Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Standardization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

The uses and limitations of HF standard broadcasts for time and frequency comparison

The most practical methods of using high-frequency (HF) broadcasts for frequency and time comparison are reviewed. Although standard broadcast and receiving equipment has improved vastly throughout the past fifty years, the HF propagation medium is no more stable today than it was a half century ago. Doppler shift resulting from changes in the effective height of the ionosphere typically limits the usable accuracy of received high frequencies to a few parts in 10 to the 7th power. At locations beyond groundwave range of the transmitter, uncertainties in path delay generally restrict the usable accuracy of HF time signals to the order of a millisecond. Signal-averaging techniques are sometimes employed to extract frequency or time signals from a noisy background.

Stanley, J. T.↗

Some services of the Time and Frequency Division of the National Bureau of Standards

The Time and Frequency Division of the National Bureau of Standards (NBS) provides several services to the general public. The radio broadcasts of WWV, WWVH, and WWVB supply reliable, unambiguous time signals to many users. The NBS telephone time-of-day service attracts several hundreds of thousands of calls each year. Periodically, the NBS provides courses on specific topics relating to time and frequency technology. In addition to numerous technical papers published each year, the NBS has prepared the first volume of a comprehensive monograph on time and frequency. The results of research in the Time and Frequency Division of the NBS have had significant impact. An active TV time system capable of serving most of the U.S. currently awaits a ruling by the FCC on a petition filed last year on behalf of the NBS by the Department of Commerce. Three more recent developments are: (1) a TV frequency comparator (patent applied for); (2) a method to perform an independent (absolute) frequency evaluation of commercial cesium beam oscillators; and (3) a method of removing one source of frequency drift in commercial cesium beam oscillators.

Barnes, J. A.↗

Characteristics of advanced hydrogen maser frequency standards

In house research and development at Goddard Space Flight Center to provide advanced frequency and time standards for the most demanding applications is concentrated primarily in field operable atomic hydrogen masers. Some of the most important goals for the new maser designs have been improved long and short term stability, elimination of the need for auto tuning, increased maser oscillation level, improved hydrogen economy, increased operational life, minimization of operator control or monitoring, improvement in magnetic isolation or sensitivity, and reduction in size and weight. New design concepts which have been incorporated in these masers to achieve these goals are described. The basic maser assemblies and control systems have recently been completed; the masers are oscillating; and operational testing has begun. Data illustrating the improvements in maser performance was available and presented.

Peters, H. E.↗

Apollo 16 photographic standards documentation

The activities of the Photographic Technology Division, and particularly the Photo Science Office, the Precision Processing Laboratory, and the Motion Picture Laboratory, in connection with the scientific photography of the Apollo 16 manned space mission are documented. Described are the preflight activities involved in establishing a standard process for each of the flight films, the manned in which flight films were handled upon arrival at the Manned Spacecraft Center in Houston, Texas, and how the flight films were processed and duplicated. The tone reproduction method of duplication is described. The specific sensitometric and chemical process controls are not included.

Bourque, P. F.↗

Pilot Performance During A Simulated Standard Instrument Procedure Turn With and Without A Predictor Display

A simulator study was conducted to measure the effectiveness of predictor information incorporated into a CRT display of a computer simulated aircraft's horizontal and vertical situation. Professional pilots served as subjects for the task of executing a standard instrument procedure turn at constant altitude in constant crosswinds with and without their predicted ground track displayed. The results show that the display with the predicted ground track was markedly and significantly superior to the display without this information and that the subjects were generally satisfied with this type of information. Mean rms lateral path error was independent of the crosswind velocity with the predictor information, and increased without it with increasing wind velocity. Rms stick activity decreased with the predictor display which also uncoupled aileron and elevator activity.

John G Kreifeldt↗

Standardized multiple output power supply

A comprehensive program to develop a prototype model of a standardized multiple output power supply for use in space flight applications is described. The prototype unit was tested and evaluated to assure that the design would provide near optimum performance for the planned application. The prototype design used a dc-to-dc converter incorporating reqenerative current feedback with a time-ratio controlled duty cycle to achieve high efficiency over a wide variation of input voltage and output loads. The packaging concept uses a mainframe capable of accommodating up to four inverter/regulator modules with one common input filter and housekeeping module. Each inverter/regulator module provides a maximum of 100 watts or 10 amperes. Each module is adaptable to operate at any voltage between 4.0 volts and 108 volts. The prototype unit contains +5, + or - 15 and +28 volt modules.

Ragusa, E. V.↗

Frequency standards requirements of the NASA deep space network to support outer planet missions

Navigation of Mariner spacecraft to Jupiter and beyond will require greater accuracy of positional determination than heretofore obtained if the full experimental capabilities of this type of spacecraft are to be utilized. Advanced navigational techniques which will be available by 1977 include Very Long Baseline Interferometry (VLBI), three-way Doppler tracking (sometimes called quasi-VLBI), and two-way Doppler tracking. It is shown that VLBI and quasi-VLBI methods depend on the same basic concept, and that they impose nearly the same requirements on the stability of frequency standards at the tracking stations. It is also shown how a realistic modelling of spacecraft navigational errors prevents overspecifying the requirements to frequency stability.

Fliegel, H. F.↗

Station coordinates in the standard earth 3 system and radiation-pressure perturbations from ISAGEX camera data

Simultaneous and individual camera observations of GEOS 1, GEOS 2, Pageos, and Midas 4 obtained during the International Satellite Geodesy Experiment are utilized to determine station coordinates. The Smithsonian Astrophysical Observatory Standard Earth III system of coordinates is used to tie the geometrical network to a geocentric system and as a reference for calculating satellite orbits. A solution for coordinates combining geometrical and dynamical methods is obtained, and a comparison between the solutions and terrestrial data is made. The radiation-pressure and earth-albedo perturbations for Pageos are very large, and Pageos' orbits are used to evaluate the analytical treatment of these perturbations. Residual effects, which are probably of interest to aeronomists, remain in the Pageos orbits.

