Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

912 records · Page 51

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Expected Performance of the GLAST Burst Monitor

The GLAST Burst Monitor (GBM) will enhance LAT observations of GRBs by extending the spectral coverage from the LAT threshold down to {approx}8 keV, and will provide a trigger for re-orienting the spacecraft to observe delayed emission from selected bursts outside the LAT field of view. GBM consists of twelve NaI scintillation detectors operating in the 8 keV to 1 MeV energy range and two BGO scintillation detectors operating in the 150 keV to 30 MeV energy range. Detector resolution, effective area, and angular response have been determined by calibrations. Analyses indicate that the on-board burst threshold will be {approx}0.7 photons cm{sup -2}s{sup -1} and the on-board burst localization accuracy will typically be better than 8 deg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the GRB Monitor for the CALET Experiment

The CALET mission is a Japanese-led effort involving candidate experiments on the International Space Station, planned for launch in 2013. The CALET main detector is a pair conversion telescope which is dedicated to observing high energy electrons and gamma-rays in the GeV-TeV range. CALET can observe gamma-ray bursts over an unprecedented 9 decade energy range from {approx}keV to {approx}TeV with a combination of a gamma-ray burst monitor (GBM) with low energy coverage. GBM is now designed as multiple scintillators made of BGO and LaBr{sub 3}(Ce) scintillators. The prototype LaBr{sub 3}(Ce) crystal with 3 inch diameter and 0.5 inch thickness displays a very good performance: 2.9{+-}0.1% FWHM energy resolution at 662 keV and 4 keV lower energy threshold. Furthermore, degradations in performance by the anticipated proton irradiation in the orbit are not significant. Results on proton-induced background are also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

On-Orbit Performance of the Fermi Gamma-Ray Burst Monitoi

The Fermi Gamma Ray Burst Monitor (GBM) enhances the science return from the Fermi mission by providing observations of GRBs in the energy range 8 keV to 40 MeV, thereby extending GRB spectra three decades below the Large Area Telescope (LAT) threshold of {approx}20 MeV. GBM employs twelve sodium iodide scintillation detectors and two bismuth germinate scintillation detectors to observe the full unocculted sky. The flight software localizes GRBs and can generate a request to autonomously repoint the spacecraft to place a burst within the LAT field of view. GBM has a trigger threshold of 0.74 photons-cm{sup -2}-s{sup -1} and triggers on {approx}260 bursts per year, as well as a variety of other gamma-ray transients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for muon signal from dark matter annihilations in the Sun with the Baksan Underground Scintillator Telescope for 24.12 years

We present a new dataset analysis of the neutrino experiment at the Baksan Underground Scintillator Telescope with muon energy threshold about 1 GeV for the longest exposure time toward the Sun. In search for a signal from self-annihilations of dark matter particles in the center of the Sun we use an updated sample of upward through-going muons for 24.12 years of live time. No observable excess has been found in measured muons relative to expected background from neutrinos of atmospheric origin. We present an improved data analysis procedure and describe it in detail. We set the 90% C.L. new upper limits on expected neutrino and muon fluxes from dark matter annihilations in the Sun, on the corresponding annihilation rates and cross sections of their elastic scattering off proton.

79 ASTRONOMY AND ASTROPHYSICS↗

Proton recoil telescope based on diamond detectors for measurement of fusion neutrons

Diamonds are very promising candidates for the neutron diagnostics in harsh environments such as fusion reactor. In the first place this is because of their radiation hardness, exceeding that of Silicon by an order of magnitude. Also, in comparison to the standard on-line neutron diagnostics (fission chambers, silicon based detectors, scintillators), diamonds are less sensitive to γ rays, which represent a huge background in fusion devices. Finally, their low leakage current at high temperature suppresses the detector intrinsic noise. In this talk a CVD diamond based detector has been proposed for the measurement of the 14 MeV neutrons from D-T fusion reaction. The detector was arranged in a proton recoil telescope configuration, featuring a plastic converter in front of the sensitive volume in order to induce the (n,p) reaction. The segmentation of the sensitive volume, achieved by using two crystals, allowed to perform measurements in coincidence, which suppressed the neutron elastic scattering background. A preliminary prototype was assembled and tested at FNG (Frascati Neutron Generator, ENEA), showing promising results regarding efficiency and energy resolution. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermi GBM: Main detector-level calibration results

