Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Assessing the system value of optimal load shifting

We analyze a competitive electricity market, where consumers exhibit optimal load shifting behavior to maximize utility and producers/suppliers maximize their profit under supply capacity constraints. The associated computationally tractable formulation can be used to inform market design or policy analysis in the context of increasing availability of the smart grid technologies that enable optimal load shifting. Through analytic and numeric assessment of the model, we assess the equilibrium value of optimal electricity load shifting, including how the value changes as more electricity consumers adopt associated technologies. For our illustrative numerical case, derived from the Current Trends scenario of the ERCOT Long Term System Assessment, the average energy arbitrage value per ERCOT customer of optimal load shifting technologies is estimated to be $3 for the 2031 scenario year. We assess the sensitivity of this result to the flexibility of load, along with its relationship to the deployment of renewables. Finally, the model presented can also be a starting point for designing system operation infrastructure that communicates with the devices that schedule loads in response to price signals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TU-C-BRE-05: Clinical Implications of AAA Commissioning Errors and Ability of Common Commissioning ' Credentialing Procedures to Detect Them

Purpose: To test the ability of the TG-119 commissioning process and RPC credentialing to detect errors in the commissioning process for a commercial Treatment Planning System (TPS). Methods: We introduced commissioning errors into the commissioning process for the Anisotropic Analytical Algorithm (AAA) within the Eclipse TPS. We included errors in Dosimetric Leaf Gap (DLG), electron contamination, flattening filter material, and beam profile measurement with an inappropriately large farmer chamber (simulated using sliding window smoothing of profiles). We then evaluated the clinical impact of these errors on clinical intensity modulated radiation therapy (IMRT) plans (head and neck, low and intermediate risk prostate, mesothelioma, and scalp) by looking at PTV D99, and mean and max OAR dose. Finally, for errors with substantial clinical impact we determined sensitivity of the RPC IMRT film analysis at the midpoint between PTV and OAR using a 4mm distance to agreement metric, and of a 7% TLD dose comparison. We also determined sensitivity of the 3 dose planes of the TG-119 C-shape IMRT phantom using gamma criteria of 3% 3mm. Results: The largest clinical impact came from large changes in the DLG with a change of 1mm resulting in up to a 5% change in the primary PTV D99. This resulted in a discrepancy in the RPC TLDs in the PTVs and OARs of 7.1% and 13.6% respectively, which would have resulted in detection. While use of incorrect flattening filter caused only subtle errors (<1%) in clinical plans, the effect was most pronounced for the RPC TLDs in the OARs (>6%). Conclusion: The AAA commissioning process within the Eclipse TPS is surprisingly robust to user error. When errors do occur, the RPC and TG-119 commissioning credentialing criteria are effective at detecting them; however OAR TLDs are the most sensitive despite the RPC currently excluding them from analysis.

60 APPLIED LIFE SCIENCES↗

Aquatic Acoustic Metrics Interface

Fishes and marine mammals may suffer a range of potential effects from exposure to intense underwater sound generated by anthropogenic activities such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording (USR) devices have been built to acquire samples of the underwater sound generated by anthropogenic activities. Software becomes indispensable for processing and analyzing the audio files recorded by these USRs. The new Aquatic Acoustic Metrics Interface Utility Software (AAMI) is specifically designed for analysis of underwater sound recordings to provide data in metrics that facilitate evaluation of the potential impacts of the sound on aquatic animals. In addition to the basic functions, such as loading and editing audio files recorded by USRs and batch processing of sound files, the software utilizes recording system calibration data to compute important parameters in physical units. The software also facilitates comparison of the noise sound sample metrics with biological measures such as audiograms of the sensitivity of aquatic animals to the sound, integrating various components into a single analytical frame.

Source record↗

Probabilistic structural analysis computer code (NESSUS)

Probabilistic structural analysis has been developed to analyze the effects of fluctuating loads, variable material properties, and uncertain analytical models especially for high performance structures such as SSME turbopump blades. The computer code NESSUS (Numerical Evaluation of Stochastic Structure Under Stress) was developed to serve as a primary computation tool for the characterization of the probabilistic structural response due to the stochastic environments by statistical description. The code consists of three major modules NESSUS/PRE, NESSUS/FEM, and NESSUS/FPI. NESSUS/PRE is a preprocessor which decomposes the spatially correlated random variables into a set of uncorrelated random variables using a modal analysis method. NESSUS/FEM is a finite element module which provides structural sensitivities to all the random variables considered. NESSUS/FPI is Fast Probability Integration method by which a cumulative distribution function or a probability density function is calculated.

