Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Wide dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Optimal calibration of gates in trapped-ion quantum computers

Abstract To harness the power of quantum computing, it is essential that a quantum computer provide maximal possible fidelity for a quantum circuit. To this end, much work has been done in the context of qubit routing or embedding, i.e., mapping circuit qubits to physical qubits based on gate performance metrics to optimize the fidelity of execution. Here, we take an alternative approach that leverages a unique capability of a trapped-ion quantum computer, i.e., the all-to-all qubit connectivity. We develop a method to determine a fixed number (budget) of quantum gates that, when calibrated, will maximize the fidelity of a batch of input quantum programs. This dynamic allocation of calibration resources on randomly accessible gates, determined using our heuristics, increases, for a wide range of calibration budget, the average fidelity from 70% or lower to 90% or higher for a typical batch of jobs on an 11-qubit device, in which the fidelity of calibrated and uncalibrated gates are taken to be 99% and 90%, respectively. Our heuristics are scalable, more than 2.5 orders of magnitude faster than a randomized method for synthetic benchmark circuits generated based on real-world use cases.

Maksymov, Andrii (ORCID:0000000282442851)↗

Mass Spectrometry for Translational Proteomics: Progress and Clinical Implications

Mass spectrometry (MS)-based proteomics measurements have become increasingly utilized in a wide range of biological and biomedical applications, and have significantly enhanced the understanding of the complex and dynamic nature of the proteome and its connections to biology and diseases. While some MS techniques such as those for targeted analysis are increasingly applied with great success, others such as global quantitative analysis (for e.g. biomarker discovery) are more challenging and continue to be developed and refined to provide the desired throughput, sensitivity and/ or specificity. New MS capabilities and proteomics-based pipelines/strategies also keep enhancing for the advancement of clinical proteomics applications such as protein biomarker discovery and validation. Herein, we provide a brief review to summarize the current state of MS-based proteomics with respect to its advantages and present limitations, while highlighting its potential in future clinical applications.

59 BASIC BIOLOGICAL SCIENCES↗

Computational Modeling of Fluctuations in Energy and Metabolic Pathways of Methanogenic Archaea

The methanogenic archaea, anaerobic microbes that convert CO2 and H2 and/or other small organic fermentation products into methane, play an unusually large role in the global carbon cycle. As they perform the final step in the anaerobic breakdown of biomass, methanogens are a biogenic source of an estimated one billion tons methane each year. Depending on the location, produced methane can be considered as either a greenhouse gas (agricultural byproduct), sequestered carbon storage (methane hydrate deposits), or a potential energy source (organic wastewater treatment). These microbes therefore represent an important target for biotechnology applications. Computational models of methanogens with predictive power are useful aids in the adaptation of methanogenic systems, but need to connect processes of wide-ranging time and length scales. In this project, we developed several computational methodologies for modeling the dynamic behavior of entire cells that connects stochastic reaction-diffusion dynamics of individual biochemical pathways with genome-scale modeling of metabolic networks. While each of these techniques were in the realm of well-defined computational methods, here we integrated them to develop several entirely new approaches to systems biology. The first scientific aim of the project was to model how noise in a biochemical pathway propagates into cellular phenotypes. Genetic circuits have been optimized by evolution to regulate molecular processes despite stochastic noise, but the effect of such noise on a cellular biochemical networks is currently unknown. An integrated stochastic/systems model of Escherichia coli species was created to analyze how noise in protein expression gives—and therefore noise in metabolic fluxes—gives rise to multiple cellular phenotype in isogenic population. After the initial work developing and validating methods that allow characterization of the heterogeneity in the model organism E. coli, the project shifted toward investigations of the methanogen Methanosarcina acetivorans. By integrating an unprecedented transcriptomics dataset for growth of the methanogen on many substrates with an in silico model, heterogeneity in metabolic pathway usage and methane production were examined. This lent insight into the physiological requirements of the organism under different environmental conditions and uncovered the unique regulatory role that mRNA half-life has in shaping metabolic flux distributions in this organism.