One of the scientific objectives of NASA's Fermi Gamma-ray Space Telescope is the study of Gamma-Ray Bursts (GRBs). The Fermi Gamma-Ray Burst Monitor (GBM) was designed to detect and localize bursts for the Fermi mission. By means of an array of 12 NaI(Tl)(8 keV to 1 MeV) and two BGO (0.2 to 40 MeV) scintillation detectors, GBM extends the energy range (20 MeV to >300 GeV) of Fermi's main instrument, the Large Area Telescope (LAT), into the traditional range of current GRB databases. The physical detector response of the GBM instrument to GRBs is determined with the help of Monte Carlo simulations, which are supported and verified by on-ground individual detector calibration measurements. We present the principal instrument properties, which have been determined as a function of energy and angle, including the channel-energy relation, the energy resolution and the effective area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surrogate Measurements of Actinide (n,2n) Cross Sections with NeutronSTARS

Directly measuring (n,2n) cross sections on short-lived actinides presents a number of experimental challenges. The surrogate reaction technique is an experimental method for measuring cross sections on short-­lived isotopes, and it provides a unique solution for measuring (n,2n) cross sections. This technique involves measuring a charged-­particle reaction cross section, where the reaction populates the same compound nucleus as the reaction of interest. To perform these surrogate (n,2n) cross section measurements, a silicon telescope array has been placed along a beam line at the Texas A&M University Cyclotron Institute, which is surrounded by a large tank of gadolinium-doped liquid scintillator, which acts as a neutron detector. The combination of the charge-particle and neutron-detector arrays is referred to as NeutronSTARS. In the analysis procedure for calculating the (n,2n) cross section, the neutron detection efficiency and time structure plays an important role. Due to the lack of availability of isotropic, mono-energetic neutron sources, modeling is an important component in establishing this efficiency and time structure. This report describes the NeutronSTARS array, which was designed and commissioned during this project. It also describes the surrogate reaction technique, specifically referencing a 235 U(n,2n) commissioning measurement that was fielded during the past year. Advanced multiplicity analysis techniques have been developed for this work, which should allow for efficient analysis of 241 Pu(n,2n) and 239 Pu(n,2n) cross section measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interim Report on the Optimization and Feasibility Studies for the Neutron Detection without Helium-3 Project

This report details the results of the work accomplished for the „Neutron Detection without Helium-3‟ project during the 2011 fiscal year. The primary focus of the project during this year was to develop models using alternatives to helium-3 to investigate the possibilities and optimizations for multiplicity counters in safeguards applications by computer simulations. The multiplicity counter with significant capability, the Epithermal Neutron Multiplicity Counter (ENMC), was used as the baseline requirement for alternative technologies, which, if a suitable alternative can be found, should also satisfy systems with less stringent requirements, including coincidence counters. The project is in collaboration with Los Alamos National Laboratory (LANL), and the baseline model of the ENMC that had been developed at LANL with helium-3 as the detector material was used as a starting point. The model was modified to support optimization investigations, and verified with the helium-3 base material. The model was then modified to incorporate boron-trifluoride (BF3) gas, which can be used as a proportional gas similar to helium-3. The BF3 gas however, cannot be operated at very high pressure, and therefore optimization were performed with lower pressures and involved changing the tube size and number. The simulation of this model is very similar in approach to the model with helium-3 where the simulation ends when the neutron is captured in the boron. The reaction products are easily detected in the proportional gas, and the simulation results of counting the number of reactions matches well with experimental data. Next, the tubes were replaced with boron-lined proportional tubes, where the neutron capture material is a thin boron lining inside the tube wall, and which use standard proportional counting gas. For this alternative, the simulation needs to extend beyond the neutron capture, and track the reaction products, which must exit the boron-lining into the counting gas. The reaction products do not always end up in the counting gas, depending on the boron-lining thickness and neutron capture depth. Methods to track the reaction products have been recently implemented into MCNPX and were verified by using several different approaches. The tube number and size were also varied for the boron-lined case. Finally, work has started on a model of an alternative using lithium-6, another material with a high cross-section for thermal neutron capture. The most promising approach is with lithium fluoride in a zinc sulfide (silver activated) scintillator medium. The neutron is captured in the lithium, and the reaction products trigger scintillation light in the zinc sulfide, which is subsequently detected by photo-multipliers by the use of light guides or fibers. The simulations were performed with the focus on determining the efficiency, which is critical when detecting 2 or 3 neutrons in coincidence, as well as the die-away time, which is a measure of the time required to capture neutrons in the system. The die away time is related to the coincident time gate needed for the system which drives the accidental coincident rate, the primary background or noise in this type of measurement. The usual figure of merit for coincidence type systems, the efficiency squared divided by the die-away time, was calculated for each variation simulated.

helium-3 alternatives↗

Validation of the Fast-Neutron Multiplicity Expressions for Fissile Mass Estimation

