Commercialization of the Transportation-Security, Tracking, and Reporting System (T-STAR)

The Transportation-Security, Tracking, and Reporting System (T-STAR) was developed by the National Nuclear Security Administration, NA-21, Office of Radiological Security (ORS) to provide a transportation security system for detection and tracking during transport of Category 1 and Category 2 radiological material. Few off-the-shelf systems for conveyance tracking offer detection of a cargo compartment breach or a removal of the cargo. Systems that do offer this capability often require permanent installation through modifying of the conveyance itself. This is not sustainable in many countries where ORS is building use, storage, and transport security capacity. The development of T-STAR has moved from fielding robust prototypes deployed in countries ranging from North America, Latin America and Central Asia to a commercially produced product that can now be deployed to provide enhanced security during transit. Each prototype deployment resulted in important lessons learned, which informed the requirements for the final commercial product. T-STAR uses both cellular and Iridium satellite modems to provide redundant communications to provide the configuration, status, and alerts to a server monitoring the shipment, which is accessible using a multilanguage browser-based user interface. A wireless security system employing using Z-wave sensors for intrusion detection located in the conveyance provide low cost but effective solution for a wide range of conveyance types. Additional capabilities include the ability to monitor a vehicles’ CANBUS (Controller Area Network) system, an ethernet port for high throughput sensor information such as video cameras, and the ability to power and use advanced external sensor payloads. These features make the T-STAR a capable and expandable security gateway that can be deployed on a variety of conveyances from box trucks to open trailers. The ability to provide tracking, monitoring, and detection provide a key component in overall best practices designed to protect shipments of radioactive material.

Schultze, Michael [ORNL] (ORCID:0000000283205671)↗

Chapter 2: Evaluating a Concentrating Solar Power Plantas an Extended-Duration Peaking Resource

We explore the ability of a concentrating solar power (CSP) plant with thermal energy storage (TES) to provide peaking capacity. We focus on future power systems, wherein net load patterns may be significantly different than they are today (e.g., due to higher renewable-energy penetrations). We examine 28 locations in the southwestern United States over an 18-year period. The hourly operation of the CSP plants are simulated to determine their potential to provide energy during an eight-hour peak-load window for each day up to 365 days per year. Our result shows that for the large majority of locations and years, CSP plants with certain configurations (i.e., in terms of solar field and TES sizes) can provide nearly 100% peak-load capacity. We examine also the amount of supplemental energy (e.g.,by using natural gas as a supplemental thermal-energy source) that would be required to ensure that a CSP plant could serve the eight highest-load hours of every day of the year. We find that in most cases, a CSP plant supplemented with natural gas would require less than 5% of the fuel that is used by a natural-gas fired power plant providing the same level of reliable capacity. A series of sensitivity analyses show that these results are robust to the number of peak-load hours and days that are considered and the configuration of the CSP plant.

capacity value↗

Nationwide cost and capacity estimates for sedimentary basin geothermal power and implications for geologic CO 2 storage

Sedimentary basins are naturally porous and permeable subsurface formations that underlie approximately half of the United States. In addition to being targets for geologic CO 2 storage, these resources could supply geothermal power: sedimentary basin geothermal heat can be extracted with water or CO 2 and used to generate electricity. The geothermal power potential of these basins and the accompanying implication for geologic CO 2 storage are, however, understudied. Here, we use the Sequestration of CO 2 Tool (SCO2T PRO ) and the generalizable GEOthermal techno-economic simulator (genGEO) to address this gap by a) estimating the cost and capacity of sedimentary basin geothermal power plants across the United States and b) comparing those results to nationwide CO 2 sequestration cost and storage potential estimates. We find that across the United States, using CO 2 as a geothermal heat extraction fluid reduces the cost of sedimentary basin power compared to using water, and some of the lowest cost capacity occurs in locations not typically considered for their geothermal resources (e.g., Louisiana, South Dakota). Additionally, using CO 2 effectively doubles the sedimentary basin geothermal resource base, equating to hundreds of gigawatts of new capacity, by enabling electricity generation in geologies that are otherwise (with water) too impermeable, too thin, too cold, or not deep enough. We find there is competition for the best sedimentary basin resources between water- and CO 2 -based power, but no overlap between the lowest-cost resources for CO 2 storage and CO 2 -based power. In this way, our results suggest that deploying CO 2 -based power may increase the cost of water based systems (by using the best resources) and the cost of CO 2 storage (by storing CO 2 in locations that otherwise may not be targeted). As such, our findings demonstrate that determining the best role for sedimentary basins within the energy transition may require balancing tradeoffs between competing priorities.

