Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

WE-D-17A-04: Magnetically Focused Proton Irradiation of Small Volume Targets

Purpose: To explore the advantages of magnetic focusing for small volume proton irradiations and the potential clinical benefits for radiosurgery targets. The primary goal is to create narrow elongated proton beams of elliptical cross section with superior dose delivery characteristics compared to current delivery modalities (eg, collimated beams). In addition, more general beam shapes are also under investigation. Methods: Two prototype magnets consisting of 24 segments of samarium-cobalt (Sm2Co17) permanent magnetic material adhered into hollow cylinders were manufactured for testing. A single focusing magnet was placed on a positioning track on our Gantry 1 treatment table and 15 mm diameter proton beams with energies and modulation relevant to clinical radiosurgery applications (127 to 186 MeV, and 0 to 30 mm modulation) were delivered to a terminal water tank. Beam dose distributions were measured using a PTW diode detector and Gafchromic EBT2 film. Longitudinal and transverse dose profiles were analyzed and compared to data from Monte Carlo simulations analogous to the experimental setup. Results: The narrow elongated focused beam spots showed high elliptical symmetry indicating high magnet quality. In addition, when compared to unfocused beams, peak-to-entrance depth dose ratios were 11 to 14% larger (depending on presence or extent of modulation), and minor axis penumbras were 11 to 20% smaller (again depending on modulation) for focused beams. These results suggest that the use of rare earth magnet assemblies is practical and could improve dose-sparing of normal tissue and organs at risk while delivering enhanced dose to small proton radiosurgery targets. Conclusion: Quadrapole rare earth magnetic assemblies are a promising and inexpensive method to counteract particle out scatter that tends to degrade the peak to entrance performance of small field proton beams. Knowledge gained from current experiments will inform the design of a prototype treatment nozzle that incorporates similar focusing magnets. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

60 APPLIED LIFE SCIENCES↗

Harnessing Particle Size‐Control and DNA‐Oligo Functionalization in ZIF‐76 for Biological Applications

Abstract Advanced therapeutics require novel nanocarriers to ensure their functionality is preserved during transit. Zeolitic imidazolate frameworks (ZIFs) have emerged as promising materials in this field owing to their combined biocompatibility, high porosity, and tunable chemistry. While a diverse family of ZIFs has been reported, few have been explored beyond the prototypical ZIF‐8. Herein, the size‐controlled synthesis of three distinct ZIF‐76 analogs is demonstrated, overcoming the unique synthetic challenges intrinsic to the lta topology and complex crystallization kinetics associated with the mixed linker approach. This assesses the materials’ platform effectiveness for intracellular delivery first by exploring the structural and colloidal stability in biologically relevant media. To circumvent particle aggregation, fluorescently labeled DNA oligonucleotides are post‐synthetically attached to the ZIF surface. This modification significantly improves the colloidal stability in media and facilitates particle internalization tracking. Finally, the particle‐cell interactions are assessed, revealing rapid cell membrane association with macrophages, but not lung epithelial cells, and ZIF accumulation within macrophages which increased over time. Importantly, this study outlines a generalized approach toward expanding the available library of ZIFs for biological applications, enabling the potential for targeted therapeutic delivery for intracellular infections treatment.

Deneff, Jacob I.↗

A radial time projection chamber for α detection in CLAS at JLab

A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils to measure exclusive nuclear reactions, such as coherent deeply virtual Compton scattering and coherent meson production off 4 He. In 2009, we carried out these measurements using the CEBAF Large Acceptance Spectrometer (CLAS) supplemented by the RTPC positioned directly around a gaseous 4 He target, allowing a detection threshold as low as 12 MeV for 4 He. This work discusses the design, principle of operation, calibration methods and performances of this RTPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SeaQuest spectrometer at Fermilab

The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell–Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

36 MATERIALS SCIENCE↗

Investigation of an implantable dosimeter for single-point water equivalent path length verification in proton therapy

