Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Ka-band feed arrays for spacecraft reflector antennas with limited scan capability: An overview

JPL and NASA are in the process of developing ground and spacecraft antenna systems at Ka-band frequencies for future deep space applications. The use of Ka-band (32-GHz down) communication will result in smaller ground and spacecraft antennas and associated equipment, and will provide larger bandwidths necessary for very high data rate communication and radio navigation. In this article, the use of a small phased array as a feed for a reflector antenna system with limited scan capability is addressed. Different feed and antenna configurations, as well as array architectures, are examined. Some theoretical and experimental parameters of a particular breadboard feed array developed by JPL and the University of Massachusetts are presented. Guidelines for the future direction of this effort are provided.

Jamnejad, V.↗

Scanning with charge-coupled devices

Results are presented of an investigation of six modes of using CCDs for searches of gamma-ray bursters, debris in geosynchronous space, satellites of asteroids, brown dwarfs, the tenth planet, comets, cometesimals, and various types of asteroids. A new discipline in astrophysics, 'scannerscopy', i.e., surveying with a CCD rather than with photography at a Schmidt telescope, is described. It uses the CCD in scanning rather than in sequencing of stare exposures as is done at most observatories, which can save telescope time and obviates the need for flat-fielding. Attention is given to the Tektronix 2048 x 2048 CCD, 38 arcmin wide, which is used to a limiting magnitude of 20.5 V. It is also shown to be successful for discovering rare and small near-earth asteroids. Possibilities with cameras on spacecraft that pass through the asteroid belt are described.

Gehrels, Tom↗

Validation of Earth Radiation Budget Experiment scanning radiometer data inversion procedures

Validation techniques were implemented in the inversion of scanner radiometer data to assess the accuracy of the top of atmosphere radiant fluxes. An evaluation of SW radiant flux standard deviations for the same scene type shows that they contribute about 6.0 W/sq m for viewing zenith angles less than 55 deg and can reach values of up to 17.6 W/sq m for larger zenith angles in the backward scanning position. Three-channel intercomparison results, presented as color graphic displays and histograms, effectively validate the radiance measurements and the spectral factors. Along-track data were used to validate limb-darkening models and showed good agreement with current ERBE models. These validation techniques were found to be very effective in assessing the quality of the radiant fluxes generated by the ERBE inversion algorithm.

Manalo, Natividad D.↗

Microstress contrast in scanning electron acoustic microscopy of ceramics

A mathematical model of image contrast in scanning electron acoustic microscopy (SEAM) due to the effect of residual stresses in materials is presented. It is found that in regions near the ends of the radial cracks induced by Vickers indentation the SEAM micrographs reveal a rather large variation of the acoustic output signal.

Cantrell, John H.↗

Precise laser frequency scanning using frequency-synthesized optical frequency sidebands - Application to isotope shifts and hyperfine structure of mercury

Based on an efficient broadband electrooptic modulator producing RF optical sidebands locked to a stable cavity, a tunable dye laser can be scanned under computer control with frequency-synthesizer precision. Cavity drift is suppressed in software by using a strong feature in the spectrum for stabilization. Mercury isotope shifts are measured with a reproducibility of about 50 kHz. This accuracy of about 1/300 of the linewidth illustrates the power of the technique. Derived hyperfine-structure constants are compared with previous atomic-beam data.

Rayman, M. D.↗

Tensile strain measurements of ceramic fibers using scanning laser acoustic microscopy

A noncontacting technique using scanning laser acoustic microscopy for making in situ tensile strain measurements of small diameter fibers was implemented for the tensile strain analysis of individual Nicalon SiC fibers (nominal diameter 15 microns). Stress vs strain curves for the fibers were plotted from the experimental data. The mean elastic modulus of the fibers was determined to be 185.3 GPa. Similar measurements were made for Carborundum SiC fibers (nominal diameter 28 microns) and Saphikon sapphire fibers (nominal diameter 140 microns).

Kent, Renee M.↗

Scanning For Hotspots In Lamp Filaments

Scanning photometer designed for use in investigation of failures of incandescent lamp filaments. Maps brightness as function of position along each filament to identify bright (hot) spots, occurring at notches and signifying incipient breaks or rewelds. Also used to measure nonuniformity in outputs of such linear devices as light-emitting diodes, and to measure diffraction patterns of lenses.

Powers, Charles E.↗

Conically Scanned Holographic LIDAR Telescope

Holographic LIDAR telescope includes holographic disk, rotation of which sweeps collimated, monochromatic beam of light from laser through conical scan. Holographic disk diffracts light scattered back from target volume or area to focal point located at stationary photomultiplier detector. Two conical baffles prevent stray light from reaching detector.

Schwemmer, Geary↗

Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) PARM tape user's guide

The Scanning Multichannel Microwave Radiometer (SMMR) instrument, onboard the Nimbus-7 spacecraft, collected data from Oct. 1978 until Jun. 1986. The data were processed to physical parameter level products. Geophysical parameters retrieved include the following: sea-surface temperatures, sea-surface windspeed, total column water vapor, and sea-ice parameters. These products are stored on PARM-LO, PARM-SS, and PARM-30 tapes. The geophysical parameter retrieval algorithms and the quality of these products are described for the period between Nov. 1978 and Oct 1985. Additionally, data formats and data availability are included.