Shiao, Michael C.↗

An Enabling Platform for Achieving Multiscale Multiphysics Analysis of Multiphase Materials

This paper will address current NASA GRC research efforts utilizing the NASA Multiscale Analysis Tool (NASMAT) which address technical gaps in three of the Vision 2040 key discipline areas. NASMAT is a versatile platform for performing computationally efficient multiscale analyses of heterogeneous materials and is available free through the NASA software catalog. It offers the user flexibility to define an arbitrary number of length scales (levels) where a variety of micromechanics theories can be implemented at each level. Micromechanics theories can be selected to balance accuracy and computational efficiency and range from analytical (Mori-Tanaka) to several semi-analytical (method of cells) formulations. The resulting anisotropic, evolving nonlinear, thermomechanical constitutive model can also be coupled with external software and used to perform multiscale analyses of more complex structures. A recent application to model a complex, three-dimensional woven composite, with a particular emphasis placed on multiscale measurements utilized to enhance the quality of the multiscale analysis will be discussed. Since typical NASMAT analyses can be completed on the order of seconds to minutes, a second example will demonstrate the ability to generate large quantities of data useful for sensitivity analysis, uncertainty quantification, or machine learning applications. Current progress on implementing NASMAT within a multiscale digital thread/digital twin framework will also be addressed. These examples will demonstrate that NASMAT is an enabling platform for achieving the goals in Vision 2040.

Multiscale↗

Water-Soluble 2-Hydroxyisophthalamides for Sensitization of Lanthanide Luminescence

A series of octadentate ligands featuring the 2-hydroxyisophthalamide (IAM) antenna chromophore (to sensitize Tb(III) and Eu(III) luminescence) has been prepared and characterized. The length of the alkyl amine scaffold that links the four IAM moieties has been varied in order to investigate the effect of the ligand backbone on the stability and photophysical properties of the Ln(III) complexes. The amine backbones utilized in this study are N,N,N{prime},N{prime}-tetrakis-(2-aminoethyl)-ethane-1,2-diamine [H(2,2)-], N,N,N{prime},N{prime}-tetrakis-(2-aminoethyl)-propane-1,3-diamine [H(3,2)-] and N,N,N{prime},N{prime}-tetrakis-(2-aminoethyl)-butane-1,4-diamine [H(4,2)-]. These ligands also incorporate methoxyethylene [MOE] groups on each of the IAM chromophores to increase their water solubility. The aqueous ligand protonation constants and Tb(III) and Eu(III) formation constants were determined from solution thermodynamic studies. The resulting values indicate that at physiological pH, the Eu(III) and Tb(III) complexes of H(2,2)-IAM-MOE and H(4,2)-IAM-MOE are sufficiently stable to prevent dissociation at nanomolar concentrations. The photophysical measurements for the Tb(III) complexes gave overall quantum yield values of 0.56, 0.39, and 0.52 respectively for the complexes with H(2,2)-IAM-MOE, H(3,2)-IAM-MOE and H(4,2)-IAM-MOE, while the corresponding Eu(III) complexes displayed significantly weaker luminescence, with quantum yield values of 0.0014, 0.0015, and 0.0058, respectively. Analysis of the steady state Eu(III) emission spectra provides insight into the solution symmetries of the complexes. The combined solubility, stability and photophysical performance of the Tb(III) complexes in particular make them well suited to serve as the luminescent reporter group in high sensitivity time-resolved fluoroimmunoassays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contamination of grazing incidence EUV mirrors - An assessment

