At least 919 records · Page 51

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

Measurement of the energy-differential 35 Cl( n, p 0 ) 35 S cross section via the ratio with 6 Li( n, α ) 3 H

Knowledge of the neutron-induced 35 Cl ⁢(n, x) cross sections is vital to the design and certification of molten chloride fast reactors (MCFRs) since the 35 Cl (n, p 0 ) 35 S reaction is believed to be a significant reactor poison. However, recently published measurements are inconsistent with each other and with evaluation. Here, the goal of this work is to measure the 35 Cl (n, p 0 ) reaction cross section using a technique that is different from recent measurements. The experiment was conducted at Lawrence Berkeley National Laboratory's (LBNL) 88-Inch Cyclotron using thick target deuteron breakup from a 14 MeV deuteron beam. Energy-differential 35 Cl (n, p 0 ) 35 S cross sections were obtained via ratio with the 6 Li (n, a)⁢ 3 H reaction using an active target experiment with a Cs 2 ⁢LiYCl 6 (CLYC) scintillator. The 35 Cl (n, p 0 ) reaction cross section was measured from 2.02 to 7.46 MeV. The results are consistent with Kuvin et al., confirming a roughly 50% reduction in magnitude relative to the ENDF/B-VIII.0 evaluation. These data provide new insight into the role of natural Cl as an MCFR poison. The reduction of the 35 Cl (n, p 0 ) reaction cross section compared to evaluation suggests that MCFR criticality is less sensitive to Cl enrichment. This may in turn reduce building and operating costs since isotope separation may not be needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine learning enabled measurements of astrophysical (p,n) reactions with the SECAR recoil separator

he synthesis of heavy elements in supernovae is affected by low-energy (n,p) and (p,n) reactions on unstable nuclei, yet experimental data on such reaction rates are scarce. The SECAR (SEparator for CApture Reactions) recoil separator at FRIB (Facility for Rare Isotope Beams) was originally designed to measure astrophysical reactions that change the mass of a nucleus significantly. We used a novel approach that integrates machine learning with ion-optical simulations to find an ion-optical solution for the separator that enables the measurement of (p,n) reactions, despite the reaction leaving the mass of the nucleus nearly unchanged. A new measurement of the 58 Fe (p,n)⁢ 58 Co reaction in inverse kinematics with a 3.66 ± 0.12 MeV/nucleon 58 Fe beam (corresponding to 3.69 ± 0.12 MeV proton energy in normal kinematics) yielded a cross-section of 20.3 ± 6.3 mb and served as a proof of principle experiment for the new technique demonstrating its effectiveness in achieving the required performance criteria. This novel approach paves the way for studying astrophysically important (p,n) reactions on unstable nuclei produced at FRIB.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simultaneous prediction of structural properties in epitaxially–grown GaN with quantum and conventional multi–output learning algorithms

Hundreds of GaN thin film crystal plasma–assisted molecular beam epitaxy synthesis experiment records spanning two decades were organized into a dataset correlating the growth experiment design parameters with discrete, binary determinations of crystallinity and surface morphology. Conventional data science techniques as well as both quantum and classical multi–output supervised machine learning algorithms were implemented to investigate the relationships between the operating parameter data and the structural figures of merit. Correlation coefficients, decision tree nodes, p–values, and SHAP values all support substrate temperature and gallium effusion cell conditions as being statistically significant for simultaneously influencing GaN crystallinity and surface morphology. Here, a conventional deep neural network learned best from the data, followed by a quantum–classical hybrid gradient boosting algorithm. When combined with calculations of uncertainty intervals based on VennAbers predictors, machine learning predictions of both structural properties show good agreement with results reported in published experimental literature.

36 MATERIALS SCIENCE↗

Performance Optimization of the IOTA Duoplasmatron Proton Source

We present results from online optimization studies of a duoplasmatron ion source designed to produce 50~keV protons for acceleration to 2.5~MeV and subsequent injection into the Integrable Optics Test Accelerator (IOTA) at Fermilab. Using a Bayesian exploration technique, we developed multi-parameter models of the source s proton current and employed these models to optimize its performance. Depending on the spectrometer configuration used to isolate the proton beam and the chosen optimization objective, we identified three candidate operating points, achieving normalized 50~\% emittances between 0.57 and 1.3~\textmu m and a maximum proton current of $14.5 \pm 0.6$~mA.