Han, D.↗

Output data formatter for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Output Data Formatter (ODF) for the ESTAR (Electronically Scanned Thinned Array Radiometer) instrument has been designed and tested. It employs programmable logic devices to format and tag correlator data for transmission to Earth. After accepting 170 bits or correlator and error data in parallel, it appends an identification word and then serially passes the data to the Small Explorer Data System (SEDS) for transmission at a maximum rate of greater than 15 Mb/sec. Implemented with two reprogrammable field programmable gate arrays (FPGA's), each contained in a 132-pin plastic pin grid array (PGA) package, the design is cascadeable, fully testable, and low-power.

Chren, William A., Jr.↗

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

Walsh function generator for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Walsh Function Generator (WFG) for the ESTAR (Electronically Scanned Thinned Array Radiometer) instrument has been designed and tested. Implemented in a single Xilinx XC3020PC68-50 Field Programmable Gate Array (FPGA), it generates a user-programmable set of 32 consecutive Walsh Functions for noise cancellation in the analog circuitry of the Front-End Modules (FEM's). It is implemented in a 68-pin plastic leaded chip carrier (PLCC) package, is fully testable, and can be used for noise cancellation periods as small as 2 msec.

Chren, William A., Jr.↗

Recording and wear characteristics of 4 and 8 mm helical scan tapes

Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

Peter, Klaus J.↗

Ka-band feed arrays for spacecraft reflector antennas with limited scan capability - An overview

JPL and NASA are in the process of developing ground and spacecraft antenna systems at Ka-band frequencies for future deep space applications. The use of Ka-band (32-GHz) down communication will result in smaller ground and spacecraft antennas and associated equipment, and will provide larger bandwidths necessary for very high data rate communication and radio navigation. In this article, the use of a small phased array as a feed for a reflector antenna system with limited scan capability is addressed. Different feed and antenna configurations, as well as array architectures, are examined. Some theoretical an experimental parameters of a particular breadboard feed array developed by JPL and the University of Massachusetts are presented. Guidelines for the future direction of this effort are provided.

Jamnejad, V.↗

Spectral radiation analyses of the GOES solar illuminated hexagonal cell scan mirror back

A ray tracing analytical tool has been developed for the simulation of spectral radiation exchange in complex systems. Algorithms are used to account for heat source spectral energy, surface directional radiation properties, and surface spectral absorptivity properties. This tool has been used to calculate the effective solar absorptivity of the geostationary operational environmental satellites (GOES) scan mirror in the calibration position. The development and design of Sounder and Imager instruments on board GOES is reviewed and the problem of calculating the effective solar absorptivity associated with the GOES hexagonal cell configuration is presented. The analytical methodology based on the Monte Carlo ray tracing technique is described and results are presented and verified by experimental measurements for selected solar incidence angles.

Fantano, Louis G.↗

Scanning mirror design considerations for a geostationary spaceborne radiometer

This paper will address the design considerations and challenges for a radiometer scanning mirror in a Geostationary (GEO) orbit. With increasingly demanding imaging requirements, mirror designs that are insensitive to the harsh thermal environment will be required. The compatibility of various mirror designs for a precision radiometer will be examined and discussed. The design solutions considered will include material, geometry and thermal design tradeoffs.

Hookman, R. A.↗

Remote sensing of aerosols with the Earth Observing Scanning Polarimeter

Tropospheric aerosols have potential climate forcing roles through both the direct effect on solar radiation scattered and absorbed and the indirect effect as condensation nuclei for cloud particles. Present capabilities for characterizing the global aerosol climatology are limited by the existing satellite remote sensing measurements, making a quantitative determination of the climate forcing effects of aerosols rather difficult and uncertain. The Earth Observing Scanning Polarimeter (EOSP) instrument under consideration for Earth Observing System (EOS) mission platforms and for a proposed Climsat Earth Probe mission is intended to provide global mapping with multispectral photopolarimetry, which can be exploited for the more pronounced aerosol signature in the polarization of the scattered light as compared to the radiance. We describe the essential features and performance specifications of the EOSP instrument and discuss approaches for retrieving tropospheric aerosol properties from multispectral photopolarimetry.

Travis, Larry D.↗

Mapping crystal defects with a digital scanning ultramicroscope

A computer controlled scanning ultramicroscope has been built to assist in the characterization of transparent crystals. The device measures the scattering of a focused He-Ne laser beam by crystalline defects. As an XYZ translation table moves the crystal under the ultramicroscope, the scattered light is measured by a photodetector whose output is digitized and recorded. From this data, contour maps or three dimensional perspective plots of the scattering regions of the crystal can be generated to assist in finding patterns of defects which might be correlated with perturbations in the growth process. The verified resolution of the present instrument is about 1 micrometer, which is limited by the minimum step of the stepper-motor driven translation stages, optical diffraction effects and the sensitivity of the detector at the laser light frequency. The instrument was used to build a database of defects patterns in commercial laboratory grown triglycine sulphate (TGS) crystals, and to map defects in a TGS crystal grown from aqueous solution during the flight of Spacelab 3. This crystal shows indications of a reduction both in the generation of defects at the seed-new growth interface and in their propagation into the new crystal.

Springer, J. M.↗