Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “annular”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Propellant Mass Gauging in a Spherical Tank under Micro-Gravity Conditions Using Capacitance Plate Arrays and Machine Learning

Propellant mass gauging under micro-gravity conditions is a challenging task due to the unpredictable position and shape of the fuel body inside the tank. Micro-gravity conditions are common for orbiting satellites and rockets that operate on limited fuel supplies. Capacitance sensors have been investigated for this task in recent years; however, the effect of various positions and shapes of the fuel body is not analyzed in detail. In this paper, we investigate this with various fill types, such as annular, core-annular, and stratified fills at different positions. We compare the performance among several curve-fitting-based approaches and a machine-learning-based approach, the latter of which offers superior performance in estimating the fuel content.

47 OTHER INSTRUMENTATION↗

Studies of the Core Conditions of the Earth and Super-Earths Using Intense Ion Beams at FAIR

Using detailed numerical simulations, we present the design of an experiment that will generate samples of iron under extreme conditions of density and pressure believed to exist in the interior of the Earth and interior of extrasolar Earth-like planets. In the proposed experiment design, an intense uranium beam is used to implode a multilayered cylindrical target that consists of a thin Fe cylinder enclosed in a thick massive W shell. Such intense uranium beams will be available at the heavy-ion synchrotron, SIS100, at the Facility for Antiprotons and Ion Research (FAIR), at Darmstadt, which is under construction and will become operational in the next few years. It is expected that the beam intensity will increase gradually over a couple of years to its maximum design value. Therefore, in our studies, we have considered a wide range of beam parameters, from the initial beam intensity (“Day One”) to the maximum specified value. It is also worth noting that two different focal spot geometries have been used. In one case, a circular focal spot with a Gaussian transverse intensity distribution is considered, whereas in the other case, an annular focal spot is used. With these two beam geometries, one can access different parts of the Fe phase diagram. For example, heating the sample with a circular focal spot generates a hot liquid state, while an annular focal spot can produce a highly compressed liquid or a highly compressed solid phase depending on the beam intensity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gas turbine combustor insensitive to compressor outlet distortion

Short-length annular combustor for turbojet engines eliminates change of exit temperature profile. Individual scoops of full annular height control air distribution so that shifts in the radial velocity profile of air entering the combustor will not affect combustion process or alter exit temperature profile.

Humenik, F.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately-known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is on the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream pressure. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

The structure of jet turbulence producing jet noise.

Measurements are presented that characterize the structure of the jet in both the core and the surrounding annular mixing region. Experiments were carried out in a 1.5-inch diameter subsonic jet at Mach numbers of 0.3, 0.5, and 0.7. The growth of pressure fluctuations within the core from the jet outlet to the end of the jet core was traced through the examination of spectral results. The spectra in the jet core exhibited a peak whose frequency scaled with the jet velocity and the jet diameter which is related to a characteristic dimension of the mixing process. A digital data reduction program was used to calculate the auto- and cross-correlations of axial velocity fluctuations. In the core the cross-correlations were nearly constant in the space-time plane indicating a traveling pressure wave, while in the annular mixing region the cross-correlations exhibited the usual decay in the space-time plane characteristic of convected turbulence.

Wooldridge, C. E.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of the total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is of the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream surface. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Subcooled forced convection boiling of trichlorotrifluoroethane

Experimental heat-transfer data were obtained for the forced-convection boiling of trichlorotrifluoroethane (R-113 or Freon-113) in a vertical annular test annular test section. The 97 data points obtained covered heat transfer by forced convection, local boiling, and fully-developed boiling. Correlating methods were obtained which accurately predicted the heat flux as a function of wall superheat (boiling curve) over the range of parameters studied.

Dougall, R. S.↗

Piston manometer as an absolute standard for vacuum-gage calibration in the range 2 to 500 millitorr

A thin disk is suspended, with very small annular clearance, in a cylindrical opening in the base plate of a calibration chamber. A continuous flow of calibration gas passes through the chamber and annular opening to a downstream high vacuum pump. The ratio of pressures on the two faces of the disk is very large, so that the upstream pressure is substantially equal to net force on the disk divided by disk area. This force is measured with a dynamometer that is calibrated in place with dead weights. A probable error of + or - (0.2 millitorr plus 0.2 percent) is attainable when downstream pressure is known to 10 percent.

Warshawsky, I.↗

Study of the collector/heat pipe cooled externally configured thermionic diode

A collector/heat pipe cooled, externally configured (heated) thermionic diode module was designed for use in a laboratory test to demonstrate the applicability of this concept as the fuel element/converter module of an in-core thermionic electric power source. During the course of the program, this module evolved from a simple experimental mock-up into an advanced unit which was more reactor prototypical. Detailed analysis of all diode components led to their engineering design, fabrication, and assembly, with the exception of the collector/heat pipe. While several designs of high power annular wicked heat pipes were fabricated and tested, each exhibited unexpected performance difficulties. It was concluded that the basic cause of these problems was the formation of crud which interfered with the liquid flow in the annular passage of the evaporator region.

Source record↗

Turnstile slot antenna

A turnstile slot antenna is disclosed, the antenna being for and integral with a spacecraft having a substantially cylindrical body portion. The antenna comprises a circumferential slot about the periphery of the spacecraft body portion with an annular wave guide cavity defining a radial transmission line disposed within the spacecraft body portion behind and in communication with the circumferential slot. Feed stubs and associated transmission apparatus are provided to excite the annular cavity in quadrature phase such that an omnidirectional, circularly polarized, rotating radiation pattern is generated. The antenna of the instant invention has utility both as a transmitting and receiving device, and ensures continuous telemetry and command coverage with the spacecraft.