Neutron multiplicity analysis is a non-destructive assay technique that involves measurement of the multiplets of neutrons that are emitted from fission of fissile material. Typically, multiplicity analysis is conducted by means of a neutron multiplicity counting (NMC) system that uses capture-based thermal-neutron detectors (e.g., 3He-gas detectors). To relieve the reliance on such detectors, we have developed a fast-neutron multiplicity counting (FNMC) system that uses scatter-based, organic scintillators to directly detect the fast fission neutrons emitted from the sample. One challenge with FNMC systems, however, is that they are prone to effects of neutron cross-talk, where a single neutron may scatter and cause more than one detection event. This leads to an overestimate of the fission rate (F) and inaccurate estimation of other sample parameters such as the leakage multiplication (M) and the alpha-ratio (a) when using the traditional capture-based NMC equations. We have formulated fully generalized multiplicity expressions that account for cross-talk effects for any arbitrary order N. The validity of these expressions were verified with MCNPX-PoliMi simulations and experimental measurements; this paper will present the validation of the proposed generalized multiplicity expressions. Californium-252 and Pu metal plates were measured using the FNMC system and the data was used for neutron multiplicity analysis to estimate sample parameters F, M, and a. We demonstrate that accounting for neutron cross-talk effects of order N = 2 and 3 improves the accuracy of the estimated sample parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximum Likelihood Source Localization Using Elpasolite as a Dual Gamma Neutron Directional Detector

The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.

maximum likelihood, radiation detectors, neutron d↗

CHERENCUBE: Concept definition and implementation challenges of a Cherenkov-based detector block for PET

Purpose: A new concept for a depth-of-interaction (DOI) capable time-of-flight (TOF) PET detector is defined, based only on the detection of Cherenkov photons. The proposed “CHERENCUBE” consists of a cubic Cherenkov radiator with position-sensitive photodetectors covering each crystal face. By means of the spatial distribution of the detected photons and their time of arrival, the point of interaction of the gamma-ray in the crystal can be determined. This study analyzes through theoretical calculations and Monte Carlo simulations the potential advantages of the concept toward reaching a Cherenkov-only detector for TOF-PET with DOI capability. Furthermore, an algorithm for the DOI estimation is presented and the requirements for a practical implementation of the proposed concept are defined. Methods: The Monte Carlo simulations consisted of a cubic crystal with one photodetector coupled to each one of the faces of the cube. The sensitive area of the detector matched exactly the crystal size, which was varied in 1 mm steps between 1 × 1 × 1 mm{sup 3} and 10 × 10 × 10 mm{sup 3}. For each size, five independent simulations of ten thousand 511 keV gamma-rays were triggered at a fixed distance of 10 mm. The crystal chosen was PbWO{sub 4}. Its scintillation properties were simulated, but only Cherenkov photons were analyzed. Photodetectors were simulated having perfect photodetection efficiency and infinite time resolution. For every generated particle, the analysis considered its creation process, parent and daughter particles, energy, origin coordinates, trajectory, and time and position of detection. The DOI determination is based on the distribution of the emission time of all photons per event. These values are calculated as a function of the coordinates of detection and origin for every photon. The common origin is estimated by finding the distribution with the most similar emission time-points. Results: Detection efficiency increases with crystal size from 8.2% (1 × 1 × 1 mm{sup 3}) to 58.6% (10 × 10 × 10 mm{sup 3}) and decreases applying a photon detection threshold of 5/10/20 photons to 6.3%/4.3%/0.7% and 49.3%/30.4%/2.8%, respectively. The detection rate in the six photodetectors is uniform due to the nearly isotropic cone emission. Most cones originated after a photoelectric effect interaction, with two dominating peaks for the kinetic energy of the electron at 422.99 and 441.47 keV. The detection distance between same-event photons defines the spatial resolution of the detector required for individual photon recognition, with 20% of the detected photons having their closest neighbor within a distance of 5% of the length of the cube. Same-event photons are detected within a time window whose width is determined by the crystal size, with values of 30 and 150 ps for a 1 × 1 × 1 mm{sup 3} and a 10 × 10 × 10 mm{sup 3} cube, respectively. The DOI reconstruction has an accuracy of approximately 23% of the length of the cube, with an average value of 2.2 mm for a 10 × 10 × 10 mm{sup 3} CHERENCUBE. Conclusions: The proposed concept requires a detector with high photodetection efficiency. The structure of the sensitive surface of the detector should be a two dimensional array of microcells, able to provide individual detection coordinates and time stamps. The microcell size determines the ability to recognize individual photons, influencing detection efficiency. The 3D DOI recognition relies on the accuracy of the time stamps and detection coordinates, without the need for a recognition of the projected patterns of photons. The refractive index of the material defines a detector intrinsic energy-based rejection of scattered PET events at the cost of reduced sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