Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Warp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

SU-G-BRC-15: The Potential Clinical Significance of Dose Mapping Error for Intra- Fraction Dose Mapping for Lung Cancer Patients

Purpose: To evaluate the dose-mapping error (DME) inherent to conventional dose-mapping algorithms as a function of dose-matrix resolution. Methods: As DME has been reported to be greatest where dose-gradients overlap tissue-density gradients, non-clinical 66 Gy IMRT plans were generated for 11 lung patients with the target edge defined as the maximum 3D density gradient on the 0% (end of inhale) breathing phase. Post-optimization, Beams were copied to 9 breathing phases. Monte Carlo dose computed (with 2*2*2 mm{sup 3} resolution) on all 10 breathing phases was deformably mapped to phase 0% using the Monte Carlo energy-transfer method with congruent mass-mapping (EMCM); an externally implemented tri-linear interpolation method with voxel sub-division; Pinnacle’s internal (tri-linear) method; and a post-processing energy-mass voxel-warping method (dTransform). All methods used the same base displacement-vector-field (or it’s pseudo-inverse as appropriate) for the dose mapping. Mapping was also performed at 4*4*4 mm{sup 3} by merging adjacent dose voxels. Results: Using EMCM as the reference standard, no clinically significant (>1 Gy) DMEs were found for the mean lung dose (MLD), lung V20Gy, or esophagus dose-volume indices, although MLD and V20Gy were statistically different (2*2*2 mm{sup 3}). Pinnacle-to-EMCM target D98% DMEs of 4.4 and 1.2 Gy were observed ( 2*2*2 mm{sup 3}). However dTransform, which like EMCM conserves integral dose, had DME >1 Gy for one case. The root mean square RMS of the DME for the tri-linear-to- EMCM methods was lower for the smaller voxel volume for the tumor 4D-D98%, lung V20Gy, and cord D1%. Conclusion: When tissue gradients overlap with dose gradients, organs-at-risk DME was statistically significant but not clinically significant. Target-D98%-DME was deemed clinically significant for 2/11 patients (2*2*2 mm{sup 3}). Since tri-linear RMS-DME between EMCM and tri-linear was reduced at 2*2*2 mm{sup 3}, use of this resolution is recommended for dose mapping. Interpolative dose methods are sufficiently accurate for the majority of cases. J.V. Siebers receives funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-06: Dose Calculation in Curved Space

Purpose: Microbeam Radiation Therapy is a preclinical method in radiation oncology that modulates radiation fields on a micrometre scale. Dose calculation is challenging due to arising dose gradients and therapeutically important dose ranges. Monte Carlo (MC) simulations, often used as gold standard, are computationally expensive and hence too slow for the optimisation of treatment parameters in future clinical applications. On the other hand, conventional kernel based dose calculation leads to inaccurate results close to material interfaces. The purpose of this work is to overcome these inaccuracies while keeping computation times low. Methods: A point kernel superposition algorithm is modified to account for tissue inhomogeneities. Instead of conventional ray tracing approaches, methods from differential geometry are applied and the space around the primary photon interaction is locally warped. The performance of this approach is compared to MC simulations and a simple convolution algorithm (CA) for two different phantoms and photon spectra. Results: While peak doses of all dose calculation methods agreed within less than 4% deviations, the proposed approach surpassed a simple convolution algorithm in accuracy by a factor of up to 3 in the scatter dose. In a treatment geometry similar to possible future clinical situations differences between Monte Carlo and the differential geometry algorithm were less than 3%. At the same time the calculation time did not exceed 15 minutes. Conclusion: With the developed method it was possible to improve the dose calculation based on the CA method with respect to accuracy especially at sharp tissue boundaries. While the calculation is more extensive than for the CA method and depends on field size, the typical calculation time for a 20×20 mm{sup 2} field on a 3.4 GHz and 8 GByte RAM processor remained below 15 minutes. Parallelisation and optimisation of the algorithm could lead to further significant calculation time reductions.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-02: An Efficient Atlas-Based Synthetic CT Generation Method