59 BASIC BIOLOGICAL SCIENCES↗

Observations of large scale steady magnetic fields in the nightside Venus ionosphere and near wake

Based on an analysis of a large sample of Pioneer Venus Orbiter magnetometer data, characteristics of the magnetic fields near nightside periapsis are discussed. The observations generally indicate a weak average field of less than 10 gammas between 200 km and the periapsis altitude of 150 km, except when (1) the local solar wind dynamic pressure is high or (2) the spacecraft is in a 70 deg wide solar zenith angle range, which includes the midnight meridian and is centered west of it at 1 hr local time. The presence of radial field of alternating sign at low altitudes and in the nightside ionosphere suggests that the antiparallel magnetotail fields can terminate very close to the planet.

Luhmann, J. G.↗

Orbiting Space Interferometer (OSI): A first generation space interferometer

The technical requirements and performance of a first generation space interferometer is discussed. The performance of an interferometer, sensitivity, field of view, dynamic range, astrometric accuracy, etc, in space is set by what cannot be achieved for a ground-based instrument. For the Orbiting Space Interferometer (OSI), the nominal performance parameters are 20 mag sensitivity, field of view of approximately 500*500 pixels, a 1000:1 dynamic range in the image with one milliarcsec resolution, and an astrometric accuracy of 0.1 milliarcsec for wide angle astrometry and 10 microarcsec accuracy for narrow field astrometry (few degrees). OSI is a fully phased interferometer where all critical optical paths are controlled to 0.05 wavelengths. The instrument uses two guide interferometers locked on bright stars several degrees away to provide the spacecraft attitude information needed to keep the fringes from the faint science object stable on the detector.

Shao, Michael↗

Practical Applications of Cables and Ropes in the ISS Countermeasures System

As spaceflight durations have increased over the last four decades, the effects of weightlessness on the human body are far better understood, as are the countermeasures. A combination of aerobic and resistive exercise devices contribute to countering the losses in muscle strength, aerobic fitness, and bone strength of today's astronauts and cosmonauts that occur during their missions on the International Space Station. Creation of these systems has been a dynamically educational experience for designers and engineers. The ropes and cables in particular have experienced a wide range of challenges, providing a full set of lessons learned that have already enabled improvements in on-orbit reliability by initiating system design improvements. This paper examines the on-orbit experience of ropes and cables in several exercise devices and discusses the lessons learned from these hardware items, with the goal of informing future system design.

Moore, Cherice↗

Comparison of CFD and DSMC Using Calibrated Transport Parameters

Hypersonic re-entry flows span a wide range of length scales where regions of both rarefied and continuum flow exist. Traditional computational fluid dynamics (CFD) techniques do not provide an accurate solution for the rarefied regions of such ‘mixed’ flow fields. Although direct simulation Monte Carlo (DSMC) can be used to accurately capture both the continuum and rarefied features of ‘mixed’ flow fields, they are computationally expensive when employed to simulate the low Knudsen number continuum regimes. Thus, a hybrid framework for seamlessly combining the two methodologies, CFD and DSMC, continues to be a topic of significant research effort. Ensuring consistency in the reaction kinetics and transport models employed within CFD and DSMC is a crucial requirement for obtaining a reliable solution from a hybrid framework for combined continuum/rarefied high speed flows. This paper represents one of the first studies to utilize the calibrated transport parameters developed to ensure consistency between CFD and DSMC solvers. The new variable soft sphere (VSS) parameters are compared to both previous “standard” variable hard sphere (VHS) parameters and also to solutions from the CFD transport properties that the new parameters were developed to reproduce.

Liechty, D. S.↗

Temperature Dependent Pspice Model

This paper provides a behavioral model in Pspice for a silicon carbide (SiC) power MOSFET rated at 1200 V / 20 A for a wide temperature range. The Pspice model is built using device parameters extracted through experiment. The static and dynamic behavior of the SiC power MOSFET is simulated and compared to the measured data to show the accuracy of the Pspice model. The switching losses are obtained from experiment under multiple operation conditions. The temperature dependent behavior has been simulated and analyzed. Then the parasitics in the circuit have been studied and the effects on the switching behavior are simulated and discussed.