Contamination assessment for space optical systems requires an understanding of the sensitivity of component performance, e.g. mirror reflectance, to materials deposited on the mirror surface. In a previous study, the sensitivity of typical normal incidence mirror coatings to surface deposits of generic hydrocarbons was reported. Recent activity in the development of grazing incidence telescopes for extreme ultraviolet space astronomy has stimulated the need for a similar assessment in the spectral region extending from approximately 100 A to 1000 A. The model used for analysis treats the contamination layer as a continuous thin film deposited on the mirror surface. The mirror surfaces selected for this study are opaque vacuum deposited gold and the uncoated and polished Zerodur. Scatter caused by film irregularities or particulates are not included in this assessment. Parametric evaluations at 100, 500, and 1000 A determine the sensitivity of mirror reflectance to a range of optical constants selected for the generic contaminants. This sensitivity analysis combined with the limited amount of optical data in the EUV for hydrocarbons, is used to select representative optical constants for the three wavelength regions. Reflectance versus contamination layer thickness curves are then calculated and used to determine critical thickness limits based on allowable reflectance change. Initial observations indicate that thickness limits will be highly dependent on the real part of the complex index of refraction of the contaminant film being less than 1.0. Preliminary laboratory measurements of samples contaminated with some commonly encountered hydrocarbons confirm trends indicated in the analytical studies.

Osantowski, John F.↗

Improved Chromatographic Techniques for Sulfur Pollutants

This paper describes several improvements in instrumental techniques for the analysis of low ppb concentrations of sulfur gases using gas chromatography (G.C.). This work has focused on the analytical problem of ambient air monitoring of the two main sulfur gas pollutants, hydrogen sulfide and sulfur dioxide. The most significant technical improvement that will be reported here is the newly developed silica gel column for ppb concentrations of the light sulfur gases (COS, H2S, CS2, SO2, CH3SH). A simplified inlet system will be described which improves reliability of the GC system. The flame photometric detector is used as the means of selectively and sensitively detecting the low concentrations of sulfur gases. Improvements will be described which have yielded better performance than previously reported for this application of the detector. Also included in this paper will be a report of field monitoring using this improved GC system. Reliability and repeatability of performance at the low ppb concentrations of sulfur gases will be demonstrated.

Hartmann, C. H.↗

Hydrogen Isotopic Composition of Water in the Martian Atmosphere and Released from Rocknest Fines

The Mars Science Laboratory Curiosity rover sampled the aeolian bedform called Rocknest as its first solid samples to be analyzed by the analytical instruments CheMin and SAM. The instruments ingested aliquots from a sieved sample of less than 150 micrometer grains. As discussed in other reports at this conference [e.g., 1], CheMin discovered many crystalline phases, almost all of which are igneous minerals, plus some 10s of percent of x-ray amorphous material. The SAM instrument is focused on understanding volatiles and possible organics in the fines, performing evolved gas analysis (EGA) with the SAM quadrapole mass spectrometer (QMS), isotope measurements using both the QMS and the tunable laser spectrometer (TLS), which is sensitive to CO2, water and methane, and organics with the gas chromatograph mass spectrometer (GCMS). As discussed in the abstract by Franz et al. [2] and others, EGA of Rocknest fines revealed the presence of significant amounts of H2O as well as O-, C- and S-bearing materials. SAM has also tasted the martian atmosphere several times, analyzing the volatiles in both the TLS and QMS [e.g., 3,4]. This abstract will focus on presentation of initial hydrogen isotopic data from the TLS for Rocknest soils and the atmosphere, and their interpretation. Data for CO2 isotopes and O isotopes in water are still being reduced, but should be available by at the conference.

Leshin, L. A.↗

Compact Midwave Imaging System: Results from an Airborne Demonstration

The Compact Midwave Imaging System (CMIS) is a wide field of view, multi-angle, multi-spectral push frame imager that relies on the forward motion of the satellite to create a two-dimensional (2D) image swath. An airborne demonstration of CMIS was successfully completed in January-February 2021 on the NASA Langley Research Center Gulfstream III. The primary objective of the four-flight campaign was to demonstrate the capability of this unique instrument to perform stereo observations of clouds and other particulates (e.g. smoke) in the atmosphere. It is shown that the midwave infrared (MWIR) spectral bands of CMIS provide a unique 24/7 capability with high resolution for accurate stereo sensing.The instrument relies on new focal plane array (FPA) technology, which provides excellent sensitivity at much warmer detector temperatures than traditional technologies. This capability enabled a compact, low-cost design that can provide atmospheric motion vectors and cloud heights to support requirements for atmospheric winds in the 2017-2027 Earth Science Decadal Survey. Applications include day/night observations of the planetary boundary layer, severe weather, and wildfires. A comparison with current space-based earth science instruments demonstrates that the SWIR/MWIR multi-spectral capability of CMIS is competitive with larger, more expensive instrumentation. Imagery obtained over a controlled burn and operating nuclear power plant demonstrated the sensitivity of the instrument to temperature variations. The system relies on a mature stereoscopic imaging technique applied to the same scene from two independent platforms to unambiguously retrieve atmospheric motion vectors (AMVs) with accurate height assignment.This capability has been successfully applied to geostationary and low-earth orbit satellites to achieve excellent accuracy. When applied to a ground-point validation case, the accuracy for the CMIS aircraft observations was 20 m and 0.3 m/s for cloud heights and motion vectors, respectively. This result was confirmed by a detailed error analysis with analytical and covariance models. The results for CMIS cases with under flights of Aeolus, CALIPSO and Aqua provided a good validation of expected accuracies. The paper also showed the feasibility of accommodating CMIS on CubeSats to enable multiple instruments to be flown in a leader-follower mode.

