Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Thermally generated spin current in the topological insulator Bi 2 Se 3

We present measurements of thermally generated transverse spin currents in the topological insulator Bi2Se3, thereby completing measurements of interconversions among the full triad of thermal gradients, charge currents, and spin currents. We accomplish this by comparing the spin Nernst magneto-thermopower to the spin Hall magnetoresistance for bilayers of Bi 2 Se 3 /CoFeB. We find that Bi 2 Se 3 does generate substantial thermally driven spin currents. A lower bound for the ratio of spin current density to thermal gradient is $\frac{J_{s}}{∇_{x}T}$ = (4.9 ± 0.9) × 10 6 ($\frac{ℏ}{2e}$) $\frac{A m^{-2}}{K μm^{-1}}$, and a lower bound for the magnitude of the spin Nernst ratio is -0.61 ± 0.11. The spin Nernst ratio for Bi 2 Se 3 is the largest among all materials measured to date, two to three times larger compared to previous measurements for the heavy metals Pt and W. Strong thermally generated spin currents in Bi 2 Se 3 can be understood via Mott relations to be due to an overall large spin Hall conductivity and its dependence on electron energy.

36 MATERIALS SCIENCE↗

Magnon heat transport in a two-dimensional Mott insulator

Whether or not anomalies in the thermal conductivity in insulating cuprates can be attributed to antiferromagnetic order and magnons in a 2D Mott insulator remains an intriguing open question. To shed light on this issue, we investigate the thermal conductivity $\kappa$ and its relationship with the specific heat $c_v$ in the half-filled 2D single-band Hubbard model, using the numerically exact determinant quantum Monte Carlo algorithm and maximum entropy analytic continuation. At low temperatures where the charge degrees of freedom are gapped-out and $c_v$ exhibits a clear magnon peak, we observe that thermal conductivity $\kappa$ also tends to form a peak at similar temperatures. Reducing temperature further produces a sharp upturn in $\kappa$, associated with an increasing mean-free path. Here we identify this as the high-temperature side of the anomalous peak in insulating cuprates, where the mean-free path eventually is cut-off by other scattering effects, including phonons, disorder, and physical size. Different scattering effects in our model are identified and analyzed in the thermal diffusivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modal analysis and dynamic stresses for acoustically excited Shuttle insulation tiles

The thermal protection system of the Space Shuttle consists of thousands of separate insulation tiles, of varying thicknesses, bonded to the orbiter's surface through a soft strain-isolation pad which is bonded, in turn, to the vehicle's stiffened metallic skin. A modal procedure for obtaining the acoustically induced RMS stress in these comparatively thick tiles is described. The modes employed are generated by a previously developed iterative procedure which converges rapidly for the combined system of tiles and primary structure considered. Each tile is idealized by several hundred three-dimensional finite elements and all tiles on a given panel interact dynamically. Acoustic response results from the present analyses are presented. Comparisons with other analytical results and measured modal data for a typical Shuttle panel, both with and without tiles, are made, and the agreement is good.

Ojalvo, I. U.↗

Aging mechanisms of filled cross-linked polyethylene (XLPE) cable insulation material exposed to simultaneous thermal and gamma radiation

Thermal and simultaneous thermal and gamma radiation aging experiments were conducted on an industry grade cross-linked polyethylene (XLPE) cable insulation material, which is a composite material with XLPE as polymer matrix and various additives and fillers. Reverse engineering was conducted to identify and quantify the material composition given that this information was not revealed by the cable manufacture. Samples were then aged at temperatures of 60, 90, and 115 °C, exposed to gamma radiation for total doses of 0 to 324 kGy, and at dose rates of 0 to 540 Gy/h. Aging mechanisms were studied using various materials characterization techniques including pyrolysis gas chromatography mass spectrometry (Py-GCMS), differential scanning calorimetry (DSC), nuclear magnetic resonance spectroscopy (NMR), and gel-fraction tests. Results show that the flame-retardant components were decomposed into smaller molecules when the material was exposed to gamma radiation, while no changes were observed when the samples were aged thermally without gamma radiation. With exposure to gamma radiation, the crystalline phase of the XLPE were damaged by gamma radiation introducing defects in the crystals, resulting in smaller and less perfect crystals. The dominance of chain scission or chain reformation process largely depends on the chain mobility, which is decided by the aging temperature. Chain scission was seen to dominate when the material was exposed to gamma radiation at 60 °C. Chain cross-linking slightly dominated when the material was exposed to gamma radiation at 90 °C and became more dominant with exposure to gamma radiation at 115 °C. No significant change to the XLPE polymer matrix was observed when the samples were exposed to thermal aging without gamma radiation. Finally, antioxidant is more effective in protecting the XLPE polymer matrix under thermal aging, but less effective with sample exposure to gamma radiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Climate benefits and building energy efficiency gains from improved roofing insulation in cold climates

