Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Thermal Analysis and Thermal Properties of ANPZ and DNDMP

The thermal properties of ANPZ and DNDMP are reported here. These properties were measured upon request for Pantex. The following is a list of measurements requested: Density; Decomposition Energy; Pre-exponential Factor; Activation Energy; and, Thermal Conductivity. We have reported all most in SI units with the expectation that unit conversions can easily be performed by any individual reading this report. In many cases, we have provides more information than requested as it seemed relevant or necessary for performing safety calculations on these materials. The measurement methods and experimental details are described briefly in each section of this report.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Degradation Investigation of Polyurethane Elastomers using Thermal Gravimetric Analysis - Gas Chromatography/Mass Spectrometry

The thermal degradation of two polyurethane elastomers was investigated via thermal gravimetric analysis coupled with gas chromatography/ma ss spectrometry. Decomposition occur s in a multi - step fashion with similar onset temperatures for both materials. Apparent activation energy plots were calculated inside Model - Free Kinetics software and utilized to construct conversion and isothermal conversion tables . These tables predicted material degradation as a function of temperature and time. Isothermal experiments were performed and found to be in good agreement with the predictions made from the Model - Free Kinetic s software package. Volatile products evolved during the multistep decomposition were captured at various times and analyzed using the coupled gas chromatography/mass spectrometry system . This analysis demonstrated strong correlation between the degradation products and known decomposition mechanisms for polyurethanes.

36 MATERIALS SCIENCE↗

Hydrophobic, Thermal-shock Resistant Lightweight Cement Composites in Hybrid Thermal Energy-Storage Geothermal Well System

Under the DOE EERE Geothermal Technology Office (GTO)-funded project in FY 2019-2022, Brookhaven National Laboratory (BNL) aimed to develop hydrophobic thermal-shock resistant lightweight well cement composites suitable for temporarily storing a curtailed hot working fluid incurred from excess geothermal-, solar-, and wind-generated energies in underground reservoirs thermal energy storage sites. This storage energy systems are designed to provide energy during the periods between energy-harvesting and -requiring periods.

15 GEOTHERMAL ENERGY↗

Experimental Validation of Thermal Hydraulic Behavior in Sodium Fast Reactors (SFR) with the Thermal Hydraulic Experimental Test Article (THETA)

Thermal stratification and transition to natural circulation pose two of the largest sources of uncertainty in systems-level modeling of liquid metal-cooled fast reactors. As these phenomena typically develop during transient event sequences, licensing-basis events analyzed using systemslevel models may have considerable uncertainties associated with thermal-hydraulic parameters of the system to account for these phenomena. As a result, the validation basis for these phenomena for systems-level codes is insufficient to fully support the wide range of liquid metal fast reactors being developed in the US. Currently, the most viable path for licensing a design is to take significant conservatisms and maintain sufficiently large safety margins to account for this uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HANFORD DOUBLE SHELL TANK THERMAL AND SEISMIC PROJECT SUMMARY OF COMBINED THERMAL AND OPERATING LOADS WITH SEISMIC ANALYSIS

