Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “air conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Coordination Chemistry and Photoluminescence of Sm(II) Dibenzo-24-crown-8 Complexes

Three Sm(II) dibenzo-24-crown-8 (db24c8) complexes were synthesized in anhydrous, air-free conditions via the reaction of SmI 2 with db24c8 and tetrabutylammonium tetraphenylborate ([TBA][BPh 4 ]; where needed) in acetonitrile (CH 3 CN), dimethoxyethane (DME), and tetrahydrofuran (THF) to yield [Sm(db24c8)(CH 3 CN) 2 ][BPh 4 ][I]·CH 3 CN, [Sm(db24c8)(DME)]I 2 , and [Sm(db24c8)(THF) 2 ]I 2 , respectively. In each case, a 10-coordinate, staggered dodecahedral (2:6:2) environment is formed around the Sm 2+ center that is completed by either two solvent molecules (CH 3 CN or THF) or one bidentate solvent molecule (DME). Inner-sphere solvent molecules can be excluded by reacting SmI 2 with db24c8 in 1:3 THF:toluene to yield Sm(db24c8)I 2 . Here, this molecule features a distorted, eight-coordinate, hexagonal pyramidal Sm 2+ metal center, where the coordinated db24c8 molecule shows a torsion angle unexpectedly close to the 180° antiperiplanar arrangement and two uncoordinated db24c8 oxygen atoms. Solution UV–vis–NIR measurements demonstrate that Sm 2+ is a good size match for the cavity of various db24c8 conformations and that Eu 2+ and Yb 2+ exhibit competition between acetonitrile solvation and the Eu 2+ and Yb 2+ /db24c8 complexes in solution. During excitation by 546 nm light, both [Sm(db24c8)(DME)]I 2 and [Sm(db24c8)(THF) 2 ]I 2 exhibit mixed 5d → 4f and 4f → 4f emission at 20 °C and exclusively 4f → 4f at −180 °C, whereas Sm(db24c8)I 2 only shows 5d → 4f emission regardless of temperature. Photoluminescence from [Sm(db24c8)(CH 3 CN) 2 ][BPh 4 ][I]·CH 3 CN is quenched.

Cations↗

How Does LCL Height Influence Deep Convective Updraft Width?

Previous studies have hypothesized that the width of deep convection should positively scale with lifting condensation level (LCL) height. To evaluate this hypothesis, we analyzed idealized large-eddy simulations with varying LCL heights and initial warm bubble widths in unsheared environments with comparable convective available potential energy. For a given initial warm bubble width, simulations with higher LCLs result in wider, deeper, and stronger cloudy updrafts compared to simulations with lower LCLs. Rising dry thermals in higher LCL simulations experience longer residence times within the sub-cloud layer, and consequently entrain more conditionally unstable air and grow wider before reaching the LCL. The resulting cloudy updrafts are wider, deeper, and have faster vertical velocities because of a reduction in entrainment-driven dilution of buoyancy, relative to lower LCL simulations. These results confirm the hypothesized positive relationship between LCL height and deep convective updraft width, and provide a physical explanation for this relationship.

58 GEOSCIENCES↗

Reassessment of caustic scrubbing for radioiodine capture during UNF processing

The effective removal of iodine-129 from gaseous emissions during used nuclear fuel processing is critical for minimizing environmental contamination and ensuring environmental regulatory compliance. Recent research has focused on optimizing process air, scrubber conditions, and integrating complementary techniques, such as solid sorbents as a polishing step, to improve iodine capture efficiency. The efficiency of a caustic scrubber is influenced by several factors, such as pH, temperature, gas–liquid contact time, and the presence of oxidants, yet the existing literature tends not to consider how these factors might interact or change in importance with process scaling. This perspective advocates for reconsidering how to mitigate many of these factors, especially in view of the transition from laboratory bench to pilot scale and beyond. This paper reviews the principles, operational parameters, and advancements in caustic aqueous scrubbing for radioiodine mitigation, aims to direct the next scientific pursuit of this technology, and inform environmental decision-making.

