Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Financial Analysis of the 2019 Glen Canyon Dam Bug Flow Experiment

This report was prepared by Argonne National Laboratory (Argonne) in support of a financial analysis of the Glen Canyon Dam (GCD) flow experiment that was intended to support downstream macroinvertebrate production that are a primary food supply for fishes in the Colorado River. Also known as “bug flow” experiments, these experimental water releases were conducted on the weekends and holidays from the beginnings of May 2019 through the end of August 2019. This analysis was funded by the Colorado River Storage Project (CRSP) Office of the U.S. Department of Energy’s Western Area Power Administration (WAPA). CRSP markets electricity produced by hydroelectric facilities collectively known as the Salt Lake City Area Integrated Projects including dams equipped for power generation on the Colorado, Green, Gunnison, and Rio Grande Rivers and on Plateau Creek in the states of Arizona, Colorado, New Mexico, Utah, and Wyoming. Staff members in Argonne’s Energy Systems Division prepared this technical memorandum with assistance from WAPA’s CRSP and Energy Marketing and Management Offices (EMMO).

13 HYDRO ENERGY↗

Development of Ionic Liquid-Additized, GF-5/6 Compatible Low-Viscosity Oils for Automotive Engine and Rear Axle Lubrication for 4% Improved Fuel Economy

This joint project among ORNL, GM, and DRO successfully developed ionic liquid-additized low viscosity lubricants, SAE 0W-12 and 70W-80, for both IC engine and rear axle lubrication, respectively, and demonstrated combined vehicle fuel economy improvement (FEI). Phosphonium-alkylphosphate ILs have been found to be the most effective among the candidates in protecting surface damage from both sliding wear and rolling contact fatigue, and optimal IL concentrations have been determined. The IL’s impact on three-way catalyst seems to be significantly less adverse than the conventional ZDDP. Oil formulations were optimized for both energy efficiency and wear protection. Tribological bench testing of the IL-additized low-viscosity oils showed at least 40% lower boundary friction, more than 60% lower elastohydrodynamic friction, and greater than 50% less wear compared with commercial baselines. IL-additized lubricants have demonstrated FEI by 9.9% in engine dynamometer tests under extreme conditions and 6.9% increased power output in gear rig tests. Prototype IL-additized engine oil and rear axle fluid exhibited combined FEI of 1.39% and 3.24% benchmarked against the state-of-the-art baselines in vehicle testing of fresh oils under the Federal Test Procedure (FTP) city cycle and Highway Fuel Economy Driving Schedule (HWFET), respectively. Used oil analysis suggested that the IL-additized low-viscosity oils produced less wear than the commercial baselines. The gained fundamental understanding and demonstrated FEI in this work pave the way for future development and implementation of the ionic liquid technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Acoustic Sensing (DAS) Seismic Monitoring of CO 2 Injected for Enhanced Oil Recovery in Northern Michigan

As part of the Midwest Regional Carbon Sequestration Partnership (MRCSP) Phase III project, a monitoring study was conducted to assess the effectiveness of DAS (Distributed Acoustic Sensing) -based VSP (Vertical Seismic Profiling) technology for delineating CO 2 injected into the Silurian-age pinnacle reefs in northern Michigan, the host rocks for the MRCSP Phase III demonstration project. The DAS VSP study was conducted in the Chester 16 reef, one of several reefs in Otsego County Michigan that is operated by Core Energy, LLC, of Traverse City, Michigan.

47 OTHER INSTRUMENTATION↗

Distributed Solar Adoption in Orlando: A Household-Level Model for Distribution Resource Planning

Potential for rooftop solar in Florida is massive (47% of retail sales, 3rd overall nationally), yet adoption lags (12th nationally). A 2018 Florida Public Service Commission ruling authorizing solar third-party ownership (leasing) has substantially increased attention on distributed solar in the state. The city of Orlando has committed to a 100% clean-energy target by 2050 and deployment of solar and storage are expected to contribute significantly to reaching the goal. Deployment of customer-adopted solar, unlike utility-procured solar, is uncertain, but known to be spatially correlated with demographic factors and existing adoption. We develop a new method to adapt NREL's dGen model in order to represent building-level agents in adoption forecasts for the Orlando Utility Commission (OUC) service territory. Using the agent-based model we develop projections of solar adoption, subject to scenarios varying future solar costs and valuation, and aggregate adoption predictions by OUC distribution feeder. We find substantial spatial heterogeneity in the projected level of adoption by OUC distribution feeder. For instance, 25% of all projected adoption through 2050 would be concentrated on just 5% of feeders and 88% of projected adoption on 50% of feeders. Because of the uncertainty in adoption, bottoms-up solar adoption forecasting methods at the household-level are integral to long-term resource planning by anticipating system needs as customers increasingly adopt distributed solar, storage, electric vehicles, and other distributed energy resources.

