Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Investigation of VEGGIE Root Mat

VEGGIE is a plant growth facility that utilizes the phenomenon of capillary action as its primary watering system. A cloth made of Meta Aramid fiber, known as Nomex is used to wick water up from a reservoir to the bottom of the plants roots. This root mat system is intended to be low maintenance with no moving parts and requires minimal crew interface time. Unfortunately, the water wicking rates are inconsistent throughout the plant life cycle, thus causing plants to die. Over-wicking of water occurs toward the beginning of the cycle, while under-wicking occurs toward the middle. This inconsistency of wicking has become a major issue, drastically inhibiting plant growth. The primary objective is to determine the root cause of the inconsistent wicking through experimental testing. Suspect causes for the capillary water column to break include: a vacuum effect due to a negative pressure gradient in the water reservoir, contamination of material due to minerals in water and back wash from plant fertilizer, induced air bubbles while using syringe refill method, and material limitations of Nomex's ability to absorb and retain water. Experimental testing will be conducted to systematically determine the cause of under and over-wicking. Pressure gages will be used to determine pressure drop during the course of the plant life cycle and during the water refill process. A debubbler device will be connected to a root mat in order to equalize pressure inside the reservoir. Moisture and evaporation tests will simultaneously be implemented to observe moisture content and wicking rates over the course of a plant cycle. Water retention tests will be performed using strips of Nomex to determine materials wicking rates, porosity, and absorptivity. Through these experimental tests, we will have a better understanding of material properties of Nomex, as well as determine the root cause of water column breakage. With consistent test results, a forward plan can be achieved to resolve the issue and give valuable insight for the next generation of VEGGIE.

Subbiah, Arun M.↗

Solar system installation at Louisville, Kentucky

The installation of a solar space heating and domestic hot water system is described. The overall philosophy used was to install both a liquid and a hot air system retrofitted to existing office and combined warehouse building. The 1080 sq. ft. office space is heated first and excess heat is dumped into the warehouse. The two systems offer a unique opportunity to measure the performance and compare results of both air and liquid at one site.

Source record↗

Water vapor measurement system in global atmospheric sampling program, appendix

The water vapor measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available dew/frostpoint hygrometer with a thermoelectrically cooled mirror sensor. The modifications extended the range of the hygrometer to enable air sample measurements with frostpoint temperatures down to -80 C at altitudes of 6 to 13 km. Other modifications were made to permit automatic, unattended operation in an aircraft environment. This report described the hygrometer, its integration with the GASP system, its calibration, and operational aspects including measurement errors. The estimated uncertainty of the dew/frostpoint measurements was + or - 1.7 Celsius.

Englund, D. R.↗

Intermediate Temperature Water Heat Pipe Tests

Heat pipes are among the most promising technologies for space radiator systems. Water heat pipes are explored in the intermediate temperature range of 400 to above 500 K. The thermodynamic and thermo-physical properties of water are reviewed in this temperature range. Test data are reported for a copper-water heat pipe. The heat pipe was tested under different orientations. Water heat pipes show promise in this temperature range. Fabrication and testing issues are being addressed.

Devarakonda, Angirasa↗

Intermediate Temperature Water Heat Pipe Tests

Heat pipes are among the most promising technologies for space radiator systems. Water heat pipes are explored in the intermediate temperature range of 400 to above 500 K. The thermodynamic and thermo-physical properties of water are reviewed in this temperature range. Test Data are reported for a copper-water heat pipe. The heat pipe was tested under different orientations. Water heat pipes show promise in this temperature range.Fabrication and testing issues are being addressed.

Devarakonda, Angirasa↗

Shallow Water Imaging Sonar System for Environmental Surveying Final Report CRADA No. TC-1130-95

The scope of this research is to develop a shallow water sonar system designed to detect and map the location of objects such as hazardous wastes or discarded ordnance in coastal waters. The system will use high frequency wide-bandwidth imaging sonar, mounted on a moving platform towed behind a boat, to detect and identify objects on the sea bottom. Resolved images can be obtained even if the targets are buried in an overlayer of silt. Reference 1 ( also attached) summarized the statement of work and the scope of collaboration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water vapor radiometry research and development phase

This report describes the research and development phase for eight dual-channel water vapor radiometers constructed for the Crustal Dynamics Project at the Goddard Space Flight Center, Greenbelt, Maryland, and for the NASA Deep Space Network. These instruments were developed to demonstrate that the variable path delay imposed on microwave radio transmissions by atmospheric water vapor can be calibrated, particularly as this phenomenon affects very long baseline interferometry measurement systems. Water vapor radiometry technology can also be used in systems that involve moist air meteorology and propagation studies.

