Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A computationally efficient P 1 radiation model for modern combustion systems utilizing pre-conditioned conjugate gradient methods

The iterative convergence of the P 1 radiation model can be slow in optically thin scenarios when employing classical iterative methods. In order to remedy this shortcoming, an in-house P 1 radiation model was interfaced with high performance, scalable, linear solver libraries. Next, the accuracies of P 1 radiation model calculations was assessed by comparing its predictions against discrete ordinates (DO) model calculations for prototypical problems representative of modern combustion systems. Corresponding benchmark results were also included for comparison. Utilizing Pre-Conditioners (PC) to the Conjugate Gradients (CG) method, the convergence time of the P 1 radiation model reduced by a factor of 30 for modest problem sizes and a factor of 70 for larger sized problems when compared against classical Gauss Seidel sweeps. Additionally, PC provided 50% computational savings compared to employing CG in a standalone mode. The P 1 model calculation times were about 25–30% of the DO model calculation time. The time to solution also scaled linearly with an increase in problem size. The weighted sum of gray gases model employed in this study in conjunction with the P 1 model provided good agreement against benchmark data with L 2 error norms (defined relative to corresponding DO calculations) improving when isotropic intensities were prevalent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LaNi x Fe 1–x O 3 as flexible oxygen or carbon carriers for tunable syngas production and CO 2 utilization

The current study reports LaFe 1–x Ni x O 3–δ redox catalysts as flexible oxygen or carbon carriers for CO2 utilization and tunable production of syngas at relatively low temperatures (~700 °C), in the context of a hybrid redox process. Specifically, perovskite-structured LaFe 1–x Ni x O 3–δ with seven different compositions (x = 0.4–1) were prepared and investigated. Cyclic experiments under alternating methane and CO 2 flows indicated that all the samples exhibited favorable reactive performance: CH 4 and CO 2 conversions varied between 85% and 98% and 70–88%, respectively. While H 2 /CO ratio from Fe-rich redox catalysts was ~2.3:1 in the methane conversion step, Ni-rich catalysts produced a concentrated (~ 93.7 vol%) hydrogen stream via methane cracking. The flexibility of LaFe 1–x Ni x O 3–δ to produce syngas (or hydrogen) with tunable compositions was found to be governed by the iron/nickel (Fe/Ni) ratio. Redox catalysts with higher Fe contents act as a lattice oxygen carrier via chemical looping partial oxidation (CLPOx) of methane whereas those with higher Ni contents function as a carbon carrier via chemical looping methane cracking (CLMC) scheme. XRD analysis and temperature-programmed reactions revealed that both types of catalysts involve the formation of La 2 O 3 and Ni 0 /Ni-Fe phases under the methane environment. The ability to re-incorporate La 2 O 3 and Ni/Fe into a perovskite structure gives rise to oxygen-carrying capacity whereas stable Ni 0 or Ni/Fe phases would catalyze methane cracking without lattice oxygen exchange in the reaction cycles. Here, temperature programmed oxidation and Raman spectroscopy indicated the presence of graphitic and amorphous carbon species, which were effectively gasified by CO 2 to produce concentrated CO. Stability tests over LaFe 0.5 Ni 0.5 O 3 and LaNiO 3 revealed that the redox performance was stable over a span of 50 cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

20 FOSSIL-FUELED POWER PLANTS↗

Utilization of municipal wastewater for cooling in thermoelectric power plants

A process simulation model has been developed using Aspen Plus® with the OLI (OLI System, Inc.) water chemistry model to predict water quality in the recirculating cooling loop utilizing secondary- and tertiary-treated municipal wastewater as the source of makeup water. Simulation results were compared with pilot-scale experimental data on makeup water alkalinity, loop pH, and ammonia evaporation. The effects of various parameters including makeup water quality, salt formation, NH 3 and CO 2 evaporation mass transfer coefficients, heat load, and operating temperatures were investigated. The results indicate that, although the simulation model can capture the general trends in the loop pH, experimental data on the rates of salt precipitation in the system are needed for more accurate prediction of the loop pH. It was also found that stripping of ammonia and carbon dioxide in the cooling tower can influence the cooling loop pH significantly. The effects of the NH 3 mass transfer coefficient on cooling loop pH appear to be more significant at lower values (e.g., k NH3 < 4×10 -3 m/s) when the makeup water alkalinity is low (e.g., <90 mg/L as CaCO 3 ). The effect of the CO2 mass transfer coefficient was found to be significant only at lower alkalinity values (e.g., k CO2 <4×10 -6 m/s).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Incremental approach for the life-cycle greenhouse gas analysis of carbon capture and utilization

