Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “baseline estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Adapting ecological risk valuation for natural resource damage assessment in water pollution

Highlights: • An approach is proposed to assess water damages from pollution incident. • Sewage treatment cost is analyzed to estimate the value of water quality damage. • DEA is employed to classify samples of sewage plants based on their efficiency. • The relation between treatment cost and the decrease of COCs is determined. • The range of damage cost is determined based on efficient and inefficient samples. Ecological risk assessment can address requirements of natural resource damage assessment by quantifying the magnitude of possible damages to the ecosystem. This paper investigates an approach to assess water damages from pollution incident on the basis of concentrations of contaminants. The baseline of water pollution is determined with not-to-exceed concentration of contaminants required by water quality standards. The values of damage cost to water quality are estimated through sewage treatment cost. To get a reliable estimate of treatment cost, DEA is employed to classify samples of sewage plants based on their efficiency of sewage treatment. And exponential fitting is adopted to determine the relation between treatment cost and the decrease of COCs. The range of damage costs is determined through the fitting curves respectively based on efficient and inefficient samples.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radio Interferometric Determination of Source Positions, Intercontinental Baselines, and Earth Orientation with Deep Space Network Antennas: 1971 to 1980

Approximately 2400 observations of extragalactic radio sources were made between August 1971 and February 1980 during 48 separate sessions. These consisted of 259 delay rate observations at 2.3 GHz (S-band), 796 delay and delay rate observations at either S-band of 8.3 GHz (X-band) and 1325 delay and delay rate observations recorded simultaneously at both S- and X-band. A single multiparameter fit has been applied to the observed values of delay and delay rate to extract astrometric and geophysical parameters from this decade-long sequence. The fit produced estimates of 784 parameters, including station locations, radio source positions, polar motion, Universal Time, the precession constant, and solid earth tides. The a priori model included gravitational bending, the 1980 IAU nutation series, the 1976 IAU expressions for Greenwich mean sidereal time and precession, BIH estimates of Universal Time and polar motion, and monthly mean values for zenith troposphere delay. The rms residuals were 0.52 nsec for delay and 0.30 psec/sec for delay rate. Intercontinental baseline lengths were determined with formal uncertainties of 5 to 10 cm. Universal Time and polar motion were measured at 49 epochs, with formal uncertainties (for the more recent data) of 0.5 msec for UT1 and 6 and 2 mas, respectively, for the X and Y components of polar motion.

Thomas, J. B.↗

The NOνA experiment, the first 12 months of commissioning, operations and physics data

The NOνA experiment is a long baseline neutrino experiment designed to make precision measurements of the oscillation probabilities for ν{sub µ} → ν{sub e} and ν{sub µ} → ν{sub µ} for both neutrinos and anti-neutrinos. These measurements will provide new information on the neutrino mass hierarchy, improve our knowledge of whether θ{sub 23} is non-maximal and possibility provide information on the CP violating phase δ{sub CP} of the PMNS neutrino mixing matrix. We present the observations of the first neutrino event in the NOνA far and near detectors along with data obtained during the first year of detector commissioning and operations. We use the data to demonstrate the detector’s ability to identify electron and muon neutrino events and to reject cosmic ray induced backgrounds at a level of 4 × 10{sup 7}:1. New estimates for the signal and background sensitivities of the NOνA experiment during the first year of full detector running are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vegetation Height Estimate in Rice Fields Using Single Polarization TanDEM-X Science Phase Data

This study presents the retrieval of rice paddy height using single polarization (single-pol) interferometric SAR (InSAR) data by means of model-based height inversion without an external DEM. A total of eight TanDEM-X (TDX) scenes were used and the TDX images were; acquired using a large cross-track baseline configuration during the TDX Science Phase (June–August 2015). A single-pol inversion approach for a flooded rice field is proposed and evaluated over the Buan test site in South Korea. A novel approach is adopted for the estimation of the ground (i.e., water level) interferometric phase within a flooded rice paddy from TDX data acquired during a period of early rice growth. It is consequently possible to apply the model-based inversion algorithm to the single-pol InSAR data. Rice height maps during the rice growth cycle presented and validated by field measurements. The results demonstrated the high performance of the inversion with a correlation coefficient of 0.78 and an RMSE of 0.10 m. The proposed methodology will be useful to monitor rice plants and to predict a gross rice yield, along with dual and fully polarimetric interferometric SAR data.