Purpose: A major obstacle for MR-only radiotherapy is the need to generate an accurate synthetic CT (sCT) from MR image(s) of a patient for the purposes of dose calculation and DRR generation. We propose here an accurate and efficient atlas-based sCT generation method, which has a computation speed largely independent of the number of atlases used. Methods: Atlas-based sCT generation requires a set of atlases with co-registered CT and MR images. Unlike existing methods that align each atlas to the new patient independently, we first create an average atlas and pre-align every atlas to the average atlas space. When a new patient arrives, we compute only one deformable image registration to align the patient MR image to the average atlas, which indirectly aligns the patient to all pre-aligned atlases. A patch-based non-local weighted fusion is performed in the average atlas space to generate the sCT for the patient, which is then warped back to the original patient space. We further adapt a PatchMatch algorithm that can quickly find top matches between patches of the patient image and all atlas images, which makes the patch fusion step also independent of the number of atlases used. Results: Nineteen brain tumour patients with both CT and T1-weighted MR images are used as testing data and a leave-one-out validation is performed. Each sCT generated is compared against the original CT image of the same patient on a voxel-by-voxel basis. The proposed method produces a mean absolute error (MAE) of 98.6±26.9 HU overall. The accuracy is comparable with a conventional implementation scheme, but the computation time is reduced from over an hour to four minutes. Conclusion: An average atlas space patch fusion approach can produce highly accurate sCT estimations very efficiently. Further validation on dose computation accuracy and using a larger patient cohort is warranted. The author is a full time employee of Elekta, Inc.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-JeP1-05: Dose Deformation Error Associated with Deformable Image Registration Pathways

Purpose: To evaluate errors associated with using different deformable image registration (DIR) pathways to deform dose from planning CT (pCT) to cone-beam CT (CBCT). Methods: Deforming dose is controversial because of the lack of quality assurance tools. We previously proposed a novel metric to evaluate dose deformation error (DDE) by warping dose information using two methods, via dose and contour deformation. First, isodose lines of the pCT were converted into structures and then deformed to the CBCT using an image based deformation map (dose/structure/deform). Alternatively, the dose matrix from the pCT was deformed to CBCT using the same deformation map, and then the same isodose lines of the deformed dose were converted into structures (dose/deform/structure). The doses corresponding to each structure were queried from the deformed dose and full-width-half-maximums were used to evaluate the dose dispersion. The difference between the FWHM of each isodose level structure is defined as the DDE. Three head-and-neck cancer patients were identified. For each patient, two DIRs were performed between the pCT and CBCT, either deforming pCT-to-CBCT or CBCT-to-pCT. We evaluated the errors associated by using either of these pathways to deform dose. A commercially available, Demons based DIR was used for this study, and 10 isodose levels (20% to 105%) were used to evaluate the errors in various dose levels. Results: The prescription dose for all patients was 70 Gy. The mean DDE for CT-to-CBCT deformation was 1.0 Gy (range: 0.3–2.0 Gy) and this was increased to 4.3 Gy (range: 1.5–6.4 Gy) for CBCT-to-CT deformation. The mean increase in DDE between the two deformations was 3.3 Gy (range: 1.0–5.4 Gy). Conclusion: The proposed DDF was used to quantitatively estimate dose deformation errors caused by different pathways to perform DIR. Deforming dose using CBCT-to-CT deformation produced greater error than CT-to-CBCT deformation.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be a useful tool in image-guided interventions for prostate-cancer diagnosis and treatment.

