Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Diffraction and thermal effect of a Bessel-Gaussian laser for Ag nanoparticle deposition

Nanoparticles are known to sinter at much lower temperatures than the corresponding bulk or micro size particles. A laser-assisted sintering process is considered in this study to sinter Ag nanoparticles by dispensing Ag paste onto an indium tin oxide-coated Si substrate. The Gaussian beam of a CO 2 laser source is propagated through axicon and biconvex lenses, and the resulting hollow beam is focused on the Ag paste with a hollow parabolic mirror. A Bessel-Gaussian irradiance distribution is obtained at the focal plane of the parabolic mirror due to the interference of the hollow laser cone. The Fresnel diffraction approximation is considered to determine the phasor of the laser and an analytical approach is implemented to calculate the irradiance distribution of the Bessel-Gaussian beam. This irradiance distribution is utilized as a heat source in a heat conduction model and the temperature distribution is analyzed for thin Ag films formed during the laser sintering of Ag nanoparticles. An analytical expression is obtained for the temperature distribution by solving the heat conduction equation using Fourier transform for finite media. The widths of the deposited Ag lines are predicted from the temperature profiles and the model predictions compare well with the experimental results. The isotherms are found to be geometrically noncongruent with convex and concave tips depending on the locally maximum and minimum irradiances of the Bessel-Gaussian beam, respectively. The convex and concave tips, however, appear in the same isotherm for sufficiently high substrate speed relative to the laser beam.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

AutoFocus: AI/ML-driven real-time wavefront diagnostics to autonomously align and optimize X-ray optics

We present an integrated system that combines advanced wavefront diagnostics with artificial intelligence (AI) to automate and optimize X-ray optics at synchrotron beamlines. This system couples real-time wavefront sensing with AI-driven control algorithms to achieve precise beam alignment, stabilization, and performance optimization. A key feature is the use of multi-fidelity transfer learning, which enables knowledge gained from both real-world beamline optimizations and ultra-realistic digital twin simulations to be effectively applied to in situ optimization. By leveraging multi-objective bayesian optimization, the system continuously refines its performance, reducing optimization time and minimizing the need for manual adjustments. Designed for seamless deployment, it operates with existing beamline hardware and provides an intuitive graphical interface. Initial deployments at the advanced photon source beamlines have demonstrated its ability to enhance beam stability, improve reproducibility, and significantly streamline alignment procedures. This AI-enhanced control framework represents a significant step toward fully autonomous beamline operation in next-generation synchrotron facilities.

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Measuring orbit responses with oscillating trajectories in the Fermilab Linac

Recording changes in beam transverse positions and longitudinal phase reported by Beam Position Monitors (BPMs) in response to a beam deflection by an upstream dipole corrector or RF cavity phase (orbit response) is a powerful tool for analysis of accelerator optics and assisting with machine tuning. In Fermilab Linac, orbit responses were recorded by oscillating the corrector currents and cavity phases in a sinusoidal manner parasitically during regular operation, simultaneously oscillating up to 19 correctors and 7 cavities at distinct frequencies, providing faster, drift-resistant measurements through frequency-domain analysis. This report describes the technique, including error estimations and consistency checks and shows examples of the measurements.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501↗

Achromat Design for Multi-Pulse Test Line

This note describes the design of a 90° achromatic bend on DARHT Axis 2 to support multi-pulse target studies. The achromatic bend consists of two 45° dipole magnets with a focusing quadrupole centered between the dipoles. The optical design of the achromat is described followed by a discussion of the sensitivity to space charge and variations in the beam energy. The preliminary design of the magnets is then described with a description of the electro-mechanical parameters.

42 ENGINEERING↗

Progress in developing a superconducting accelerator for efficient eBeam and X-ray production

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

43 PARTICLE ACCELERATORS↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

Towards a Next Generation Search for Time-Reversal Violation Using Optically Addressable Nuclei in Cryogenic Solids (Final Technical Report, September 2018 - August 2023)