Lee, Seung-Kuk↗

Assessing variation in faecal glucocorticoid concentrations in gray whales exposed to anthropogenic stressors

Understanding how individual animals respond to stressors behaviourally and physiologically is a critical step towards quantifying long-term population consequences and informing management efforts. Glucocorticoid (GC) metabolite accumulation in various matrices provides an integrated measure of adrenal activation in baleen whales and could thus be used to investigate physiological changes following exposure to stressors. In this study, we measured GC concentrations in faecal samples of Pacific Coast Feeding Group (PCFG) gray whales (Eschrichtius robustus) collected over seven consecutive years to assess the association between GC content and metrics of exposure to sound levels and vessel traffic at different temporal scales, while controlling for contextual variables such as sex, reproductive status, age, body condition, year, time of year and location. We develop a Bayesian Generalized Additive Modelling approach that accommodates the many complexities of these data, including non-linear variation in hormone concentrations, missing covariate values, repeated samples, sampling variability and some hormone concentrations below the limit of detection. Estimated relationships showed large variability, but emerging patterns indicate a strong context-dependency of physiological variation, depending on sex, body condition and proximity to a port. Our results highlight the need to control for baseline hormone variation related to context, which otherwise can obscure the functional relationship between faecal GCs and stressor exposure. Therefore, extensive data collection to determine sources of baseline variation in well-studied populations, such as PCFG gray whales, could shed light on cetacean stress physiology and be used to extend applicability to less-well-studied taxa. GC analyses may offer greatest utility when employed as part of a suite of markers that, in aggregate, provide a multivariate measure of physiological status, better informing estimates of individuals’ health and ultimately the consequences of anthropogenic stressors on populations.

59 BASIC BIOLOGICAL SCIENCES↗

Exploration of a Potential Desirability of Outcome Ranking Endpoint for Complicated Intra-Abdominal Infections Using 9 Registrational Trials for Antibacterial Drugs

Abstract Background Desirability of outcome ranking (DOOR) is a novel approach to clinical trial design that incorporates safety and efficacy assessments into an ordinal ranking system to evaluate overall outcomes of clinical trial participants. Here, we derived and applied a disease-specific DOOR endpoint to registrational trials for complicated intra-abdominal infection (cIAI). Methods Initially, we applied an a priori DOOR prototype to electronic patient-level data from 9 phase 3 noninferiority trials for cIAI submitted to the US Food and Drug Administration between 2005 and 2019. We derived a cIAI-specific DOOR endpoint based on clinically meaningful events that trial participants experienced. Next, we applied the cIAI-specific DOOR endpoint to the same datasets and, for each trial, estimated the probability that a participant assigned to the study treatment would have a more desirable DOOR or component outcome than if assigned to the comparator. Results Three key findings informed the cIAI-specific DOOR endpoint: (1) a significant proportion of participants underwent additional surgical procedures related to their baseline infection; (2) infectious complications of cIAI were diverse; and (3) participants with worse outcomes experienced more infectious complications, more serious adverse events, and underwent more procedures. DOOR distributions between treatment arms were similar in all trials. DOOR probability estimates ranged from 47.4% to 50.3% and were not significantly different. Component analyses depicted risk-benefit assessments of study treatment versus comparator. Conclusions We designed and evaluated a potential DOOR endpoint for cIAI trials to further characterize overall clinical experiences of participants. Similar data-driven approaches can be utilized to create other infectious disease–specific DOOR endpoints.