Purpose: In vivo range verification in proton therapy is highly desirable. A recent study suggested that it was feasible to use point dose measurement for in vivo beam range verification in proton therapy, provided that the spread-out Bragg peak dose distribution is delivered in a different and rather unconventional manner. In this work, the authors investigate the possibility of using a commercial implantable dosimeter with wireless reading for this particular application. Methods: The traditional proton treatment technique delivers all the Bragg peaks required for a SOBP field in a single sequence, producing a constant dose plateau across the target volume. As a result, a point dose measurement anywhere in the target volume will produce the same value, thus providing no information regarding the water equivalent path length to the point of measurement. However, the same constant dose distribution can be achieved by splitting the field into a complementary pair of subfields, producing two oppositely ''sloped'' depth-dose distributions, respectively. The ratio between the two distributions can be a sensitive function of depth and measuring this ratio at a point inside the target volume can provide the water equivalent path length to the dosimeter location. Two types of field splits were used in the experiment, one achieved by the technique of beam current modulation and the other by manipulating the location and width of the beam pulse relative to the range modulator track. Eight MOSFET-based implantable dosimeters at four different depths in a water tank were used to measure the dose ratios for these field pairs. A method was developed to correct the effect of the well-known LET dependence of the MOSFET detectors on the depth-dose distributions using the columnar recombination model. The LET-corrected dose ratios were used to derive the water equivalent path lengths to the dosimeter locations to be compared to physical measurements. Results: The implantable dosimeters measured the dose ratios with a reasonable relative uncertainty of 1%-3% at all depths, except when the ratio itself becomes very small. In total, 55% of the individual measurements reproduced the water equivalent path lengths to the dosimeters within 1 mm. For three dosimeters, the difference was consistently less than 1 mm. Half of the standard deviations over the repeated measurements were equal or less than 1 mm. Conclusions: With a single fitting parameter, the LET-correction method worked remarkably well for the MOSFET detectors. The overall results were very encouraging for a potential method of in vivo beam range verification with millimeter accuracy. This is sufficient accuracy to expand range of clinical applications in which the authors could use the distal fall off of the proton depth dose for tight margins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of GRETINA at NSCL

This proposal funded the continued operation of the Gamma-ray Energy tracking Array GRETINA as a user device at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University. This was a continuation and covered the operation from January 1, 2017 to December 31, 2017. Twenty-three experiments were completed with GRETINA at NSCL. GRETINA was installed at the reaction target position of the high-resolution, large-acceptance S800 spectrograph and the program started on October 15, 2017. The campaign capitalized on the opportunities provided by NSCL’s energetic rare isotope beams produced by projectile fragmentation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mu2e Calorimeter Clustering Studies [Slides]

aMu2e (muon-to-electron-conversion), an Intensity Frontier experiment at Fermilab set to begin data taking in 2022, will search for flavor violation in charged leptons with a muon decaying to only an electron without any neutrinos. Protons will be accelerated by the 8GeV proton beam before reaching Mu2e’s production target. From there, pions enter an S-shaped Transport Solenoid and travel through a series of absorbers and collimators to select low-energy negatively charged muons from pion decay that will hit the stopping target. Downstream from the stopping target are a curved straw tracker and two annular disk crystal calorimeters. The signal will be a mono-energetic e- with an energy close to the rest mass of a muon. The Mu2e expected single event sensitivity is 2.87e-17. The complimentary trigger strategy will take advantage of both online track searches from the tracker and calorimeter reconstruction. The trigger requires a rejection factor greater than 100 and m ust make its decision within a 3ms time budget. In order to provide high efficiency on signal events, our calorimeter clustering algorithms must be accurate and meet the timing performance. I will discuss the expected performance of two clustering algorithms: a fast algorithm to be used at the trigger level and a more accurate clustering algorithm to be used in the offline reconstruction. The fast algorithm defines clusters by only selecting crystals adjacent to a high energy crystal seed. The full-blown algorithm can find smaller clusters separated from the main cluster, within a distance and timing window, and combine them into one cluster. We have analyzed the topology of the reconstructed clusters by the two algorithms on events with only a conversion electron and combined signal and background events. The goal of these studies is to improve the performance of the fast algorithm to better reconstruct the cluster energy and work within the strict timing budget.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Autotune E+ Building Energy Models

This paper introduces a novel Autotune methodology under development for calibrating building energy models (BEM). It is aimed at developing an automated BEM tuning methodology that enables models to reproduce measured data such as utility bills, sub-meter, and/or sensor data accurately and robustly by selecting best-match E+ input parameters in a systematic, automated, and repeatable fashion. The approach is applicable to a building retrofit scenario and aims to quantify the trade-offs between tuning accuracy and the minimal amount of ground truth data required to calibrate the model. Autotune will use a suite of machine-learning algorithms developed and run on supercomputers to generate calibration functions. Specifically, the project will begin with a de-tuned model and then perform Monte Carlo simulations on the model by perturbing the uncertain parameters within permitted ranges. Machine learning algorithms will then extract minimal perturbation combinations that result in modeled results that most closely track sensor data. A large database of parametric EnergyPlus (E+) simulations has been made publicly available. Autotune is currently being applied to a heavily instrumented residential building as well as three light commercial buildings in which a de-tuned model is autotuned using faux sensor data from the corresponding target E+ model.

