Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Alfalfa Virtual Building Service: Software Engineering Best Practices Applied to Runtime Interaction with Building Energy Models

Buildings are active participants in increasingly complex energy systems. Building Energy Modeling (BEM) has a key role to play in planning and de-risking an equitable energy transition, with BEM-backed "virtual buildings" critical path for diverse applications that include workforce training tools, Hardware-in-the-Loop (HIL) experimentation to study equipment performance under a range of conditions, Control-Hardware-in-the-Loop (CHIL) experimentation to de-risk commercial control implementations at equipment through grid orchestration levels, and integration of dynamic load profiles into grid modeling tools for energy system experimentation at the urban scale. Modeling requirements vary across these applications, but many software engineering tasks do not. The Alfalfa Virtual Building Service (AVBS, see https://github.com/NREL/alfalfa/wiki) is an open-source web service that solves these common tasks robustly in one place, providing a foundational platform for power users to bootstrap their own applications. AVBS abstracts the specifics of runtime interaction with OpenStudio, Modelica, and Spawn of EnergyPlus models behind a unified REST API. Additionally, AVBS provides resources for cloud deployment and scaling to 100s of parallel simulations, a growing library of modular Operational Technology (OT) integrations for emulation of real-world interfaces, and scripts to automate the population of communities of virtual buildings from URBANopt, ResStock and ComStock.

building automation↗

Electrifying New York’s Affordable Housing

Enterprise Community Partners (Enterprise) joined forces with the Association for Energy Affordability (AEA), with support from the New York City Department of Housing Preservation and Development (HPD) and New York State Homes and Community Renewal (HCR). Through this 3-year pilot project, the project partners collaborated to develop tools and processes that efficiently utilize New York State Weatherization Assistance Program (WAP) funding to both improve energy efficiency through weatherization and to convert to clean heating systems through electrification. We developed and piloted this approach on five multifamily dwelling buildings, totaling 154 units in New York City, using the energy audit protocol that was developed as part of this project. Our goal was to develop a basis of knowledge for pursuing similar retrofits nationwide.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bishop Paiute Single Family Solar Home Project: Phase 4 (Final Technical Report)

The Bishop Paiute Tribe is committed to energy efficiency, renewable energy, and environmental protection and has a vision to install solar energy systems on all buildings on the Reservation where technically feasible. Through completion of the Bishop Paiute Tribe Residential Solar Program – Phase 4, Bishop Paiute Tribe continued its successful model partnering with non-profit solar installer GRID Alternatives to advance its vision and build energy self-sufficiency on the Bishop Paiute Reservation. The Bishop Paiute Tribe Residential Solar Program – Phase IV deployed 67 kW-AC of new clean, renewable energy through grid-tied, net-metered rooftop solar electric systems installed on a total of 20 (one more than the planned 19) existing owner-occupied, single-family homes for low-income families on the Reservation. This represents nearly 14% of the Reservation’s total “unsolarized” homes. These systems were provided at no cost to the homeowners, who will also receive energy efficiency education to further reduce energy consumption and lower electric bills. GRID led a solar installation for three (3) of the homes where Tribal/community members, were given an opportunity in participating in on-the-roof trainings to gain new skills while installing solar for their low-income community members. Subcontractors through GRID Sub Contractor Partnership Program (GRID SPP) led solar installations for seventeen (17) of the homes. Each installation provided paid employment for a solar trainee trainees hired by the SPP subcontractors as entry level solar installers. It is estimated that the installed 67 kW-AC of solar will produce at least 120,000 kWh/year, displacing at least 30-75% of the 20 homes’ total electricity use for a combined system lifetime electricity cost savings for the low-income homeowners of about $\$$500,000. It is further estimated that the installed renewable energy systems installed will prevent greenhouse gases by about 1,000 tons, equivalent to planting approximately 25,000 trees. Following the successful completed installations, it is expected that the Reservation and surrounding communities will benefit from improved air quality via reduced wood stove use for heating. Cumulatively with other initiatives, the project will result in nearly 40% of the Reservation’s solarizable homes being solarized. Overall, the triple impact of the phase 4 of the Bishop Paiute Tribe Residential Solar Program – Phase 4 is: 1) affordable energy for low-income families; 2) on-site clean energy production, 3) hands on training and paid solar installation work for local tribal/community workers. These impacts will support and grow the Tribe’s energy, economic, environmental, and social self-sufficiency and sovereignty amongst the neediest on the Reservation.

