Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

On the Efficacy of Repeat Voltage Holds for Conditioning and Calendar Life Testing of Graphite and Silicon Cells

Voltage-hold (V-hold) protocols have shown promise toward calendar lifetime analysis of cells with graphite (Gr) and silicon (Si) anodes. In this work, repeat V-holds are performed on Gr and Si cells paired with lithium iron phosphate cathodes to delineate their beneficial role in formation and conditioning. We find that V-hold at the top of charge supplements constant current cycling in conditioning the cell to higher capacities for both Gr and Si cells after the first V-hold. A reduced order model provides the irreversible capacity proportions of each V-hold. With each repeat V-hold, parasitic loss of lithium to the solid electrolyte interphase (SEI) decreases on both Gr and Si cells. Gr cells show the square-root-of-time capacity loss behavior within 200 h of V-hold, indicative of its fast relaxation and low impact of reference performance test cycles on the SEI growth. Lifetime estimates from repeat V-holds on Gr can reach years. Si exhibits longer transition times from kinetic to diffusion-limited SEI growth, evidenced by the 400 h and 200 h holds showing square-root-of-time and linear behavior, respectively. Lifetime predictions from repeat V-holds on Si only reach 1–2 months, highlighting its limitations. Recommended duration of V-holds for Si cells should be ≥400 h.

25 ENERGY STORAGE↗

Performance of high spatial frequency X-ray transmission gratings

The performance of high spatial frequency 'phased' X-ray transmission gratings developed for the High Energy Transmission Grating Spectrometer on the Advanced X-ray Astrophysics FAcility (AXAF) is examined. The gratings tested here nominally consist of 1-micron-thick gold lines of 0.2 micron period covering approximately 5 sq cm of a polyimide membrane. A table-top setup at MIT employs the gratings in reflection to diffract UV (325 nm) laser light. It is used to measure grating periods and indicates that period variations within and between gratings are a few parts in 10,000. Tests performed at the Marshall Space Flight Center 304 m X-ray Facility using 1.5 keV X-rays in transmission corroborate the UV measurements and demonstrate geometrically-limited resolving powers of E/Delta E about 750. Finally, X-ray transmission tests performed in the MIT 25 m X-ray facility provide measurements of period, line thickness, space-to-period ratio, tilt of grating lines, and efficiency.