automatic calibration↗

The SeaQuest Spectrometer at Fermilab

The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy of neutron-rich nuclei populated through binary heavy-ion collisions

Neutron-rich nuclei from A = 50 to A = 80 have been studied through multi-nucleon transfer reactions by bombarding {sup 208}Pb and {sup 238}U targets with beams of {sup 48}Ca, {sup 64}Ni, {sup 70}Zn and {sup 82}Se. The gamma-array CLARA coupled to the large-acceptance magnetic spectrometer PRISMA gave unambiguous identification of prompt {gamma} rays belonging to each nucleus. The existence of the N = 32 sub-shell closure has been corroborated through the study of odd V isotopes, whereas a sizable gap at N = 34 has been evidenced from the spectroscopy of {sup 51}Ca and {sup 52}Sc. The evolution of the N = 50 shell closure far from stability has been studied down to Z = 31. With the {sup 48}Ca beam we have applied for the first time the Recoil Distance Dopple Shift technique to measure lifetimes of neutron-rich nuclei populated in multi-nucleon transfer reactions. Effective charges in the fp shell above {sup 48}Ca have been derived. The first implementation of the tracking array AGATA (the so called 'Demon-strator') will be soon coupled to the PRISMA spectrometer at Legnaro. The future prospects with the use of the Demonstrator are also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intracellular imaging of targeted proteins labeled with quantum dots

We developed a new method for imaging the movement of targeted proteins in living cancer cells with photostable and bright quantum dots (QDs). QDs were conjugated with various molecules and proteins, such as phalloidin, anti-tubulin antibody and kinesin. These bioconjugated QDs were mixed with a transfection reagent and successfully internalized into living cells. The movements of individual QDs were tracked for long periods of time. Phalloidin conjugated QDs bound to actin filaments and showed almost no movement. In contrast, anti-tubulin antibody conjugated QDs bound to microtubules and revealed dynamic movement of microtubules. Kinesin showed an interesting behavior whereby kinesin came to be almost paused briefly for a few seconds and then moved once again. This is in direct contrast to the smoothly continuous movement of kinesin in an in vitro assay. The maximum velocity of kinesin in cells was faster than that in the in vitro assay. These results suggest that intracellular movement of kinesin is different from that in the in vitro assay. This newly described method will be a powerful tool for investigating the functions of proteins in living cells.

60 APPLIED LIFE SCIENCES↗

Identification of boosted Higgs bosons decaying into b -quark pairs with the ATLAS detector at 13 TeV

This study describes a study of techniques for identifying Higgs bosons at high transverse momenta decaying into bottom-quark pairs, $H → b\bar{b}$, for proton–proton collision data collected by the ATLAS detector at the Large Hadron Collider at a centre-of-mass energy $\sqrt{\bar{s}}$ = 13 TeV. These decays are reconstructed from calorimeter jets found with the anti-$k_t R$ = 1.0 jet algorithm. To tag Higgs bosons, a combination of requirements is used: b -tagging of $R$ = 0.2 track-jets matched to the large- R calorimeter jet, and requirements on the jet mass and other jet substructure variables. The Higgs boson tagging efficiency and corresponding multijet and hadronic top-quark background rejections are evaluated using Monte Carlo simulation. Several benchmark tagging selections are defined for different signal efficiency targets. The modelling of the relevant input distributions used to tag Higgs bosons is studied in 36 fb -1 of data collected in 2015 and 2016 using $g → b\bar{b}$ and $Z(→ b\bar{b})γ$ event selections in data. Both processes are found to be well modelled within the statistical and systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of antineutrino oscillations using accelerator and atmospheric data in MINOS