Tolbert, Leon M↗

National Wind Technology Center Dynamic 5-Megawatt Dynamometer

The National Wind Technology Center (NWTC) offers wind industry engineers a unique opportunity to conduct a wide range of tests. Its custom-designed dynamometers can test wind turbine systems from 1 kilowatt (kW) to 5 megawatts (MW). The NWTC's new dynamometer facility simulates operating field conditions to assess the reliability and performance of wind turbine prototypes and commercial machines, thereby reducing deployment time, failures, and maintenance or replacement costs. Funded by the U.S. Department of Energy with American Recovery and Reinvestment Act (ARRA) funds, the 5-MW dynamometer will provide the ability to test wind turbine drivetrains and connect those drivetrains directly to the electricity grid or through a controllable grid interface (CGI). The CGI tests the low-voltage ride-through capability of a drivetrain as well as its response to faults and other abnormal grid conditions.

17 WIND ENERGY↗

NREL CGI and PHIL Platform for Validation of Multi-Technology Energy Systems at Scale

The presentation is an update on National Renewable Energy Laboratory Flatirons Campus' capabilities around multi-megawatt grid simulation and power hardware-in-the-loop. Recent improvements in operational and dynamic range of existing 7MVA Controllable Grid Interface (CGI) are described together with improvements in site-wide automation and data acquisition systems. In later part of presentation, a second 19.9MVA CGI that is currently under development is introduced. Its features are described further explaining future site's capabilities.

acquisition↗

Structure of ice confined in silica nanopores

Observed anomalous thermodynamic properties of confined water such as deviations in the melting point and freezing point motivate the determination of the structure of confined water as a function of pore size and temperature. Here, we investigate the dynamic evolution of the structure of confined ice in SBA-15 porous materials with pore diameters of 4 nm, 6 nm, and 8 nm at temperatures ranging from 183 K to 300 K using in operando Wide-Angle X-Ray Scattering (WAXS) measurements, X-Ray Partial Distribution Function (PDF) measurements, and classical Molecular Dynamics (MD) simulations. Formation of hexagonal ice structures is noted in all the three pore sizes. In silica nanopores with diameters of 4 nm, cubic ice formation is noted in addition to hexagonal ice. Longer lasting hydrogen bonds and longer residence times of the water molecules in the first coordination shell contribute to observed crystalline organization of ice in confinement. Self-diffusion coefficients of confined liquid water, predicted from classical MD simulations, are four orders of magnitude higher compared to ice formed in confinement. These experimental and simulation results provide comprehensive insights underlying the organization of confined water and ice in silica nanopores and the underlying physico-chemical interactions that contribute to the observed structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A fast integrated mobility spectrometer for rapid measurement of sub-micrometer aerosol size distribution, Part I: Design and model evaluation

This study discusses, a fast integrated mobility spectrometer (FIMS) was previously developed to characterize submicron aerosol size distributions at a frequency of 1 Hz and with high size resolution and counting statistics. However, the dynamic size range of the FIMS was limited to one decade in particle electrical mobility. It was proposed that the FIMS dynamic size range can be greatly increased by using a spatially varying electric field. This electric field creates regions with drastically different field strengths in the separator, such that particles of a wide diameter range can be simultaneously classified and subsequently measured. A FIMS incorporating this spatially varying electric field is developed. This paper describes the theoretical frame work and numerical simulations of the FIMS with extended dynamic size range, including the spatially varying electric field, particle trajectories, activation of separated particles in the condenser, and the transfer function, transmission efficiency, and mobility resolution. The influences of the particle Brownian motion on FIMS transfer function and mobility resolution are examined. The simulation results indicate that the FIMS incorporating the spatially varying electric field is capable of measuring aerosol size distribution from 8 to 600 nm with high time resolution. As a result, the experimental characterization of the FIMS is presented in an accompanying paper.

