Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compressed air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Analysis of Volatile Compounds from CO2 Removal Systems

One of the primary concerns when designing CO2 scrubber systems that will be integrated with a Sabatier reactor to produce water and methane is the amount of water released from the scrubber. Because the gas stream entering a Sabatier reactor must be compressed, water entering the reactor can condense and compromise the integrity of the system, thus rendering its valuable conversion capability useless. When the Johnson Space Center Environmental Chemistry Laboratory was tasked to develop an assay to quantify the water concentration in air samples from CO2 scrubbers, additional testing was also performed to see if any other compounds were being concentrated on the scrubbers. It was thought that the efficiency of the scrubber systems could be quantified by comparing the differences in samples from the ambient air on the International Space Station (ISS) to the exit gas of the scrubber. As this analysis was carried out, it became evident that the concentrations of certain volatile compounds were higher in the samples from the scrubbers than they were in nominal environmental samples. This meant these compounds were being retained and concentrated on the scrubber beds. Based on this finding, concerns were raised about their potential for these compounds to poison the Sabatier reactor. Further investigation was required to identify these compounds due to their high concentrations and unique matrix of the CO2 scrubber exhaust. This paper describes these events as well as the process that was developed to identify the volatile compounds that increased. An examination of how much the certain compounds can be concentrated by the scrubber systems is also included.

Volatiles↗

Analysis of Volatile Compounds From CO2 Removal Systems

One of the primary concerns when designing CO2 scrubber systems that will be integrated with a Sabatier reactor to produce water and methane is the amount of water released from the scrubber. Because the gas stream entering a Sabatier reactor must be compressed, water entering the reactor can condense and compromise the integrity of the system, thus rendering its valuable conversion capability useless. When the Johnson Space Center Environmental Chemistry Laboratory was tasked to develop an assay to quantify the water concentration in air samples from CO2 scrubbers, additional testing was also performed to see if any other compounds were being concentrated on the scrubbers. It was thought that the efficiency of the scrubber systems could be quantified by comparing the differences in samples from the ambient air on the International Space Station (ISS) to the exit gas of the scrubber. As this analysis was carried out, it became evident that the concentrations of certain volatile compounds were higher in the samples from the scrubbers than they were in nominal environmental samples. This meant these compounds were being retained and concentrated on the scrubber beds. Based on this finding, concerns were raised about their potential for these compounds to poison the Sabatier reactor. Further investigation was required to identify these compounds due to their high concentrations and unique matrix of the CO2 scrubber exhaust. This paper describes these events as well as the process that was developed to identify the volatile compounds that increased. An examination of how much the certain compounds can be concentrated by the scrubber systems is also included.

Volatiles↗

Modeling and Simulation of Radiative Compressible Flows in Aerodynamic Heating Arc-Jet Facility

Numerical simulations of an arc heated flow inside NASA's 20 [MW] Aerodynamics heating facility (AHF) are performed in order to investigate the three-dimensional swirling flow and the current distribution inside the wind tunnel. The plasma is considered in Local Thermodynamics Equilibrium(LTE) and is composed of Air-Argon gas mixture. The governing equations are the Navier-Stokes equations that include source terms corresponding to Joule heating and radiative cooling. The former is obtained by solving an electric potential equation, while the latter is calculated using an innovative massively parallel ray-tracing algorithm. The fully coupled system is closed by the thermodynamics relations and transport properties which are obtained from Chapman-Enskog method. A novel strategy was developed in order to enable the flow solver and the radiation calculation to be preformed independently and simultaneously using a different number of processors. Drastic reduction in the computational cost was achieved using this strategy. Details on the numerical methods used for space discretization, time integration and ray-tracing algorithm will be presented. The effect of the radiative cooling on the dynamics of the flow will be investigated. The complete set of equations were implemented within the COOLFluiD Framework. Fig. 1 shows the geometry of the Anode and part of the constrictor of the Aerodynamics heating facility (AHF). Fig. 2 shows the velocity field distribution along (x-y) plane and the streamline in (z-y) plane.