Certain rare pear-shaped nuclei have unmatched sensitivity to new kinds of forces between subatomic particles that are not the same when the arrow of time is reversed. Such forces are believed to be responsible for the near absence of antimatter in the observable Universe. These rare isotopes, some for the first time, will be produced in large numbers at the Facility for Rare Isotope Beams currently under operating at Michigan State University providing an unprecedented opportunity to probe for new physics. In anticipation, we are using abundant isotopes to develop new techniques to manipulate nuclei embedded inside an optically transparent solid at cryogenic temperatures. Implantation into a solid, such as neon and argon, is potentially an effective way to both efficiently capture and repeatedly probe the small number of rare nuclei, such as radium and protactinium. An optically transparent host medium at cryogenic temperatures would allow for the laser manipulation of the nuclei in a thermally quiet and stable environment for a wide variety of guest species such as polar molecules. In such systems, the nuclei are exposed to extraordinarily large electric fields and magnetic field gradients, which significantly amplifies the measurability of certain time-reversal violating effects. The potential sensitivity of this new approach could be at least a few hundred times greater than the current leading experiment which uses stable mercury atoms. We report on the design considerations and preliminary performance of an instrument used to produce and implant molecules into a frozen argon solid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hyperfine spectroscopy and laser cooling of the fermionic isotopes 47 Ti and 49 Ti

Here, we report on magneto-optical trapping of the two fermionic isotopes of atomic titanium, 47 Ti and 49 Ti . Unlike the even mass-number isotopes, which were recently laser cooled, 47 Ti and 49 Ti have nonzero nuclear spins and, consequently, their atomic levels are split by hyperfine structure. Combining and comparing theoretical calculations and atomic beam-spectroscopy measurements, we determine the hyperfine structures and isotope shifts of the 3⁢𝑑 2 ⁢4⁢𝑠 2 𝑎 3 ⁢𝐹 4 → 3⁢𝑑 2 ⁢( 3 𝑃)⁢4⁢𝑠⁢4⁢𝑝⁢( 3 𝑃 𝑜 ) 𝑦 5 ⁢𝐷$^o_4$ optical-pumping transition at optical wavelength 391 nm and the 3⁢𝑑 3 ⁢(4𝐹)⁢4⁢𝑠 𝑎 5 ⁢𝐹 5 → 3⁢𝑑 3 ⁢( 4 𝐹)⁢4⁢𝑝 𝑦 5 ⁢𝐺$^𝑜_6$ laser-cooling transition at wavelength 498 nm. With this information, we produce magneto-optical traps of both 47 Ti and 49 Ti by applying two additional tones of light to repump atoms to the maximum-spin states on the laser-cooling transition. Directly loading from the atomic flux of a titanium sublimation pump, we produce 47 Ti and 49 Ti traps with 731(190) and 1142(240) atoms, and with lifetimes of 330⁢(15) and 310⁢(8)⁢ ms, respectively.

atomic spectra↗

Collimation Systems for the PSR

This note provides a review of collimator systems being used or considered in high-intensity proton accelerators like SNS, J-PARC, LHC, and PIP-II. These facilities use collimators to remove beam halo, restrict transverse size and momentum in the beam to constrain beam losses around collimators and minimize beam losses downstream, particularly losses arising from particles missing the design location at the stripping foil when injected into the proton storage ring. Collimators are placed either in the transport injection lines (single-pass collimators) or in the rings (multi-pass collimators). Collimators in the transport line are placed around stripping foils in H- accelerators, allowing the beamline optics to get rid of the unstripped protons into well localized absorbers. Rings and proton accelerators mostly rely on tungsten scrapers and collimators in a multi-stage configuration to clean the scattered beam particles mainly responsible for heavy losses at high energies. Placement of the collimators is carefully chosen in terms of the right phase advance to maximize the collimating efficiency, whether the collimation is intended to match an injection stripping foil or a downstream acceptance. Collimation systems are designed with the specific concerns of each facility in mind, although all of them prioritize the minimization of activation due to beam losses to enable hands-on access during maintenance periods. At LANSCE, there are no high-energy collimators, although pairs of horizontal and vertical jaws are routinely used in the LEBT to clean and control the transverse beam profile delivered downstream. This report will help in understanding, together with the beam dynamics simulations, which collimation schemes would be most effective for the PSR upgrade. For example, SNS designed off-momentum collimators to be placed in a 90° arc bend, a high-dispersion region in the beam injection line, very similar to the bend at Line D in LANSCE. This system was very effective at minimizing losses during injection into the SNS accumulator ring and is being re-designed for future operation.