CPG↗

Storage Futures Study: Four Phases Framework and Modeling

This webinar, presented by Paul Denholm and Will Frazier, incorporates material from two publications of the NREL Storage Futures Study: "The Four Phases of Storage Deployment: A Framework for the Expanding Role of Storage in the U.S. Power System" (https://www.nrel.gov/docs/fy21osti/77480.pdf) and "Storage Futures Study: Economic Potential of Diurnal Storage in the U.S. Power Sector" (https://www.nrel.gov/docs/fy21osti/77449.pdf).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Peaking Potential of Long-Duration Energy Storage in the United States Power System

In this work, we investigated the peaking potential for storage with durations of 4 h up to durations of 168 h (1 week). The peaking potential for a given storage duration is the amount of storage that can be added to a power system before that storage can no longer serve the peak net demand period at full rated capacity. We found that for the United States, 168 h of storage would be sufficient to serve about 27 % of peak demand, or about 215 GW in the current system. However, more than one-half of this amount could be served by storage with 12 h or less of capacity. As deployment of wind and solar grows, the peaking potential increases significantly, and under decarbonization scenarios, approximately one-half of the peak demand could be served by storage of up to 168 h; but again, the majority of this storage could be with durations of up to 12 h. The potential is also driven by the mix of wind and solar, and by storage efficiency, with the deployment of solar having the largest impact for both storage peaking potential and the mix of durations.

capacity expansion↗

Energy storage and thermal control system design status

The Space Station Freedom electric power system (EPS) will initially rely on photovoltaics for power generation and Ni/H2 batteries for electrical energy storage. The current design for and the development status of two major subsystems in the PV Power Module is discussed. The energy storage subsystem comprised of high capacity Ni/H2 batteries and the single-phase thermal control system that rejects the excess heat generated by the batteries and other components associated with power generation and storage is described.

Simons, Stephen N.↗

Dynamic Considerations for Control of Closed Life Support Systems

Reliability of closed life support systems depend on their ability to continue supplying the crew's needs during perturbations and equipment failures. The dynamic considerations interact with the basic static design through the sizing of storages, the specification of excess capacities in processors, and the choice of system initial state. A very simple system flow model was used to examine the possibilities for system failures even when there is sufficient storage to buffer the immediate effects of the perturbation. Two control schemes are shown which have different dynamic consequences in response to component failures.

Babcock, P. S.↗

Techno-Economic Analysis of Recuperated Joule-Brayton Pumped Thermal Energy Storage

This article describes a techno-economic model for pumped thermal energy storage systems based on recuperated Joule-Brayton cycles and two-tank liquid storage. Models have been developed for each component, with particular emphasis on the heat exchangers. Economic metrics such as the power and energy capital costs (i.e., per-kW and per-kWh capacity) and levelized cost of storage are evaluated by gathering numerous cost correlations from the literature, thereby enabling estimates of uncertainty. It is found that the use of heat exchangers with effectivenesses up to 0.95 is economically worthwhile, but higher values lead to rapidly escalating component size and system cost. Several hot storage fluids are considered; those operating at the highest temperatures (chloride salts) improve the round-trip efficiency but the benefit is marginal and may not warrant the additional material costs and risk when compared to lower-temperature nitrate salts. Cost-efficiency trade-offs are explored using a multi-objective optimization algorithm, yielding optimal designs with round-trip efficiencies in the range 59-72% and corresponding levelized storage costs of 0.12 0.03 and 0.38 0.10 $/kWhe. Lifetime costs are competitive with lithium-ion batteries for discharging durations greater than 6 h under current scenarios.

