Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Model Development for the ACME Lab Modular Wall and A-Frame Assemblies

The structural frame used for conducting large structural tests was replaced by the ACME (Applied Combined Mechanical Environments) Lab in Building 860 of Sandia National Laboratories in Albuquerque, NM. This new design required simulation and analysis to verify maximum loads and corresponding factors of safety. Two major assemblies which are part of the ACME Lab, the Modular Wall and A-Frame, were designed to operate with a multitude of components in various configurations and with varying loads. Simulations of the Modular Wall and A-Frame structures were performed through explicit analysis to determine safety factors for numerous loading scenarios. The Modular Wall had safety factors of 1.1 for the lateral, diagonal, and gusset loading conditions. The A-Frame had safety factors of 2 for all loading conditions simulated.

42 ENGINEERING↗

Definition of large components assembled on-orbit and robot compatible mechanical joints

One of four major areas of project Pathfinder is in-space assembly and construction. The task of in-space assembly and construction is to develop the requirements and the technology needed to build elements in space. A 120-ft diameter tetrahedral aerobrake truss is identified as the focus element. A heavily loaded mechanical joint is designed to robotically assemble the defined aerobrake element. Also, typical large components such as habitation modules, storage tanks, etc., are defined, and attachment concepts of these components to the tetrahedral truss are developed.

Williamsen, J.↗

Operating Deflection Shapes for the Space Shuttle Partial Stack Rollout

In November of 2003 a rollout test was performed to gain a better understanding of the dynamic environment for the Space Shuttle during transportation from the Vehicle Assembly Building to the launch pad. This was part of a study evaluating the methodology for including the rollout dynamic loads in the Space Shuttle fatigue life predictions. The rollout test was conducted with a partial stack consisting of the Crawler Transporter, Mobile Launch Platform, and the Solid Rocket Boosters with an interconnecting crossbeam. Instrumentation included over 100 accelerometers. Data was recorded for steady state speeds, start-ups and stops, and ambient wind excitations with the vehicle at idle. This paper will describe the operating deflection shape analysis performed using the measured acceleration response data. The response data for the steady state speed runs were dominated by harmonics of the forcing frequencies, which were proportional to the vehicle speed. Assuming a broadband excitation for the wind, analyses of the data sets with the vehicle at idle were used to estimate the natural frequencies and corresponding mode shapes. Comparisons of the measured modal properties with numerical predictions are presented.

Buehrle, Ralph D.↗

The Liquid Nitrogen System for Chamber A: A Change from Original Forced Flow Design to a Natural Flow (Thermo Siphon) System

NASA Johnson Space Center (JSC) in Houston is currently supplementing its 20K helium refrigeration system to meet the new requirements for testing the James Web Space Telescope in the environmental control Chamber-A (65 dia x 120 high) in Building 32. The new system is required to meet the various operating modes which include a high 20K heat load, a required temperature stability at the load, rapid (but controlled) cool down and warm up and bake out of the chamber. This paper will present the proposed modifications to the existing helium system(s) to incorporate the new requirements and the integration of the new helium refrigerator with the existing two 3.5KW 20K helium refrigerators. In addition, the floating pressure process control philosophy to achieve high efficiency over the operating range (40% to 100% of the refrigeration system capacity), and the required temperature stability of +/- 0.25 K at the load will be discussed. The refrigeration systems ability to naturally seek the operating conditions under various loads and thus minimizing operator involvement and the over all improvements to the system operability and the reliability will be explained.

Homan, Jonathan↗

Modal Testing of a Flexible Wing on a Dynamically Active Test Fixture Using Fixed Base Correction Method - IFASD 2019

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, but do not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the test article frequency range of interest. The dynamic coupling between the test article and test fixture complicates the model updating process because significant effort needs to be spent on modeling the test fixture and boundary conditions in addition to the test article. If the modal results could be corrected for fixture coupling, then setups used for other structural testing could be adequate for modal testing and would allow significant schedule and cost savings by eliminating a unique setup for only modal testing. To simplify future modal tests, this paper reports on a fixed base correction method that was investigated during modal testing of a full-scale, half-span, flexible wing cantilevered from a static test fixture. The results of this fixed base correction approach look very promising. The method aided in producing similar wing modal characteristics for two different physical boundary configurations of a dynamically active test fixture.

modal testing↗

Passive Aeroelastic Tailored Wing Modal Test Using the Fixed Base Correction Method

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, but do not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the frequency range of interest of the test article. Dynamic coupling between the test article and test fixture complicates the model updating process because significant effort is required to model the test fixture and boundary conditions in addition to the test article. If there were a way to correct the modal results for fixture coupling, then setups used for other structural testing could be adequate for modal testing. In the case described in this paper, a partial static loads testing setup was used, which allowed significant schedule and cost savings by eliminating a unique setup for a modal test. A fixed base correction technique was investigated during modal testing of a flexible wing cantilevered from part of a static test fixture. The technique was successfully used to measure the wing modes de-coupled from the dynamically active test fixture. The technique is promising for future aircraft applications, but more research is needed.

structural dynamics↗

Modal Testing of a Flexible Wing on a Dynamically Active Test Fixture Using the Fixed Base Correction Method

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, and not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the test article frequency range of interest. The dynamic coupling between the test article and test fixture complicates the model updating process because significant effort needs to be spent on modeling the test fixture and boundary conditions in addition to the test article. If the modal results could be corrected for fixture coupling, then setups used for other structural testing could be adequate for modal testing and would allow significant schedule and cost savings by eliminating a unique setup for only modal testing. To simplify future modal tests, this report describes a Fixed Base Correction method that was investigated during modal testing of a full-scale, half-span, flexible wing cantilevered from a static test fixture. The results of this Fixed Base Correction approach look very promising. The method aided in producing similar wing modal characteristics for two different physical boundary configurations of a dynamically active test fixture.