14 SOLAR ENERGY↗

Power efficient optical communications for space applications

Optical communications technology promises substantial size, weight and power consumption savings for space to space high data rate communications over presently used microwave technology. These benefits are further increased by making the most efficient use of the available optical signal energy. This presentation will describe the progress to date on a project to design, build and demonstrate in the laboratory an optical communication system capable of conveying 2.5 bits of information per effective received photon. Such high power efficiencies will reduce the need for photon collection at the receiver and will greatly reduce the requirements for optical pointing accuracy, both at the transmitter as well as the receiver. A longer range program to demonstrate even higher photon efficiencies will also be described.

Lesh, J. R.↗

Building commissioning costs and savings across three decades and 1500 North American buildings

B.V. Building commissioning (Cx) is a process for assuring efficient building operations that can be applied to new construction and existing buildings, resulting in energy and non-energy benefits. Quantifying the benefits of commissioning is challenging, but a 2009 study of 643 commercial buildings provided a solid initial data set to which we added 839 additional buildings for a significantly expanded and updated meta-analysis representing 34.7 million square meters (373 million square feet) of floor area. Since 2009 the commissioning industry has continued to grow, driven by building codes, utility programs, and rising awareness of commissioning benefits. In parallel, building controls have become more sophisticated, and analytics software has emerged to assist with commissioning. We find that delivery mechanism and market segment are key determinants of outcomes, although significant and cost-effective savings are found across the spectrum. Median primary energy savings for Cx projects in existing buildings ranged from 5 percent for those conducted under utility programs, 9 percent for monitoring-based commissioning utility programs (i.e., augmented with submetering and diagnostics), and 14 percent for Cx projects outside of utility programs. Across all project types, median savings ranged from 3 percent for the lodging market segment to 16 percent for public order and safety facilities. Outcomes did not vary significantly by building size or by market segment. Energy savings are rarely estimated for new construction commissioning. We found that the median costs of Cx were lower for the 2018 sample than for the 2009 sample—$\$$2.85 per square meter ($\$$0.26 per square foot) for existing buildings (a 33 percent reduction) and $\$$8.78 per square meter ($\$$0.82 per square foot) for new construction (a reduction of almost 50 percent). The median simple payback time for existing buildings was 1.7 years, with a 25th–75th percentile range of 0.8–3.5 years. Overall, this article summarizes these and other key findings, and discusses how the 2018 data reflects shifts in commissioning practice and outcomes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review: Sensor Impact on Building Controls and Automatic Fault Detection and Diagnosis (AFDD)

This report summarizes a literature review as a Q1 deliverable of the “Sensor Impact Evaluation and Verification” project. This project’s overarching goal is to develop a framework for investigating the impact of sensor deployment and configuration for building energy optimization, fault detection and diagnosis (FDD), occupants’ thermal comfort, and potential grid efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The design of a solar energy collection system to augment heating and cooling for a commercial office building

Analytical studies supported by experimental testing indicate that solar energy can be utilized to heat and cool commercial buildings. In a 50,000 square foot one-story office building at the Langley Research Center, 15,000 square feet of solar collectors are designed to provide the energy required to supply 79 percent of the building heating needs and 52 percent of its cooling needs. The experience gained from the space program is providing the technology base for this project. Included are some of the analytical studies made to make the building design changes necessary to utilize solar energy, the basic solar collector design, collector efficiencies, and the integrated system design.