Resch, G. M.↗

Operational tests of a solar-energy system in Georgia

Seventy three page report describes one year performance of commercial solar-energy hot-water system. Silicone oil is heat-exchange fluid in tested system, designed to meet needs of family of four. Roll-bend heat exchanger is wrapped around hot-water storage tank. Oil circulates through exchanger and flat-plat solar collectors. Auxiliary energy, to maintain temperature in storage tank, is supplied by 4,500-watt resistance-heating element.

Source record↗

A novel green hydrogen production using water-energy nexus framework

The transformation of electrical energy to hydrogen via water electrolysis consumes considerable amount of fresh water and a productive use of nontraditional water sources enhances the reliability and resilience of energy and water systems. In this study, we have designed a solid oxide electrolysis cell (SOEC) system which is an evolving hydrogen production technology at high temperatures for water electrolysis. Here, the SOEC uses steam generated from flue gas as its feedstock and is fully integrated with numerous power production units, including coal and natural gas-fired power plants as its energy feedstock. While there is a hasten global shift away from fossil fuel, integrating its asset into this technology helps limit the risk and future losses of stranded assets and reduce the cost of investment in the new technologies. But high capital expenditures and doubt concerning the future cost and efficiency upgrade are obstacles to investing in water electrolysis. Such a detailed Levelized cost of hydrogen and techno-economic analysis is conducted to show the viability and environmental impacts of this novel technology. The results show SOEC efficiency of 97.4 % and 56.3 % as thermal-to-hydrogen efficiency of the system with a daily hydrogen production of 242,400 kg at $2.9–3.5/kg H 2 . The estimates show a positive gain prospect in this technology and techno-economic challenges.

08 HYDROGEN↗

Evaluation of the Biocidal Efficacy of Different Forms of Silver Against Cupriavidus (formerly Wautersia) Species Bacteria

Contingency Water Containers (CWCs) are used to store potable and technical water that is transferred to the International Space Station (ISS) from the Shuttle orbiter vehicles. When CWCs are filled, water from the orbiter galley is passed through an ion exchange/activated carbon cartridge that removes the residual iodine biocide used on Shuttle before silver biocide is added. Removal of iodine and addition of silver is necessary to inhibit microbial growth inside CWCs and maintain compatibility with the water systems in the Russian segment of ISS. As part of nominal water transfer activities, crewmembers collect samples from several CWCs for postflight analysis. Results from the analysis of water transfer samples collected during the docked phases of STS-118/13A.1 and STS-120/10A showed that several of the CWCs contained up to 10(exp 4) CFU/mL of bacteria despite the fact that the silver concentrations in the CWCs were within acceptable limits. The samples contained pure cultures of a single bacteria, a Cupriavidus (formerly Wautersia) species that has been shown to be resistant to metallic biocides. As part of the investigation into the cause and remediation of the bacterial contamination in these CWCs, ground studies were initiated to evaluate the resistance of the Cupriavidus species to the silver biocides used on ISS and to determine the minimum effective concentration for the different forms of silver present in the biocides. The initial findings from those experiments are discussed herein.

Gazda, Daniel B.↗

Evaluation of IMERG Satellite Precipitation Over the Land-Coast-Ocean Continuum – Part Ii: Quantification

To understand and manage water systems under a changing climate and meet an increasing demand for water, a quantitative understanding of precipitation is most important in coastal regions. The capabilities of the Integrated Multi-satellitE Retrievals for Global Precipitation Measurement (IMERG) V06B product for precipitation quantification are examined over three coastal regions of the United States: the West Coast, the Gulf of Mexico, and the East Coast, all of which are characterized by different topographies and precipitation climatologies. A novel uncertainty analysis of IMERG is proposed that considers environmental and physical parameters such as elevation and distance to the coastline. The IMERG performance is traced back to its components, i.e., passive microwave (PMW), infrared (IR), and morphing-based estimates. The analysis is performed using high-resolution, high-quality Ground Validation Multi-Radar/Multi-Sensor (GV-MRMS) rainfall estimates as ground reference at the native resolution of IMERG of 30 min and 0.1°. IMERG Final (IM-F) quantification performance heavily depends on the respective contribution of PMW, IR, and morph components. IM-F and its components overestimate the contribution of light rainfall (<1 mm h−1) and underestimate the contribution of high rainfall rates (>10 mm h−1) to the total rainfall volume. Strong regional dependencies are highlighted, especially over the West Coast, where the proximity of complex terrain to the coastline challenges precipitation estimates. Other major drivers are the distance from the coastline, elevation, and precipitation types, especially over the land and coast surface types, that highlight the impact of precipitation regimes.

