irradiation and after 8 h postirradiation incubation. In addition, aberrations were measured after various incubation times from 0 to 18 h after a dose of 7 Gy. Unrejoined chromosome breaks were the most frequent type of aberration observed immediately after irradiation. Approximately 15% of total aberrations observed were chromosome exchanges. After 8 h postirradiation incubation, the frequency of breaks in prematurely condensed chromosomes declined to about 20% of the initial value, and chromosomal exchanges became the most frequent aberration. Results of metaphase analysis were similar to those for prematurely condensed chromosomes after 8 h incubation with the exception that a significantly lower frequency of fragments was observed. Symmetrical and asymmetrical interchanges were found at similar frequencies at all doses. No complex exchanges were observed in lymphocyte chromosomes immediately after exposure. They accounted for about 1% of total exchanges in metaphase chromosomes at doses <3 Gy and about 14% at 7 Gy. Incomplete exchanges amounted to approximately 15% of total exchanges at all doses. The kinetics of break rejoining was exponential, and the frequency of exchanges increased with kinetics similar to that observed for the rejoining of the breaks. This increase in the total exchanges as a function of the time between irradiation and fusion was due to a rapid increase in reciprocal interchanges, and a slower increase in complex exchanges; the frequency of incomplete exchanges increased initially, then decreased with prolonged incubation to the level observed in metaphase. It is concluded that the formation of each kind of chromosome aberrations follows different kinetics.

NASA Discipline Radiation Health↗

Miniature Heat Transport System for Spacecraft Thermal Control

Loop heat pipes (LHP) are efficient devices for heat transfer and use the basic principle of a closed evaporation-condensation cycle. The advantage of using a loop heat pipe over other conventional methods is that large quantities of heat can be transported through a small cross-sectional area over a considerable distance with no additional power input to the system. By using LHPs, it seems possible to meet the growing demand for high-power cooling devices. Although they are somewhat similar to conventional heat pipes, LHPs have a whole set of unique properties, such as low pressure drops and flexible lines between condenser and evaporator, that make them rather promising. LHPs are capable of providing a means of transporting heat over long distances with no input power other than the heat being transported because of the specially designed evaporator and the separation of liquid and vapor lines. For LHP design and fabrication, preliminary analysis on the basis of dimensionless criteria is necessary because of certain complicated phenomena that take place in the heat pipe. Modeling the performance of the LHP and miniaturizing its size are tasks and objectives of current research. In the course of h s work, the LHP and its components, including the evaporator (the most critical and complex part of the LHP), were modeled with the corresponding dimensionless groups also being investigated. Next, analysis of heat and mass transfer processes in the LHP, selection of the most weighted criteria from known dimensionless groups (thermal-fluid sciences), heat transfer rate limits, (heat pipe theory), and experimental ratios which are unique to a given heat pipe class are discussed. In the third part of the report, two-phase flow heat and mass transfer performances inside the LHP condenser are analyzed and calculated for Earth-normal gravity and microgravity conditions. On the basis of recent models and experimental databanks, an analysis for condensing two-phase flow regimes, pressure gradients, and local heat transfer coefficients using ammonia, propylene, and R134, are carried out.

Ochterbeck, Jay M.↗

Modeling of Heat and Mass Transfer in a TEC-Driven Lyophilizer

Dewatering of wet waste during space exploration missions is important for crew safety as it stabilizes the waste. It may also be used to recover water and serve as a preconditioning step for waste compaction. A thermoelectric cooler (TEC)-driven lyophilizer is under development at NASA Ames Research Center for this purpose. It has three major components: (i) an evaporator section where water vapor sublimes from the frozen waste, (ii) a condenser section where this water vapor deposits as ice, and (iii) a TEC section which serves as a heat pump to transfer heat from the condenser to the evaporator. This paper analyses the heat and mass transfer processes in the lyophilizer in an effort to understand the ice formation behavior in the condenser. The analysis is supported by experimental observations of ice formation patterns in two different condenser units.

