Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UTILITY INTERCONNECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Nickel-incorporated Oxide Composites for Fiber-Optic Based Gas Sensing

Numerous high-value applications within the energy sector involve environmental conditions that are incompatible with traditional sensor technology due to degradation of electrical interconnects, packaging, or the sensors themselves. These can include chemically harsh conditions, high temperature operation, or the presence of electromagnetic interference due to high voltage. The fiber optic platform, constructed of robust, electrically insulating glass or single crystal oxides, offers a versatile and often low cost per node solution to this problem, especially with the integration of distributed sensing techniques such as optical time-domain and frequency-domain reflectometry (OTDR, OFDR). A major challenge of gas and chemical sensing on the optical fiber platform is the fabrication of robust and stable sensing materials that interact quickly and reversibly to the presence of the target analytes. In this work, we discuss the utilization of nickel-incorporated oxides on evanescent-field optical fiber sensors for gas sensing under harsh conditions relevant to multiple energy infrastructure applications. This paper will discuss a Ni/GDC (Ni / Gd-doped ceria) based sensing layer targeting conditions relevant for high-temperature (up to at least 800oC) hydrogen sensing applications (e.g., for operation within a solid oxide fuel cell or electrolyzer). The impact of hydrogen at elevated temperatures on the optical properties of Ni/GDC will be shown and the material mechanisms for the optical response will be discussed.

gas sensors↗

Morphogenesis of spin cycloids in a noncollinear antiferromagnet

Pattern formation in spin systems with continuous-rotational symmetry (CRS) provides a powerful platform to study emergent complex magnetic phases and topological defects in condensed-matter physics. However, its understanding and correlation with unconventional magnetic order along with high-resolution nanoscale imaging are challenging. Here, we employ scanning nitrogen vacancy (NV) magnetometry to unveil the morphogenesis of spin cycloids at both the local and global scales within a single ferroelectric domain of (111)-oriented BiFeO 3 , which is a noncollinear antiferromagnet, resulting in formation of a glassy labyrinthine pattern. We find that the domains of locally oriented cycloids are interconnected by an array of topological defects and exhibit isotropic energy landscape predicted by first-principles calculations. We propose that the CRS of spin-cycloid propagation directions within the (111) drives the formation of the labyrinthine pattern and the associated topological defects such as antiferromagnetic skyrmions. Unexpectedly, reversing the as-grown ferroelectric polarization from [$\overline{1}$ $\overline{1}$ $\overline{1}$] to [111] produces a noncycloidal NV image contrast which ¯ could be attributed to either the emergence of a uniformly magnetized state or a reversal of the cycloid polarity. These findings highlight that (111)-oriented BiFeO 3 is not only important for studying the fascinating subject of pattern formation but could also be utilized as an ideal platform for integrating novel topological defects in the field of antiferromagnetic spintronics.

magnetoelectric↗

Electronic Switch Arrays for Managing Microbattery Arrays

Integrated circuits have been invented for managing the charging and discharging of such advanced miniature energy-storage devices as planar arrays of microscopic energy-storage elements [typically, microscopic electrochemical cells (microbatteries) or microcapacitors]. The architecture of these circuits enables implementation of the following energy-management options: dynamic configuration of the elements of an array into a series or parallel combination of banks (subarrarys), each array comprising a series of parallel combination of elements; direct addressing of individual banks for charging/or discharging; and, disconnection of defective elements and corresponding reconfiguration of the rest of the array to utilize the remaining functional elements to obtain the desited voltage and current performance. An integrated circuit according to the invention consists partly of a planar array of field-effect transistors that function as switches for routing electric power among the energy-storage elements, the power source, and the load. To connect the energy-storage elements to the power source for charging, a specific subset of switches is closed; to connect the energy-storage elements to the load for discharging, a different specific set of switches is closed. Also included in the integrated circuit is circuitry for monitoring and controlling charging and discharging. The control and monitoring circuitry, the switching transistors, and interconnecting metal lines are laid out on the integrated-circuit chip in a pattern that registers with the array of energy-storage elements. There is a design option to either (1) fabricate the energy-storage elements in the corresponding locations on, and as an integral part of, this integrated circuit; or (2) following a flip-chip approach, fabricate the array of energy-storage elements on a separate integrated-circuit chip and then align and bond the two chips together.