Immunology↗

Energy Intensity Baselining and Tracking Guidance

Each company joining the U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) commits to establishing an energy consumption and energy intensity (EI) baseline and to tracking its energy performance over a 10-year period against that baseline. The baseline must reflect a company’s energy consumption over a 12-month period, covering all its U.S.-based operations. Energy consumption is calculated by fuel type in terms of primary energy (also known as source energy). EI is broadly defined as the amount of energy consumed per unit of output produced. For this guidance document and for the program, the term energy performance represents an evaluation of a facility’s capacity to use energy efficiently. Metrics used to assess a facility’s energy performance can include EI, energy consumption, improvements in EI, etc. Establishing an energy baseline and tracking system is a critical first step in effectively managing energy use. Developing a baseline can help a company understand energy use within the corporation and give it a point of comparison to evaluate future efforts to improve energy performance. It can also support efforts to validate a company’s energy management activities, improve comparative analyses when using benchmarks, and help in predicting future energy needs. In addition, a company that normalizes its performance data can determine highly defensible measures of energy savings generated through implemented energy efficiency projects. Establishing a baseline and tracking energy performance is also a requirement for ISO 50001 certification. Although basic energy data can be collected through utility bills, most manufacturers will have to perform additional analyses to develop accurate and robust energy baselines and tracking systems. Energy is consumed in many ways within the manufacturing sector and can come from multiple sources. Energy is sometimes generated and sold to other parties or captured and reused on-site. External events can exert a significant impact on a facility or company’s energy use independent of any purposeful efforts to improve energy efficiency. Operational changes, such as production shifts—which may be inevitable for some companies over the 10-year period covered by the program—can also make a big difference in energy use. Since Better Plants asks companies to account for all their U.S.-based operations, mergers, acquisitions, and divestitures can also have significant implications for a company’s energy metrics. This document aims to demystify the sometimes complex baselining process. It devotes special attention to the task of normalizing and adjusting energy consumption to account for external factors, such as weather and production changes. A key recommendation is that companies use regression analysis to normalize their energy consumption data whenever possible. Regression analysis is a statistical technique that estimates the dependence of a variable (i.e., energy use in the context of Better Plants) on one or more independent variables such as ambient temperature, while controlling for the influence of other variables at the same time. A properly developed regression analysis can provide a reliable estimate of energy savings resulting from energy improvement strategies and projects by accounting for the effects of variables such as annual production levels and weather. DOE has developed a companion Energy Performance Indicator software tool (EnPI) to simplify the baselining process. This tool can run regression models, calculate changes in EI at the facility level, and automatically compile facility-level data into a corporate-wide metric. Note that although the relevant equations used to calculate EI are provided in this document, the EnPI tool will automatically perform most calculations for the user. Additionally, Better Plants Partners (Partners) can call on their Technical Account Manager (TAM) to help them establish a baseline and assist with the necessary calculations to track progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncertainty quantification of CO₂ saturation estimated from electrical resistance tomography data at the Cranfield site

A parametric bootstrap approach is presented for uncertainty quantification (UQ) of CO₂ saturation derived from electrical resistance tomography (ERT) data collected at the Cranfield, Mississippi (USA) carbon sequestration site. There are many sources of uncertainty in ERT-derived CO₂ saturation, but we focus on how the ERT observation errors propagate to the estimated CO₂ saturation in a nonlinear inversion process. Our UQ approach consists of three steps. We first estimated the observational errors from a large number of reciprocal ERT measurements. The second step was to invert the pre-injection baseline data and the resulting resistivity tomograph was used as the prior information for nonlinear inversion of time-lapse data. We assigned a 3% random noise to the baseline model. Finally, we used a parametric bootstrap method to obtain bootstrap CO₂ saturation samples by deterministically solving a nonlinear inverse problem many times with resampled data and resampled baseline models. Then the mean and standard deviation of CO₂ saturation were calculated from the bootstrap samples. We found that the maximum standard deviation of CO₂ saturation was around 6% with a corresponding maximum saturation of 30% for a data set collected 100 days after injection began. There was no apparent spatial correlation between the mean and standard deviation of CO₂ saturation but the standard deviation values increased with time as the saturation increased. The uncertainty in CO₂ saturation also depends on the ERT reciprocal error threshold used to identify and remove noisy data and inversion constraints such as temporal roughness. Five hundred realizations requiring 3.5 h on a single 12-core node were needed for the nonlinear Monte Carlo inversion to arrive at stationary variances while the Markov Chain Monte Carlo (MCMC) stochastic inverse approach may expend days for a global search. This indicates that UQ of 2D or 3D ERT inverse problems can be performed on a laptop or desktop PC.