Electro-fuels (e-fuels) are examples of carbon capture and utilization (CCU) hydrocarbon products that are derived from captured carbon dioxide (CO 2 ), while using renewable electricity as the energy feedstock. The environmental impacts of CCU products (e.g., e-fuel) are systematically quantified through life-cycle analysis (LCA). Previous studies evaluating LCA of e-fuels proposed frameworks with an expanded system boundary approach that included the entire supply chain of the production process generating the CO 2 for CCU, in addition to the supply chain of the CCU product. This expanded system boundary approach evaluates two system boundaries, and uses deduction methods to calculate the carbon intensity (CI) of the CCU product (e-fuel). This paper proposes a simpler system boundary using an incremental approach that can calculate identical CI of the CCU product (e-fuel), while avoiding the extensive calculations in the expanded system boundary framework. The proposed incremental approach allocates the burdens of the CO 2 capturing process to the CO 2 feedstock supplying the CCU production process (e.g., e-fuel production). The CI of the captured CO 2 supplied to CCU process is determined by the energy and material requirements for the CO 2 capturing process and transportation to the CCU plant. Thus, the CI of CO 2 supplied to CCU process can be directly linked to the CI of e-fuel without the need to conduct LCA of the preceding process that generates the CO 2 for CCU.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A fractured climate? the political economy of public utility commissions in an age of climate change

Between 1997 and 2005, states that elected their public utility commissioners had an annual percent change in CO{sub 2} emissions that was nearly three times as much as those states that appoint their PUC commissioners. This suggests that developing institutions which provide decision-makers with political independence through an appointment system might be an important element in lowering environmental externalities and preventing future warming of the Earth. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

At a crossroads: modernizing utility infrastructure in a tough credit environment

Given the current state of electric utility creditworthiness, it is reasonable to question whether the industry is ''ready to roll'' from a financial perspective, and to ask what, if anything, should be done about that. Part of the answer will be to find ways to improve the credit quality of the industry over time - with the interest coverage ratio being the most objective measure of credit quality. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utility DSM: off the coasts and into the heartland

Utility demand-side management efforts began on the coasts but have recently spread to the ''heartland.'' The authors review efforts to develop DSM programs and policies in states that are now ramping up programs, identifying key practices that are often linked with progress in states that are new to DSM and discussing the implications for the 18 states that currently lack significant DSM programs. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

From utility disconnection to universal access

By some estimates, 31% of Americans face some sort of “energy insecurity”, but the full extent of the issue and the magnitude of its effect often difficult to quantify. This case study examines disconnection policies in Minnesota and attempts to extrapolate lessons learned for other states and the nation as a whole. The case study concludes with discussion about the relevance of utility shut off to US universal access.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Molten-salt-mediated carbon dioxide capture and superequilibrium utilization with ethane oxidative dehydrogenation

Existing CO 2 -mediated oxidative dehydrogenation (CO 2 -ODH) of ethane has yet to demonstrate >60% single-pass CO yield due to the intrinsic equilibrium limitations. We report a unique approach with mixed molten carbonates as a reaction medium for CO 2 -ODH, which strategically partitions the CO 2 -ODH reactions into gas and molten-salt phases and facilitates integrated CO 2 capture from power plant flue gases. An 89% CO yield was achieved at 770°C, doubling the equilibrium limitation of conventional CO 2 -ODH. The high CO yield in turn enhances ethylene formation. Further characterizations confirmed that molten-salt mediated ODH (MM-ODH) proceeds through a gas-phase cracking and molten-salt mediated reverse water-gas-shift reaction pathway. Based on this understanding, thermodynamic analysis and ab initio molecular dynamics simulations were conducted to develop general principles to optimize the molten-salt reaction medium. Process analyses confirm that MM-ODH has the potential to be significantly more efficient for CO 2 capture and utilization than conventional CO 2 -ODH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthetic Methanol/Fischer–Tropsch Fuel Production Capacity, Cost, and Carbon Intensity Utilizing CO 2 from Industrial and Power Plants in the United States

Captured CO 2 is a potential feedstock to produce fuel/chemicals using renewable electricity as the energy source. In this study, we explored resource availability and synergies by region in the United States and conducted cost and environmental analysis to identify unique opportunities in each region to inform possible regional and national actions for carbon capture and utilization development. This study estimated production cost of synthetic methanol and Fischer–Tropsch (FT) fuels by using CO 2 captured from the waste streams emitted from six industrial [ethanol, ammonia, natural gas (NG) processing, hydrogen, cement, and iron/steel production plants] and two power generation (coal and NG) processes across the United States. The results showed that a total of 1594 million metric ton per year of waste CO 2 can be captured and converted into 85 and 319 billion gallons of FT fuels and methanol, respectively. FT fuels can potentially substitute for 36% of the total petroleum fuels used in the transportation sector in 2018. Technoeconomic analysis shows that the minimum selling prices for synthetic FT fuels and methanol are 1.8–2.8 times the price of petroleum fuel/chemicals, but the total CO 2 reduction potential is 935–1777 MMT/year.

54 ENVIRONMENTAL SCIENCES↗

Methodology to assess “no-touch” building audit software using simulated utility data

Building audits are conducted in many commercial buildings to identify opportunities to reduce energy costs and improve building operation. Because audits require significant effort by building engineers, they are usually only affordable for larger commercial buildings. “No-touch” building audit tools have thus been developed to identify potential savings based on a simplified analysis of building energy consumption patterns via high-level energy data such as monthly utility bills. This paper presents a comprehensive and standardized methodology to evaluate the accuracy of no-touch audit tools in detecting and diagnosing building energy problems and quantifying potential energy savings. The test suite is based on output data from a well-characterized set of building energy models, and the methodology is illustrated by applying it to a representative no-touch building audit tool. Results show that the tool estimates building energy end uses with reasonable accuracy but is less accurate in identifying probably causes of high energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