CFD Modeling of Tank Pressurization and Axial Jet Mixing Experiments with and without Non-Condensable Gas in the Ullage

A two-phase CFD model for tank pressurization and following jet mixing of a cryogenic storage tank is presented using VOF approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. The CFD model was validated against pressurization and liquid jet mixing data for a 110-inch diameter tank provided by Bullard. Cases with like-gas and non-condensable gas pressurization are studied. The results of the cases with like-gas pressurization and following mixing are presented first, focusing on the effects of turbulence at the vapor-liquid interface on the tank pressure and phase change rates predictions. The second part of this paper is devoted to testing and validating the CFD model against non-condensable gas pressurization and following mixing. Tank pressures predicted in both cases are compared with each other and with the experimental data.

Computational Fluid Dynamics↗

Validation of Gas-Liquid Sharp Interface Model in Loci-Stream for Propellant Tank Self-pressurization under Normal Gravity

Deep space missions require advances in cryogenic fluid management (CFM) for long term storage of propellants. One of the important phenomena is self-pressurization due to heat leakages into the tank. Managing self-pressurization is one of the key technologies for deep space exploration and long-term space missions. The complex interactions involving natural convection, thermal gradients, turbulence, and phase change near the gas-liquid interface cannot be modeled using reduced order or nodal analysis models, and 3-D CFD analyses are necessary to fully characterize the dynamics. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. In this paper, we discuss modeling approach for self-pressurization in situations where the liquid interface is static and validate NASA MSFC's Loci-Stream CFD solver for predicting self-pressurization in a test tank in normal gravity. This tank was designed to capture quantifiable and accurate data for understanding various two-phase fluid phenomena and to validate modeling tools. Specifically, we demonstrate the capability of the Loci-Stream solver with a two-phase sharp-interface treatment to predict self-pressurization of a tank with an unperturbed gas-liquid interface. This validation highlights the reliability of our modeling approach and our solver to serve as a design and analysis tool for NASA's CFM application needs.

cryogenic fluid management↗

Validation of Loci-Stream for Autogenous Pressurization of Cryogenic Propellant Tank

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

CFM↗

The Potential Effects of Radiation-Caused Tank Heating in Nuclear Thermal Propulsion Applications

Nuclear thermal propulsion (NTP) vehicles provide a strong option for crewed missions to Mars. Such designs which use cryogenic hydrogen as the stored propellant can provide ISP in excess of 850 seconds and thrusts capable of accelerations roughly comparable to typical in-space chemical engines thus enabling shorter travel times and wider mission abort windows. Given those capabilities, NTP engines provide a viable option for travel to Mars. Nonetheless, complications arise as the nuclear reactions in the reactor core not only heat the propellant but also emit radiation which affects components across the vehicle. In particular, the radiation which reaches the propellant tanks can heat the stored cryogenic propellant, altering the temperature of the propellant as it leaves the tank headed to the turbopump. Determining whether that tank heating causes significant heating of the outflowing propellant serves as an important question for any NTP vehicle design. Results show that warm propellant can cause buoyancy-driven fluid motion within the tank and ultimately can be drawn into the outflow from the tank, and thus must be accounted for in analysis and design of NTP vehicles.

Kalen E Braman↗

Validation and Development of a Fast-Running CFD Model for the No-Vent Fill of Liquid Propellant Tank

Cryogenic fluids, while offering higher energy density than storable propellants, present several handling challenges, including gradual boil-off and tank self-pressurization. Transferring these propellants between tanks can be problematic, as the receiving tank's temperature and pressure often lead to flashing and rapid boil-off upon injection. The No-Vent Fill (NVF) technique mitigates these risks by preventing liquid fuel from being expelled overboard. By controlling tank pressure and ensuring appropriate condensation in the ullage region, the NVF process avoids exceeding vent pressure limits. In this study, Loci/STREAM-VOF simulations were compared with data from NASA K-site test runs on a 2.1 cubic meter tank with a bottom orifice under various no-vent fill conditions, including different wall temperatures, flow rates, and inlet liquid temperatures. The effort demonstrated that Loci/STREAM-VOF is capable of quantitatively capturing the important physics of NVF with submerged jets: (1) validation of the liquid-vapor interface turbulence velocity using previous experimental data showed good agreement at different fill levels; (2) validation of the CFD Stanton number for mass transfer provided an adequate mass transfer coefficient range; (3) consistent pressure agreements were found in the pressure history for both cold and warm conditions; and (4) the variations of final pressure with flow rate and inlet liquid temperature were well predicted by the CFD simulation. The application of NVF for low-gravity conditions will be studied in future work.