Natalie D Spivey↗

Physical Properties of Hilti HIT-RE 500 V3 After Irradiation: Slant Shear, Tensile, Flexural, and Compressive

There are various applications in which epoxy adhesives may be used within hot-cell environments. These epoxies currently see limited use within hot cells since it is known that organics see degradation after small doses even as low as 50 kilogray (kGy). These losses in physical property strengths limit the use of these epoxies to non-structural applications. In modern construction, however, the use of epoxies to bond structural components such as rebar or threaded anchors is becoming increasingly prevalent. To employ these types of materials the Idaho National Laboratory (INL) has begun investigating the specific degradation properties of epoxies for use in structural applications in environments where radiation is present. Hilti HIT-RE 500 V3 is used extensively in new construction and renovation projects across the world. The INL has conducted various tests on this epoxy for low dose environments. These tests include tensile, flexural, compression, and slant shear tests following the American Society for Testing Material International (ASTM) standards D638, D790, D695, and C882/882M respectively. Two sample sets for each test were created where the baseline specimens were not irradiated, and another set was irradiated to an accumulated dose of approximately 50-60 kGy. All the samples were destructively tested and analyzed focusing on the change in physical properties, examples of these tests are shown in Figures 1-4. Tensile testing results indicate a 0.9% loss in maximum load capacity, a 0.5% loss in tensile stress at maximum load, a 1.4% loss in tensile strain at break, and a 15% decrease in modulus of elasticity. Flexural testing results display an increase in all the following: 12% in strain at maximum load, 10% in maximum load capacity, 5% in stress at maximum load, and 3% in young’s modulus. The compressive physical properties after irradiation display a 1% increase in maximum load, a 3% decrease in stress at yield, and a 5% decrease in modulus of elasticity. The maximum compressive stress saw no measurable change after irradiation. The slant shear specimens after irradiation displayed a 2% increase in maximum load capacity and maximum compressive stress. Though a structural analysis would have to be completed as is normal for building design the increases and decreases in the measured physical properties indicate that this material may be used for structural applications in low dose hot-cell environments without adhesive failure.

36 MATERIALS SCIENCE↗

Alfalfa Virtual Building Service: Software Engineering Best Practices Applied to Runtime Interaction with Building Energy Models

Buildings are active participants in increasingly complex energy systems. Building Energy Modeling (BEM) has a key role to play in planning and de-risking an equitable energy transition, with BEM-backed "virtual buildings" critical path for diverse applications that include workforce training tools, Hardware-in-the-Loop (HIL) experimentation to study equipment performance under a range of conditions, Control-Hardware-in-the-Loop (CHIL) experimentation to de-risk commercial control implementations at equipment through grid orchestration levels, and integration of dynamic load profiles into grid modeling tools for energy system experimentation at the urban scale. Modeling requirements vary across these applications, but many software engineering tasks do not. The Alfalfa Virtual Building Service (AVBS, see https://github.com/NREL/alfalfa/wiki) is an open-source web service that solves these common tasks robustly in one place, providing a foundational platform for power users to bootstrap their own applications. AVBS abstracts the specifics of runtime interaction with OpenStudio, Modelica, and Spawn of EnergyPlus models behind a unified REST API. Additionally, AVBS provides resources for cloud deployment and scaling to 100s of parallel simulations, a growing library of modular Operational Technology (OT) integrations for emulation of real-world interfaces, and scripts to automate the population of communities of virtual buildings from URBANopt, ResStock and ComStock.

building automation↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY2021 Rotating Bed Reactor for Iodine Removal from ETF Feed to Support DFLAW Start-Up

In FY20, Washington River Protection Solutions, LLC (WRPS) began a program of work to evaluate potential technologies for removal of iodine from the ETF feed. Work at the Pacific Northwest National Laboratory (PNNL) focused on ion exchange media and conventional column based deployment while Atkins and VSL focused on ion exchange media in a Rotating Bed Reactor (RBR) system. In the RBR system, the ion exchange media is loaded into a packed bed, which is rotated in the liquid to be treated. The work described in this report builds on the results from FY20 work, in particular, with regard to improving iodate removal, extending the data set to support process modeling, further comparison of RBR versus column performance, and RBR scale-up testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Controls Package for High Performance Interior Retrofit [Slides]

For the last few years, networked lighting control (NLCs) have promised significant energy savings beyond what is achieved through a basic light-emitting diode (LED) lighting retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Explicit Dynamic Impact Analysis of the Building 3525 Packages

This report describes the methodology used for the safety basis analysis of the Building (Bldg.) 3525 casks and presents preliminary results for a selected geometry. The specific problem analyzed is a free fall load case onto an unyielding target at various orientations. The various orientations were analyzed to ensure that the packages were subjected to the orientation that causes the most damage. The analysis approach, material modeling, finite element modeling, and results for the selected case are presented, along with a brief discussion of conservatism and uncertainties. The results for the analyzed load cases show that through selected administrative controls, no breach of the container or loss of shielding will occur in the package.

42 ENGINEERING↗