Munson, R. E.↗

Acoustic theory of axisymmetric multisectioned ducts

Equations are developed for the acoustic field in a duct system which is made up of a number of connected circular and annular ducts. These equations are suitable for finding the acoustic field inside of and radiated from an aircraft turbofan engine. Acoustic modes are used as generalized coordinates in order to develop a set of matrix equations for the acoustic field. Equations for these modes are given for circular and annular ducts with uniform flow. Modal source equations are derived for point acoustic sources. General equations for mode transmission and reflection are developed and detailed equations are derived for ducts with multiple sections of acoustic treatment and for ducts with circumferential splitter rings. The general theory is applied to the special case of a uniform area circular duct with multisection liners and it is shown that the mode reflection effects are proportional to differences of the acoustic admittances of adjacent liners. A numerical example is given which shows that multisection liners may provide greater noise suppression than uniform liners.

Zorumski, W. E.↗

Spinning mode sound propagation in ducts with acoustic treatment

A detailed theoretical study of the acoustic propagation of spinning modes in acoustically treated open circular ducts is described. The suppressor with splitter rings was modeled by using the rectangular approximation to the annular duct. The theoretical models were used to determine optimum impedance and maximum attenuation for several spinning lobe numbers from 0 to 50. Some interesting results of the analysis are that for circular ducts the maximum possible attenuation and the optimum wall impedance are strong functions of the lobe number. For annular ducts the attenuation and optimum wall impedance are insensitive to the spinning lobe number for well cut-on modes. The above results help explain why suppressors with splitter rings were quite effective in spite of the lack of detailed information on the noise source modal structure.

Rice, E. J.↗

The distance of BL Lacertae

Spectrophotometric observations of the extended object around BL Lacertae have been conducted from August 1969 to October 1973 using circular apertures of various diameters as well as an annular aperture with an outer diameter of 10-in. and an inner obscuring disk of 5 in. All observations were carried out with a multichannel spectrometer attached to the 200-in. Hale telescope. The annular-aperture spectrum shows the absorption lines normally seen in spectra of ordinary giant galaxies; these lines yield a redshift (z) equal to 0.07. The central source shows a power law spectrum with the exponent (alpha) equal to -1.55. The underlying galaxy energy distribution is consistent with that of a normal giant elliptical galaxy. If a Hubble constant of 60 km/sec per Mpc is used, the absolute visual magnitude of the galaxy is -22.9, and the distance is 350 Mpc.

Oke, J. B.↗

Spinning mode sound propagation in ducts with acoustic treatment

Recent acoustic data show larger noise attenuations than predicted for acoustically treated aircraft engine inlets without splitter rings. A theoretical study of the acoustic propagation of spinning modes in acoustically treated open circular ducts is presented, and a suppressor with splitter rings was modeled by using the rectangular approximation to the annular duct. Theoretical models were used to determine optimum impedance and maximum attenuation for several spinning lobe numbers from 0 to 50. Results of the analysis indicate that for circular ducts the maximum possible attenuation and the optimum wall impedance are strong functions of the lobe number, and for annular ducts the attenuation and optimum wall impedance are insensitive to the spinning lobe number for well cut-on modes. These results explain why suppressors with splitter rings were quite effective in spite of the lack of detailed information on the noise source modal structure. Conversely, effective use of outer wall treatment alone will require expanded knowledge of the noise source structure. Approximate solutions are presented to help interpret the more exact theoretical results.

Rice, E. J.↗

Experimental clean combustor program, phase 1

Full annular versions of advanced combustor designs, sized to fit within the CF6-50 engine, were defined, manufactured, and tested at high pressure conditions. Configurations were screened, and significant reductions in CO, HC, and NOx emissions levels were achieved with two of these advanced combustor design concepts. Emissions and performance data at a typical AST cruise condition were also obtained along with combustor noise data as a part of an addendum to the basic program. The two promising combustor design approaches evolved in these efforts were the Double Annular Combustor and the Radial/Axial Combustor. With versions of these two basic combustor designs, CO and HC emissions levels at or near the target levels were obtained. Although the low target NOx emissions level was not obtained with these two advanced combustor designs, significant reductions were relative to the NOx levels of current technology combustors. Smoke emission levels below the target value were obtained.

Bahr, D. W.↗

Experimental clean combustor program noise measurement addendum, phase 1

The test results of combustor noise measurements taken with waveguide probes are presented. Waveguide probes were shown to be a viable measurement technique for determining high sound pressure level broadband noise. A total of six full-scale annular combustors were tested and included the three advanced combustor designs: swirl-can, radial/axial, and double annular.

Emmerling, J. J.↗

A photographic study of flow condensation in 1-g and zero-gravity environments

The test articles investigated include two full-scale radiator/condenser panels and a system of three parallel-connected fused quartz tubes. Testing was performed initially on the ground, with both horizontal and inclined flow passage orientations, and additionally in an aircraft flying 0-g trajectories. The photographic observations were made with two high speed cameras and a low speed camera. The flow regimes observed are compared with those predicted by the Baker chart (1954). The Baker chart is well in accord with physical reality in the annular flow region. However, a stratified-annular flow regime observed has no counterpart in the Baker categorization.

Keshock, E. G.↗