Fischbach, K. F.↗

Organic Iodide Sorption from Dilute Gas Streams

Reprocessing used nuclear fuel releases volatile radionuclides, including 129 iodine (I), into the off-gas of a processing plant. Volatile radioiodine could be present in several forms, depending on the chemistry of the process used and the off-gas stream. Inorganic I 2 is expected to be the predominant I species in the dissolver off-gas (DOG), with minor organic iodides present. The bulk of the I is expected to volatilize into the DOG in parts-per-million-level (ppm) concentrations. In contrast, in the vessel off-gas (VOG), most of the volatile I is expected to be found as organic iodides, such as CH 3 I, C 4 H 9 I, and C 12 H 25 I. These species are expected to be present in parts-per-billion-level (ppb) concentrations but require abatement, even at low expected concentrations, to meet regulatory emissions limits in the United States. Historically, studies of I abatement by Ag-functionalized sorbents have focused on inorganic I in the DOG, but in the last few years, more research attention has been given to organic iodides, especially longer chain species, such as C 4 H 9 I, and C 12 H 25 I. This report has three main goals: (1) to present new data generated at Oak Ridge National Laboratory (ORNL) in FY21 on the sorption behavior of organic iodides on AgZ, (2) to summarize and synthesize organic iodide data produced by ORNL and Idaho National Laboratory (INL) over the last 4 years to answer questions on organic iodides behavior outlined in the 2018 joint test plan (Jubin et al. 2018), and (3) to propose a VOG abatement system design that can provide the capture efficiencies required to meet I emission limits. The 2021 ORNL experimental campaign tested the effects of organic iodide speciation and concentration in the off-gas, superficial velocity of the off-gas, and effects of aging on AgZ sorbent capacity. These studies found that the sorption rate of organic iodides by AgZ depends on the hydrocarbon chain length and the concentration in the off-gas. Higher molecular weight organic iodides adsorb to AgZ more slowly than I. At a concentration of 50 ppm concentration in the off-gas, CH 3 I loads 8% slower, C 4 H 9 I loads 20% slower, and C 12 H 25 I loads 40% slower than I. The lowest concentration loading rates calculated were in 5 ppm organic iodide gas streams in which AgZ gained on average 0.14 mg I/g sorbent/hour in the bench scale test system. Thus, longer sorbent beds might be needed to accommodate slower loading rates onto AgZ in lower concentration gas streams. Although sorption rate varies as a function of hydrocarbon chain length, the saturation concentration of the sorbent for these I-bearing species does not vary. Aging AgZ in a humid air stream for 9 months drops the overall sorbent capacity by ~35% for CH 3 I, ~50% for C 4 H 9 I, and ~40% for C 12 H 25 I. This results in a saturation capacity between 35 and 70 mg I/g sorbent for the aged AgZ. In conjunction with recent data produced by INL, these data are used to estimate the mass transfer zone (MTZ) and decontamination factor (DF) for sorbent beds of AgZ. Sorption tests performed with iodide gas concentrations of about 1 ppm and higher at a superficial gas velocity of 10 m/min, indicate that MTZ depths for these conditions tend to range between about 8-20 cm. Tests performed at lower concentrations between 50-90 ppb and at gas superficial velocities of 1, 10, and 20 m/min indicate that the MTZ depth increases with increasing superficial gas velocity. The 20 m/min test indicates that the MTZ for those conditions was at least 22 cm, and doubling the superficial gas velocity from 10 to 20 m/min could roughly double or triple the MTZ depth. Doubling and tripling the bounding MTZ depth of 20 cm for the body of MTZ estimates made at with 10 m/min superficial velocity would extend the MTZ for a superficial velocity of 20 m/min to 40-60 cm. This bounding limit applies to all of the organic iodides that have been tested. These results also indicate that the sorption rate-limiting step is not sensitive to the superficial gas velocity; otherwise the MTZ depth would not have increased approximately in proportion to the increase in the gas superficial velocity. This further suggests that the rate limiting step is not associated with mass transfer of the sorbate to the sorbent surface, or mass transfer of the reaction byproducts from the sorbent surface, but is associated with sorption or chemical reactions on the sorbent surface or in sorbent pores. Deep bed testing at INL has established DFs of >2,000 for I, CH 3 I, and C 4 H 9 I under a range of conditions (Soelberg et al. 2021, Bruffey et al. 2019). DF does not seem to be affected by the concentration of the organic iodide in the gas stream over the range of 1 to 50 ppm. Thus, if the MTZ is accommodated in sorbent bed design for the DOG and VOG, then regulatory DFs will be met. To meet the third objective outlined in this report, these experimental data were used to update an engineering evaluation of the VOG first completed in 2016. The updated VOG design can be found in an accompanying document (Welty et al., 2021; INL- LTD-21-64587). This report finds that the VOG will decrease in both size and complexity, relative to previous designs, and will still meet regulatory requirements for all iodine forms.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Endurance test of helium circulator for HTR-PM - 18531

High-temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) will be built as the world's first pebble-bed type modular HTGR commercial demonstration plant according to Chinese National science and technology program. HTR-PM will be expected to begin generating electricity in the end of 2017 in Shidao bay of China. Helium circulator is one of critical component of HTR-PM, which circulates reactor coolant through the reactor core and steam generators. The helium circulator was designed to be a vertical layout and its rotor was supported by active magnet bearings (AMBs). The whole circulator including motor and cooler was sealed in a pressure vessel. Since it is a large mechanical and electrical equipment and the design is totally advanced integrated with many new technologies, experiment study of helium circulator would be significant for safe and reliable operation of HTR-PM plant in the future. For the lack of engineering experience of this equipment, it was necessary to manufacture a prototype for tests. Meanwhile, Engineering Test Facility- Helium Circulator. ETF-HC was built in Institute of Nuclear and New Energy Technology (INET) for the tests. The prototype is completely same as the real machine for the plant. After prototype fabrication, nitrogen test was firstly conducted in the factory by the manufacturer, designer and users. After successful factory test, the prototype was delivered to INET to be tested in ETF-HC. Although nitrogen simulation test had been completed successfully, helium endurance test has been continually carried out in ETF-HC for one and half years because of several sealing problems caused by helium. After solving all kinds of problem in the field, helium circulator run continuously 50 hours under rated condition. Furthermore, 50 service cycles test was conducted in ETF-HC. More than 500 operation hours was accumulated during endurance test. Throughout the final performance test, a conclusion can be made that the helium circulator performance met the design requirements and its feasibility, availability and reliability was verified. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Inferring subsurface heterogeneity from push-drift tracer tests