Gaposchkin, E. M.↗

Wind tunnel investigation of a Centaur standard shroud compartment vent from Mach number of 0.70 to 1.96

An experimental investigation was conducted in the Lewis Research Center 8- by 6-foot supersonic wind tunnel to determine the vent discharge coefficient for the Centaur standard shroud/liquid hydrogen tank compartment vent. The test was conducted from Mach 0.70 to 1.96 with the vent mounted in a flat plate. Full scale simulated flight hardware, such as the vent, corrugations, aft field joint ring and ice bag clip was used. Air was discharged from a plenum chamber, located on the tunnel sidewall behind the plate, through five 6.35 cm diameter vent orifices into the free stream. Boundary layer thickeners, analytically predicted displacement thickness for the vehicle nominal flight trajectory could be simulated over the Mach number range. The highest vent discharge coefficient for any given Mach number and vent pressure ratio generally occurred at the maximum displacement thickness.

Johns, A. L.↗

Improved ultrasonic standard reference blocks

A program to improve the quality, reproducibility and reliability of nondestructive testing through the development of improved ASTM-type ultrasonic reference standards is described. Reference blocks of aluminum, steel, and titanium alloys were considered. Equipment representing the state-of-the-art in laboratory and field ultrasonic equipment was obtained and evaluated. Some RF and spectral data on ten sets of ultrasonic reference blocks were taken as part of a task to quantify the variability in response from nominally identical blocks. Techniques for residual stress, preferred orientation, and microstructural measurements were refined and are applied to a reference block rejected by the manufacturer during fabrication in order to evaluate the effect of metallurgical condition on block response.

Eitzen, D. G.↗

Water Hyacinths for Upgrading Sewage Lagoons to Meet Advanced Wastewater Treatment Standards, Part 1

Water hyacinths, Eichhornia crassipes Mart. Solms, have demonstrated the ability to function as an efficient and inexpensive final filtration system in a secondary domestic sewage lagoon during a three month test period. These plants reduced the suspended solids, biochemical oxygen demanding substances, and other chemical parameters to levels below the standards set by the state pollution control agency. The water hyacinth-covered secondary lagoon utilized in this experiment had a surface area of 0.28 hectare (0.70 acre) with a total capacity of 6.8 million liters (1.5 million gallons), receiving an inflow of 522,100 liters (115,000 gallons) per day from a 1.1 hectare (3.8 acre) aerated primary sewage lagoon. These conditions allowed a retention time of 14 to 21 days depending on the water hyacinth evapotranspiration rates. The desired purity of final sewage effluent can be controlled by the water hyacinth surface area, harvest rate, and the retention time.

Wolverton, B. C.↗

Landsat US standard catalog

The U.S. Standard Catalog lists imagery of the continental U.S., Alaska and Hawaii acquired by Landsat 1 and 2 which has been processed and input to the data files during the referenced month. Data, such as date acquired, cloud cover and image quality are given for each scene. The microfilm roll and frame on which the scene may be found is also given.

Source record↗

Landsat non-US standard catalog

The Non-U.S. Standard Catalog lists Non-U.S. imagery acquired by Landsat 1 and 2 which was processed and input to the data files during the referenced month. Data, such as date acquired, cloud cover and image quality are given for each scene. The microfilm roll and frame on which the scene may be found are also given.

Source record↗

Centaur Standard Shroud (CSS) Heated Altitude Jettison Tests

Altitude jettison tests, at a pressure of 20 torr (0.39 psia), were performed on the Centaur Standard Shroud (CSS) in a 100-foot diameter vacuum chamber. These jettison tests were part of a series of flight qualification tests which were performed on the new CSS system in preparation for the Helios and Viking missions. The first two tests subjected the CSS to a thermal cycle which simulated aerodynamic heating during ascent flight and the third test was performed at altitude pressure and in ambient temperature conditions. The purpose of the ambient temperature test was to provide base line data by which the separate machanical and thermal factors that influence jettison performance could be evaluated individually. The CSS was successfully jettisoned in each of the three tests. Also, thermal, stress, and structural deflection data were obtained which verified the analytical predictions of CSS response to flight environmental conditions and performance during jettison. In addition, much important information was obtained on critical CSS-to-payload clearance losses due to shell motions prior to and during jettison. The effectiveness of the separation system was successfully demonstrated at maximum flight temperatures.

Source record↗

A suggested classification system for standard on-orbit shuttle flight phases

The definition of standard flight segments of phases, representing flight profile components which can be combined in various sequences to satisfy particular objectives, is a necessity for simplifying operational procedures and for minimizing the cost of flight planning, software development, and training. The critical elements are (1) a greater variety of generic segment types that may be incorporated into a given flight profile, (2) a greater variability of the order in which segments may be combined to construct a particular flight profile, and (3) a greater variation of detail within a given generic segment type. All of these variations arise basically from shuttle payload characteristics. They are manifested in a number of ways, including changes in the shuttle configuration from one flight to another.

Wilson, S. W.↗

LANDSAT Non-US standard catalog, 1-31 December 1975

The Non-U.S. Standard Catalog lists Non-U.S. imagery acquired by LANDSAT 1 and 2 which has been processed and input to the data files during the referenced month. Data, such as date acquired, cloud cover and image quality are given for each scene. The microfilm roll and frame on which the scene may be found is also given.

Source record↗