43 PARTICLE ACCELERATORS↗

Hybridization and deconfinement in colloidal quantum dot molecules

The structural, electronic, and optical properties of CdSe/CdS core–shell colloidal quantum dot molecules, a new class of coupled quantum dot dimers, are explored using atomistic approaches. Unlike the case of dimers grown by molecular beam epitaxy, simulated strain profile maps of free-standing colloidal dimers show negligible additional strain resulting from the attachment. Further, the electronic properties of the relaxed dimers are described within a semiempirical pseudopotential model combined with the Bethe–Salpeter equation within the static screening approximation to account for electron–hole correlations. The interplay of strain, hybridization (tunneling splitting), quantum confinement, and electron–hole binding energies on the optical properties is analyzed and discussed. The effects of the dimensions of the neck connecting the two quantum dot building blocks, as well as the shell thickness, are studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a robust damage analysis scheme at the National Ignition Facility

The onset of laser-induced damage in optical materials is a limiting factor in the design and operation of most high-energy laser systems. As such, significant effort has been dedicated to developing laser damage testing protocols and procedures to inform laser system design and operating limits. These tests typically rely on multiple laser exposures for statistical validation. Historically, small beam single fluence (N / 1) or ramped fluence (R / 1) tests have been used to quantify the “laser-induced damage threshold” of a material. However, due to various distributions in damage precursor populations, the laser fluence at which damage occurs for a given sample varies with beam size and is therefore better described as the onset of observed damage for that testing geometry. In conclusion, we document the development of irradiation, measurement, and analysis methods for damage testing resulting in damage initiation density as a function of incident fluence or ρ(ϕ) which is suitable for both small and large beam area testing and more conducive to extrapolating from one to the other.

Beam diameter↗

Improved filters for angular filter refractometry

Angular filter refractometry is an optical diagnostic that measures the absolute contours of a line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce corresponding alternating light and dark regions in the image plane. Identifying transitions between these regions with specific zones on the angular filter (AF) allows the line-integrated density to be determined, but the sign of the density gradient at each transition is degenerate and must be broken using other information about the object plasma. Additional features from diffraction in the filter plane often complicate data analysis. Here, in this paper, we present an improved AF design that uses a stochastic pixel pattern with a sinusoidal radial profile to minimize unwanted diffraction effects in the image caused by the sharp edges of the filter bands. We also present a technique in which a pair of AFs with different patterns on two branches of the same probe beam can be used to break the density gradient degeneracy. Both techniques are demonstrated using a synthetic diagnostic and data collected on the OMEGA EP (extended performance) laser.

47 OTHER INSTRUMENTATION↗

DXRD : a user-friendly suite of two- and multiple-beam dynamical X-ray diffraction programs

The DXRD program suite consisting of a series of dynamical theory programs is introduced for computing dynamical X-ray diffraction from single crystals. Its interactive graphical user interfaces (GUIs) allow general users to make complicated calculations with minimal effort. It can calculate plane-wave Darwin curves of single crystals (or multiple crystals) for both the Bragg and Laue cases, including grazing-incidence diffraction and backward diffraction (with Bragg angles approaching 90°). It is also capable of simulating rocking curves for divergent incident X-ray beams with finite bandwidths. A unique feature of DXRD is that it provides a convenient GUI-based multiple-beam diffraction program that can accurately compute arbitrary N-beam diffraction of any geometry using a universal 4N × 4N matrix method. DXRD also provides a mapping program for plotting all the multiple-beam diffraction lines (monochromator glitches) in the azimuth–energy coordinate system. All these functions make DXRD a convenient and powerful software tool for designing crystal-based synchrotron/X-ray optics (monochromators, analyzers, polarizers, phase plates etc.) and for crystal characterization, X-ray spectroscopy and X-ray diffraction teaching.

Bragg reflection↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

RECENT RESULTS AND OPPORTUNITIES AT THE IOTA FACILITY

The Integrable Optics Test Accelerator (IOTA) was recently commissioned as part of the Fermilab Accelerator Science and Technology (FAST) facility. The IOTA ring was briefly operated with electrons at 47 MeV followed by a 6-months run with 100 MeV electrons. The main goal of the first runwas to study beam dynamics in the integrable lattices with elliptical nonlinear magnets and in the quasi-integrable case with profiled octupole channel. The flexibility of the IOTA ring allowed a wide range of complementary studies, such as experiments with a single electron; studies of fluctuations in undulator radiation and operation with low emittance beams. Over the next year the proton injector will be installed and two runs carried out. One run will be dedicated to the refinement of nonlinear experiments and another will be dedicated to the proof-of-principle demonstration of Optical Stochastic Cooling.

43 PARTICLE ACCELERATORS↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