In this study, we consider the late-time tailing in a tracer test performed with a push-drift methodology (i.e., quasi-radial injection followed by drift under natural gradient). Numerical simulations of such tests are performed on 1000 multi-Gaussian 2-D log-hydraulic conductivity field realizations of varying heterogeneity, each under eight distinct mean flow directions. The ensemble pdfs of solute return times are found to exhibit power law tails for each considered variance of the log-hydraulic conductivity field, σ$2\atop{ln K}$. The tail exponent is found to relate straightforwardly to σ$2\atop{ln K}$ and, within the parameter space we explored, to be independent of push-phase pumping rate, pumping duration, and local-scale dispersivity. We conjecture that individual push-drift tracer tests in wells with screened intervals much greater than the vertical correlation length of the aquifer will exhibit quasi-ergodicity and that their tail exponent may be used to infer σ$2\atop{ln K}$. Lastly, we calibrate a predictive relationship of this sort from our Monte Carlo study, and apply it to data from a push-drift test performed at a site of approximately known heterogeneity—closely matching the existing best estimate of heterogeneity.

58 GEOSCIENCES↗

Self-Lubricating Bushing Testing for John Day Dam Ka plan Turbine Replacement

The goal of this testing program is to find suitable self-lubricated alternatives to replace the in use oil lubricated grooved-bronze bushing in Kaplan runner hubs that are currently being utilized at John Day Dam operated by the U.S. Army Corps of Engineers (USACE). Scaled bushing testing utilizing a Pacific Northwest National Laboratory designed, fabricated, and operated Bushing Test Stand under the direction and funding from USACE determined that self-lubricated bushings tested appear capable of outperforming the current oil-lubricated bronze bushings. Performance tests are focused on durability which includes cyclic load bearing properties and articulations under various loading scenarios. This testing was performed at nominally 1/5 th scale. A scaling sensitivity analysis determined that scaled testing results apply to prototypic size. This report shows the direct comparison between the current baseline bronze bushing to self-lubricated bushings from various manufacturers. Bushing data like coefficient of friction and bushing material loss (associated with bushing wear) was determined. Self-lubricated bushings tested include products manufactured specifically for hydropower applications by the following companies: Trelleborg, Kamatics, Anonymous, and Tenneco/Deva.

42 ENGINEERING↗

Microgravity Research on the NASA Lewis Learjet Test Facility

Results from preliminary performance tests conducted in an aircraft low-G testbed for nonfree-floating experimental packages have identified several operational variables that directly influence the duration and quality of each trajectory. Flight test measurements were made to identify and quantify the presence of higher-frequency airborne and structureborne noise that may affect the correlation of research data with acceleration levels recorded on trajectory traces.

Boyer, E. O.↗

Results of the 1000 Hour Rotary Microfilter Endurance Test

David Herman gives an overview of the 1000 Hour Rotary Microfilter Endurance Test performed at SRNL. The SpinTek Rotary Microfilter was tested with sludge washing and evaluated using performance metrics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report on FY19 Testing in Support of Integrated EPP-SMT Design Methods Development

Experiments in support of the development of the integrated Elastic–Perfectly Plastic (EPP) analysis and Simplified Model Test (SMT) design methodology continued in FY 2019. Major progress was made in the verification of the newly developed two-bar SMT and single-bar SMT (SBSMT) methods by performing tests on Alloy 617 and SS 316H at high temperatures. Comparable results were achieved when the materials were tested under same conditions using both techniques. Because of its simple test configuration, SBSMT was the preferred testing technique used to evaluate elastic follow-up effect and generate data in support of SMT-based design curves. Evaluation of elastic follow-up was started with testing SS 316H at 815°C using SBSMT in this reporting period. As a result of this effort, the basic procedure and test protocol to provide data in support of the development of SMT-based design curves were established. This report also summarizes recent test results for the pressurization SMT using test articles with key features on Alloy 617 at intermediate strain ranges and at a low temperature of 850°C. Although more test results are needed in order to fully understand the effect of primary load on SMT creep-fatigue (CF) life, the limited test data indicate that the primary load reduced the SMT life at intermediate strain ranges and high temperatures. Recognizing the advantages of the newly developed SBSMT method, a new test geometry was designed to allow the elevation of the primary load effect on SMT CF life with the SBSMT technique. Additionally, selected tests were performed on SS 316H (heat 101076) to provide basic information about the heat of material. The tests performed included high-temperature tensile, fatigue, creep fatigue, and thermomechanical experiments. The results will be used to support the verification of the material constitutive model developed at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