Ngelale, Randy [Oak Ridge National Laboratory (ORN↗

Supervised Learning-Based Spatial Position Estimation with Vertical Displacement for Hovering UAV Wireless Power Transfer

This study presents a supervised learning-based spatial position estimation approach for wireless power transfer (WPT) systems supporting hovering unmanned aerial vehicle (UAV) charging. Unlike stationary charging scenarios, hovering UAVs introduce continuous lateral misalignment and vertical displacement, leading to variations in magnetic coupling and reduced power transfer efficiency. To address this challenge, the proposed method estimates the relative spatial position of the receiver coil using only electrical measurements obtained at the secondary side. A supervised learning model is trained to map output voltage and current features to spatial coordinates, enabling position awareness without requiring external sensors, vision systems, or communication links. The sensing functionality is inherently integrated into the WPT system, allowing simultaneous power transfer and localization through the same magnetic interface. Experimental validation is conducted on a laboratory-scale prototype under varying lateral offsets and air-gap conditions. In addition, spline-based interpolation is employed to increase spatial data density for training. The results demonstrate that the proposed framework can capture spatial variations associated with both lateral and vertical displacement, providing reliable position estimation under hovering conditions. This work establishes a hardware-efficient, sensorless solution for UAV wireless charging and serves as a baseline for advanced data-driven position estimation methods in dynamic WPT systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

An Edge-Cloud Integrated Solution for Buildings Demand Response Using Reinforcement Learning

Buildings, as major energy consumers, can provide great untapped demand response (DR) resources for grid services. However, their participation remains low in real-life. One major impediment for popularizing DR in buildings is the lack of cost-effective automation systems that can be widely adopted. Existing optimization-based smart building control algorithms suffer from high costs on both building-specific modeling and on-demand computing resources. To tackle these issues, this paper proposes a cost-effective edge-cloud integrated solution using reinforcement learning (RL). Beside RL’s ability to solve sequential optimal decision-making problems, its adaptability to easy-to-obtain building models and the off-line learning feature are likely to reduce the controller’s implementation cost. Using a surrogate building model learned automatically from building operation data, an RL agent learns an optimal control policy on cloud infrastructure, and the policy is then distributed to edge devices for execution. Simulation results demonstrate the control efficacy and the learning efficiency in buildings of different sizes. A preliminary cost analysis on a 4-zone commercial building shows the annual cost for optimal policy training is only 2.25% of the DR incentive received. Results of this study show a possible approach with higher return on investment for buildings to participate in DR programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local Communication in Populations of Thermostatically Controlled Loads

Thermostatically controlled loads (TCLs) have shown great potential for demand response (DR) in electric grid operations. However, it has been commonly seen that DR events using TCLs may cause load synchronization and unwanted oscillatory effects, especially in homogeneous populations. In an attempt to mitigate the negative impacts of DR events, a decentralized method is proposed that modifies each thermostat behavior based on the activity of a small number of nearby TCLs. This feedback introduces the possibility of instability in the aggregate behavior. A stability analysis is performed on a linearized model of the aggregate system and the results of that analysis compared to simulation results. The proposed modification of thermostat behavior results in fourfold reduction in the post-DR peak while suppressing ensuing oscillations at the expense of a modest increase in compressor cycling. Further, the linearized model also provides insight into the aggregate behavior of the population.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

The Influence of Shear on Deep Convection Initiation. Part II: Simulations

Abstract This study evaluates a hypothesis for the role of vertical wind shear in deep convection initiation (DCI) that was introduced in Part I by examining behavior of a series of numerical simulations. The hypothesis states, “Initial moist updrafts that exceed a width and shear threshold will ‘root’ within a progressively deeper steering current with time, increase their low-level cloud-relative flow and inflow, widen, and subsequently reduce their susceptibility to entrainment-driven dilution, evolving toward a quasi-steady self-sustaining state.” A theoretical model that embodied key elements of the hypothesis was developed in Part I, and the behavior of this model was explored within a multidimensional environmental parameter space. Remarkably similar behavior is evident in the simulations studied here to that of the theoretical model, both in terms of the temporal evolution of DCI and in the sensitivity of DCI to environmental parameters. Notably, both the simulations and theoretical model experience a bifurcation in outcomes, whereby nascent clouds that are narrower than a given initial radius R 0 threshold quickly decay and those above the R 0 threshold undergo DCI. An important assumption in the theoretical model, which states that the cloud-relative flow of the background environment V CR determines cloud radius R , is scrutinized in the simulations. It is shown that storm-induced inflow is small relative to V CR beyond a few kilometers from the updraft edge, and V CR therefore plays a predominant role in transporting conditionally unstable air to the updraft. Thus, the critical role of V CR in determining R is validated.

