Enhanced Pool Boiling of Low-Pressure Refrigerants on Round Tubes- An Experimental Evaluation

Pool boiling heat transfer is one of the most effective heat transfer methos and crucial for several energy conversion processes such as electronic cooling, steam generation, water purification and thermal management. Enhancing boiling heat transfer around the tubes enables higher heat flux, which can improve the efficiency and lead to compact heat exchangers. Delaying the onset of critical heat flux (CHF) allows for higher CHFs and protects equipment during anomalous transient conditions. Growing interest in process intensification and delayed CHF has motivated the current study. An experimental approach has been deployed to investigate a potential technique to enhance the pool boiling performance around small diameter tubes by open cell metal foams. The findings for nucleate pool boiling of Novec HFE 7000 on the externally enhanced and smooth tubes are reported. The enhanced tube comprised of compressed aluminum foam brazed around. All the samples were horizontally oriented, and the experiments were performed under ambient pressure conditions. The heat transfer measurements for the smooth tubes were compared with several existing correlations and established the baseline. The preliminary results showed that the aluminum foam effectively enhanced the heat transfer coefficient and delayed the onset of critical heat flux. In addition, the pool boiling process around the round tube sample was visualized from both side and front views to comprehend the heat transfer mechanisms underlying substantial enhancement observed during experiments.

Yang, Cheng-Min↗

Systems and methods for superconducting quantum refrigeration

A heat transfer device and method are disclosed. The device includes a working region (i.e., working substance) made from a first superconducting material having a superconducting state and a normal state when magnetized. The first superconducting material has a first energy gap while in the superconducting state. A substrate (i.e., cold reservoir) is connected to the working region at a first tunnel junction. The substrate may be a metallic substrate. A heat sink (i.e., hot reservoir) is connected to the working region at a second tunnel junction. The heat sink is made from a second superconducting material having a second energy gap that is larger than the first energy gap. In a particular example, the heat transfer device includes a metallic substrate is made from Copper, a working region made from Tantalum, a heat sink made from Niobium, and the first and second tunnel junctions are made from Tantalum Oxide.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solar-Powered Aerogel-Based Adsorptive Air Conditioning

The DOE estimates the total primary energy consumption for commercial buildings was 10.72 quadrillion BTU (quads) in 1983, compared with 14.74 quads for the residential sector. According to the DOE Building Technologies Program, 40–60% of the energy used in U.S. commercial (and residential) buildings is for HVAC, creating massive potential for energy savings with a system that could cut cooling energy use by at least 30–60%. Initial vertical segments in the commercial building market include government and commercial office buildings; government facilities such as prisons, military bases, and schools; hotels and resorts; farming, wineries and other rural facilities; and general light industrial offices (e.g., printers and clothing makers). We propose a solar powered aerogel-based adsorption cooling system, including the completion and testing of a working prototype at an existing HVAC testing facility and technology-maturation testing at an existing beta-testing site. In the cooling system, solar radiation is focused by solar collectors onto on bed, which contains ultra high surface area aerogel. Heating causes thermal desorption of a refrigerant previously adsorbed into the aerogel’s pores. Refrigerant desorption increases the gas-phase pressure in the pores, thereby forcing the gaseous refrigerant to flow out of the first irradiated bed (Bed A) and through a two-stage condenser. In the condenser, heat is first removed from the hot gaseous refrigerant by a stream of water that eventually flows into a hot water heater and storage system. The refrigerant is then further cooled by chilled refrigerant leaving the evaporator after vaporization. After passing through the two-stage condenser, the gaseous refrigerant undergoes expansion through an expansion valve. A portion of the refrigerant condenses in the evaporator, while some of the refrigerant is flashed and exits the evaporator. The evaporator absorbs heat from the area being cooled, which results in further vaporization of the refrigerant. The cool, vaporized refrigerant leaves the evaporator, passing through tubes in the shell-and-tube heat exchanger comprising the second stage of the two-stage condenser. After leaving the tube side of this heat exchanger, it flows to the second bed of aerogel (Bed B), which is maintained at a relatively low temperature by water entering the building and destined for the hot water tank. During the first cycle, most of the refrigerant adsorbs on Bed B. When the refrigeration cycle is reversed, the refrigerant is thermally desorbed from Bed B, and adsorbed on the cooler Bed A. As the cycling rate increases, the quantity of adsorption media, the system size, and the associated cost becomes smaller. It appears that an optimized system can meet targeted performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a Water Based, Critical Flow, Non-Vapor Compression cooling Cycle