The Main Injector Neutrino Oscillation Search (MINOS) is a long baseline experiment that was built for studying the neutrino oscillation phenomena. The MINOS experiment uses high intensity muon neutrino and antineutrino beams created by Neutrinos at the Main Injector facility (NuMI) at the Fermi National Accelerator Laboratory (Fermilab). Neutrino interactions are recorded by two sampling steel-scintillator tracking calorimeters: 0.98\,kton Near Detector at Fermilab, IL and 5.4\,kton Far Detector at the Soudan Underground Laboratory, MN. These two detectors are functionally identical, which helps to reduce the systematic uncertainties in the muon neutrino and antineutrino disappearance measurements. The Near Detector, located 1.04\,km from the neutrino production target, is used to measure the initial beam composition and neutrino energy proximal to the neutrino source. The collected data at the Near Detector is then used to predict energy spectrum in the Far Detector. By comparing this prediction to collected data at the Far Detector, which is 735\,km away from the target, it enables a measurement of a set of parameters that govern the neutrino oscillation phenomenon. \\ \indent The flexibility of the NuMI beam configuration and the magnetization of the MINOS detectors facilitate the identification of $\nu_{\mu}$ and $\bar{\nu}_{\mu}$ charged-current interactions on an event-by-event basis. This enables one to measure neutrino and antineutrino oscillation parameters independently and therefore allows us to test the CPT symmetry in the lepton sector. To enhance the sensitivity of the oscillation parameters measurement, a number of techniques have been implemented. Event classification, shower energy estimation and energy resolution bin fitting, which are described in this dissertation, are three of these techniques. Moreover, the most stringent constraints on oscillation parameters can be achieved by combining multiple data sets. \\ \indent This dissertation reports the measurement of antineutrino oscill! ation parameters using the complete MINOS accelerator and atmospheric data set of charged-current $\bar{\nu}_{\mu}$ events. This set comprises exposures of (i) 3.36\times 10^{20} proton-on-target (POT) in the \bar{\nu}_{\mu}-beam mode, (ii) 10.71\times 10^{20} POT in the \nu_{\mu}-beam mode, and (iii) 37.88 kton yr of atmospheric antineutrinos. The data analysis provides the world's most precise measurement to date on the antineutrino oscillation parameters: $|\Delta \overline{m}^2|=\left( 2.50^{+0.23}_{-0.29}\right) \times 10^{-3} \,eV^2$ and $\sin^2(2\bar{\theta})=0.97^{+0.03}_{-0.08}$. This result is consistent with neutrino oscillation parameters independently measured by MINOS and by others. The difference between antineutrino and neutrino mass-squared splittings is computed to be $|\Delta \overline{m}^2|-|\Delta m^2|=\left(0.13^{+0.23}_{-0.25}\right) \times 10^{-3} \, eV^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept

Purpose: While respiratory motion compensation for magnetic resonance (MR)-guided high intensity focused ultrasound (HIFU) interventions has been extensively studied, the influence of slow physiological motion due to, for example, peristaltic activity, has so far been largely neglected. During lengthy interventions, the magnitude of the latter can exceed acceptable therapeutic margins. The goal of the present study is to exploit the episodic workflow of these therapies to implement a motion correction strategy for slow varying drifts of the target area and organs at risk over the entire duration of the intervention. Methods: The therapeutic workflow of a MR-guided HIFU intervention is in practice often episodic: Bursts of energy delivery are interleaved with periods of inactivity, allowing the effects of the beam on healthy tissues to recede and/or during which the plan of the intervention is reoptimized. These periods usually last for at least several minutes. It is at this time scale that organ drifts due to slow physiological motion become significant. In order to capture these drifts, the authors propose the integration of 3D MR scans in the therapy workflow during the inactivity intervals. Displacements were estimated using an optical flow algorithm applied on the 3D acquired images. A preliminary study was conducted on ten healthy volunteers. For each volunteer, 3D MR images of the abdomen were acquired at regular intervals of 10 min over a total duration of 80 min. Motion analysis was restricted to the liver and kidneys. For validating the compatibility of the proposed motion correction strategy with the workflow of a MR-guided HIFU therapy, an in vivo experiment on a porcine liver was conducted. A volumetric HIFU ablation was completed over a time span of 2 h. A 3D image was acquired before the first sonication, as well as after each sonication. Results: Following the volunteer study, drifts larger than 8 mm for the liver and 5 mm for the kidneys prove that slow physiological motion can exceed acceptable therapeutic margins. In the animal experiment, motion tracking revealed an initial shift of up to 4 mm during the first 10 min and a subsequent continuous shift of ∼2 mm/h until the end of the intervention. This leads to a continuously increasing mismatch of the initial shot planning, the thermal dose measurements, and the true underlying anatomy. The estimated displacements allowed correcting the planned sonication cell cluster positions to the true target position, as well as the thermal dose estimates during the entire intervention and to correct the nonperfused volume measurement. A spatial coherence of all three is particularly important to assure a confluent ablation volume and to prevent remaining islets of viable malignant tissue. Conclusions: This study proposes a motion correction strategy for displacements resulting from slowly varying physiological motion that might occur during a MR-guided HIFU intervention. The authors have shown that such drifts can lead to a misalignment between interventional planning, energy delivery, and therapeutic validation. The presented volunteer study and in vivo experiment demonstrate both the relevance of the problem for HIFU therapies and the compatibility of the proposed motion compensation framework with the workflow of a HIFU intervention under clinical conditions.