Banerjee, Nilanjan [Fermilab] (ORCID:0000000344660↗

MEASUREMENT OF Fn 2 /Fp 2 FROM DEEP INELASTIC ELECTRON SCATTERING OFF A=3 MIRROR NUCLEI AT JEFFERSON LAB

This research is part of the Je?erson Lab MARATHON experiment (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A = 3 EMC E?ect in Deep Inelastic Electron Scattering Off the Tritium and Helium MirrOr Nuclei). MARATHON is an experiment on electron deep inelastic scattering off the 3H, 3He mirror nuclei. It has extracted, from the measured deep inelastic scattering cross section ratio o? 3H and 3He, the ratio of the neutron to proton inelastic structure functions Fn 2 /Fp 2 . The extraction has taken advantage of the isospin symmetry of the A = 3 mirror nuclei within a novel technique, which avoids the theoretical uncertainties that are present in the SLAC experiments of the 1970s, which used hydrogen and deuterium targets. The experiment was performed using the upgraded 11 GeV beam of the Jefferson Lab electron accelerator, the Hall A Experimental Facility, and a newly designed cryogenic, high-pressure gas target system containing 3H and 3He cells. Electrons scattered o? the gas targets were detected in the two superconducting, high-resolution magnetic spectrometers of Hall A. The cross section data cover the four-momentum transfer squared range 2.0 < Q2 < 14.0 (GeV/c)2, and the Bjorken x scaling variable range 0.19 < x < 0.83. The experiment also measured, for calibration purposes, electron deep inelastic scattering off hydrogen and deuterium at selected kinematics.

Su, Tong↗

PERLE: A novel facility for ERL development and applications in multi-turn configuration and high-power regime

The development of ERLs has been recognized as one of the five main pillars of accelerators R&D in support of the European Strategy for Particle Physics (ESPP). The international panel in charge of the ERL Roadmap definition recognized PERLE project as “a central part of the roadmap for the development of energy-recovery linacs”, with milestones to be achieved by the next ESPP in 2026. PERLE project is aiming at the construction of a novel ERL facility for the development and application of the energy recovery technique in multi-turn configuration, high current and large energy regime. It will operate in a 3-turns mode, first at 250 MeV, then upgraded to 500 MeV with 20mA beam current. Such challenging parameters make PERLE a unique multi-turn ERL facility operating at an unexplored operational power regime (10MW), studying and validating a broad range of accelerator phenomena, paving the way for the future larger scale ERLs. PERLE will be the necessary demonstrator for the future HEP machine (LHeC / FCC-eh), with which it shares the same technological choices and beam parameters. Furthermore, PERLE opens a new frontier for the physics of “the electromagnetic probe”. It will be the first ERL dedicated to Nuclear Physics for studying the eN interaction with radioactive nuclei. Here we will report on the project status, introduce the main ongoing achievements and describe the staged strategy we will adopt toward the construction of PERLE machine at its nominal performances.

Kaabi, Walid↗

High–Yield Deterministic Focused Ion Beam Implantation of Quantum Defects Enabled by In Situ Photoluminescence Feedback

Focused ion beam implantation is ideally suited for placing defect centers in wide bandgap semiconductors with nanometer spatial resolution. However, the fact that only a few percent of implanted defects can be activated to become efficient single photon emitters prevents this powerful capability to reach its full potential in photonic/electronic integration of quantum defects. Here an industry adaptive scalable technique is demonstrated to deterministically create single defects in commercial grade silicon carbide by performing repeated low ion number implantation and in situ photoluminescence evaluation after each round of implantation. An array of 9 single defects in 13 targeted locations is successfully created—a ≈70% yield which is more than an order of magnitude higher than achieved in a typical single pass ion implantation. The remaining emitters exhibit non-classical photon emission statistics corresponding to the existence of at most two emitters. This approach can be further integrated with other advanced techniques such as in situ annealing and cryogenic operations to extend to other material platforms for various quantum information technologies.