CFD↗

The Potential Effects of Radiation-Caused Tank Heating in Nuclear Thermal Propulsion Applications

Nuclear thermal propulsion (NTP) vehicles provide a strong option for crewed missions to Mars. Such designs which use cryogenic hydrogen as the stored propellant can provide ISP in excess of 850 seconds and thrusts capable of accelerations roughly comparable to typical in-space chemical engines thus enabling shorter travel times and wider mission abort windows. Given those capabilities, NTP engines provide a viable option for travel to Mars. Nonetheless, complications arise as the nuclear reactions in the reactor core not only heat the propellant but also emit radiation which affects components across the vehicle. In particular, the radiation which reaches the propellant tanks can heat the stored cryogenic propellant, altering the temperature of the propellant as it leaves the tank headed to the turbopump. Determining whether that tank heating causes significant heating of the outflowing propellant serves as an important question for any NTP vehicle design. Results show that warm propellant can cause buoyancy-driven fluid motion within the tank and ultimately can be drawn into the outflow from the tank, and thus must be accounted for in analysis and design of NTP vehicles.

Kalen Braman↗

An Initial Evaluation Of Characterization And Closure Options For Underground Pipelines Within A Hanford Site Single-Shell Tank Farm

The Hanford Site includes 149 single-shell tanks, organized in 12 'tank farms,' with contents managed as high-level mixed waste. The Hanford Federal Facility Agreement and Consent Order requires that one tank farm, the Waste Management Area C, be closed by June 30, 2019. A challenge to this project is the disposition and closure of Waste Management Area C underground pipelines. Waste Management Area C contains nearly seven miles of pipelines and 200 separate pipe segments. The pipelines were taken out of service decades ago and contain unknown volumes and concentrations of tank waste residuals from past operations. To understand the scope of activities that may be required for these pipelines, an evaluation was performed. The purpose of the evaluation was to identify what, if any, characterization methods and/or closure actions may be implemented at Waste Management Area C for closure of Waste Management Area C by 2019. Physical and analytical data do not exist for Waste Management Area C pipeline waste residuals. To develop estimates of residual volumes and inventories of contamination, an extensive search of available information on pipelines was conducted. The search included evaluating historical operation and occurrence records, physical attributes, schematics and drawings, and contaminant inventories associated with the process history of plutonium separations facilities and waste separations and stabilization operations. Scoping analyses of impacts to human health and the environment using three separate methodologies were then developed based on the waste residual estimates. All analyses resulted in preliminary assessments, indicating that pipeline waste residuals presented a comparably low long-term impact to groundwater with respect to soil, tank and other ancillary equipment residuals, but exceeded Washington State cleanup requirement values. In addition to performing the impact analyses, the assessment evaluated available sampling technologies and pipeline removal or treatment technologies. The evaluation accounted for the potential high worker risk, high cost, and schedule impacts associated with characterization, removal, or treatment of pipelines within Waste Management Area C for closure. This assessment was compared to the unknown, but estimated low, long-term impacts to groundwater associated with remaining waste residuals should the pipelines be left "as is" and an engineered surface barrier or landfill cap be placed. This study also recommended that no characterization or closure actions be assumed or started for the pipelines within Waste Management Area C, likewise with the premise that a surface barrier or landfill cap be placed over the pipelines.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LABORATORY TESTING TO SIMULATE VAPOR SPACE CORROSION IN RADIOACTIVE WASTE STORAGE TANKS

Radioactive liquid waste has been stored in underground carbon steel tanks for nearly 70 years at the Hanford nuclear facility. Vapor space corrosion of the tank walls has emerged as an ongoing challenge to overcome in maintaining the structural integrity of these tanks. The interaction between corrosive and inhibitor species in condensates/supernates on the tank wall above the liquid level, and their interaction with vapor phase constituents as the liquid evaporates from the tank wall influences the formation of corrosion products and the corrosion of the carbon steel. An effort is underway to gain an understanding of the mechanism of vapor space corrosion. Localized corrosion, in the form of pitting, is of particular interest in the vapor space. CPP testing was utilized to determine the susceptibility of the steel in a simulated vapor space environment. The tests also investigated the impact of ammonia gas in the vapor space area on the corrosion of the steel. Vapor space coupon tests were also performed to investigate the evolution of the corrosion products during longer term exposures. These tests were also conducted at vapor space ammonia levels of 50 and 550 ppm NH{sub 3} (0.005, and 0.055 vol.%) in air. Ammonia was shown to mitigate vapor space corrosion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System Performance Testing of the Pulse-Echo Ultrasonic Instrument for Critical Velocity Determination during Hanford Tank Waste Transfer Operations - 13584