Yuan, Zeng-Guang↗

Capillary pumped loop body heat exchanger

A capillary pumped loop for transferring heat from one body part to another body part, the capillary pumped loop comprising a capillary evaporator for vaporizing a liquid refrigerant by absorbing heat from a warm body part, a condenser for turning a vaporized refrigerant into a liquid by transferring heat from the vaporized liquid to a cool body part, a first tube section connecting an output port of the capillary evaporator to an input of the condenser, and a second tube section connecting an output of the condenser to an input port of the capillary evaporator. A wick may be provided within the condenser. A pump may be provided between the second tube section and the input port of the capillary evaporator. Additionally, an esternal heat source or heat sink may be utilized.

Swanson, Theodore D.↗

A Simple Mechanism for Fractionating Oxygen Isotopes in the Solar Nebula

Lightning in the Solar Nebula is caused by the tribo-electric charging of dust grains carried by massive turbulent flows and driven by the accretion energy in the disk: it has long been one agent assumed responsible for the formation of chondrules. The degree to which charge separation can occur is dependent upon a number of factors, including the concentration of radioactive sources and the total level of ionization in the nebula, and these factors determine the maximum energy likely to be released by a single bolt. While chondrule formation requires a massive discharge, even a small lightning bolt can vaporize grains in the ionized discharge channel. Experimental studies have shown that silica, iron silicate and iron oxide grains formed from a high voltage discharge in hydrogen rich gas containing some oxygen produces solids that are enriched in O-17 and O-18 relative to the composition of the starting gas. Vaporization of silicates produces SiO, metal and free oxygen atoms in each discharge and these species will immediately begin to recondense from the hot plasma. Freshly condensed grains are incrementally enriched in heavy oxygen while the gas is enriched in O-16. Repeated evaporation and condensation of silicates in continuously occurring lightning discharges will monotonically increase the fractionation of oxygen isotopes between the O-17 and O-18 rich dust and the O-16 rich gas. The first mass independently fractionated refractory oxide particles were produced in the lab following the condensation of a flowing gas mixture containing variable amounts of hydrogen, silane, pentacarbonyl iron and oxygen that passed through a high voltage discharge powered by a Tesla coil. While the exact chemical pathway is still uncertain, the most probable reaction mechanisms involve oxidation of the growing refractory clusters by O3, OH or O atoms. This model has some interesting consequences for chemical processes in the early solar nebula. Chemical fractionation of recondensed dust evaporated via lightning discharges should be strongly time dependent. At earlier times, the accretion rate is maximal, thus driving strong turbulence, energetic grain-grain collisions, tribo-electric charging and charge separation, leading to frequent, powerful lightning discharges. As the accretion rate diminishes, turbulence decreases and lightning discharges will become both less powerful and less frequent, thus decreasing the rate of dust-gas fractionation. The most rapid increase in the formation of O-16 poor dust will occur early in nebular history. Generation of fractionated dust should be distributed throughout the inner disk. Once condensed, grain dispersal would average out any significant isotopic anomalies within the inner disk.

Nuth, Joseph A., III↗

Transient Response to Rapid Cooling of a Stainless Steel Sodium Heat Pipe

Compact fission power systems are under consideration for use in long duration space exploration missions. Power demands on the order of 500 W, to 5 kW, will be required for up to 15 years of continuous service. One such small reactor design consists of a fast spectrum reactor cooled with an array of in-core alkali metal heat pipes coupled to thermoelectric or Stirling power conversion systems. Heat pipes advantageous attributes include a simplistic design, lack of moving parts, and well understood behavior. Concerns over reactor transients induced by heat pipe instability as a function of extreme thermal transients require experimental investigations. One particular concern is rapid cooling of the heat pipe condenser that would propagate to cool the evaporator. Rapid cooling of the reactor core beyond acceptable design limits could possibly induce unintended reactor control issues. This paper discusses a series of experimental demonstrations where a heat pipe operating at near prototypic conditions experienced rapid cooling of the condenser. The condenser section of a stainless steel sodium heat pipe was enclosed within a heat exchanger. The heat pipe - heat exchanger assembly was housed within a vacuum chamber held at a pressure of 50 Torr of helium. The heat pipe was brought to steady state operating conditions using graphite resistance heaters then cooled by a high flow of gaseous nitrogen through the heat exchanger. Subsequent thermal transient behavior was characterized by performing an energy balance using temperature, pressure and flow rate data obtained throughout the tests. Results indicate the degree of temperature change that results from a rapid cooling scenario will not significantly influence thermal stability of an operating heat pipe, even under extreme condenser cooling conditions.