58 GEOSCIENCES↗

Determinants of the reliability of ultrasound tomography sound speed estimates as a surrogate for volumetric breast density

Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (two scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density.

60 APPLIED LIFE SCIENCES↗

Market Opportunities for Deployable Wind Systems for Defense and Disaster Response

This report is the first public deliverable from the Defense and Disaster Deployable Turbine project, funded through the distributed wind portfolio of the U.S. Department of Energy Wind Energy Technologies Office. The objective of the project is to explore the opportunity for deployable turbine technologies to meet the operational energy needs of the U.S. military and global disaster response efforts. This report provides a market assessment that was conducted over a year using public reports, presentations at topical conferences, and direct stakeholder engagement interviews with both military and industry representatives. It begins with the high- level operational energy strategy of the Department of Defense that provides the context for alternatives to diesel fuel to meet energy needs. The report then provides an estimate of the energy use of the military in missions where a deployable turbine could potentially serve as an alternative to the baseline use of diesel fuel in generators to provide electricity in remote locations. An overview of domestic and international disaster response is provided with a focus on the role of the military in providing energy to those events. Finally, the report summarizes the technical considerations that would enable a deployable turbine to meet military and disaster response energy needs including the global wind resource, the technical design of the turbine, and the operational constraints of various military missions.

17 WIND ENERGY↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Demonstration of Mer-Cure Technology for Enhanced Mercury Control

Alstom Power Inc. has completed a DOE/NETL-sponsored program (under DOE Cooperative Agreement No. De-FC26-07NT42776) to demonstrate Mer-Cure{trademark}, one of Alstom's mercury control technologies for coal-fired boilers. The Mer-Cure{trademark}system utilizes a small amount of Mer-Clean{trademark} sorbent that is injected into the flue gas stream for oxidation and adsorption of gaseous mercury. Mer-Clean{trademark} sorbents are carbon-based and prepared with chemical additives that promote oxidation and capture of mercury. The Mer-Cure{trademark} system is unique in that the sorbent is injected into an environment where the mercury capture kinetics is accelerated. The full-scale demonstration program originally included test campaigns at two host sites: LCRA's 480-MW{sub e} Fayette Unit No.3 and Reliant Energy's 190-MW{sub e} Shawville Unit No.3. The only demonstration tests actually done were the short-term tests at LCRA due to budget constraints. This report gives a summary of the demonstration testing at Fayette Unit No.3. The goals for this Mercury Round 3 program, established by DOE/NETL under the original solicitation, were to reduce the uncontrolled mercury emissions by 90% at a cost significantly less than 50% of the previous target of $60,000/lb mercury removed. The results indicated that Mer-Cure{trademark} technology could achieve mercury removal of 90% based on uncontrolled stack emissions. The estimated costs for 90% mercury control, at a sorbent cost of $0.75 to $2.00/lb respectively, were $13,400 to $18,700/lb Hg removed. In summary, the results from demonstration testing show that the goals established by DOE/NETL were met during this test program. The goal of 90% mercury reduction was achieved. Estimated mercury removal costs were 69-78% lower than the benchmark of $60,000/lb mercury removed, significantly less than 50% of the baseline removal cost.