36 MATERIALS SCIENCE↗

Magnetic metamaterials by ion-implantation

We present a method for the additive fabrication of planar magnetic nanoarrays with minimal surface roughness. Synthesis is accomplished by combining electron-beam lithography, used to generate nanometric patterned masks, with ion implantation in thin films. By implanting 56 Fe + ions, we are able to introduce magnetic functionality in a controlled manner into continuous Pd thin films, achieving 3D spatial resolution down to a few tens of nanometers. Our results demonstrate the application of this technique in fabricating square artificial spin ice lattices, which exhibit well-defined magnetization textures and interactions among the patterned magnetic elements.

36 MATERIALS SCIENCE↗

Analysis of Needlet Internal Linear Combination performance on B -mode data from sub-orbital experiments

The observation of primordial B modes in cosmic microwave background (CMB) polarisation data represents the main scientific goal of most of the future CMB experiments. This signal is predicted to be much lower than polarised Galactic emission (foregrounds) in any region of the sky, pointing to the need for effective component separation methods. Aims. Among all the techniques, the blind Needlet Internal Linear Combination (NILC) is of great relevance given our current limited knowledge of the B-mode foregrounds. In this work, we explore the possibility of employing NILC for the analysis of B modes reconstructed from partial-sky data, specifically addressing the complications that such an application yields such as E–B leakage, needlet filtering, and beam convolution. We consider two complementary simulated datasets of future experiments: the balloon-borne Short Wavelength Instrument for the Polarisation Explorer (SWIPE) of the Large Scale Polarisation Explorer, which targets the observation of both reionisation and recombination peaks of the primordial CMB B-mode angular power spectrum, and the ground-based Small Aperture Telescope of Simons Observatory, which, instead, is designed to observe only the recombination bump at ℓ ~ 80. We assessed the performance of the following two alternative techniques to correct for the CMB E–B leakage: the recycling technique and the Zhao-Baskaran method. We find that both techniques reduce the E–B leakage residuals at a negligible level given the sensitivity of the considered experiments, except for the recycling method in the SWIPE footprint at ℓ < 20. Thus, we implemented two extensions of the pipeline, the iterative B decomposition and the diffusive inpainting, which enabled us to recover the input CMB B-mode power for ℓ ≥ 5. For the considered experiments, we demonstrate that needlet filtering and beam convolution do not affect the CMB B-mode reconstruction. Finally, with an appropriate masking strategy, we find that NILC foregrounds subtraction allows one to achieve sensitivities on the tensor-to-scalar ratio in agreement with the targets of the considered CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Variational Self-Consistent Theory for Beam-Loaded Cavities

A new variational theory is presented for beam loading in microwave cavities. The beam{field interaction is formulated as a dynamical interaction whose stationarity according to Hamilton’s principle will naturally lead to steady-state solutions that indicate how a cavity’s resonant frequency, Q and optimal coupling coefficient will detune as a result of the beam loading. A driven cavity Lagrangian is derived from first principles, including the effects of cavity wall losses, input power and beam interaction. The general formulation is applied to a typical klystron input cavity to predict the appropriate detuning parameters required to maximize the gain (or modulation depth) in the average Lorentz factor boost, (Δ γ). Numerical examples are presented, showing agreement with the general detuning trends previously observed in the literature. The developed formulation carries several advantages for beam-loaded cavity structures. It provides a self-consistent model for the dynamical (nonlinear) beam{field interaction, a procedure for maximizing gain under beam-loading conditions, and a useful set of parameters to guide cavity-shape optimization during the design of beam-loaded systems. Enhanced clarity of the physical picture underlying the problem seems to be gained using this approach, allowing straightforward inclusion or exclusion of different field configurations in the calculation and expressing the final results in terms of measurable quantities. Two field configurations are discussed for the klystron input cavity, using finite magnetic confinement or no confinement at all. Formulating the problem in a language that is directly accessible to the powerful techniques found in Hamiltonian dynamics and canonical transformations may potentially carry an additional advantage in terms of analytical computational gains, under suitable conditions

43 PARTICLE ACCELERATORS↗

Nanoscale Mass Spectrometry Multimodal Imaging via Tip-Enhanced Photothermal Desorption