Mojarradi, Mohammad↗

Petascale Parallelization of the Gyrokinetic Toroidal Code

The Gyrokinetic Toroidal Code (GTC) is a global, three-dimensional particle-in-cell application developed to study microturbulence in tokamak fusion devices. The global capability of GTC is unique, allowing researchers to systematically analyze important dynamics such as turbulence spreading. In this work we examine a new radial domain decomposition approach to allow scalability onto the latest generation of petascale systems. Extensive performance evaluation is conducted on three high performance computing systems: the IBM BG/P, the Cray XT4, and an Intel Xeon Cluster. Overall results show that the radial decomposition approach dramatically increases scalability, while reducing the memory footprint - allowing for fusion device simulations at an unprecedented scale. After a decade where high-end computing (HEC) was dominated by the rapid pace of improvements to processor frequencies, the performance of next-generation supercomputers is increasingly differentiated by varying interconnect designs and levels of integration. Understanding the tradeoffs of these system designs is a key step towards making effective petascale computing a reality. In this work, we examine a new parallelization scheme for the Gyrokinetic Toroidal Code (GTC) [?] micro-turbulence fusion application. Extensive scalability results and analysis are presented on three HEC systems: the IBM BlueGene/P (BG/P) at Argonne National Laboratory, the Cray XT4 at Lawrence Berkeley National Laboratory, and an Intel Xeon cluster at Lawrence Livermore National Laboratory. Overall results indicate that the new radial decomposition approach successfully attains unprecedented scalability to 131,072 BG/P cores by overcoming the memory limitations of the previous approach. The new version is well suited to utilize emerging petascale resources to access new regimes of physical phenomena.

42 ENGINEERING↗

Employing the radiological and nuclear risk assessment methods (RNRAM) for assessing radiological and nuclear detection architectures

The United States Department of Homeland Security’s Domestic Nuclear Detection Office (DNDO) is charged with implementing domestic nuclear detection efforts to protect the U.S. from radiological and nuclear threats. DNDO is also responsible for coordinating the development of the Global Nuclear Detection Architecture (GNDA). DNDO utilizes a unique risk analysis tool to conduct a holistic risk assessment of the GNDA known as the Radiological and Nuclear Risk Assessment Methods (RNRAM). The capabilities of this tool will be used to support internal DNDO analyses and has also been used for other entities such as the International Atomic Energy Agency. The model uses a probabilistic risk assessment methodology and includes the ability to conduct a risk assessment of the effectiveness of layered architectures in the GNDA against an attack by an intelligent, adaptive adversary. This paper overviews the basic structure, capabilities, and use of RNRAM as used to assess different architectures and how various risk components are calculated through a series of interconnected modules. Also highlighted is flexible structure of RNRAM which can accommodate new modules in order to examine a variety of threat detection architectures and concepts.

Brigantic, Robert T.↗

Gas turbine combustor exit piece with hinged connections

An exit piece (66) with an inlet throat (67) that conducts a combustion gas flow (36A) in a path (82) from a combustor (63) to an annular chamber (68) that feeds the first blade section (37) of a gas turbine (26). The exit piece further includes an outlet portion (69) that forms a circumferential segment of the annular chamber. The outlet portion interconnects with adjacent outlet portions by hinges (78A, 78B, 80A, 80B). Each hinge may have a hinge axis (82A, 82B) parallel to a centerline (21) of the turbine. Respective gas flows (36A) are configured by an assembly (60) of the exit pieces to converge on the feed chamber (68) into a uniform helical flow that drives the first blade section with minimal circumferential variations in force.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The IDAES process modeling framework and model library—Flexibility for process simulation and optimization