Expansion of a high-pressure liquid refrigerant through the use of a thermostatic expansion valve or other device is commonplace in vapor-compression cycles to regulate the quality and flow rate of the refrigerant entering the evaporator. In vapor-compression systems, as the condensed refrigerant undergoes this expansion, its pressure and temperature drop, and part of the liquid evaporates. We (researchers at Kansas State University) are developing a cooling cycle that instead pumps a high-pressure refrigerant through a supersonic converging-diverging nozzle. As the liquid refrigerant passes through the nozzle, its velocity reaches supersonic (or critical-flow) conditions, substantially decreasing the refrigerant’s pressure. This sharp pressure change vaporizes some of the refrigerant and absorbs heat from the surrounding conditions during this phase change. Due to the design of the nozzle, a shockwave trips the supersonic two-phase refrigerant back to the starting conditions, condensing the remaining vapor. The critical-flow refrigeration cycle would provide space cooling, similar to a chiller, by running a secondary fluid such as water or glycol over one or more nozzles. Rather than utilizing a compressor to raise the pressure of the refrigerant, as in a vapor-cycle system, the critical-flow cycle utilizes a high-pressure pump to drive refrigerant liquid through the cooling cycle. Additionally, the design of the nozzle can be tailored for a given refrigerant, such that environmentally benign substances can act as the working fluid. This refrigeration cycle is still in early-stage development with prototype development several years away. The complex multi-phase flow at supersonic conditions presents numerous challenges to fully understanding and modeling the cycle. With the support of DOE and venture-capital investors, initial research was conducted at PAX Streamline, and later, at Caitin. We (researchers at Kansas State University) have continued development of the cycle and have gained an in-depth understanding of the governing fundamental knowledge, based on the laws of physics and thermodynamics and verified with our testing results. Through this research, we are identifying optimal working fluid and operating conditions to eventually demonstrate the core technology for space cooling or other applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Total Thermal Management of Battery Electric Vehicles (BEVs)

The key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10°C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor) (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.

Chowdhury, Sourav↗

Connected Loads – Grid Connected Appliances: Deployment IoT Solution for Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 ( or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50– 52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostics (AFDDs) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. This study reviews existing IoT solutions developed for building energy– related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

Air-to-fluid heat exchangers (HXs) play a critical role as the main heat transfer component in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems. However, their airside thermal resistance significantly inhibits their overall performance. Furthermore, these HXs must be continually more compact to meet the latest refrigerant charge limits to reduce emissions. Recent literature suggests that traditional HX geometries (e.g., round or flat tubes with fins), have reached their limits, and more sophisticated shape- and topology-optimized designs are required to achieve the next jump in performance. This research sheds light on the next generation of air-to-refrigerant HXs and aims to address several practical issues to commercialization such as novelty challenges (improved performance for significant charge reduction; modeling expertise & time investment), manufacturing challenges (non-round tube manufacturing; tube-header integration; product qualification, e.g., burst pressure testing, extreme operational environment, etc.), and operational challenges (flow maldistribution, fouling & wetting, noise & vibration). For example, a >20% improvement on one (or more) HX-level performance metrics (e.g., envelope volume, airside pressure drop, face area, capacity, refrigerant charge, weight, cost, etc.) must be achieved before a HX design is considered for commercialization. We present a new, comprehensive and experimentally validated air-to-refrigerant HX optimization framework with simultaneous thermal-hydraulic performance and mechanical strength considerations for novel, non-round, shape- and topology-optimized tubes capable of optimizing single and two-phase HX designs for any refrigerant choice and performance requirement with significant engineering time savings compared to conventional design practices. The framework was exercised for a wide range of applications and refrigerants, resulting in HXs which achieved greater than 20% improved performance, 20% reductions in size, and 25% reductions in refrigerant charge. To enable non-round tube bundle use in next generation HVAC&R equipment, novel manufacturing techniques were investigated, including the development of conventional manufacturing methods for small diameter, non-round tubes and novel tube-header integration strategies. In total, ten HX prototypes were manufactured, nine using conventional methods directly attributed to this project and one using advanced additive manufacturing methods. The five-year manufacturing feasibility of the proposed HXs was found to have a good outlook. The non-round tube HX simulated performance was validated through comprehensive experimental testing, including nine in-house component-level tests, one independent component-level test at an industry partner laboratory, and in-house system-level tests of using a commercially-available, residential packaged A/C unit which was retrofitted with a non-round tube prototype HX. It was found that HX designs proposed by the new framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time with no manual design changes, eliminating the need for time-consuming and expensive prototyping efforts. This work will accelerate design and time to market for next generation HXs while simultaneously facilitating industry transition to new refrigerants at lower charge.