The delivery of Hanford double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) is governed by specific Waste Acceptance Criteria that are identified in ICD 19 - Interface Control Document for Waste Feed. Waste must be certified as acceptable before it can be delivered to the WTP. The fluid transfer velocity at which solid particulate deposition occurs in waste slurry transport piping (critical velocity) is a key waste acceptance parameter that must be accurately characterized to determine if the waste is acceptable for transfer to the WTP. Washington River Protection Solutions and the Pacific Northwest National Laboratory have been evaluating the ultrasonic PulseEcho instrument since 2010 for its ability to detect particle settling and determine critical velocity in a horizontal slurry transport pipeline for slurries containing particles with a mean particle diameter of ≥14 micrometers (μm). In 2012 the PulseEcho instrument was further evaluated under WRPS’ System Performance test campaign to identify critical velocities for slurries that are expected to be encountered during Hanford tank waste retrieval operations or bounding for tank waste feed. This three-year evaluation has demonstrated the ability of the ultrasonic PulseEcho instrument to detect the onset of critical velocity for a broad range of physical and rheological slurry properties that are likely encountered during the waste feed transfer operations between the Hanford tank farms and the WTP.

Critical Velocity↗

Hanford Double-Shell Tank AY-102 Radioactive Waste Leak Investigation Update - 15302

Tank AY-102 was the first of 28 double-shell radioactive waste storage tanks constructed at the U. S. Department of Energy’s Hanford Site, near Richland, WA. The tank was completed in 1970, and entered service in 1971. In August, 2012, an accumulation of material was discovered at two sites on the floor of the annulus that separates the primary tank from the secondary liner. The material was sampled and determined to originate from the primary tank. This paper summarizes the changes in leak behavior that have occurred during the past two years, inspections to determine the capability of the secondary liner to continue safely containing the leakage, and the initial results of testing to determine the leak mechanism.

Washenfelder, D. J.↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Results for the January 2023 Semiannual Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the January 2023 Semiannual sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained.1 The chemical and radionuclide contaminant results from the characterization of the January 2023 semiannual sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR)2 and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP).3 This Technical Report is part of Deliverable 2 relating to Task 1 from the SRMC request.2 Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRMC request will be obtained semiannually for the January 2023 and July 2023 Tank 50 samples.

Crawford, Charles L.↗

System Performance Testing of the Pulse-Echo Ultrasonic Instrument for Critical Velocity Determination during Hanford Tank Waste Transfer Operations - 13584

The delivery of Hanford double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) is governed by specific Waste Acceptance Criteria that are identified in ICD 19 - Interface Control Document for Waste Feed. Waste must be certified as acceptable before it can be delivered to the WTP. The fluid transfer velocity at which solid particulate deposition occurs in waste slurry transport piping (critical velocity) is a key waste acceptance parameter that must be accurately characterized to determine if the waste is acceptable for transfer to the WTP. Washington River Protection Solutions and the Pacific Northwest National Laboratory have been evaluating the ultrasonic PulseEcho instrument since 2010 for its ability to detect particle settling and determine critical velocity in a horizontal slurry transport pipeline for slurries containing particles with a mean particle diameter of =14 micrometers (μm). In 2012 the PulseEcho instrument was further evaluated under WRPS' System Performance test campaign to identify critical velocities for slurries that are expected to be encountered during Hanford tank waste retrieval operations or bounding for tank waste feed. This three-year evaluation has demonstrated the ability of the ultrasonic PulseEcho instrument to detect the onset of critical velocity for a broad range of physical and rheological slurry properties that are likely encountered during the waste feed transfer operations between the Hanford tank farms and the WTP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Regulatory Framework for Salt Waste Disposal and Tank Closure at the Savannah River Site - 13663

The end of the Cold War has left a legacy of approximately 37 million gallons of radioactive waste in the aging waste tanks at the Department of Energy's Savannah River Site (SRS). A robust program is in place to remove waste from these tanks, treat the waste to separate into a relatively small volume of high-level waste and a large volume of low-level waste, and to actively dispose of the low-level waste on-site and close the waste tanks and associated ancillary structures. To support performance-based, risk-informed decision making and to ensure compliance with all regulatory requirements, the U.S. Department of Energy (DOE) and its current and past contractors have worked closely with the South Carolina Department of Health and Environmental Control (SCDHEC), the U.S. Environmental Protection Agency (EPA) and the Nuclear Regulatory Commission (NRC) to develop and implement a framework for on-site low-level waste disposal and closure of the SRS waste tanks. The Atomic Energy Act of 1954, as amended, provides DOE the authority to manage defense-related radioactive waste. DOE Order 435.1 and its associated manual and guidance documents detail this radioactive waste management process. The DOE also has a requirement to consult with the NRC in determining that waste that formerly was classified as high-level waste can be safely managed as either low-level waste or transuranic waste. Once DOE makes a determination, NRC then has a responsibility to monitor DOE's actions in coordination with SCDHEC to ensure compliance with the Title 10 Code of Federal Regulations Part 61 (10CFR61), Subpart C performance objectives. The management of hazardous waste substances or components at SRS is regulated by SCDHEC and the EPA. The foundation for the interactions between DOE, SCDHEC and EPA is the SRS Federal Facility Agreement (FFA). Managing this array of requirements and successfully interacting with regulators, consultants and stakeholders is a challenging task but ensures thorough and thoughtful processes for disposing of the SRS low-level waste and the closure of the tank farm facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inspection Tools for Hanford Tanks and Waste Transport Systems - 20444