Materials ranging from adhesives, pharmaceuticals, lubricants, and personal care products are traditionally studied using macroscopic characterization techniques. However, their functionality is in reality defined by details of chemical organization on often noncrystalline matter with characteristic length scales on the order of microns to nanometers. Additionally, these materials are traditionally difficult to analyze using standard vacuum-based approaches that provide nanoscale chemical characterization due to their volatile and beam-sensitive nature. Therefore, approaches that operate under ambient conditions need to be developed that allow probing of nanoscale chemical phenomena and correlated functionality. Here, we demonstrate a tool for probing and visualizing local chemical environments and correlating them to material structure and functionality using advanced multimodal chemical imaging on a combined atomic force microscopy (AFM) and mass spectrometry (MS) system using tip-enhanced photothermal desorption with atmospheric pressure chemical ionization (APCI). We demonstrate enhanced performance metrics of the technique for correlated imaging and point sampling and illustrate the applicability for the analysis of trace chemicals on a human hair, additives in adhesives on paper, and pharmaceuticals samples notoriously difficult to analyze in a vacuum environment. Overall, this approach of correlating local chemical environments to structure and functionality is key to advancing research in many fields ranging from biology, to medicine, to material science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Small Animal IMRT Using 3D-Printed Compensators

Preclinical radiation replicating clinical intensity modulated radiation therapy (IMRT) techniques can provide data translatable to clinical practice. For this work, treatment plans were created for oxygen-guided dose-painting in small animals using inverse-planned IMRT. Spatially varying beam intensities were achieved using 3-dimensional (3D)-printed compensators.

3D PRINTING↗

Electrospraying deposition and characterization of potassium chloride targets for nuclear science measurements

Natural and isotopically enriched KCl targets were prepared using specially formulated KCl solutions, deposited by electrospraying on thin (1.5 μm) gold backings, followed by a short annealing in a preheated (350-450 °C) furnace. Various techniques, such as X-ray fluorescence (XRF), scanning electron microscopy (SEM) imaging, and energy-dispersive X-ray spectroscopy (EDS), were used to characterize the produced targets. A white neutron beam at the Los Alamos Neutron Science Center (LANSCE) facility was also used to verify the estimated atomic percentages of the enriched 40 KCl targets. KCl was deposited relatively uniformly as large particles rather than films on the gold surface. As a result, this method can be broadly extended to make stable targets that are difficult to produce with other methods and more exotic radioactive targets required for research in fundamental sciences and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accuracy versus precision in boosted top tagging with the ATLAS detector

The identification of top quark decays where the top quark has a large momentum transverse to the beam axis, known as top tagging , is a crucial component in many measurements of Standard Model processes and searches for beyond the Standard Model physics at the Large Hadron Collider. Machine learning techniques have improved the performance of top tagging algorithms, but the size of the systematic uncertainties for all proposed algorithms has not been systematically studied. This paper presents the performance of several machine learning based top tagging algorithms on a dataset constructed from simulated proton-proton collision events measured with the ATLAS detector at $\sqrt{s}$ = 13 TeV. The systematic uncertainties associated with these algorithms are estimated through an approximate procedure that is not meant to be used in a physics analysis, but is appropriate for the level of precision required for this study. The most performant algorithms are found to have the largest uncertainties, motivating the development of methods to reduce these uncertainties without compromising performance. To enable such efforts in the wider scientific community, the datasets used in this paper are made publicly available.

47 OTHER INSTRUMENTATION↗

Bayesian optimization algorithms for accelerator physics

Accelerator physics relies on numerical algorithms to solve optimization problems in online accelerator control and tasks such as experimental design and model calibration in simulations. The effectiveness of optimization algorithms in discovering ideal solutions for complex challenges with limited resources often determines the problem complexity these methods can address. The accelerator physics community has recognized the advantages of Bayesian optimization algorithms, which leverage statistical surrogate models of objective functions to effectively address complex optimization challenges, especially in the presence of noise during accelerator operation and in resource-intensive physics simulations. In this review article, we offer a conceptual overview of applying Bayesian optimization techniques toward solving optimization problems in accelerator physics. We begin by providing a straightforward explanation of the essential components that make up Bayesian optimization techniques. We then give an overview of current and previous work applying and modifying these techniques to solve accelerator physics challenges. Finally, we explore practical implementation strategies for Bayesian optimization algorithms to maximize their performance, enabling users to effectively address complex optimization challenges in real-time beam control and accelerator design. Published by the American Physical Society 2024