54 ENVIRONMENTAL SCIENCES↗

Correlation of dynamic dielectric measurements with viscosity in polymeric resin systems

Dynamic dielectric analysis has been used to study curing polymer systems and thermoplastics. Measurements have been made over a frequency range of six decades. This wide range of frequencies increases the amount of information which can be obtained. The data are analyzed in terms of the frequency dependence of the specific conductivity sigma and the relaxation time tau, parameters which are characteristic of the cure state of the material and independent of size of the sample. Dynamic dielectric measurements have been correlated with viscosity for the polysulfone thermoplastic UDEL-P1700 and with viscosity and ultrasonic measurements on the DGEBA-type epoxy Epon 828 cured with Agent U. The experimental results suggest that when ionic processes dominate the dielectric response, the intensive property sigma is a good monitor of the resin's viscosity. The results show that the dielectric relaxation time tau can be used to monitor the state of the system and the extent and rate of the reaction.

Kranbuehl, D.↗

Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments ({sigma}/{mu} < 5% for all metrics investigated). The dynamic flow phantom was capable of producing input and output TACs using either step function based or typical clinical arterial input function (AIF) inputs. The measured TACs were in excellent agreement with predictions across all comparison metrics with goodness of fit (R{sup 2}) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The predicted output functions were similarly accurate producing R{sup 2} values between 0.92 and 0.99 and maximum enhancement to within 9.0%. The effect of ROI size on the arterial input function (AIF) was investigated in order to determine an operating range of ROI sizes which were minimally affected by noise for small dimensions and partial volume effects for large dimensions. It was possible to establish the measurement sensitivity of both the Toshiba (ROI radius range from 1.5 to 3.2 mm ''low dose'', 1.4 to 3.0 mm ''high dose'') and GE scanner (1.5 to 2.6 mm ''low dose'', 1.1 to 3.4 mm ''high dose''). This application of the phantom also provides the ability to evaluate the effect of the AIF error on kinetic model parameter predictions. Conclusions: The dynamic flow imaging phantom is capable of producing accurate and reproducible results which can be predicted and quantified. This results in a unique tool for perfusion DCE-CT validation under realistic flow conditions which can be applied not only to compare different CT scanners and imaging protocols but also to provide a ground truth across multimodality dynamic imaging given its MRI and PET compatibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of multiobjective optimization methods for the $\mathrm{LCLS-II}$ photoinjector

Particle accelerators are among some of the largest science experiments in the world and can consist of thousands of components with a wide variety of input ranges. These systems can easily become unwieldy optimization problems during design and operations studies. Starting in the early 2000s, searching for better beam dynamics configurations became synonymous with heuristic optimization methods in the accelerator physics community. Genetic algorithms and particle swarm optimization are currently the most widely used. These algorithms can take thousands of simulation evaluations to find optimal solutions for one machine prototype. For large facilities such as the Linac Coherent Light Source (LCLS) and others, this equates to a limited exploration of many possible design configurations. In this paper, the LCLS-II photoinjector is optimized with three optimization algorithms. All optimizations were started from both a uniform random and Latin hypercube sample. In all cases, the optimizations started from Latin hypercube samples outperformed optimizations started from uniform samples. All three algorithms were able to optimize the photoinjector, with the model-based methods approximating the Pareto front in fewer simulation evaluations. This work, in combination with previous optimization observations, indicates objective penalties have a strong impact on the efficiency of such methods. In general, we recommend heuristic methods for initial optimizations and model-based methods when information about the objective space is available.

43 PARTICLE ACCELERATORS↗

Electron trapping in evolving coronal structures during a large gradual hard X-ray/radio burst

Gradual hard X-ray/radio bursts are characterized by their long duration, smooth time profile, time delays between peaks at different hard X-ray energies and microwaves, and radiation from extended sources in the low and middle corona. Their characteristic properties have been ascribed to the dynamic evolution of the accelerated electrons in coronal magnetic traps or to the separate acceleration of high-energy electrons in a 'second step' process. The information available so far was drawn from quality considerations of time profiles or even only from the common occurrence of emissions in different spectral ranges. This paper presents model computations of the temporal evolution of hard X-ray and microwave spectra, together with a qualitative discussion of radio lightcurves over a wide spectral range, and metric imaging observations. The basis hypothesis investigated is that the peculiar 'gradual' features can be related to the dynamical evolution of electrons injected over an extended time interval in a coronal trap, with electrons up to relativistic energies being injected simultaneously. The analyzed event (26 April. 1981) is particularly challenging to this hypothesis because of the long time delays between peaks at different X-ray energies and microwave frequencies. The observations are shown to be consistent with the hypothesis, provided that the electrons lose their energy by Coulomb collisions and possibly betatron deceleration. The access of the electrons to different coronal structures varies in the course of the event. The evolution and likely destabilization of part of the coronal plasma-magnetic field configuration is of crucial influence in determining the access to these structures and possibly the dynamical evolution of the trapped electrons through betatron deceleration in the late phase of the event.