Pasma flows↗

Orientation and temperature dependence of some mechanical properties of the single-crystal nickel-base superalloy Rene N4. II - Low cycle fatigue behavior

The low cycle fatigue (LCF) properties of a single-crystal nickel-base superalloy Rene N4, have been examined at 760 and 980 C in air. Specimens having crystallographic orientations near the 001, 011, -111, 023, -236, and -145 lines were tested in fully reversed, total-strain-controlled LCF tests at a frequency of 0.1 Hz. At 760 C, this alloy exhibited orientation dependent tension-compression anisotropies of yielding which continued to failure. Also at 760 C, orientations exhibiting predominately single slip exhibited serrated yielding for many cycles. At 980 C, orientation dependencies of yielding behavior were smaller. In spite of the tension-compression anisotropies, cyclic stress range-strain range behavior was not strongly orientation dependent for either test temperature. Fatigue life on a total strain range basis was highly orientation dependent at 760 and 980 C and was related chiefly to elastic modulus, low modulus orientations having longer lives. Stage I crack growth on 111 planes was dominant at 760 C, while Stage II crack growth occurred at 980 C. Crack initiation generally occurred at near-surface micropores, but occasionally at oxidation spikes in the 980 C tests.

Gabb, T. P.↗

An investigation of a wall-injected scramjet using a shock tunnel

Experimental results are presented for several wall-injected, constant-area scramjet experiments, performed in the T4 free-piston-driven shock tunnel. Stagnation enthalpies range from 5.7 to 10.1 MJ/kg, corresponding to flight Mach numbers of Mach 9.7 to Mach 13. Hydrogen fuel is injected from the rear of a step into a supersonic air stream, with combustion-chamber Mach numbers of 3.6 and 4.4, and static pressures of 40 kPa. The experimental results are compared to numerical predictions obtained from a two-dimensional, parabolic Navier-Stokes code, which modeled turbulence with a compressibility modified k-epsilon model, and used multi-reaction, finite-rate chemistry. The numerical and experimental results show reasonable agreement and indicate that the scramjet flows studied are predominantly mixing limited.

Brescianini, C. P.↗

High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage factor make these semiconducting oxide films promising candidates for the active strain elements in high temperature thin film strain gages, particularly in applications where static strain measurement is desired.

Gregory, Otto J.↗

Single-Stage, 3.4:1-Pressure-Ratio Aspirated Fan Developed and Demonstrated

Researchers are constantly pursuing technologies that will increase the performance of gas turbine engines. The aspirated compressor concept discussed here would allow the compression system to perform its task with about one-half of the compressor blades. To accomplish this, the researchers applied boundary layer control to the blades, casing, and hub. This method of boundary layer control consisted of removing small amounts of air from the main flow path at critical areas of the compressor. This bleed air could be used by other systems such as engine cooling or could be re-injected into lower pressure areas that require air for enhanced performance. This effort was initiated by the Massachusetts Institute of Technology (MIT) in response to a solicitation from the Defense Advanced Research Projects Agency (DARPA) who sought to advance research in flow control technology. The NASA Glenn Research Center partnered with MIT (principal investigator), Honeywell Aircraft Engines (cycle analysis, structural analysis, and mechanical design), and Pratt & Whitney (cycle analysis and aero-analysis) to conceptualize, design, analyze, build, and test the aspirated fan stage. The aero-design and aero-analysis of this fan stage were jointly executed by MIT and Glenn to minimize the amount of bleed flow needed and to maintain the highest efficiency possible (ref. 1). Mechanical design issues were complicated by the need to have a shrouded rotor with hollow blades, with rotor stress levels beyond the capabilities of titanium. The high stress issues were addressed by designing a shroud that was filament wound with a carbon fiber/epoxy matrix, resulting in an assembly that was strong enough to handle the high stresses. Both the rotor (preceding photographs) and stator (following photograph) were fabricated in two halves and then bolted together at the hub and tip, permitting the bleed passages to be machined into each half before assembly.