The high thermal resistivity of polyisocyanurate insulation is attributed to its closed cell structure that is filled with low-thermal-conductivity blowing agent vapor. However, existing polyisocyanurate products exhibit a decrease in their thermal-resistance values at lower temperatures due to the condensation of the blowing agent vapor. Because use of insulation with higher thermal resistivity can lead to improved energy efficiency of commercial buildings, which results in lower operational greenhouse gas emissions, there is a clear need to address this reduced performance at lower temperatures through product innovation.

54 ENVIRONMENTAL SCIENCES↗

Depth-Penetrating Measurements Developed for Thermal Barrier Coatings Incorporating Thermographic Phosphors

The insulating properties of thermal barrier coatings (TBCs) provide highly beneficial thermal protection to turbine engine components by reducing the temperature sustained by those components. Therefore, measuring the temperature beneath the TBC is critical for determining whether the TBC is performing its insulating function. Currently, noncontact temperature measurements are performed by infrared pyrometry, which unfortunately measures the TBC surface temperature rather than the temperature of the underlying component. To remedy this problem, the NASA Glenn Research Center, under the Information Rich Test Instrumentation Project, developed a technique to measure the temperature beneath the TBC by incorporating a thin phosphor layer beneath the TBC. By performing fluorescence decay-time measurements on light emission from this phosphor layer, Glenn successfully measured temperatures from the phosphor layer up to 1100 C. This is the first successful demonstration of temperature measurements that penetrate beneath the TBC. Thermographic phosphors have a history of providing noncontact surface temperature measurements. Conventionally, a thermographic phosphor is applied to the material surface and temperature measurements are performed by exciting the phosphor with ultraviolet light and then measuring the temperature-dependent decay time of the phosphor emission at a longer wavelength. The innovative feature of the new approach is to take advantage of the relative transparency of the TBC (composed of yttria-stabilized zirconia) in order to excite and measure the phosphor emission beneath the TBC. The primary obstacle to achieving depth-penetrating temperature measurements is that the TBCs are completely opaque to the ultraviolet light usually employed to excite the phosphor. The strategy that Glenn pursued was to select a thermographic phosphor that could be excited and emit at wavelengths that could be transmitted through the TBC. The phosphor that was selected was yttria doped with europia (Y2O3:Eu), which has a minor excitation peak at 532 nm (green) and an emission peak at 611 nm (red)--both are wavelengths that exhibit significant transmission through the TBC. The measurements were performed on specimens consisting of a 25- m-thick phosphor layer beneath a 100- m-thick TBC. The 532-nm (green) excitation light was provided by a frequency-doubled YAG:Nd (yttrium-aluminum-garnet:neodymium) laser, and the fluorescence decay time measurements were acquired with a modified Raman microscope. The preceding graph compares the intensity of the phosphor emission of the phosphor layer above the TBC versus that of the phosphor layer beneath the TBC. Although there was considerable attenuation of the phosphor signal (a factor of 30), the phosphor emission at the reduced intensity was more than sufficient to perform fluorescence decay time measurements. The following graph shows the fluorescence lifetime temperature dependency for the Y2O3:Eu phosphor layers both above and below the TBC. These curves show an excellent match and indicate that, despite the attenuation due to the overlying TBC, the phosphor layer beneath the TBC still functions as an effective temperature indicator.

Eldridge, Jeffrey I.↗

Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

Wood, J. J.↗

Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

Wood, Jessica J.↗