42 ENGINEERING↗

Propane Liquefaction with an Active Magnetic Regenerative Liquefier

Magnetic refrigeration is a cooling technique that uses the magnetocaloric e?ect (MCE). The active magnetic regenerator (AMR) cycle is a regenerative cycle that employs the MCE and consists of four steps: adiabatic magnetization with no heat transfer gas flow; heat transfer gas flow at constant high field; demagnetization with no heat transfer gas flow; and heat transfer gas flow at constant low field. The first heat transfer gas cold-to-hot flow step rejects heat from the magnetized regenerator to a hot sink and the second reverse heat transfer gas hot-to-cold flow step add heat from a cold source into the demagnetized regenerator. Our primary research and development objective is to use the MCE for more efficient liquefaction of much colder cryogens, to help identify problems of effective coupling of cold heat transfer gas of a single-stage reciprocating magnetic refrigerator to a process gas, we have used a single-stage active magnetic regenerative refrigerator (AMRR) with Gd refrigerant to liquefy pure propane gas at two different supply pressures. The high-purity propane was supplied from a small regulated lecture bottle at 295 K via a 1.6 mm o.d. stainless-steel tube into the helium-cooled coiled-fin tube heat exchanger at 49 psia or 27 psia, to liquefy propane at 262 K or 246 K, respectively. Propane liquefied until the small collection vessel and the coiled fin tube heat exchanger were filled at which the flow from the open lecture bottle stopped. The measured rate of liquefaction and the elapsed time for each case were measured and used to determine the volume of propane collected and the cooling power of the AMRR at the liquefaction temperatures. These cooling power results were compared to the cooling power results obtained from the curve of cool-down temperature vs. time data and agreement was excellent after the duty cycle of each cooling process was properly treated.

propane, liquefaction, active magnetic regenerator↗

REIMAGINING HEAT EXCHANGERS FOR NEXT GENERATION ENVIRONMENTAL SYSTEMS

Air-to-refrigerant heat exchangers (HXs) are essential components in space conditioning, refrigeration, and power systems, and recent efforts have focused on making these devices more compact, reducing refrigerant charge and lowering manufacturing costs. Historically, HX innovation has been limited by available computational resources, design tools, and manufacturing constraints. The best available technologies utilize tube-fin and micro- or macro-channel tubes with fins, which are not necessarily the optimal designs achievable with current technology. In this paper, we highlight the latest advancements in air-to-refrigerant HXs, specifically emphasizing innovations achieved through shape and topology optimization. A multi-scale design optimization approach is introduced, alongside similar methods in literature, which enable highly sophisticated shape-optimized tube designs with more than 50% reduction in size and 25% reduction in refrigerant charge, essential for A3 refrigerant charge limit compliance. The frameworks integrate traditional heat and mass transfer science with state-of-the-art machine learning, genetic algorithms, and adjoint algorithms to create novel designs. While many of these innovative designs may not be manufacturable using conventional methods, they allow us explore the boundaries of what is possible. These novel air-to-refrigerant HXs are key enablers for ultra-low-refrigerant charge heat pump and refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of high efficiency elastocaloric cooling with large Delta T using NiTi wires

Vapor compression (VC) is by far the most dominant technology for meeting all cooling and refrigeration needs around the world. It is a mature technology with the efficiency of modern compressors approaching the theoretical limit, but its environmental footprint remains a global problem. VC refrigerants such as hydrochloroflurocarbons (HCFCs) and hydrofluorocarbons (HFCs) are a significant source of green house gas emissions, and their global warming potential (GWP) is as high as 1000 times that of CO2 [Buildings Energy Data Book (Building Technologies Program, Department of Energy, 2009)]. There is an urgent need to develop an alternative high-efficiency cooling technology that is affordable and environmentally friendly [A. D. Little, Report For Office of Building Technology State and Community Programs, Department of Energy, 2001]. Here, we demonstrate that elastocaloric cooling (EC), a type of solid-state cooling mechanism based on the latent heat of reversible martensitic transformation, can have the coefficient of performance as high as 1 1, with a directly measured Delta T of 17 degrees C. The solid-state refrigerant of EC completely eliminates the use of any GWP refrigerants including HCFCs/HFCs. (C) 2012 American Institute. of Physics. [http://dx.doiorg/10.1063/1.4746257]

Cui, J↗

Performance Testing of Jefferson Lab 12 GeV Helium Screw Compressors

Oil injected screw compressors have essentially superseded all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, reliability, minimal vibration, and capability of handling helium's high heat of compression. At the present state of compressor system designs for helium refrigeration systems, typically two-thirds of the lost input power is due to the compression system. It is important to understand the isothermal and volumetric efficiencies of these machines to help properly design the compression system to match the refrigeration process. It is also important to identify those primary compressor skid exergetic loss mechanisms which may be reduced, thereby offering the possibility of significantly reducing the input power to helium refrigeration processes which are extremely energy intensive. This paper summarizes the results collected during the commissioning of the new compressor system for Jefferson Lab?s (JLab?s) 12 GeV upgrade. The compressor skid packages were designed by JLab and built to print by industry. They incorporate a number of modifications not typical of helium screw compressor packages and most importantly allow a very wide range of operation so that JLab?s patented Floating Pressure Process can be fully utilized. This paper also summarizes key features of the skid design that allow this process and facilitate the maintenance and reliability of these helium compressor systems.

Knudsen, P.↗