Braunscheidel, Edward P.↗

Ultrafast High Accuracy PCRTM_SOLAR Model for Cloudy Atmosphere

An ultrafast high accuracy PCRTM_SOLAR model is developed based on PCA compression and principal component-based radiative transfer model (PCRTM). A fast algorithm for simulation of multi-scattering properties of cloud and/or aerosols is integrated into the fast infrared PCRTM. We completed radiance simulation and training for instruments, such as IASI, AIRS, CrIS, NASTI and SHIS, under diverse conditions. The new model is 5 orders faster than 52-stream DISORT with very high accuracy for cloudy sky radiative transfer simulation. It is suitable for hyperspectral remote data assimilation and cloudy sky retrievals.

Yang, Qiguang↗

Low-GWP Refrigerants Status and Outlook

Refrigeration - including air conditioning (AC) – contributes substantially to the modern life of the 21st century and its economy. The food cold chain, air conditioning, healthcare and energy are examples of sectors for which refrigeration is indispensable. About 5 billion refrigeration systems – of different types and sizes– operate worldwide in different applications [1]. The dominant share of equipment providing refrigeration operate on the vapor-compression-cycle principle and use fluorocarbon refrigerants. Concerns about the environmental safety have become the driving force for refrigerant changes within the last 35 years. The phased-out schedule of stratospheric-ozone-depleting fluids was first formulated by the Montreal Protocol (MP) in 1987 and was made more stringent during the follow-up international meetings [2]. The affected chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants were largely replaced by hydrofluorocarbons (HFCs).The 2016 Kigali Amendment to the MP [3] responses to the concerns about the Earth climate change. The refrigeration and AC sectors are attributed with about 7.8 % of global greenhouse gas emissions [4]. This contribution comes in the form of direct effect, which is related to refrigerant emissions from refrigeration systems (37 %), and in the form of indirect effect, which is related to CO2 emissions from fossil fuel power plants producing electricity to power refrigeration systems (63 %) [4]. The Kigali Amendment aims at reducing the direct effect. The effect a given molecule has on the climate change is quantified in a simplified manner by its Global Warming Potential (GWP), a relative index referencing the effect produced to that of the same mass of carbon dioxide released to the atmosphere. By definition, GWP of carbon dioxide is equal to one.While HFC refrigerants have on average a lower GWP than the CFCs and HCFCs they replaced, they are still potent greenhouse gases (GHGs). The Kigali Amendment phases down the use of HFCs by imposing a schedule for reducing a weighted GWP value to be implemented by a country through the year 2047 (Figure 1). It provides four paths depending on the country location and category assigned in the MP, and also prescribes a method for establishing the baseline consumption used for calculating GWP reductions. For developing countries, it is expected to bring the weighed GWP across all refrigeration applications down to about 300 from the baseline value of about 2000. The implementation of Kigali Amendment aims at reducing the future warming due to HFCs from the range of 0.3 °C to 0.5 °C to less than 0.1 °C [5]. While this reduction may seem to be small, it must be viewed in the context of the 2015 Paris Agreement [6], which calls for holding global warming to well below 2 °C and pursuing to limit global warming to 1.5 °C relative to pre-industrial levels [6]. Considering that average global temperatures reached 1 °C above pre-industrial levels for the first time in 2015 [7], the Earth is already within 1 °C of the “2 °C limit”.The low-GWP requirement narrows the pool of fluids that can be considered for application as a refrigerant [8]. This Informatory Note discusses low-GWP refrigerant options for major applications and presents their selection merits.

Yana Motta, Samuel↗

Hydrophobic, Thermal Shock-and-Corrosion-Resistant XSBR Latex-Modified Lightweight Class G Cement Composites in Geothermal Well Energy Storage Systems