Mireles, Omar R.↗

Fibrous-Ceramic/Aerogel Composite Insulating Tiles

Fibrous-ceramic/aerogel composite tiles have been invented to afford combinations of thermal-insulation and mechanical properties superior to those attainable by making tiles of fibrous ceramics alone or aerogels alone. These lightweight tiles can be tailored to a variety of applications that range from insulating cryogenic tanks to protecting spacecraft against re-entry heating. The advantages and disadvantages of fibrous ceramics and aerogels can be summarized as follows: Tiles made of ceramic fibers are known for mechanical strength, toughness, and machinability. Fibrous ceramic tiles are highly effective as thermal insulators in a vacuum. However, undesirably, the porosity of these materials makes them permeable by gases, so that in the presence of air or other gases, convection and gas-phase conduction contribute to the effective thermal conductivity of the tiles. Other disadvantages of the porosity and permeability of fibrous ceramic tiles arise because gases (e.g., water vapor or cryogenic gases) can condense in pores. This condensation contributes to weight, and in the case of cryogenic systems, the heat of condensation undesirably adds to the heat flowing to the objects that one seeks to keep cold. Moreover, there is a risk of explosion associated with vaporization of previously condensed gas upon reheating. Aerogels offer low permeability, low density, and low thermal conductivity, but are mechanically fragile. The basic idea of the present invention is to exploit the best features of fibrous ceramic tiles and aerogels. In a composite tile according to the invention, the fibrous ceramic serves as a matrix that mechanically supports the aerogel, while the aerogel serves as a low-conductivity, low-permeability filling that closes what would otherwise be the open pores of the fibrous ceramic. Because the aerogel eliminates or at least suppresses permeation by gas, gas-phase conduction, and convection, the thermal conductivity of such a composite even at normal atmospheric pressure is not much greater than that of the fibrous ceramic alone in a vacuum.

White, Susan M.↗

In-Service Monitoring of Steam Pipe Systems at High Temperatures

An effective, in-service health monitoring system is needed to track water condensation in real time through the walls of steam pipes. The system is required to measure the height of the condensed water from outside the pipe, while operating at temperatures that are as high as 250 C. The system needs to account for the effects of water flow and cavitation. In addition, it is desired that the system does not require perforating the pipes and thereby reducing the structural integrity. Generally, steam pipes are used as part of the district heating system carrying steam from central power stations under the streets to heat, cool, or supply power to high-rise buildings and businesses. This system uses ultrasonic waves in pulse-echo and acquires reflected signal data. Via autocorrelation, it determines the water height while eliminating the effect of noise and multiple reflections from the wall of the pipe. The system performs nondestructive monitoring through the walls of steam pipes, and automatically measures the height of condensed water while operating at the high-temperature conditions of 250 C. For this purpose, the ultrasonic pulse-echo method is used where the time-of-flight of the wave reflections inside the water are measured, and it is multiplied by the wave velocity to determine the height. The pulse-echo test consists of emitting ultrasonic wave pulses from a piezoelectric transducer and receiving the reflections from the top and bottom of the condensed water. A single transducer is used as a transmitter as well as the receiver of the ultrasonic waves. To obtain high resolution, a broadband transducer is used and the frequency can be in the range of 2.25 to 10 MHz, providing sharp pulses in the time domain allowing for higher resolution in identifying the individual reflections.