Basford, R. C.↗

High-Performance Windows -- More than just a Pretty Hole in the Wall

As more stringent building energy codes and better insulation products combine to yield better performing walls, window efficiency is coming into sharper focus. The U.S. Department of Energy has supported several projects through its national laboratories to improve the thermal performance of windows. At Pacific Northwest National Laboratory (PNNL) in Richland, Washington, the PNNL Lab Homes, two fully monitored identical side-by-side manufactured homes, have been used to test the performance of several window improvements including triple-pane windows, storm windows with low-emissivity (low-e) coatings, smart automated interior insulated shades, and exterior shading products. Findings will be presented on these studies, along with impacts. For example, PNNL’s Lab Home research on low-e storm windows has helped to support a new ENERGY STAR certification, industry standards, and utility incentives. Preliminary findings will also be presented on current Lab Homes experiments focusing on exterior shades. The session will also present findings from related field studies and a market assessment of emerging high-efficiency windows technologies and discuss some of PNNL’s planned field studies that will focus on validating the benefits and costs of the emerging thin triple-pane high-R window.

windows, high-r windows, insulating windows, windo↗

Commercial Building Sensors and Controls Systems: Barriers and Drivers: Preprint

Building sensors and controls systems, including building automation systems, comprise the sensor-based devices installed in buildings as well as the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 13% of small commercial buildings, however, have installed sensors and controls systems, largely because of cost barriers. To accelerate adoption, this work seeks to increase the transparency of system costs and identify specific barriers and drivers. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 21 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. We collected the cost data in the form of invoices and used it to develop a percentage-based cost category breakdown. The interview data were analyzed using grounded theory to identify overarching concepts such as barriers, drivers, and future directions. From this analysis, we found the primary barriers to be complex and confusing systems, lack of user skills, and financial concerns, and the primary drivers to be operational benefits, insight into operations, and remote access to data. The future directions analysis highlighted the potential technological solutions to address gaps and barriers, as well as predicted drivers to increase adoption. This greater understanding of the costs, barriers, and drivers associated with commercial building sensors and controls systems lays the groundwork for increasing system adoption, reducing energy consumption, and transforming the market.

building automation system↗

Commercial Building Sensors and Controls Systems: Barriers, Drivers, and Costs

Building sensors and controls systems, including building automation systems, consists of the sensor-based devices installed in buildings and the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 8% of small commercial buildings, however, have installed sensors and controls systems. This is largely due to cost barriers. This work seeks to increase the transparency of system costs and identify specific barriers and drivers for increased adoption. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 20 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. The qualitative interview data was analyzed using grounded theory to identify overarching concepts, such as barriers, drivers, and future directions on the field. From this analysis, primary barriers were found to be complexity, a lack of knowledge, and money. Primary drivers were found to be the knowledge of data, savings, and remote access. The qualitative cost data was collected in the form of invoices during the interviews. The cost values were used to develop a percentage-based cost stack which identifies the average fraction of the total cost attributed to each category (hardware, software, labor, fees, and taxes). This greater understanding of costs and barriers associated with commercial building sensors and controls systems lays the groundwork for future steps in increasing system adoption, reducing energy consumption, and market transformation.

advanced building controls↗

Radiative Cooling Paints: Application on Warehouses and Integration with Phase Change Materials