Abstract Energy systems and manufacturing processes of the 21st century are becoming increasingly dynamic and interconnected, which require new capabilities to effectively model and optimize their design and operations. Such next generation computational tools must leverage state‐of‐the‐art techniques in optimization and be able to rapidly incorporate new advances. To address these requirements, we have developed the Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform, which builds on the strengths of both process simulators (model libraries) and algebraic modeling languages (advanced solvers). This paper specifically presents the IDAES Core Modeling Framework (IDAES‐CMF), along with a case study demonstrating the application of the framework to solve process optimization problems. Capabilities provided by this framework include a flexible, modifiable, open‐source platform for optimization of process flowsheets utilizing state‐of‐the‐art solvers and solution techniques, fully open and extensible libraries of dynamic unit operations models and thermophysical property models, and integrated support for superstructure‐based conceptual design and optimization under uncertainty.

42 ENGINEERING↗

Bulk Power System Flow Control

On July 28, 2023, the Federal Energy Regulatory Commission (FERC) issued Order Number 2023, targeting an improved generation-interconnection process in the United States. FERC Order No. 2023 requires transmission providers to evaluate transmission technologies, other than network expansion, that could provide system improvements and help expand bulk-power system capacity. Transmission providers must consider technologies that would fall under the category of Grid Enhancing Technologies (GETs), which provide capacity-expansion options other than conventional transmission expansion.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Anode Interactions with Coal Gas Contaminants

This report describes efforts to characterize the interactions nickel anodes with phosphorus in coal gas using three different button cell configurations to emphasize particular degradation modes. Important parameters addressed included contaminant concentration, temperature, reaction time, fuel utilization, and current density. In addition, coupon tests in flow-through and flow-by arrangements were conducted to complement cell tests. The studies have involved extensive electrochemical testing using both dc and ac methods. Post-test analyses to determine the composition and extent of nickel modification are particularly important to understanding reactions that have occurred. This report also provides a thermodynamic assessment of contaminant reactions with nickel in a coal gas environment with regard to alteration phase formation. Contaminants addressed were phosphorus, arsenic, sulfur, selenium, and antimony. Phosphorus was found to interact strongly with nickel and result in extensive alteration phase formation, consistent with expectations based on thermodynamic properties. Even in button cell tests where the fuel utilization was low, phosphorus was found to be nearly completely captured by the nickel anode. For anode-supported cells, an important degradation mode involved loss of electronic percolation, the result of nickel phosphide formation, grain growth, and inducement of micro-fractures within the anode support. Even with excessive anode support conversion, electrochemical degradation rates were often very low. This is attributed to a “shadowing effect,” whereby a dense structure such as current leads prevent phosphorus from reacting with the nickel directly underneath. This effect maintains an electrical pathway to the active interface, and allows the cell to operate with minimal degradation until the anode is essentially completely consumed. In a planar stack, ribs on the interconnect plate would be expected to provide this conductive pathway in the event of phosphorus exposure. When phosphorus interactions proceeded to the active interface, most easily observed in tests with electrolyte-supported cells having a thin anode, the electrochemical performance decreased considerably.

01 COAL, LIGNITE, AND PEAT↗

Li-Ion Battery Thermal Characterization for Thermal Management Design

Battery design efforts often prioritize enhancing the energy density of the active materials and their utilization. However, optimizing thermal management systems at both the cell and pack levels is also key to achieving mission-relevant battery design. Battery thermal management systems, responsible for managing the thermal profile of battery cells, are crucial for balancing the trade-offs between battery performance and lifetime. Designing such systems requires accounting for the multitude of heat sources within battery cells and packs. This paper provides a summary of heat generation characterizations observed in several commercial Li-ion battery cells using isothermal battery calorimetry. The primary focus is on assessing the impact of temperatures, C-rates, and formation cycles. Moreover, a module-level characterization demonstrated the significant additional heat generated by module interconnects. Characterizing heat signatures at each level helps inform manufacturing at the design, production, and characterization phases that might otherwise go unaccounted for at the full pack level. Further testing of a 5 kWh battery pack revealed that a considerable temperature non-uniformity may arise due to inefficient cooling arrangements. To mitigate this type of challenge, a combined thermal characterization and multi-domain modeling approach is proposed, offering a solution without the need for constructing a costly module prototype.