01 COAL, LIGNITE, AND PEAT↗

A giant Lyα nebula in the core of an x-ray cluster at z = 1.99: implications for early energy injection

We present the discovery of a giant ≳100 kpc Lyα nebula detected in the core of the X-ray emitting cluster CL J1449+0856 at z = 1.99 through Keck/LRIS narrow-band imaging. This detection extends the known relation between Lyα nebulae and overdense regions of the universe to the dense core of a 5–7 × 10{sup 13} M {sub ⊙} cluster. The most plausible candidates to power the nebula are two Chandra-detected AGN host cluster members, while cooling from the X-ray phase and cosmological cold flows are disfavored primarily because of the high Lyα to X-ray luminosity ratio (L{sub Lyα}/L{sub X}≈0.3, ≳10–1000 times higher than in local cool-core clusters) and by current modeling. Given the physical conditions of the Lyα-emitting gas and the possible interplay with the X-ray phase, we argue that the Lyα nebula would be short-lived (≲10 Myr) if not continuously replenished with cold gas at a rate of ≳1000 M {sub ⊙} yr{sup −1}. We investigate the possibility that cluster galaxies supply the required gas through outflows and we show that their total mass outflow rate matches the replenishment necessary to sustain the nebula. This scenario directly implies the extraction of energy from galaxies and its deposition in the surrounding intracluster medium (ICM), as required to explain the thermodynamic properties of local clusters. We estimate an energy injection of the order of ≈2 keV per particle in the ICM over a 2 Gyr interval. In our baseline calculation, AGNs provide up to 85% of the injected energy and two-thirds of the mass, while the rest is supplied by supernovae-driven winds.

79 ASTRONOMY AND ASTROPHYSICS↗

UrbanPop 2019 Baseline Population

A synthetic residential baseline population for the United States at the census block group level based on the American Community Survey 2015-2019 5-Year Estimates and described by residential, demographic, social, economic, student, mobility, and housing characteristics.

Tuccillo, Joe [ORNL] (ORCID:0000000259300943)↗

Spacecraft drag-free technology development: On-board estimation and control synthesis

Estimation and control methods for a Drag-Free spacecraft are discussed. The functional and analytical synthesis of on-board estimators and controllers for an integrated attitude and translation control system is represented. The framework for detail definition and design of the baseline drag-free system is created. The techniques for solution of self-gravity and electrostatic charging problems are applicable generally, as is the control system development.

Key, R. W.↗

Application of an optimized winglet configuration to an advanced commercial transport

The design is presented of an aircraft which employs an integrated wing and winglet lift system. Comparison was made with a conventional baseline configuration employing a high-aspect-ratio supercritical wing. An optimized wing-winglet combination was selected from four proposed configurations for which aerodynamic, structural, and weight characteristics were evaluated. Each candidate wing-winglet configuration was constrained to the same induced drag coefficient as the baseline aircraft. The selected wing-winglet configuration was resized for a specific medium-range mission requirement, and operating costs were estimated for a typical mission. Study results indicated that the wing-winglet aircraft was lighter and could complete the specified mission at less cost than the conventional wing aircraft. These indications were sensitive to the impact of flutter characteristics and, to a lesser extent, to the performance of the high-lift system. Further study in these areas is recommended to reduce uncertainty in future development.

Shollenberger, C. A.↗

Low concentration ratio solar array for low Earth orbit multi-100 kW application

An ongoing preliminary design effort directed toward a low-concentration-ratio photovoltaic array system based on 1984 technology and capable of delivering multi-hundred kilowatts (300 kW to 1000 kW range) in low earth orbit is described. The array system consists of two or more array modules each capable of delivering between 80 kW to 172 kW using silicon solar cells or gallium arsenide solar cells respectively. The array module deployed area is 1320 square meters and consists of 4356 pryamidal concentrator elements. The module, when stowed in the Space Shuttle's payload bay, has a stowage volume of a cube with 3.24 meters on a side. The concentrator elements are sized for a geometric concentration ratio (GCR) of six with an aperture area of 0.5 meters x 0.5 meters. The structural analysis and design trades leading to the baseline design are discussed. The configuration, as well as optical, thermal and electrical performance analyses that support the design and overall performance estimates for the array are described.

Nalbandian, S. J.↗