14 SOLAR ENERGY↗

Power System Resilience Metrics Augmentation for Critical Load Prioritization

One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thirty Minutes Before the Dawn

The Trinity test of July 16, 1945, marked the scientific apex of the Manhattan Project. Often recognized as the symbolic birth of the nuclear age, Trinity’s multifaceted legacy remains just as captivating and complex today as it did 75 years ago. This paper examines why the test was necessary from a technical standpoint, shows how Los Alamos scientists planned the event, and explores the physical and emotional aftermaths of Trinity. The author also uses rarely accessed original records to reconstruct the story of Trinity’s health hazards, as seen through the eyes of radiation technicians and medical doctors as events unfolded. Trinity was conducted as the Potsdam Conference began, weeks after the collapse of Nazi Germany. It was considered necessary to let President Harry S. Truman know whether the United States possessed a nuclear capability ahead of his negotiations with Joseph Stalin, the Soviet premier. The author examines the competing priorities that drove the timetable for the test: international politics, security, and safety. Three weeks after Trinity, a gun-assembled enriched-uranium bomb called Little Boy was used against the Japanese city of Hiroshima. Three days later, Fat Man, a weaponized version of the imploding Trinity device, was dropped on Nagasaki. The author briefly examines these strikes and what impact they may have had on the Japanese surrender. The paper concludes by examining the legacy of the Trinity test 75 years into the age it helped usher in.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Distributed Acoustic Sensing (DAS) Seismic Monitoring of CO 2 Injected for Enhanced Oil Recovery in Northern Michigan (Volume II.C)

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. This report describes the monitoring study conducted to assess the effectiveness of DAS (Distributed Acoustic Sensing) -based VSP (Vertical Seismic Profiling) technology for delineating CO 2 injected into the Silurian-age pinnacle reefs in northern Michigan, the host rocks for the MRCSP Phase III demonstration project. The DAS VSP study was conducted in the Chester 16 reef, one of several reefs in Otsego County Michigan that is operated by Core Energy, LLC of Traverse City, Michigan. Time-lapse DAS VSP was implemented at the Chester 16 reef to attempt to detect approximately 85,000 tonnes of CO 2 injected into the A-1 Carbonate and Brown Niagaran Formations. A baseline survey was conducted in February 2017 prior to injecting CO 2 and a repeat survey was conducted in August 2018. During the interim period between the baseline and repeat surveys, CO 2 was injected into the Chester 16 reef via the 6-16 injection well without production (withdrawal) of fluids from the reef. A grid of 181 source positions consisting of 44 vibrator positions, plus 137 dynamite shot locations, was used to give approximately continuous spatial coverage of the injection zone (A-1 Carbonate and upper Brown Niagaran) in the area between the two wells.

01 COAL, LIGNITE, AND PEAT↗

Assessing Climate Risks to Midwest Infrastructure Workshop

Stakeholders in industry, agriculture, and city governments are struggling to understand how to manage climate change risks. Climate scientists, meanwhile, want to know what specific information their fellow citizens need from them to take action.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Impact of Wall Control Performance on Connected Lighting Systems

Wall controls form the only touchpoint for individual room users and that room’s lighting control system. As such, these interfaces strongly influence user understanding and utilization of the system, as well as overall acceptance. The Next Generation Lighting Systems (NGLS) program began an evaluation of the wall controls in 14 connected lighting systems installed in various rooms of the NGLS Living Lab at Parsons School of Design in New York City. These systems demonstrate the wide range of approaches to wall control setup and functionality taken by manufacturers. Characterizing the 14 controls across six attributes, only four, or 29%, were identical. Requirements for wall control design were not specified explicitly by NGLS. Rather, wall controls were required to provide system performance according to three criteria: vacancy control (manual on/auto off) of two zones; manual continuous dimming of the same two zones; and an AV presentation mode in one of the two zones. This report examines the classification of entries, the assessment method used to evaluate the systems from installation through day-to-day use, and the system performance observed to date for each.

42 ENGINEERING↗

Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) Science Plan

Coastal cities provide the opportunity to characterize marine clouds and the substantial effects of manmade particles on cloud properties and processes. La Jolla lies to the north of San Diego, California, but it is often about a day directly downwind of the major pollution sources located in the ports of Los Angeles and Long Beach. The large dynamic range of aerosol particle concentrations combined with the multi-hour to multi-day persistence of stratocumulus cloud layers makes the site ideal for investigating the seasonal changes in cloud and aerosol properties as well as the quantitative relationships between cloud and aerosol properties.