Energy losses can be significantly reduced if thermally insulating cement is used for energy storage and recovery. The thermal conductivity (TC) of the currently used cement is between 1 and 1.2 W/mK. In this study we assessed the ability of polystyrene (PS)–polybutadiene (PB)–polyacrylic acid (PAA) terpolymer (cross-linked styrene–butadiene rubber, XSBR) latex to improve thermal insulating properties and thermal shock (TS) resistance of class G ordinary Portland cement (OPC) and fly ash cenosphere (FCSs) composites in the temperature range of 100–175 °C. The composites autoclaved at 100 °C were subjected to three cycles, one cycle: 175 °C heat → 25 °C water quenching). In hydrothermal and thermal (TS) environments at elevated temperatures in cement slurries the XSBR latex formed acrylic calcium complexes through acid–base reactions, and the number of such complexes increased at higher temperatures due to the XSBR degradation with formation of additional acrylic groups. As a result, these complexes offered the following five advanced properties to the OPC-based composites: (1) enhanced hydrophobicity; (2) decreased water-fillable porosity; (3) reduced TC for water-saturated composites; (4) minimized loss of compressive strength, Young’s modulus, and compressive fracture toughness after TS; and (5) abated pozzolanic activity of FCSs, which allowed FCSs to persist as thermal insulators under strongly alkaline conditions of cement slurries. Additionally, XSBR-modified slurries possessed improved workability and decreased slurry density due to the air-entraining effect of latex, which resulted in further improvement of thermal insulation performance of the modified composites.

15 GEOTHERMAL ENERGY↗

Crippling Strength of Axially Loaded Rods

A new empirical formula was developed that holds good for any length and any material of a rod, and agrees well with the results of extensive strength tests. To facilitate calculations, three tables are included, giving the crippling load for solid and hollow sectioned wooden rods of different thickness and length, as well as for steel tubes manufactured according to the standards of Army Air Services Inspection. Further, a graphical method of calculation of the breaking load is derived in which a single curve is employed for determination of the allowable fiber stress. Finally, the theory is discussed of the elastic curve for a rod subject to compression, according to which no deflection occurs, and the apparent contradiction of this conclusion by test results is attributed to the fact that the rods under test are not perfectly straight, or that the wall thickness and the material are not uniform. Under the assumption of an eccentric rod having a slight initial bend according to a sine curve, a simple formula for the deflection is derived, which shows a surprising agreement with test results. From this a further formula is derived for the determination of the allowable load on an eccentric rod. The resulting relations are made clearer by means of a graphical representation of the relation of the moments of the outer and inner forces to the deflection.

Natalis, FR↗

Hypersonic Navier-Stokes Comparisons to Orbiter Flight Data

During the STS-119 flight of Space Shuttle Discovery, two sets of surface temperature measurements were made. Under the HYTHIRM program3 quantitative thermal images of the windward side of the Orbiter with a were taken. In addition, the Boundary Layer Transition Flight Experiment 4 made thermocouple measurements at discrete locations on the Orbiter wind side. Most of these measurements were made downstream of a surface protuberance designed to trip the boundary layer to turbulent flow. In this paper, we use the US3D computational fluid dynamics code to simulate the Orbiter flow field at conditions corresponding to the STS-119 re-entry. We employ a standard two-temperature, five-species finite-rate model for high-temperature air, and the surface catalysis model of Stewart.1 This work is similar to the analysis of Wood et al . 2 except that we use a different approach for modeling turbulent flow. We use the one-equation Spalart-Allmaras turbulence model8 with compressibility corrections 9 and an approach for tripping the boundary layer at discrete locations. In general, the comparison between the simulations and flight data is remarkably good

Candler, Graham V.↗

Spatiotemporal Adaptive Passive Direct Air Capture

Carbon Collect Inc., along with Arizona State University, the Electric Power Research Institute (EPRI), PM Group, and Trimeric Corporation, completed an initial design of a commercial-scale, passive direct air capture (DAC) system termed “carbon trees” that will capture, separate, and store at least 100,000 tonnes/year of carbon dioxide (CO2) from air (net basis). Passive DAC is unique among DAC technologies in that passive air delivery by wind avoids the energy penalty of forced convection. Carbon Collect Inc.’s sorbent-agnostic approach offers the flexibility to choose sorbents for a wide range of climates. A combination of steam, low-grade heat, and vacuum releases the CO2 from the sorbent, which is extracted from the chamber and purified and compressed for geological storage. A commercial carbon tree forest combines the output of several thousand trees for compression and purification with high heat and energy integration. The project team prepared an initial engineering design package for each of three geographically diverse host sites throughout the United States to better understand the effect of local/regional ambient conditions on DAC system performance and project costs. A techno-economic analysis, life cycle analysis, business case analysis, and an environmental, health, and safety risks assessment were also completed for each of the three geographically diverse host sites.