Bar-Cohen, Yoseph↗

Mineralogical Studies of a Highly O-17-Depleted and an O-17-Rich Presolar Grain from the Acfer 094 Meteorite

Silicate grains are the most abundant condensate around O-rich evolved stars, including red giants, supernovae (SNe) and binary systems. These grains have been identified in abundance in primitive meteorites and interplanetary dust particles [1,2]. Astronomical observations of the silicate spectroscopic features around circumstellar disks indicate that most silicates are amorphous olivine-like grains, though some sources show a large crystalline portion [3]. Fewer astronomical observations of SN and nova silicates exist, but amorphous Mg-rich grains predominate [4,5]. The laboratory analysis of presolar silicates by transmission electron microscopy (TEM) offers more details on the structure and chemistry of individual grains. These studies provide information on the physical and chemical conditions of the parent stellar atmosphere during grain condensation. Moreover, be-cause silicates are susceptible to secondary alteration, processing events succeeding condensation can be traced. Thus far, similar microstructures have been observed for silicates that condensed in SN outflows and in the envelopes of asymptotic giant branch (AGB) stars, but not as many of the comparatively rare SN grains have been analyzed. Here we examine the mineralogies of two presolar silicate grains having different origins.

Nguyen, A. N.↗

Radiative Impacts of Cloud Heterogeneity and Overlap in an Atmospheric General Circulation Model

The radiative impacts of introducing horizontal heterogeneity of layer cloud condensate, and vertical overlap of condensate and cloud fraction are examined with the aid of a new radiation package operating in the GEOS-5 Atmospheric General Circulation Model. The impacts are examined in terms of diagnostic top-of-the-atmosphere shortwave (SW) and longwave (LW) cloud radiative effect (CRE) calculations for a range of assumptions and parameter specifications about the overlap. The investigation is conducted for two distinct cloud schemes, the one that comes with the standard GEOS-5 distribution, and another which has been recently used experimentally for its enhanced GEOS-5 distribution, and another which has been recently used experimentally for its enhanced cloud microphysical capabilities; both are coupled to a cloud generator allowing arbitrary cloud overlap specification. We find that cloud overlap radiative impacts are significantly stronger for the operational cloud scheme for which a change of cloud fraction overlap from maximum-random to generalized results to global changes of SW and LW CRE of approximately 4 Watts per square meter, and zonal changes of up to approximately 10 Watts per square meter. This is because of fewer occurrences compared to the other scheme of large layer cloud fractions and of multi-layer situations with large numbers of atmospheric being simultaneously cloudy, conditions that make overlap details more important. The impact on CRE of the details of condensate distribution overlap is much weaker. Once generalized overlap is adopted, both cloud schemes are only modestly sensitive to the exact values of the overlap parameters. We also find that if one of the CRE components is overestimated and the other underestimated, both cannot be driven towards observed values by adjustments to cloud condensate heterogeneity and overlap alone.

Oreopoulos, L.↗

Temperature Oscillation in a Loop Heat Pipe with Gravity Assist

ATLAS Laser Thermal Control System (LTCS) thermal vacuum testing where the condenser-radiator was placed in a vertical position, it was found that the loop heat pipe (LHP) reservoir required much more control heater power than the analytical model had predicted. The required control heater power was also higher than the liquid subcooling entering the reservoir using the measured temperatures and the calculated mass flow rate based on steady state LHP operation. This presentation describes the investigation of the LHP behaviors under a gravity assist mode with a very cold radiator sink temperature and a large thermal mass attached to the evaporator. It is concluded that gravity caused the cold liquid to drop from the condenser-radiator to the reservoir, resulting in a rapid decrease of the reservoir temperature. When the reservoir temperature was increasing, a reverse flow occurred in the liquid line, carrying warm liquid to the condenser-radiator. Both events consumed the reservoir control heater power. The fall and rise of the reservoir temperature also caused the net heat input to the evaporator to vary due to the release and storage of the sensible heat of the thermal mass. The combination of these effects led to a persistent reservoir temperature oscillation and a repeated influx of cold liquid from the condenser. This was the root cause of the extraordinary high control heater power requirement in the LTCS TV test. Without gravity assist, such a persistent temperature oscillation will not be present.

000↗