Bruggmann, G.↗

Speed Variation Based Power Regulation Concept for Dynamic Wireless Charging

On-road wireless charging of electric vehicles (EVs) in-motion could potentially reduce range anxiety or battery size with wide-spread deployment. The planning and implementation of such systems are greatly complicated due to their susceptibility to load variation inherent to traffic flow. Here, this paper proposes a method for derisking the potential for traffic slowdowns by compensating for reduced vehicle speed and investigates how implementation may affect system performance. A load modeling case study is presented at 200kW for a mile of high-speed roadway employing speed-based power regulation with results indicating average power usage and maximum car hosting capability can be reduced by 20% and increased by 30% respectively. An 85kHz power electronics model is developed based on designs and prototypes for an 11kW, 190m airgap static system and a 200kW dynamic wireless track. The simulation is validated in the 11kW experimental prototype and modified for 200kW operation to compare with simulated performance. Sensitivity studies are performed in MATLAB/Simulink to evaluate how parameters influence system performance and confirm the capability to reduce output power and maintain efficiency at 11 and 200kW. The static 11kW experimental system operates at 93.6% efficiency and multiple options exist to reduce power while maintaining efficiency greater than 90%. The capability to dynamically modify power output from WPT coils, in an experimentally validated simulation, enables techniques to significantly mitigate load variability due to reductions in vehicle speed.

42 ENGINEERING↗

Hubble Space Telescope Medium Deep Survey. 2: Deconvolution of Wide Field Camera field galaxy images in the 13 hour + 43 deg field

We present isophotal profiles of six faint field galaxies from some of the first deep images taken for the Hubble Space Telescope (HST) Medium Deep Survey (MDS). These have redshifts in the range z = 0.126 to 0.402. The images were taken with the Wide Field Camera (WFC) in `parallel mode' and deconvolved with the Lucy method using as the point-spread function nearby stars in the image stack. The WFC deconvolutions have a dynamic range of 16 to 20 dB (4 to 5 mag) and an effective resolution approximately less than 0.2 sec (FWHM). The multiorbit HST images allow us to trace the morphology, light profiles, and color gradients of faint field galaxies down to V approximately equal to 22 to 23 mag at sub-kpc resolution, since the redshift range covered is z = 0.1 to 0.4. The goals of the MDS are to study the sub-kpc scale morphology, light profiles, and color gradients for a large samole of faint field galaxies down to V approximately equal to 23 mag, and to trace the fraction of early to late-type galaxies as function of cosmic time. In this paper we study the brighter MDS galaxies in the 13 hour + 43 deg MDS field in detail, and investigate to what extent model fits with pure exponential disks or a(exp 1/4) bulges are justified at V approximately less than 22 mag. Four of the six field galaxies have light profiles that indicate (small) inner bulges following r(exp 1/4) laws down to 0.2 sec resolution, plus a dominant surrounding exponential disk with little or no color gradients. Two occur in a group at z = 0.401, two are barred spiral galaxies at z = 0.179 and z = 0.302, and two are rather subluminous (and edge-on) disk galaxies at z = 0.126 and z = 0.179. Our deep MDS images can detect galaxies down to V, I approximately less than 25 to 26 mag, and demonstrate the impressive potential of HST--even with its pre-refurbished optics--to resolve morphological details in galaxies at cosmologically significant distances (v approximately less than 23 mag). Since the median redshift of these galaxies is approximately less than 0.4, the HST resolution allows us to study sub kpc size scales at the galaxy, which cannot be done with stable images over wide fields from the best ground-based sites.

Windhorst, R. A.↗