60 APPLIED LIFE SCIENCES↗

Dynamics of Electronic States and Magnetoabsorption in 3D Topological Insulators in a Quantizing Magnetic Field

Quantum states have been calculated analytically; the dynamics of a wave packet in a magnetic field has been investigated, and the optical absorption coefficient has been calculated for surface states in 3D topological insulators of the Bi{sub 2}Te{sub 3} family. We have detected a qualitative effect of the hexagonal warping of the spectrum on the structure of wavefunctions at the Landau levels, its manifestation in the features of the wave packet dynamics in a quantizing magnetic field, as well as in the frequency dependence of the optical absorption coefficient, in which new peaks that are absent in the isotropic model of the spectrum appear depending on the polarization of the incident wave. The effects considered here can be manifested in the optical and transport experiments with topological insulators, which makes it possible to determine the parameters of their band structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MTV-G experiment: Probing non-standard strong gravitational field at nuclear scale using geodetic precession

A new experiment named MTV-G, probing a large electron spin-precession due to a possible strong gravitational field, which predicted by large extra dimension model, is started at TRIUMF from 2011. In an electron-nuclear scattering experiment, a strong gravitational field is tested as a large spin precession effect caused by geodetic precession predicted by general relativity theory as a result of a warped space-time around nuclei. Experimental design using spin polarized electron source and Mott-spin analyzer, commissioning experiment and the preliminary results are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Elastic Bayesian Model Calibration

Functional data are ubiquitous in scientific modeling. For instance, quantities of interest are modeled as functions of time, space, energy, density, etc. Uncertainty quantification methods for computer models with functional response have resulted in tools for emulation, sensitivity analysis, and calibration that are widely used. However, many of these tools do not perform well when the computer model’s parameters control both the amplitude variation of the functional output and its alignment (or phase variation). This paper introduces a framework for Bayesian model calibration when the model responses are misaligned functional data. The approach generates two types of data out of the misaligned functional responses: (1) aligned functions so that the amplitude variation is isolated and (2) warping functions that isolate the phase variation. These two types of data are created for the computer simulation data (both of which may be emulated) and the experimental data. The calibration approach uses both types so that it seeks to match both the amplitude and phase of the experimental data. The framework is careful to respect constraints that arise, especially when modeling phase variation, and is framed in a way that it can be done with readily available calibration software. In conclusion, we demonstrate the techniques on two simulated data examples and on two dynamic material science problems: a strength model calibration using flyer plate experiments and an equation of state model calibration using experiments performed on the Sandia National Laboratories’ Z-machine.

97 MATHEMATICS AND COMPUTING↗

Search for heavy resonances decaying to two Higgs bosons in final states containing four b quarks

A search is presented for narrow heavy resonances X decaying into pairs of Higgs bosons (H) in proton-proton collisions collected by the CMS experiment at the LHC at $\sqrt{s}$ = 8 TeV. The data correspond to an integrated luminosity of 19.7 fb -1 . The search considers HH resonances with masses between 1 and 3 TeV, having final states of two b quark pairs. Each Higgs boson is produced with large momentum, and the hadronization products of the pair of b quarks can usually be reconstructed as single large jets. The background from multijet and t-tbar events is significantly reduced by applying requirements related to the flavor of the jet, its mass, and its substructure. The signal would be identified as a peak on top of the dijet invariant mass spectrum of the remaining background events. No evidence is observed for such a signal. Upper limits obtained at 95% confidence level for the product of the production cross section and branching fraction $\sigma$(gg → X) B(X → HH → $b\bar{b}b\bar{b}$) range from 10 to 1.5 fb for the mass of X from 1.15 to 2.0 TeV, significantly extending previous searches. For a warped extra dimension theory with a mass scale $\Lambda_R$ = 1 TeV, the data exclude radion scalar masses between 1.15 and 1.55 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for heavy resonances decaying into WW in the $e\nu\mu\nu$ final state in $pp$ collisions at $\sqrt{s}=13$ TeV with the ATLAS detector

A search for neutral heavy resonances is performed in the WW→eνμν decay channel using pp collision data corresponding to an integrated luminosity of 36.1fb -1 , collected at a centre-of-mass energy of 13 TeV by the ATLAS detector at the Large Hadron Collider. No evidence of such heavy resonances is found. In the search for production via the quark–antiquark annihilation or gluon–gluon fusion process, upper limits on σ X ×B(X→WW) as a function of the resonance mass are obtained in the mass range between 200 GeV and up to 5 TeV for various benchmark models: a Higgs-like scalar in different width scenarios, a two-Higgs-doublet model, a heavy vector triplet model, and a warped extra dimensions model. Finally, in the vector-boson fusion process, constraints are also obtained on these resonances, as well as on a Higgs boson in the Georgi–Machacek model and a heavy tensor particle coupling only to gauge bosons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for heavy diboson resonances in semileptonic final states in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