Carnot battery↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of variable renewable power generation increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can bridge the intermittency of increasing variable renewable energy (VRE) and facilitate emission-free dispatchable electricity to improve the resilience of the grid and provide reliable and potentially cost-effective energy. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Electro-thermal energy storage (ETES) can store a large capacity of energy with site flexibility and has attracted significant interest for LDES purposes. This paper shows the progress of developing a demonstration test facility for particle ETES technology including pilot-scale component design and fabrication.

25 ENERGY STORAGE↗

Ice-slurry production for solar-ice systems using supercooling with an in-stream crystallizer

Using ice slurry produced from supercooled water with an in-stream crystallizer opens a new path for solarice systems, increasing efficiency and reducing investment cost compared to ice-on-coil systems. Power needs are decoupled from the stored energy since the heat exchangers are not evenly distributed in the ice storage vessel but directly placed as the heat pump evaporator, which depends on the heat pump capacity and not on the ice storage volume. The novel ice storage design can serve as a heat source for a heat pump, where its evaporator is used to supercool water below 0 °C, or for refrigeration. The supercooled water at a temperature around −2 °C, maintained in a meta-stable liquid state, is triggered to nucleate in an in-stream crystallizer. The current design of the ice crystallizer allows for continuous operation of the system and scalability. Experimental results obtained with a gasketed plate heat exchanger used to supercool water and an in-stream crystallizer operated at a power of up to 6.5 kW are presented.

Thamm, Ann-Katrin↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Annealing in Argon Universally Upgrades the Na‐Storage Performance of Mn‐Based Layered Oxide Cathodes by Creating Bulk Oxygen Vacancies

Abstract Manganese‐rich layered oxide cathodes of sodium‐ion batteries (SIBs) are extremely promising for large‐scale energy storage owing to their high capacities and cost effectiveness, while the Jahn–Teller (J–T) distortion and low operating potential of Mn redox largely hinder their practical applications. Herein, we reveal that annealing in argon rather than conventional air is a universal strategy to comprehensively upgrade the Na‐storage performance of Mn‐based oxide cathodes. Bulk oxygen vacancies are introduced via this method, leading to reduced Mn valence, lowered Mn 3 d‐ orbital energy level, and formation of the new‐concept Mn domains. As a result, the energy density of the model P2‐Na 0.75 Mg 0.25 Mn 0.75 O 2 cathode increases by ≈50 % benefiting from the improved specific capacity and operating potential of Mn redox. The Mn domains can disrupt the cooperative J–T distortion, greatly promoting the cycling stability. This exciting finding opens a new avenue towards high‐performance Mn‐based oxide cathodes for SIBs.

Chemistry↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Using hydrogen and ammonia for renewable energy storage: A geographically comprehensive techno-economic study

Hydrogen and, more recently, ammonia have received worldwide attention as energy storage media. In this work we investigate the economics of using each of these chemicals as well as the two in combination for islanded renewable energy supply systems in 15 American cities representing different climate regions throughout the country. We use an optimal combined capacity planning and scheduling model which minimizes the levelized cost of energy (LCOE) by determining optimal unit selection and size along with unit commitments, production rates, and storage inventories for each period of system operation. These periods are aggregated from full year hourly resolution data via a consecutive temporal clustering algorithm. Ammonia is generally more economical than hydrogen as a single method of energy storage. Additionally, systems which use both hydrogen and ammonia outperform those which use only one storage option and have LCOE between $\$ 0.17$/kWh and $\$ 0.28$/kWh, including full investment in renewable generation infrastructure.