54 ENVIRONMENTAL SCIENCES↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 13: Functional Specification Report(Deliverable D9))

This report provides functional specification for the AGGREGATE project and associated modules/ tools being developed for outage management and restoration with the Distributed Energy Resources (DERs). This report also provide initial validation of the developed modules and performance metrics. The AGGREGATE team at this stage has been collaborating with General Electric (GE) and Seattle City Light (SCL) to move forward from offline validation to online validation using commercial advanced distribution management system (ADMS). Hence, the functional specifications documents, which outline the requirement of various modules, is provided to address the integration of the modules, including 1) real-time model update and aggregation tools module, 2) observability and controllability metric module, 3) fault location solution service restoration module, 4) transmission-distribution co-simulation module, and 5) advanced distribution management system module. integration of different AGGREGATE modules and functional specification provides the foundation for online multi-scenario testing using SCL system model.

42 ENGINEERING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 14: Model Verification/Validation Test Plan (Deliverable D10))

This report summarizes the technical progress and validation plan for each of AGGREGATE project modules, and integrated modules. The overall validation plan can be divided into two major parts. Firstly, it provides offline validation results of each module using the IEEE-123 node distribution system with certain modifications to support individual module results verification. The offline validation plan tentatively validated the usability and practicability of developed AGGREGATE tools. Secondly, the realworld test system - Seattle City Light (SCL) test feeder for verifying each module and the integrated modules using GE advanced distribution management system (ADMS) software.

42 ENGINEERING↗

College-bound cowboys: The Los Alamos Ranch School Before the wartime lab, Los Alamos was home to a boarding school

Summer’s over and the school year’s soon to start. What’s a kid to do? Go West, young man! Escape the city that is “making you soft” and learn self-reliance from the western U.S. of A. – or so advertised the ranch school movement in America from roughly 1900-1960. This educational movement included Los Alamos. Before being developed into a wartime lab to create atomic weapons, the mesa was home to one of the most prominent and pricey ranch schools in America.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

An Observational Understanding of Connected Lighting Systems

As part of the Internet of Things (IoT), connected lighting systems provide additional control capabilities and nonlighting-related services (such as communications and data infrastructure) to reduce energy use while increasing both application efficiency and system value. But the positive or negative energy impact of implementing these systems is still largely unknown due to the variety of human factors associated with installation, maintenance, and use. These complications interfere with adoption and acceptance rates of products that will play a significant role in achieving energy savings long-term. Next Generation Lighting Systems, or NGLS, developed and implemented an observational research methodology for connected lighting systems. The methodology was implemented at an indoor (classroom/office) Living Lab at Parsons School of Design in New York City, and an outdoor (parking lot) Living Lab at Virginia Tech Transportation Institute in Blacksburg, Virginia. Although this report focuses on the approach to indoor installations, observational research in both settings provides insight to the type, scale, and frequency of issues across available products as experienced by installing contractors, end users, and other stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Influence of Communication on the Complexity of Connected Lighting Systems

Experience in the Next Generation Lighting Systems (NGLS) ”Living Lab” at the Parsons School of Design, has clearly shown the impacts of communication on the configuration complexity of the connected lighting systems installed there. Since 2017, NGLS has invited manufacturers to submit connected lighting systems for assessment against a set of specifications. To date, 14 systems of wirelessly connected LED luminaires and controls have been installed in classrooms with existing lighting. In nine of the rooms, new LED linear pendants or recessed troffers replaced existing luminaires; in the other rooms, LED “kits” were retrofitted into the existing troffers. Eleven of the installations featured sensors integrated in the luminaires or retrofit kits; the others used ceiling mounted sensors. All systems provided wall control devices for manual operation. For half of the installations, the complete systems were furnished by single companies; for the other half, luminaires and controls were furnished by separate companies. A total of 18 different companies provided products, with four of these located outside the United States including, Korea, Poland, Germany, and the Netherlands. In addition, two different electrical contractors in New York City provided multiple installation teams totaling 10 individuals, none of whom were familiar with any of the systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Remote Home Energy Score Assessments (Feasibility Study)