25 ENERGY STORAGE↗

The Use of Liquid Isopropyl Alcohol and Hydrogen Peroxide Gas Plasma to Biologically Decontaminate Spacecraft Electronics

Legitimate concern exists regarding sending spacecraft and their associated hardware to solar system bodies where they could possibly contaminate the body's surface with terrestrial microorganisms. The NASA approved guidelines for sterilization as set forth in NPG 8020.12C, which is consistent with the biological contamination control objectives of the Committee on Space Research (COSPAR), recommends subjecting the spacecraft and its associated hardware to dry heat-a dry heat regimen that could potentially employ a temperature of 110(deg)C for up to 200 hours. Such a temperature exposure could prove detrimental to the spacecraft electronics. The stimulated growth of intermetallic compounds (IMCs) in metallic interconnects and/or thermal degradation of organic materials composing much of the hardware could take place over a prolonged temperature regimen. Such detrimental phenomena would almost certainly compromise the integrity and reliability of the electronics. Investigation of sterilization procedures in the medical field suggests that hydrogen peroxide (H202) gas plasma (HPGP) technology can effectively function as an alternative to heat sterilization, especially for heat-sensitive items. Treatment with isopropyl alcohol (IPA) in liquid form prior to exposure of the hardware to HPGP should also prove beneficial. Although IPA is not a sterilant, it is frequently used as a disinfectant because of its bactericidal properties. The use of IPA in electronics cleaning is widely recognized and has been utilized for many years with no adverse affects reported. In addition, IPA is the principal ingredient of the test fluid used in ionic contamination testers to assess the amount of ionic contamination found on the surfaces of printed wiring assemblies. This paper will set forth experimental data confirming the feasibility of the IPA/H202 approach to reach acceptable microbial reduction (MR) levels of spacecraft electronic hardware. In addition, a proposed process flow in which both IPA liquid and HPGP are utilized will be presented in Section 7.0.

microbial reduction↗

Performance of A Real-Time Photon Counting Optical Receiver in the Presence of Emulated Channel Fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Performance of a real-time photon counting optical receiver in the presence of emulated channel fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Pseudomonas aeruginosa : One Health approach to deciphering hidden relationships in Northern Portugal

Abstract Aims Antimicrobial resistance in Pseudomonas aeruginosa represents a major global challenge in public and veterinary health, particularly from a One Health perspective. This study aimed to investigate antimicrobial resistance, the presence of virulence genes, and the genetic diversity of P. aeruginosa isolates from diverse sources. Methods and results The study utilized antimicrobial susceptibility testing, genomic analysis for resistance and virulence genes, and multilocus sequence typing to characterize a total of 737 P. aeruginosa isolates that were collected from humans, domestic animals, and aquatic environments in Northern Portugal. Antimicrobial resistance profiles were analyzed, and genomic approaches were employed to detect resistance and virulence genes. The study found a high prevalence of multidrug-resistant isolates, including high-risk clones such as ST244 and ST446, particularly in hospital sources and wastewater treatment plants. Key genes associated with resistance and virulence, including efflux pumps (e.g. MexA and MexB) and secretion systems (T3SS and T6SS), were identified. Conclusions This work highlights the intricate dynamics of multidrug-resistant P. aeruginosa across interconnected ecosystems in Northern Portugal. It underscores the importance of genomic studies in revealing the mechanisms of resistance and virulence, contributing to the broader understanding of resistance dynamics and informing future mitigation strategies.

de Sousa, Telma↗

4 kW Test of Solid Oxide Electrolysis Stacks with Advanced Electrode-Supported Cells