14 SOLAR ENERGY↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compression-ignition engine tests of several fuels

The tests reported in this paper were made to devise simple engine tests which would rate fuels as to their comparative value and their suitability for the operating conditions of the individual engine on which the tests are made. Three commercial fuels were used in two test engines having combustion chambers with and without effective air flow. Strictly comparative performance tests gave almost identical results for the three fuels. Analysis of indicator cards allowed a differentiation between fuels on a basis of rates of combustion. The same comparative ratings were obtained by determining the consistent operating range of injection advance angle for the three fuels. The difference in fuels is more pronounced in a quiescent combustion chamber than in one with high-velocity air flow. A fuel is considered suitable for the operating conditions of an engine with a quiescent combustion chamber if it permits the injection of the fuel to be advanced beyond the optimum without exceeding allowable knock or allowable maximum cylinder pressures.

Spanogle, J A↗

Flow in a discrete slotted nozzle with massive injection

An experimental investigation has been conducted to determine the effect of massive wall injection on the flow characteristics in a slotted nozzle. Some of the experiments were performed on a water table with a slotted-nozzle test section. This has 45 deg and 15 deg half angles of convergence and divergence, respectively, throat radius of 2.5 inches, and throat width of 3 inches. The hydraulic analogy was employed to qualitatively extend the results to a compressible gas flow through the nozzle. Experimental results from the water table include contours of constant Froude and Mach number with and without injection. Photographic results are also presented for the injection through slots of CO2 and Freon-12 into a main-stream air flow in a convergent-divergent nozzle in a wind tunnel. Schlieren photographs were used to visualize the flow, and qualititative agreement between the results from the gas tunnel and water table is good.

Perkins, H. C.↗

A Phenomenological Thermal Spray Wall Interaction Modeling Framework Applied to a High Temperature Ignition Assistant Device

Airborne compression ignition engines must operate with reliable ignition systems to achieve proper ignition at every cycle, particularly at high altitudes. Glow-plug-based ignition-assistant (IA) devices can provide the necessary energy to preheat the fuel and ensure ignitability of the fuel-air mixture. Ignitability of liquid sprays can be facilitated via direct impingement onto the hot IA surface, however this comes with adverse effects on the IA durability. Therefore, optimizing an IA’s design requires detailed understanding of the physics of fuel spray impingement of superheated surfaces. While spray impingement on relatively low wall temperatures has been extensively studied and appropriate numerical models have been proposed through the years, fundamental understanding of high-speed liquid spray impingement on superheated walls is still elusive. This work aims to formulate a phenomenological thermal spray-wall interaction framework for modeling the film-boiling-induced heat transfer, atomization, and dispersion of fuel spray droplets impinging onto a superheated IA device. A qualitative comparison of the new phenomenological model is performed against optical experiments from the literature of an F-24 fuel spray injected onto an IA device located 12 mm away from the injector tip. The temperature of the IA was set at 1400 K. The fuel injection pressure was 400 bar, while the ambient gas pressure and temperature were 30 bar and 800 K, respectively. The performance of the phenomenological model is evaluated in comparison with two other state-of-art models from the literature. A qualitative analysis of the different spray and fuel-air mixture characteristics is performed to outline the differences in the predictions offered by the new phenomenological model and the two state-of-art spray-wall interaction models.

droplet dispersion↗

CROCUS Air Quality Data at Argonne National Laboratory Prairie Site

The AQT (Vaisala AQT530) instrument provides observations on meteorological conditions, including particulate matter (PM2.5, PM10), gas species concentrations (NO, NO2, O3, CO), and environment temperature and moisture. These measurements are critical for understanding air quality. These measurements are useful for understanding changes in aerosol properties, air quality research, and comparing to model experiments especially in urban environments. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a prairie field site at Argonne National Laboratory in Lemont, Illinois. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. Each file contains one day's worth of data (24 hours, starting at 0000 UTC). The data is aggregated into daily frequency to make it easier to process multiple days, and compress the higher-resolution fields. File naming convention includes the project (CROCUS), location (atmos), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