This report summarizes the results of the Double-Shell Tank Thermal and Operating Loads Analysis (TaLA) combined with the Seismic Analysis. This combined analysis provides a thorough, defensible, and documented analysis that will become a part of the overall analysis of record for the Hanford double-shell tanks (DSTs). The bases of the analytical work presented herein are two ANSYS{reg_sign} finite element models that were developed to represent a bounding-case tank. The TaLA model includes the effects of temperature on material properties, creep, concrete cracking, and various waste and annulus pressure-loading conditions. The seismic model considers the interaction of the tanks with the surrounding soil including a range of soil properties, and the effects of the waste contents during a seismic event. The structural evaluations completed with the representative tank models do not reveal any structural deficiencies with the integrity of the DSTs. The analyses represent 60 years of use, which extends well beyond the current date. In addition, the temperature loads imposed on the model are significantly more severe than any service to date or proposed for the future. Bounding material properties were also selected to provide the most severe combinations. While the focus of the analyses was a bounding-case tank, it was necessary during various evaluations to conduct tank-specific analyses. The primary tank buckling evaluation was carried out on a tank-specific basis because of the sensitivity to waste height, specific gravity, tank wall thickness, and primary tank vapor space vacuum limit. For this analysis, the occurrence of maximum tank vacuum was classified as a service level C, emergency load condition. The only area of potential concern in the analysis was with the buckling evaluation of the AP tank, which showed the current limit on demand of l2-inch water gauge vacuum to exceed the allowable of 10.4 inches. This determination was based on analysis at the design waste temperature of 350 F and the full 60-year corrosion allowance on the tank wall of 0.060 inch. However, analysis at a more realistic temperature of 250 F or corrosion allowance of 0.025 inch results in an acceptable demand/capacity ratio according to the ASME code criteria. Thus, buckling of the primary tank is judged to be unlikely for the current lack of corrosion in the tanks, and the expectation that the maximum waste temperature will not exceed 210 F. The reinforced concrete structure was evaluated as specified by the American Concrete Institute (ACI) code requirements for nuclear safety-related structures (ACI-349). The demand was demonstrated to be lower than the capacity at all locations. Revision 1 is being issued to document changes to the anchor bolt evaluation. RPP-RPT-32237 Rev. 1, Hanford Double-Shell Tank Thermal and Seismic Project-Increased Liquid Level Analysis for 241AP Tank Farms, described changes to the anchor bolt modeling and evaluation which were implemented in response to the independent reviewer's comments. Similar changes have been made in the bounding tank analysis and are documented in RPP-RPT-28968 Rev. 1. The conclusions of the previous releases of this report remain unchanged.

36 MATERIALS SCIENCE↗

Dynamical System Scaling of a Thermocline Thermal Storage System in the Thermal Energy Distribution System (TEDS) Facility

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility in development that aims to emulate the daily interactions among power production industry systems and be capable of receiving real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect the laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (a methodology that enables systems to scale and project or extrapolate datasets to desired environments while conserving the observed transient behavior based on first principles) was applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System. The thermocline system was successfully scaled and a test case was conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facility. The accelerated data were determined as able to conserve the amount of energy stored and the associated test boundary conditions were charge line maximum temperature, charge line velocity, and thermocline maximum temperature at 354 °C, 0.458 m/s, and 418 °C, respectively. The research results represented a case that required signals to be accelerated without altering the stored energy.

Yoshiura, Ramon (ORCID:0000000319781313)↗

DESIGN OF LABORATORY EXPERIMENTS TO STUDY PHOTOIONIZATION FRONTS DRIVEN BY THERMAL SOURCES

This paper analyzes the requirements of a photoionization-front experiment that could be driven in the laboratory, using thermal sources to produce the necessary flux of ionizing photons. It reports several associated conclusions. Such experiments will need to employ the largest available facilities, capable of delivering many kJ to MJ of energy to an X-ray source. They will use this source to irradiate a volume of neutral gas, likely of N, on a scale of a few mm to a few cm, increasing with source energy. For a gas pressure of several to ten atmospheres at room temperature, and a source temperature near 100 eV, one will be able to drive a photoionization front through a system of tens to hundreds of photon mean free paths. The front should make the familiar transition from the so-called R-Type to D-Type as the radiation flux diminishes with distance. The N is likely to reach the He-like state. Preheating from the energetic photons appears unlikely to become large enough to alter the essential dynamics of the front beyond some layer near the surface. For well-chosen experimental conditions, competing energy transport mechanisms are small.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal-vacuum test report for the ultraviolet spectrometer thermal model

Early design studies showed that the UV spectrometer thermal design margins were very small so that an experimental confirmation of the analytical model would be desirable. At that time the prototype unit was scheduled too far downstream to be of value, so a separate thermal model was built for use in verifying the analytical model.

Wingate, C. A., Jr.↗

Space tug thermal control equipment thermal requirements, characteristics, and constraints catalogue: Users guide

This manual details the input instructions to the data bank, and explanation of the program and its output. The data bank was developed in satisfaction of two of the study tasks, the equipment thermal requirement catalog and the equipment characteristics and constraints catalog. The data bank contains 109 components within space tug avionics system. Other systems were not included in the data bank due to the available information, however, with some program modification, other systems could be incorporated into the data bank program. The data bank was developed and checked out and is compatible with the Univac 1108, and the CDC 6500 operating systems. The data contained in the data bank is general in content with emphasis on the component thermal design. The data is applicable to any spacecraft program where the components contained in the data bank can be applied in satisfaction of the system and subsystem requirements.

Ward, T. L.↗