58 GEOSCIENCES↗

An Investigation of Innovative Energy Technologies Entering the Market between 2009-2015, Enabled by EERE-Funded R&D

This report documents technologies that have been commercialized by the private sector and other partners—such as technology developers in startups, companies, and universities—in part because of R&D funding from EERE. It also documents emerging technologies that have the potential to reach the market within the next three years with the support of EERE R&D investments. Commercial and emerging technology tracking in this manner assists EERE technology managers, analysts, communications staff, and senior management in describing and explaining the benefits of EERE-funded research. Policy- and decision-makers would then have the latest information to guide future program development and direction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An LSTM Deep Learning Network for ¿Background Radiation Prediction

Determination of appropriate background radiation is important in any measurement application. Environmental radiation monitors and monitors used to assess dose to individuals outside of controlled areas are particularly susceptible to changes in readings due to fluctuations in the environmental conditions. These fluctuations (e.g. radon progeny concentrations) lead to changes in the detector response in the actual radiation environment, and they need to be taken into account when extracting the net operational doses. Work has been ongoing to apply advances in Deep Learning and Artificial Intelligence to account for changes in detector responses based on environmental parameters; in particular, a Long-Short Term Memory (LSTM) Deep Learning architecture has been utilized to incorporate time-series data into a prediction model. In this work, we present the current status of the project to predict radiation measurements based on meteorological conditions and air packet trajectories extracted using the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT4) model.

Degtiarenko, Pavel↗

The Levelized Cost of Exergy Framework

Exergy is the amount of energy within a substance or within a transfer of energy that can be used to produce work or some other useful output when interacting with some reference environment. Two different energy systems that produce the same output with the same exergetic efficiency must necessarily have the same amount of exergy input, even if the amount of energy input to the two systems is vastly different. For example, a low-grade heat-driven desalination would require far more energy input than a reverse osmosis (RO) plant producing the same amount of water, but if their exergetic efficiencies were the same, they would require the same amount of exergy input. Thus, comparisons between different energy sources on the basis of energy is not always appropriate. Instead, a comparison on a per unit exergy basis provides more insight on the cost-effectiveness of different energy sources and systems. In this presentation, we describe a framework for analyzing the levelized cost of exergy (LCOEx) for both inputs and outputs of various energy systems. Our framework illustrates how the cost per unit exergy of a system's energy source, as well as the exergetic efficiency of the system, greatly affect the cost of the system output. We use the levelized cost of electricity as a benchmark value for LCOEx, due to electricity's ubiquity as an energy source, and because it is relatively inexpensive on a per unit exergy basis. The LCOEx of various heat sources are then compared to the LCOEx of electricity. Medium- and high-grade industrial heat (> 150 degrees C) produced by natural gas tends to have an LCOEx on par with electricity. This is due to the low cost of natural gas, as well as the high exergy content of heat at higher temperatures. Meanwhile, low-grade heat tends to be an expensive exergy source, owing to the low exergy content of the low-grade heat. We first apply our framework to desalination, where RO has come to dominate, due to the low LCOEx of the energy source (electricity) and relatively high exergetic efficiency of RO compared to thermal desalination systems. We then use this framework to highlight an opportunity for dehumidification systems to experience a similar cost improvement as desalination has. If an electrically-driven, high exergetic efficiency dehumidification system were developed (such as the membrane-based dehumidification systems proposed in literature), it would use a low cost exergy source with a high exergetic efficiency and could potentially lower the cost of dehumidification in the way that RO has done for desalination. Finally, we apply our framework to various fuels (natural gas, hydrogen, gasoline, etc.) and energy systems across different sectors (desalination, dehumidification, vehicles, etc.) to understand the variation in the cost of exergy input and exergetic efficiency of different systems and technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Phenomena Identification and Ranking Tables for High Temperature Gas-Cooled Microreactors

Micro-scaled high-temperature gas-cooled reactors (micro-HTGRs) offer a promising option for reliable power in remote or off-grid locations. While the safety characteristics of modular HTGRs have been widely studied, a micro-HTGR configuration alters several key thermal-fluid phenomena that govern both normal operation and passive decay-heat removal. In many proposed concepts, the reactor vessel is oriented horizontally and integrated into an ISO shipping container to enhance transportability and modular deployment. This report documents a Phenomena Identification and Ranking Table (PIRT) exercise focused on the thermal hydraulic safety phenomena relevant to all micro-HTGRs. The objective is to systematically identify, describe, and rank the importance, uncertainty, and modeling complexity of the key phenomena that control core and vessel temperatures during normal operation, pressurized conduction cooldown (PCC), and depressurized conduction cooldown (with air ingress) conditions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