Atmosphere↗

Development of the Continuous-Fill Brine Evaporation Bag (BEB) System

The existing water recovery system on the International Space Station (ISS) is limited to 70 percent reclamation; consequently, long duration space missions are currently unfeasible due to the large quantity of water necessary to sustain the crew. The Brine Evaporation Bag (BEB) is a proposed system to supplement the existing water recovery system aboard the ISS and future deep space missions that can increase water recovery to 99 percent. The BEB project previously focused on the development of only the bag portion of the system. This paper focuses on the development of the BEB Evaporator. It will discuss the work to understand, optimize, and improve the entire BEB system while implementing a continuous-fill process. The results of that development and the advantages and limitations of the continuous-fill process will be presented.

Water Recovery↗

Development of the Auto-Fill Brine Evaporation Bag (BEB) System

The existing water recovery system on the International Space Station (ISS) is limited to 70 percent reclamation; consequently, long duration space missions are currently unfeasible due to the large quantity of water necessary to sustain the crew. The Brine Evaporation Bag (BEB) is a proposed system to supplement the existing water recovery system aboard the ISS and future deep space missions that can increase water recovery to 99 percent. The BEB project previously focused on the development of only the bag portion of the system. This paper focuses on the development of the BEB Evaporator. It will discuss the work to understand, optimize, and improve the entire BEB system while implementing a continuous-fill process. The results of that development and the advantages and limitations of the continuous-fill process will be presented.

Delzeit, Lance↗

Test and evaluation of a solar-heating system

Report documents results of evaluation tests performed on components of commerical solar heating and hot water system. Subsystems tested include flat plate solar collector, energy transport module, and control panel. Tests conducted include snow and wind loads, flame spread, and smoke classification as well as solar heating operation.

Source record↗

Solar-Heated Water at a Motel--Mobile, Alabama

Solar-assisted hot-water system for a new 122-unit motor inn in Mobile, Alabama, generates more than half the energy needed for hot-water heating at motel each year. System consists of 93 flat-plate collectors, 2,500 gallon (9,500 1) insulated storage tank located outdoors, heat exchangers and controls. Electronic thermometers, measuring the temperatures at 22 locations monitor system performance.

Source record↗

PFAS Removal by Ion Exchange Resins: Background and Knowledge Gaps with Respect to the Hanford Site

Per- and polyfluoroalkyl substances (PFAS) have been a rising concern for the past two decades, with the United States Department of Defense and Environmental Protection Agency investing millions of dollars in research into remediation and clean-up technologies. Due to the environmental persistence, toxicity, biological uptake, and ongoing changes in both federal and state regulatory space, understanding the fate and transport of PFAS compounds has been of growing concern to the US Department of Energy (DOE). The DOE’s Hanford Site is investigating historical use of PFAS and will be doing site characterization for PFAS. Thus, PFAS have not yet been identified as a contaminant concern in regulatory documents. Based on historical records that mention the discharge of aqueous film-forming foam containing PFAS and having on-site fire stations (a risk factor for PFAS contamination), it seems likely that environmental releases of PFAS may have occurred. Pump and treat (P&T) remediation is the selected remedy for multiple groundwater contaminant plumes at Hanford. These P&T systems use ion exchange (IX) as a component of aboveground treatment, with the specific resins depending on the target contaminants. There is potential that these IX resins may be able to remove PFAS from groundwater, but investigation is needed to understand affinity/selectivity and removal capacity given the groundwater composition and the operating conditions. This report provides background on PFAS uses and chemistry, then provides a review of IX resin applications for PFAS, identifying knowledge gaps. Recommendations are provided regarding research needed to address knowledge gaps and acquire information needed to propose IX as a future PFAS remediation technology at the Hanford Site, as well as other U.S. Department of Energy sites. Generally, PFAS compounds are fluorinated substances that contain at least one fully fluorinated methyl or methylene carbon – with a few noted exceptions, any chemical with at least a perfluorinated methyl group (–CF3) or a perfluorinated methylene group (–CF2–) is a PFAS. These chemical compounds are characterized as non-biodegradable, non-reactive, non-photolytic, and hydrolysis resistant. This makes them highly recalcitrant within the environment, however polyfluoroalkyl materials are less recalcitrant as the carbon chains contain C–H bonds which are more easily broken than carbon – fluorine (C–F) bonds. The backbone carbon structures are commonly punctuated with a head group, the most well-known of them are perfluorooctanesulfonic acid and perfluorooctanoic acid, which possess a sulfonate and a carboxylate group, respectively. IX resins are marketed for the removal of PFAS from water systems and industrial water, however, the mechanism of removal is not as well understood as for anion or cation removal. A better understanding of the mechanism of removal would enable the development of IX resins that have improved specificity for PFAS removal. Four knowledge gaps were identified: 1) the effect of dissolved ions on the IX resin PFAS removal effectiveness, 2) the effect of additional primary contaminants of concern (PCOCs) or secondary contaminants of concern (SCOCs) on the effectiveness of PFAS via IX resin, 3) the mechanisms of PFAS removal from water, and 4) practical solutions to IX resin regeneration and waste disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The zero-multipole summation method for estimating electrostatic interactions in molecular dynamics: Analysis of the accuracy and application to liquid systems