This paper reports on a search for heavy resonances decaying into WW , ZZ or WZ using proton–proton collision data at a centre-of-mass energy of $\sqrt{s}$ = 13 TeV. The data, corresponding to an integrated luminosity of 139 fb -1 , were recorded with the ATLAS detector from 2015 to 2018 at the Large Hadron Collider. The search is performed for final states in which one W or Z boson decays leptonically, and the other W boson or Z boson decays hadronically. The data are found to be described well by expected backgrounds. Upper bounds on the production cross sections of heavy scalar, vector or tensor resonances are derived in the mass range 300–5000 GeV within the context of Standard Model extensions with warped extra dimensions or including a heavy vector triplet. Production through gluon–gluon fusion, Drell–Yan or vector-boson fusion are considered, depending on the assumed model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gaussian null coordinates, near-horizon geometry and conserved charges on the horizon of extremal nondilatonic black p-branes

In this paper, we examine the emergence of conserved charges on the horizon of a particular class of extremal nondilatonic black [Formula: see text]-branes (which reduce to extremal dilatonic black holes in [Formula: see text] dimensions upon toroidal compactification) in the presence of a probe massless scalar field in the bulk. This result is achieved by writing the black [Formula: see text]-brane geometry in a Gaussian null coordinate system which allows us to get a nonsingular near-horizon geometry description. We find that the near-horizon geometry is [Formula: see text] and that the [Formula: see text] section has an internal structure which can be seen as a warped product of [Formula: see text] in Gaussian null coordinates. We show that the bulk scalar field satisfying the field equations is expanded in terms of nonnormalizable and normalizable modes, which for certain suitable quantization conditions are well-behaved at the boundary of [Formula: see text] space. Furthermore, we show that picking the normalizable modes results in the existence of conserved quantities on the horizon. We discuss the impact of these conserved quantities in the late-time regime.

Astronomy & Astrophysics↗

Comment on Sub-15 nm Hard X-Ray Focusing with a New Total-Reflection Zone Plate

Takano et al. report the focusing of 10-keV X-rays to a size of 14.4 nm using a total-reflection zone plate (TRZP). This focal size is at the diffraction limit for the optic's aperture. This would be a noteworthy result, since the TRZP was fabricated using conventional lithography techniques. Alternative nanofocusing optics require more demanding fabrication methods. However, as I will discuss in this Comment, the intensity distribution presented by Takano et al. (Fig. 4 of ref. 1) is more consistent with the random speckle pattern produced by the scattering of a coherent incident beam by a distorted optic than with a diffraction-limited focus. When interpreted in this manner, the true focal spot size is {approx}70 nm: 5 times the diffraction limit. When a coherent photon beam illuminates an optic containing randomly distributed regions which introduce different phase shifts, the scattered diffraction pattern consists of a speckle pattern. Each speckle will be diffraction-limited: the peak width of a single speckle depends entirely on the source coherence and gives no information about the optic. The envelope of the speckle distribution corresponds to the focal spot which would be observed using incoherent illumination. The width of this envelope is due to the finite size of the coherently-diffracting domains produced by slope and position errors in the optic. The focal intensity distribution in Fig. 4 of ref. 1 indeed contains a diffraction-limited peak, but this peak contains only a fraction of the power in the focused, and forms part of a distribution of sharp peaks with an envelope {approx}70 nm in width, just as expected for a speckle pattern. At the 4mm focal distance, the 70 nm width corresponds to a slope error of 18 {micro}rad. To reach the 14 nm diffraction limit, the slope error must be reduced to 3 {micro}rad. Takano et al. have identified a likely source of this error: warping due to stress as a result of zone deposition. It will be interesting to see whether the use of a more rigid substrate gives improved results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance portability study of epistasis detection using SYCL on NVIDIA GPU