stereo winds↗

A workflow for automatic generation and efficient refinement of individual pressure-dependent networks

Manual chemical kinetic model construction often requires modelists to at least implicitly guess all possible decay pathways and their relative fluxes for all important species. We present a workflow and associated tool for automatic generation and re finement of pressure-dependent networks that should enable modelists to efficiently and comprehensively identify decay pathways and estimate respective parameters for chemical species. This tool combines the capabilities of the Reaction Mechanism Generator (RMG) software to generate possible reaction paths, determine thermochemistry, approximate rate coefficients and estimate frequencies with the capabilities of the Arkane software to use quantum chemical parameters to compute thermochemistry and pressure dependent rates. A flux-based algorithm is used to decide which isomers to add to the network. Isomers added to the network are reacted to form other channels. When enough of the flux is accounted for by the isomers and bimolecular product channels, the generation process terminates to yield a comprehensive network. Network sensitivity analysis is applied to the network to identify the most important wells and barriers that can be refined using quantum chemistry calculations. Iterative refinement can then be used to achieve accuracy. The comprehensive network can be easily reduced using energy and flux-based algorithms to the most important channels and isomers in the network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

When physics-informed data analytics outperforms black-box machine learning: A case study in thickness control for additive manufacturing

Aerosol jet printing (AJP) has emerged as a promising noncontact additive manufacturing method for high-resolution printing for a wide range of material systems. A key challenge limiting the broader adoption of AJP in the material science community is the lack of methods to precisely control thickness. Herein, we develop a model-based design of experiment (MBDoE) framework that integrates physics-informed models, nonlinear regression, and information criteria to postulate, select and calibrate the best model to describe and optimize the AJP manufacturing process. Starting with already available data from system commissioning (e.g., prior single variable sensitivity analysis), four candidate physics-informed models are postulated and trained. MBDoE identifies a single additional optimal experiment to validate these predictive models with quantified uncertainties, which are then used to determine the best experimental conditions to control printed film thickness. As a comparative benchmark, the analysis is repeated using the same dataset with nonparametric Gaussian process regression (GPR) model that does not incorporate physical information. Using MBDoE principles, we find that only five experiments are necessary to calibrate the nonlinear physics-informed parametric model, and with said limited data, this model outperforms the black-box machine learning GPR model. This key result underscores an emerging trend in the data science community: incorporating physical information into predictive models often drastically reduces the data requirements. Leveraging MBDoE further increased the data efficiency. By design, the proposed data science framework is general in nature and can be easily extended to other experimental and additive manufacturing systems beyond AJP.

Aerosol jet printing↗

In situ Raman spectroscopy for growth monitoring of vertically aligned multiwall carbon nanotubes in plasma reactor

Portable and highly sensitive Raman setup was associated with a plasma-enhanced chemical vapor deposition reactor enabling in situ growth monitoring of multi-wall carbon nanotubes despite the combination of huge working distance, high growth speed and process temperature and reactive plasma condition. Near Edge X-ray absorption fine structure spectroscopy was used for ex situ sample analysis as a complementary method to in situ Raman spectroscopy. The results confirmed the fact that the “alternating” method developed here can accurately be used for in situ Raman monitoring under reactive plasma condition. The original analytic tool can be of great importance to monitor the characteristics of these nanostructured materials and readily define the ultimate conditions for targeted results.