Cold crucible induction melter studies for making glass ceramic waste forms: A feasibility assessment

Glass ceramics are being developed to immobilize fission products, separated from used nuclear fuel by aqueous reprocessing, into a stable waste form suitable for disposal in a geological repository. This work documents the glass ceramic formulation at bench scale and for a scaled melter test performed in a pilot-scale (approximately 1/4 scale) cold crucible induction melter (CCIM). Melt viscosity, electrical conductivity, and crystallization behavior upon cooling were measured on a small set of compositions to select a formulation for melter testing. Property measurements also identified a temperature range for melter operation and cooling profiles necessary to crystallize the targeted phases in the waste form. Bench scale and melter run results successfully demonstrate the processability of the glass ceramic using the CCIM melter technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance and Health Test Procedure for Grid Energy Storage Systems

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: round-trip efficiency, standby losses, response time/accuracy, and useable energy/state of charge at different discharge/charge rates over the system's lifetime. The procedures are divided into reference performance tests, which require the system to be put in a test mode and are to be conducted in intervals, and real-time monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modification and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditure. Simulated results based on a detailed system simulation of a prototype system are provided as guideline.

25 ENERGY STORAGE↗

ASX O-ring Life Testing Using a LAW High Bound Melter Feed Simulant (Final Report)

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is planning to utilize an Isolok sampler to sample the contents of the Low Activity Waste (LAW) and High Level Waste (HLW) Melter Feed Preparation Vessels (MFPV) as well as the contents of the LAW Concentrate Receipt Vessel (CRV). Over the course of testing, it has been recognized that the long term reliability of the o-ring seals in the Isolok sampler are an important component in sampling. The Isolok sampler will be collecting samples of melter feed that contain a high percentage of highly abrasive particles which can impact the life of the o-rings. Although o-ring life in normal service is typically several hundred thousand cycles (such as in the air cylinders and other non-abrasive environments), no data are available for the life of the o-ring seals in this abrasive environment. To address this concern, a Test Exception was issued to perform testing to determine whether the o-rings in an Isolok sampler will continue to function through one year of projected HLW MFPV sampler operation, or approximately 7,000 sampler piston cycles. This final report provides results of the o-ring testing that was performed with the ASX sampler.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically the relative alignment of the lens let array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

Coronagraphic High Angular Resolution Imaging Spec↗

Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.

25 ENERGY STORAGE↗

Single-Event Gate Rupture and Single-Event Burnout Test Results Performed on Hi-Rel Fuji Power MOSFETs: 2SK4217, 2SK4152, 2SK4155, and 2SK4158

Several newly available Hi-Rel total dose hardened power MOSFETs manufactured by Fuji Electric Device Technology Co. Ltd (FDT) in conjunction with the Japan Aerospace Exploration Agency (JAXA) were tested for single-event gate rupture (SEGR) and single-event burnout (SEB). The safe-operating area (SOA) of the 2SK4217 (a 100 V rated device), 2SK4152 (130 V), 2SK4155 (200 V), and the 2SK4158 (250 V) were tested with silver (Ag) and xenon (Xe) ions having incident LETs of 42.2 and 53.1 MeV cm2/mg, respectively. Test results show these devices are comparable to currently available total dose hardened technology.

Selva, Luis E.↗

Orbiter S-band direct link system verification test report

Space-to-ground S-band communications system compatibility and performance tests were performed for the various radio frequency links. These tests consisted of the various uplink and downlink signal combinations (data rates) for the phase modulation system and both realtime and playback data rates for the frequency modulated downlink systems. In addition, tests involving encryption/decryption, Doppler, and acquisition were performed. Results show that the S-band transponder for the space shuttle orbiter is compatible with the S-band equipment of the AFSCF/RTS (Air Force Satellite Control Facility/Remote Tracking Station). It is also concluded that the performance of the orbiter-AFSCF/RTS direct link exceeds the required performance and that this communications link will meet the system requirements of the Space Transportation System.

Vermillion, B. K.↗

Test beam performance measurements for the Phase I upgrade of the CMS pixel detector

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. Here in this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,\mu \mathrm{m}$ and $7.99\pm0.21\,\mu \mathrm{m}$ along the $100\,\mu \mathrm{m}$ and $150\,\mu \mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