25 ENERGY STORAGE↗

Repository of HydroSMADE: Hydropower Site-level Monthly Availability Data Ensemble for 1950-2100 at Existing and Potential Global Sites

This repository presents HydroSMADE—Hydropower Site-level Monthly Availability Data Ensemble, a new open dataset that provides monthly hydropower availability for 1,593 existing and 124,333 potential sites worldwide over the period 1950–2100. The dataset is generated by using a global hydrologic model (Xanthos) with explicit representation of hydropower operation. Specifically, HydroSMADE distinguishes between storage and diversion sites, applies optimized operating rules, and incorporates site-specific characteristics such as generation capacity, maximum turbine flow, and reservoir storage. Driven by bias-corrected meteorological inputs, the data is provided for 30 alternative future scenarios. The scenarios consist of the full factorial combination of three standard CMIP6 atmospheric forcing pathways (SSP1-2.6, SSP3-7.0, and SSP5-8.5) and ten CMIP6 General Circulation Models (GCMs): GFDL-ESM4, IPSL-CM6A-LR, MPI-ESM1-2-HR, MRI-ESM2-0, EC-Earth3, CanESM5, MIROC6, CNRM-ESM2-1, UKESM1-0-LL, and CNRM-CM6-1. The repository contains a total of 122 files: a text file (readme.txt) containing a brief description of the included data, a CSV file containing site attributes, and the remaining 120 files (in CSV) containing site-level monthly hydropower availability. Example Jupyter Notebooks to explore the HydroSMADE dataset are available on GitHub at https://github.com/kamal0013/HydroSMADE More details on the methods and technical validation of HydroSMADE are available in the following paper by the same authors: Chowdhury, A. K., Abeshu, G. W., Zhao, M., Wild, T. B., Hassan, N., Ying, Z., Kim, G. J., Matthew, B., Jonathan, L., & Li, H.-Y. (Submitted). Hydropower Site-level Monthly Availability Data Ensemble for 1950-2100 at Existing and Potential Global Sites.

Existing and Potential Sites↗

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

Ni-MH storage test and cycle life test

Gates Aerospace Batteries is conducting two long term test programs to fully characterize the NiMH cell technology for aerospace applications. The first program analyzes the effects of long term storage upon cell performance. The second program analyzes cycle life testing and preliminary production lot testing. This paper summarizes these approaches to testing the NiMH couple and culminates with initial storage and testing recommendations. Long term storage presents challenges to deter the adverse condition of capacity fade in NiMH cells. Elevated but stabilized pressures and elevated but stabilized end-of-charge voltages also appear to be a characteristic phenomenon of long term storage modes. However, the performance degradation is dependent upon specific characteristics of the metal-hydride alloy. To date, there is no objective evidence with which to recommend the proper method for storage and handling of NiMH cells upon shipment. This is particularly critical due to limited data points that indicate open circuit storage at room temperature for 60 to 90 days will result in irrecoverable capacity loss. Accordingly a test plan was developed to determine what method of mid-term to long-term storage will prevent irrecoverable capacity loss. The explicit assumption is that trickle charging at some rate above the self-discharge rate will prevent the irreversible chemical changes to the negative electrode that result in the irrecoverable capacity loss. Another premise is that lower storage temperatures, typically 0 C for aerospace customers, will impede any negative chemical reactions. Three different trickle charge rates are expected to yield a fairly flat response with respect to recoverable capacity versus baseline cells in two different modes of open circuit. Specific attributes monitored include: end-of-charge voltage, end-of-charge pressure, mid-point discharge voltage, capacity, and end-of-discharge pressure. Cycle life testing and preliminary production lot testing continue to dominate the overall technology development effort at GAB. The cell life test program reflects continuing improvements in baseline cell designs. Performance improvements include lower and more stable charge voltages and pressures. The continuing review of production lot testing assures conformance to the design criteria and expectations. This is especially critical during this period of transferring technology from research and development status to production.

Dell, R. Dan↗