The delivery of Home Energy Scores (HES) has been significantly impacted over the last year by the recent pandemic and ongoing limitations to person-to-person interactions. There are also historic challenges in providing HES to more remote geographies where assessor infrastructure is not in place. Alternative approaches to in-person, on-site home energy assessments could help address these current restrictions, while also potentially providing opportunities for the efficient delivery of HES in certain use cases after COVID-related restrictions are lifted. From the program administrator’s perspective, there needs to be confidence that the remote scores closely match what they would have been if the assessment had been performed on-site. The recommendations shown on a report generated from a remote score should closely match those of an onsite assessment. A remote assessment should be an option for all HES Partners and have direction on how to deliver those scores. From the HES partner’s and assessor’s perspective, there needs to be understanding of what level of experience is needed, what system infrastructure is required, the time expenditure of the remote assessment process, and the limitations of a remote assessment. From the homeowner’s perspective, there needs to be an awareness and comfort with the time commitment, the level of knowledge of the home, the equipment needed, and any physical requirements of the remote assessment process. During this study, Earth Advantage assessed methods for delivering Home Energy Score assessments remotely through web-based technology platforms and resident interaction in a diverse array of home types in different geographic locations. Earth Advantage developed remote assessment test protocols and integrated those testing protocols into existing Home Energy Score programs being overseen by USDOE Home Energy Score partners New York State Energy Research & Development Authority (NYSERDA), the Oregon Department of Energy (ODOE), and the City of Portland (PDX). Earth Advantage staff acted as the Remote assessor and gathered HES data remotely during the video sessions with participants. Authorized Home Energy Score assessors performed the onsite assessments that were then used to compare with the remote assessment data. This allowed the research to effectively test the efficacy of various remote assessment approaches in a diverse array of home-types. Earth advantage identified the key components of a remote assessment infrastructure which included Remote Home Energy Score Assessments Page vi processes, tools, services, methods and mechanisms that would better enable remote assessments. This report details methods, results, and findings of the HES remote assessment research. In addition, the report provides recommendations and best practices that could be used as guidance for the Home Energy Score administrator and the HES partners seeking to effectively conduct remote assessments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transportation Hub Infrastructure Expansion: Decision Support Under Uncertainty

The Athena project (www.athena-mobility.org) has worked to investigate the relationship between the Dallas-Fort Worth Airport (DFW) and the greater Dallas area in order to better understand and therefore better inform future decision-making regarding the critical infrastructure that influence mobility between the airport and the city. Through this work, infrastructure related to curbside pickup and drop-off, parking, public transit, and the road network congestion were identified as critical to the operation of the DFW transportation hub. The infrastructure analysis and expansion aspect of the Athena project is focused on the restructuring of the CTA curb as a hierarchical curb and the building or repurposing of parking infrastructure as the interplay between these two areas. Many sources of uncertainty exist that may impact future airport and transportation hub operations, such as passenger volume growth, population demographic changes over time, electric vehicle (EV) adoption rates, and autonomous vehicle (AV) adoption rates. Due to these sources of uncertainty, we have selected for our research a modeling framework that can capture various types of uncertainty and hedge against those uncertainties in the optimization process. We analyze road network and curb congestion, the rise of transportation networking companies, trends in parking usage, existing policies around this infrastructure, airport revenue streams, and other contributing factors to enable infrastructure decision making with less uncertainty. To accomplish this wholistic analysis, we have developed a novel multi-stage, multi-period stochastic optimization model which considers the airport's decisions from 2025-2045 under different possible future macro trajectories and day-to-day variations in operational conditions captured as "annual representation of operations" scenarios with respective probabilities. This model has also been designed to leverage the outputs of various efforts under the Athena project to create a combined decision framework for infrastructure decisions. These various efforts include the route optimization model, the ASPIRES simulation, the mode choice model, and the SUMO traffic simulation. Our computational experiments of this system at scale have resulted in a working version of our infrastructure model which enables the explicit representation and consideration of various sources of uncertainty in the decision process to enable robust, flexible decision-making. This model has been effectively run on NREL's HPC system, Eagle, with large numbers of stochastic scenarios and shows promise as a scalable tool for robust consideration of uncertainties in airport planning. We have tested our model using 30,240 operational circumstances in total, resulting in a problem with more 200 million variables. This model was solved in several different configurations, and a workflow to simulate the performance of the infrastructure model results was developed and deployed. In general, our results indicate that a combination of remote parking, remote curb infrastructure, and dynamic pricing can generate revenue, reduce emissions, accommodate emerging technologies such as AVs and EVs, and manage airport passenger growth over time. We note the success of the proposed strategy depends on the data collection and forecasting abilities of DFW. We have also seen that the AV adoption by TNCs might necessitate larger amounts of remote curb. The results of this work inform strategies for airport infrastructure decision making, as well as demonstrate the value of an adaptable model, but also indicate that there are avenues remaining where further research would be of value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