Recent integrity issues in the double-shell tanks (DST) at Hanford have motivated the need for developing innovative tools that can provide information regarding the health of the tanks. These issues include the primary linear failure of AY-102 and recent concerns of thinning in the DST secondary liners. Other concerns include erosion or corrosion on transfer lines and processing pipes. In recent years, Florida International University (FIU) has supported DOE-EM by developing tools that can assist in understanding the health of tanks and waste transport system at Hanford. More specifically, FIU has developed a miniature rover that can be deployed through small risers and gain access to refractory slots in the Hanford DSTs. It traverses through the slots on the primary liner upside down via magnets to avoid debris in the slots. Recent modifications include a spring loaded magnetic arm that allows the unit to traverse over large weld seams but does not reduce the overall functionality of the system. The system has also incorporated a control capsule that will sit within the annulus of the tank and improves on issues related to signal and voltage loss over long tether lines. Lastly, the unit is also being augmented with a second module that will include a means to prep the tank surface and obtain a thickness measurement using a dual element ultrasonic sensor. FIU has also developed a 6-inch peristaltic pipe crawler that operates similar to the previous pipe crawlers developed at FIU. This crawler is a marsupial type crawler that will navigate through the 6-inch drain lines, and deploy a small rover at the entrance of the drain slots. This rover will also traverse upside down on the secondary liner and provide information regarding the health of the liner. An initial prototype for the crawler unit has been developed, assembled and tested. The system is pneumatic and consists of three modules - two grippers and one extender. The validation tests are conducted in a mockup of the drain lines and demonstrate the system's ability to navigate through long pipe lengths and elbows. In this paper, a general overview of each of the aforementioned systems is presented along with results from testing and demonstrations that shows the applicability of each system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of tank 7 surface supernatant sample (FTF-7-15-26) in support of corrosion control program

This report provides the results of analyses on Savannah River Site Tank 7 surface supernatant liquid sample in support of the Corrosion Control Program (CCP). The measured nitrate, nitrite and free-hydroxide concentrations for the Tank 7 surface sample averaged, 3.74E-01 ± 1.88E-03, 4.17E-01 ± 9.01E-03 and 0.602 ± 0.005 M, respectively. The Tank 7 surface cesium-137, sodium and silicon concentrations were, respectively, 3.99E+08, ± 3.25E+06 dpm/mL, 2.78 M and <3.10 mg/L. The measured aluminum concentration in the Tank 7 surface sample averaged 0.11 M.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 42H

The Savannah River National Laboratory (SRNL) Atmospheric Technologies Group performed atmospheric dispersion modeling and analysis of mercury emissions from the H-Tank Farm - Tank 42 ventilation system exhaust to evaluate potential worker exposures to mercury vapor. This analysis was used to establish a minimum stack height at which ambient mercury concentration would not exceed any worker exposure limit. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. Results indicate that the default 10-foot stack results in ground level concentrations that significantly exceed exposure standards for the mercury discharge scenarios evaluated. For a discharge of 25 mg/m 3 , a 50-foot stack was necessary to raise the exhaust plume centerline from Tank 42H to a height that prevents mercury exposure problems for elevated receptors on buildings near the tank. If the discharge concentration is decreased to 10 mg/m 3 , the minimum stack height required to comply with exposure limits is of 40 feet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 14H Preliminary Cease Waste Removal Sample Analyses

Savannah River Mission Completion Waste Removal and Tank Closure requested that Savannah River National Laboratory perform characterization analyses of Tank 14H in support of closure activities, specifically preliminary cease waste removal. This report provides important characterization of the prepared filtrate and air-dried solids in the January 2026 Tank 14H sample, HTF-14-26-1,2,3,4,5,6, for I-129, Tc-99, Cs-137, and Sr-90. The results reported here were utilized by SRMC to declare preliminary cease waste removal for Tank 14H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