60 APPLIED LIFE SCIENCES↗

The CLAS12 drift chamber system

The CEBAF Large Acceptance Spectrometer at 12~GeV (CLAS12) is located in Hall~B, one of the experimental halls at Jefferson Lab. The forward part of CLAS12 is built around a superconducting toroidal magnet. The six coils of the toroid divide the detector azimuthally into six sectors. Each sector contains three multi-layer drift chambers for reconstructing the trajectories of charged particles originating from a fixed target. Each of the 18 planar chambers has two ``superlayers'' of six layers each, with the wires in the two adjacent superlayers oriented at ± 6° stereo angles. Each layer has 112 hexagonal cells spanning a range from about 5° to 40° in polar angle. The six-layer structure provides redundancy in track segment finding and good tracking efficiency even in the presence of some individual wire inefficiency. The design, construction, operation, and calibration methods are described, and estimates of the efficiency and resolution are presented from in-beam measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-DE-BRA-01: Enhancing Radiation Physics Instruction Through Gamification and E-Learning

Purpose: This project sought to “gamify” the instruction of radiation interaction physics concepts for technology students. Gamification applies game mechanics and user interactions in active learning contexts. In one part of this project, a self-guided eModule was developed for conceptual radiation interaction instruction. In a second part, a web-based game, Particle Launch (http://particle-launcher.ist.unomaha.edu), was created to challenge students to quickly apply radiation interaction concepts in a way that is stimulating and motivating. Methods: The eModule, focused on conceptual interaction physics, was designed in Adobe Captivate and incorporates animation, web videos, and assessment questions in order to generate student interest. Navigating the whole module takes 40 minutes for beginners. Assessments after three main sections are comprised of 3–4 questions randomly selected from a question pool. In collaboration with the University of Nebraska at Omaha’s College of Information Science and Technology, the Particle Launch game was created with the Unity gaming engine and designed with a game-play look and feel. The object of the game is to utilize different particles, energies, and directions to destroy a target given a limited number of resources and time to complete the task. A rewards system encourages accurate shots. Results: The eModule part of the project encourages a flipped classroom model in which class time is devoted to application of concepts rather than information-based lectures. Currently, eModule assessments are not tracked but this feature could be incorporated to encourage participation. Furthermore, in a class of five technology students, the game was found to be fun and engaging and had the effect of reinforcing basic concepts from the eModule. Conclusion: Gamification has significant potential to alter medical physics instruction. Game-play feedback is an important part of the learning process. Students found Particle Launch inviting and challenging and further research could help game design. This project was generously supported by the Office of the Vice-Chancellor for Academic Affairs and the University of Nebraska Medical Center.

61 RADIATION PROTECTION AND DOSIMETRY↗

Host Onboarding Tool (HObT) v1.0.0

The Host OnBoarding Tool (Hobt) is a publicly accessible, web-based software designed to organize and share information about microbial hosts under development at the Agile BioFoundry (ABF). It streamlines the assessment, tracking, and sharing of information related to microbial host development and provides a centralized platform where users can rapidly evaluate hosts' readiness for various bio processes. HObT leverages the Tier System, a standardized host development framework that organizes and assesses microbial hosts based on their readiness for biomanufacturing. Each tier outlines key targets—including genetic tools, growth conditions, omics data, and predictive models—needed to transform new or emerging microbes into established production platforms. By applying clear criteria for advancement, the Tier System helps users quickly evaluate each organism's current development status, identify gaps in available knowledge or tools, and prioritize future strain improvement efforts. Through its user-friendly interface, HObT encourages contributions of new data and insights from researchers, fostering collaboration and accelerating host development. By providing structured guidance for microbial strain advancement, HObT and the Tier System support more systematic, rapid, and cost-effective development of non-traditional microbial hosts, ultimately enhancing the efficiency and impact of biomanufacturing research and applications.

Plahar, Hector [Lawrence Berkeley National Laborat↗