36 MATERIALS SCIENCE↗

Linear complexity

We present factorization and solution phases for a new linear complexity direct solver designed for concurrent batch operations on fine-grained parallel architectures, for matrices amenable to hierarchical representation. We focus on the strong-admissibility-based $\mathscr{H}^{2}$ format, where strong recursive skeletonization factorization compresses remote interactions. We build upon previous implementations of $\mathscr{H}^{2}$ matrix construction for efficient factorization and solution algorithm design, which are illustrated graphically in stepwise detail. The algorithms are ‘blackbox’ in the sense that the only inputs are the matrix and right-hand side, without analytical or geometrical information about the origin of the system. We demonstrate linear complexity scaling in both time and memory on four representative families of dense matrices up to one million in size. Parallel scaling up to 16 threads is enabled by a multi-level matrix graph coloring and avoidance of dynamic memory allocations thanks to prefix-sum memory management. An experimental backward error analysis is included. We break down the timings of different phases, identify phases that are memory-bandwidth limited, and discuss alternatives for phases that may be sensitive to the trend to employ lower precisions for performance.

Boukaram, Wajih↗

Protocol for Future Amino Acid Analyses of Samples Returned by the Stardust Mission

We have demonstrated that LC-ToF-MS coupled with UV fluorescence detection is a powerful tool for the detection of amino acids in meteorite extracts. Using this new analytical technique we were able to identify the extraterrestrial amino acid AIB extracted from fifteen 20 micron sized Murchison meteorite grains. We found that the amino acid contamination levels in Stardust aerogels was much lower than the levels observed in the Murchison meteorite. In addition, the alpha-dialkyl amino acids AIB and isovaline which are the most abundant amino acids in Murchison were not detected in the aerogel above blank levels. We are currently integrating LIF detection capability to our existing nanoflow LC-ToF-MS for enhanced sensitivity required for the analysis of amino acids in Stardust samples.

Glavin, D. P.↗

Analytical Methods for Measuring Mercury in Water, Sediment and Biota

Mercury (Hg) exists in a large number of physical and chemical forms with a wide range of properties. Conversion between these different forms provides the basis for mercury's complex distribution pattern in local and global cycles and for its biological enrichment and effects. Since the 1960’s, the growing awareness of environmental mercury pollution has stimulated the development of more accurate, precise and efficient methods of determining mercury and its compounds in a wide variety of matrices. During recent years new analytical techniques have become available that have contributed significantly to the understanding of mercury chemistry in natural systems. In particular, these include ultra sensitive and specific analytical equipment and contamination-free methodologies. These improvements allow for the determination of total mercury as well as major species of mercury to be made in water, sediments and soils, and biota. Analytical methods are selected depending on the nature of the sample, the concentration levels of mercury, and what species or fraction is to be quantified. The terms “speciation” and “fractionation” in analytical chemistry were addressed by the International Union for Pure and Applied Chemistry (IUPAC) which published guidelines (Templeton et al., 2000) or recommendations for the definition of speciation analysis. "Speciation analysis is the analytical activity of identifying and/or measuring the quantities of one or more individual chemical species in a sample. The chemical species are specific forms of an element defined as to isotopic composition, electronic or oxidation state, and/or complex or molecular structure. The speciation of an element is the distribution of an element amongst defined chemical species in a system. In case that it is not possible to determine the concentration of the different individual chemical species that sum up the total concentration of an element in a given matrix, meaning it is impossible to determine the speciation, it is a useful practice to do fractionation instead. Fractionation is the process of classification of an analyte or a group of analytes from a certain sample according to physical (e.g. size, solubility) or chemical (e.g. bonding, reactivity) properties."

mercury↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

Flow through the tile gaps in the Space Shuttle Thermal Protection System

The problem of predicting aerodynamic loads on the insulating tiles of the Space Shuttle Thermal Protection System (TPS) is discussed and seen to require a method for predicting pressure and mass flux in the gaps between tiles. A mathematical model of the tile-gap flow is developed based upon a slow viscous (Stokes) flow analysis and is verified against available experimental data. This model derives the tile-gap pressure field from a solution of the two-dimensional Laplace equation; the mass flux vector is then calculated from the pressure gradient. The means for incorporating this model into a lumped-parameter network analogy for porous-media flow is also given. The flow model shows tile-gap mass flux to be very sensitive to the gap width indicating a need for coupling the TPS flow and tile displacement calculations. Finally recommendations are made concerning additional analytical and experimental work to improve TPS flow predictions.

Dwoyer, D. L.↗