We describe the experience of converting a CUDA implementation of a high-order epistasis detection algorithm to SYCL. The goals are for our work to be useful to application and compiler developers with a detailed description of migration paths between CUDA and SYCL. Evaluating the CUDA and SYCL applications on an NVIDIA V100 GPU, we find that the optimization of loop unrolling needs to be applied manually to the SYCL kernel for obtaining comparable performance. The performance of the SYCL group reduce function, an alternative to the CUDA warp-based reduction, depends on the problem and work group sizes. The 64-bit popcount operation implemented with tree of adders is slightly faster than the built-in popcount operation. When the number of OpenMP threads is four, the highest performance of the SYCL and CUDA applications are comparable.

Jin, Zheming↗

openPMD-viewer

Many simulation software produce data in the form of a set of field values or of a set of particle positions. (one such example is that of particle-in-cell codes, which produce data on the electromagnetic fields that they simulate.) However, each particular software uses its own particular format and layout, for the output data. This makes it difficult to compare the results of different simulation software, or to have a common visualization tool for these results. However, a standardized layout for fields and particles has recently been developed: the openPMD format ( HYPERLINK "http://www.openpmd.org/"www.openpmd.org) This format is open- source, and specifies a standard way in which field data and particle data should be written. The openPMD format is already implemented in the particle-in-cell code Warp (developed at LBL) and in PIConGPU (developed at HZDR, Germany). In this context, the proposed software (openPMD-viewer) is a Python package, which allows to access and visualize any data which has been formatted according to the openPMD standard. This package contains two main components: - a Python API, which allows to read and extract the data from a openPMD file, so as to be able to work with it within the Python environment. (e.g. plot the data and reprocess it with particular Python functions) - a graphical interface, which works with the ipython notebook, and allows to quickly visualize the data and browse through a set of openPMD files. The proposed software will be typically used when analyzing the results of numerical simulations. It will be useful to quickly extract scientific meaning from a set of numerical data.

Lehe, Remi↗

Particle-in-cell/accelerator code for space-charge dominated beam simulation

Warp is a multidimensional discrete-particle beam simulation program designed to be applicable where the beam space-charge is non-negligible or dominant. It is being developed in a collaboration among LLNL, LBNL and the University of Maryland. It was originally designed and optimized for heave ion fusion accelerator physics studies, but has received use in a broader range of applications, including for example laser wakefield accelerators, e-cloud studies in high enery accelerators, particle traps and other areas. At present it incorporates 3-D, axisymmetric (r,z) planar (x-z) and transverse slice (x,y) descriptions, with both electrostatic and electro-magnetic fields, and a beam envelope model. The code is guilt atop the Python interpreter language.

Grote, D. P.↗

SPADES (Scalable Parallel Discrete Events Simulation) [SWR-24-99]

SPADES (Solver for PArallel Discrete Event Simulation) is an open-source parallel discrete event simulation (PDES) package built on the AMReX library. Targeted at solving discrete event systems in parallel, this software package aims to be performance portable and scalable on heterogeneous computing architectures, e.g., graphic processing units (GPU). SPADES implements optimistic synchronization with rollback through an implementation of the Time Warp algorithm. An alternative conservative synchronization approach is also implemented using the Lower Bound on Incoming Time Stamp. In our implementation, logical processes are represented as cells in a grid and event messages are represented as particles. SPADES supports various parallel decomposition strategies, including the use of the Message Passing Interface (MPI) and OpenMP threading. All major GPU architectures (e.g., Intel, AMD, NVIDIA) are supported through the use of performance portability functionalities implemented in AMReX. The SPADES software is released in NREL Software Record SWR-24-99 “SPADES (Scalable Parallel Discrete Events Simulation)”.

Henry de Frahan, Marc [National Renewable Energy L↗