A new test stand has been developed at the Idaho National Laboratory for multi-kW testing of solid oxide electrolysis stacks. This test stand will initially be operated at the 4 KW scale. The 4 kW tests will include two 60-cell stacks operating in parallel in a single hot zone. The stacks are internally manifolded with an inverted-U flow pattern and an active area of 100 cm2 per cell. Process gases to and from the two stacks are distributed from common inlet/outlet tubing using a custom base manifold unit that also serves as the bottom current collector plate. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. Treated metallic interconnects with integral flow channels separate the cells and electrode gases. Sealing is accomplished with compliant mica-glass seals. A spring-loaded test fixture is used for mechanical stack compression. Due to the power level and the large number of cells in the hot zone, process gas flow rates are high and heat recuperation is required to preheat the cold inlet gases upstream of the furnace. Heat recuperation is achieved by means of two inconel tube-in-tube counter-flow heat exchangers. A current density of 0.3 A/cm2 will be used for these tests, resulting in a hydrogen production rate of 25 NL/min. Inlet steam flow rates will be set to achieve a steam utilization value of 50%. The 4 kW test will be performed for a minimum duration of 1000 hours in order to document the long-term durability of the stacks. Details of the test apparatus and initial results will be provided.

08 HYDROGEN↗

Topolgy Agnostic Hot-Spot Avoidance with InfiniBand

InfiniBand has become a very popular interconnect, due to its advanced features and open standard. Large scale InfiniBand clusters are becoming very popular, as reflected by the TOP 500 supercomputer rankings. However, even with popular topologies like constant bi-section bandwidth Fat Tree, hot-spots may occur with InfiniBand, due to inappropriate configuration of network paths, presence of other jobs in the network and un-availability of adaptive routing. In this paper, we present a hot-spot avoidance layer (HSAL) for InfiniBand, which provides hot-spot avoidance using path bandwidth estimation and multi-pathing using LMC mechanism, without taking the network topology into account. We propose an adaptive striping policy with batch based striping and sorting approach, for efficient utilization of disjoint network paths. Integration of HSAL with MPI, the de facto programming model of clusters, shows promising results with collective communication primitives and MPI applications.

97 MATHEMATICS AND COMPUTING↗

On-demand directional microwave photon emission using waveguide quantum electrodynamics

Routing quantum information between non-local computational nodes is a foundation for extensible networks of quantum processors. Quantum information transfer between arbitrary nodes is generally mediated either by photons that propagate between them or by resonantly coupling nearby nodes. The utility is determined by the type of emitter, propagation channel and receiver. Conventional approaches involving propagating microwave photons have limited fidelity due to photon loss and are often unidirectional, whereas architectures that use direct resonant coupling are bidirectional in principle but can generally accommodate only a few local nodes. Here we demonstrate high-fidelity, on-demand, directional, microwave photon emission. We do this using an artificial molecule comprising two superconducting qubits strongly coupled to a bidirectional waveguide, effectively creating a chiral microwave waveguide. Quantum interference between the photon emission pathways from the molecule generates single photons that selectively propagate in a chosen direction. This circuit will also be capable of photon absorption, making it suitable for building interconnects within extensible quantum networks.

42 ENGINEERING↗

Distribution Storage Networks (Draft Version 0.3)

Distribution storage networks are interconnected distribution-level bulk energy storage devices that function as core infrastructure elements to provide both grid resilience and defense against IoT-based cyber grid security threats. The recognition that these are core grid functions changes how storage of this type valued, financed, and operated as compared to storage for ancillary grid services. Distribution storage networks make use of fast bilateral storage to buffer the grid from edge device-based volatilities; this is the essence of both its resilience capability and its cyber defense capability. These storage networks must be core grid components because resilience is an intrinsic grid characteristic and both it and cyber defense of the distribution grid are the responsibility of the distribution utility.

97 MATHEMATICS AND COMPUTING↗