Despite extensive research on radiative cooling (RC), researchers are still working to understand its best implementation strategy and potential benefits. Understanding this could be an instrumental part of reducing building energy costs and combating climate change. In this work, we introduce two concepts to achieve this goal and broaden the application of RC paints. While building energy simulations for RC are common, most studies focus on single-layer paints in residential settings. Limited research exists on warehouses, and no literature has conducted multi-climate zone analyses or included RC technologies with >90% reflectance. As RC technology advances in efficiency, versatility, and affordability, large-scale simulations across diverse climates are crucial, particularly for warehouses as a passive indoor temperature control solution. Here, a TRNSYS-modeled single-story warehouse assesses the energy impact of BaSO4-based RC paints. Another under-explored RC application is its integration with phase change materials (PCMs), which provide thermal regulation via latent heat storage. Though RC and PCMs have been combined by placing PCMs atop, beneath, or within RC layers, studies focus on either experiments or modeling, with no validation between the two. Here, we develop a simple RC+PCM experimental and modeling setup, placing RC paint atop an aluminum cell filled with a Rubitherm PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transforming New Multifamily Construction to Zero: Strategies for Implementing Energy Targets and Design Pathways: Preprint

Creating zero energy (ZE) mid- to high-rise multifamily buildings represent significant challenges in the design world. Tenants often take responsibility for some of the utilities and are responsible for consumption of some of the largest end uses: hot water and plug loads. Furthermore, designers can experience risk in creating new sets of details and recommending new strategies to reach aggressive EUI targets. To assist in a more streamlined and successful design approach to ZE multifamily buildings, five major professional societies and experts from the multifamily space created a Zero Energy Advanced Energy Design Guide (AEDG) for multifamily buildings based on data driven results coupled with actual design experiences and case studies. Pathways to achieve ZE design were established including whole building energy use intensity targets coupled with details on how to achieve success in implementing individual efficiency measures. The guidance strives to overcome design barriers and this paper provides an overview of the recommended process to achieve ZE or ZE-ready status, along with details on selecting energy targets, and strategy pathways to achieve the targets.

advanced energy design guide↗

End-Use Load Profiles for the U.S. Building Stock

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute resolution load profiles for all major residential and commercial building types and end uses, across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

Array↗

Chapter 7: Principles of Northern Housing Design with Examples from Alaska

The Arctic has unique challenges and needs with respect to housing due to extreme climate, remoteness of communities, cultural aspects, and other factors. Attempts to adopt designs from other regions often resulted in failures, such as rotten building envelopes or features incompatible with local values. The main goal of this chapter is to inform a broad audience involved in northern housing about basic principles important for the Arctic. Particular attention is given to energy efficiency, health and durability, foundations appropriate for the underlying terrain such as permafrost, inclusive design process to assure meeting cultural and other needs and building design factoring in seasonality and logistical challenges of remote communities. Examples of existing prototype homes are given throughout the chapter to demonstrate how the individual principles can be successfully applied in real-life scenarios. This chapter also covers current trends, what the future might look like, how it is informed by indigenous perspectives, and how northern housing design can influence approaches in other regions of the world. The ultimate goal is to contribute to a vibrant future of communities in the Arctic and beyond.

Arctic↗

Embodied Carbon Reduction in New Construction: Reference Guide

The U.S. Department of Energy launched the Advanced Building Construction (ABC) Initiative in 2019 to modernize and streamline building renovation and construction processes that facilitate the integration of high-performance and low-carbon solutions in the U.S. building stock. There are four attributes of ABC that are the focus of the Initiative: affordable, fast, appealing, and low carbon. Substantial improvements have been made to reduce operational carbon emissions of buildings through efficiency and electrification. However, to achieve low-carbon new construction buildings, increased efforts to reduce the embodied carbon of buildings are needed. Embodied carbon emissions in buildings come primarily from the manufacturing of building envelope materials such as concrete, steel, lumber, and glass, among others. Recent studies show that construction and renovation of buildings account for 5% of energy use and 10% of carbon emissions globally.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Fenestration Market Study

This study characterizes and assesses the U.S. commercial fenestration market. It analyzes a groundbreaking amount of data that will ultimately support an estimate of national savings potential of energy efficient fenestration products in commercial applications to demonstrate the benefits of efficient façade and fenestration systems. This study provides data and analysis on: commercial fenestration market and fenestration selection process, installed commercial fenestration stock across the U.S. and fenestration sales estimates, and current commercial building fenestration codes and market trends of installation to or above code.