In the preceding paper [I. Fukuda, J. Chem. Phys. 139, 174107 (2013)], the zero-multipole (ZM) summation method was proposed for efficiently evaluating the electrostatic Coulombic interactions of a classical point charge system. The summation takes a simple pairwise form, but prevents the electrically non-neutral multipole states that may artificially be generated by a simple cutoff truncation, which often causes large energetic noises and significant artifacts. The purpose of this paper is to judge the ability of the ZM method by investigating the accuracy, parameter dependencies, and stability in applications to liquid systems. To conduct this, first, the energy-functional error was divided into three terms and each term was analyzed by a theoretical error-bound estimation. This estimation gave us a clear basis of the discussions on the numerical investigations. It also gave a new viewpoint between the excess energy error and the damping effect by the damping parameter. Second, with the aid of these analyses, the ZM method was evaluated based on molecular dynamics (MD) simulations of two fundamental liquid systems, a molten sodium-chlorine ion system and a pure water molecule system. In the ion system, the energy accuracy, compared with the Ewald summation, was better for a larger value of multipole moment l currently induced until l ≲ 3 on average. This accuracy improvement with increasing l is due to the enhancement of the excess-energy accuracy. However, this improvement is wholly effective in the total accuracy if the theoretical moment l is smaller than or equal to a system intrinsic moment L. The simulation results thus indicate L ∼ 3 in this system, and we observed less accuracy in l = 4. We demonstrated the origins of parameter dependencies appearing in the crossing behavior and the oscillations of the energy error curves. With raising the moment l we observed, smaller values of the damping parameter provided more accurate results and smoother behaviors with respect to cutoff length were obtained. These features can be explained, on the basis of the theoretical error analyses, such that the excess energy accuracy is improved with increasing l and that the total accuracy improvement within l ⩽ L is facilitated by a small damping parameter. Although the accuracy was fundamentally similar to the ion system, the bulk water system exhibited distinguishable quantitative behaviors. A smaller damping parameter was effective in all the practical cutoff distance, and this fact can be interpreted by the reduction of the excess subset. A lower moment was advantageous in the energy accuracy, where l = 1 was slightly superior to l = 2 in this system. However, the method with l = 2 (viz., the zero-quadrupole sum) gave accurate results for the radial distribution function. We confirmed the stability in the numerical integration for MD simulations employing the ZM scheme. This result is supported by the sufficient smoothness of the energy function. Along with the smoothness, the pairwise feature and the allowance of the atom-based cutoff mode on the energy formula lead to the exact zero total-force, ensuring the total-momentum conservations for typical MD equations of motion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quest for the lowest-energy neutrinos in Super-Kamiokande

Super-Kamiokande (SK) has been observing {sup 8}B solar neutrinos for 17 years. Since the start of the SK-III phase, much effort has been expended in reducing backgrounds. The main contributing background comes from the beta decay of {sup 214}Bi, which is produced in the decays of radon in the purified air, detector materials, and the purified water. To reduce this background, the water system of SK has been upgraded. Heat exchangers for the cooling supply water were improved so as to suppress convection in the tank that transports radon near the photomultiplier tubes into the fiducial volume. To evaluate the remaining radon concentration, very-low-background radon detectors for air and water were designed and developed. Not only radon, but other contaminants in the water (bacteria and metal ions) were also investigated.

54 ENVIRONMENTAL SCIENCES↗