Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spectral emissivity measurements of land-surface materials and related radiative transfer simulations

Spectral radiance measurements have been made in the laboratory and in the field for deriving spectral emissivities of some land cover samples with a spectroradiometer and an auxiliary radiation source in the wavelength range 2.5-14.5 micrometers. A easy and quick four-step method (four steps to measure the sample and a diffuse reflecting plate surface under sunshine and shadowing conditions, respectively) has been used for simultaneous determination of surface temperature and emissivity. We emphasized in-situ measurements in combination with radiative transfer simulations, and an error analysis for basic assumptions in deriving spectral emissivity of land-surface samples from thermal infrared measurements.

Wan, Z.↗

Transition radiation as a source of cosmic X-rays.

It is shown that transition radiation generated during the passage of relativistic charged particles through interstellar grains can be an important source of cosmic X-rays. In order to account for recent X-ray observations below 300 eV by transition radiation, an energy density in interstellar space of about 10 eV per cu cm in 10 MeV electrons is required. This seems to rule out transition radiation as an important source of diffuse cosmic X-rays in any energy region.

Ramaty, R.↗

Efficient terahertz wave generation from GaP crystals pumped by chirp-controlled pulses from femtosecond photonic crystal fiber amplifier

A chirp-tunable femtosecond 10 W, 42 MHz photonic-crystal-fiber oscillator-amplifier system that is capable of delivering sub-60 fs light pulses at 1040 nm is used to demonstrate high-efficiency terahertz radiation generation via optical rectification in GaP crystals only a few millimeters in length. The optimization of the chirp of the fiber-laser pulses is shown to radically enhance the terahertz output, indicating one possible way to more efficiently use these extended nonlinear crystals in compact fiber-pumped terahertz radiation sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of an IXS imaging analyzer with an extended scattering source

A concept of an inelastic x-ray scattering (IXS) spectrograph with an imaging analyzer was proposed recently and discussed in a number of publications (see e.g. Ref.1). The imaging analyzer as proposed combines x-ray lenses with highly dispersive crystal optics. It allows conversion of the x-ray energy spectrum into a spatial image with very high energy resolution. However, the presented theoretical analysis of the spectrograph did not take into account details of the scattered radiation source, i.e. sample, and its impact on the spectrograph performance. Using numerical simulations we investigated the influence of the finite sample thickness, the scattering angle and the incident energy detuning on the analyzer image and the ultimate resolution.

47 OTHER INSTRUMENTATION↗

CMB power spectra induced by primordial cross-bispectra between metric perturbations and vector fields

We study temperature and polarization anisotropies of the cosmic microwave background (CMB) radiation sourced from primordial cross-bispectra between metric perturbations and vector fields, which are generated from the inflation model where an inflaton and a vector field are coupled. In case the vector field survives after the reheating, both the primordial scalar and tensor fluctuations can be enhanced by the anisotropic stress composed of the vector fields during radiation dominated era. We show that through this enhancement the primordial cross-bispectra generate not only CMB bispectra but also CMB power spectra. In general, we can expect such cross-bispectra produce the non-trivial mode-coupling signals between the scalar and tensor fluctuations. However, we explicitly show that such mode-coupling signals do not appear in CMB power spectra. Through the numerical analysis of the CMB scalar-mode power spectra, we find that although signals from these cross-bispectra are smaller than primary non-electromagnetic ones, these have some characteristic features such as negative auto-correlations of the temperature and polarization modes, respectively. On the other hand, signals from tensor modes are almost comparable to primary non-electromagnetic ones and hence the shape of observed B-mode spectrum may deviate from the prediction in the non-electromagnetic case. The above imprints may help us to judge the existence of the coupling between the scalar and vector fields in the early Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster – 12: Radiological assessment of the secondary barrier shielding for IMRT treatments delivered through patient inhomogeneities

Purpose: To assess the impact of radiation treatment delivery through patient inhomogeneities on the secondary barrier shielding requirements in IMRT treatments using Monte Carlo Simulations. Materials and Methods: Scatter factors were calculated at a distance of 1m from the center of a virtual phantom in Geant4.10.01. Phantom (30×30×30 cm{sup 3}) was inserted with lung (30×30×8 cm{sup 3}), stainless steel (5×5×5 cm{sup 3}) and aluminum (5×5×5 cm{sup 3}) to represent the inhomogeneities. Scatter factor was defined according to the NCRP-151 recommendations and was calculated for angles of 3° to 120° with respect to the beam’s central axis. A virtual radiation source, with energy sampled from a histogram representing 6 MV FFF beam, was used for irradiation with a field size of 15×15 cm{sup 2} and SSD of 100 cm. Results: Irradiation through the inhomogeneity affects the patient scattered dose. For high Z material inhomogeneities the scattered dose is reduced due to significant attenuation of the primary radiation. On the other hand if the inhomogeneity is a low Z material such as lung the scattered dose is higher by a maximum of 26%. The average increase in scatter factors for the lung phantom was 17% for angles between 3° and 63° compared to the homogeneous water phantom. Conclusions: In IMRT type treatments delivered through low density patient inhomogeneities (lung) the scattered dose increases significantly. Considering a large proportion of patients receiving radiation therapy for lung cancers the increase in the scattered dose should be incorporated in the shielding calculations for the secondary barriers.

60 APPLIED LIFE SCIENCES↗

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A metal-insulator-metal electron emitter based on a porous Al{sub 2}O{sub 3} film

A metal-insulator-metal electron emitter containing a sandwiched insulator layer composed of porous aluminum oxide Al{sub 2}O{sub 3} was fabricated. The electron emission characteristics of the electron emitter were investigated under vacuum and xenon. Treatment with H{sub 3}PO{sub 4} and rapid thermal oxidation increased the electric field inside the insulator and improved the quality of porous Al{sub 2}O{sub 3}, resulting in higher efficiency and less fluctuation of electron emission. The maximum current and efficiency of electron emission reached 1.05 mA/cm{sup 2} and 51.2%, respectively, under a pressure of 1.0×10{sup −4} Pa. In addition, electrons were injected into xenon and 147 nm vacuum ultraviolet emission was detected in xenon at a pressure of 5.0 × 10{sup 2 }Pa. This electron emitter has a great potential for use as an ultraviolet radiation source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermomechanical response of thickly tamped targets and diamond anvil cells under pulsed hard x-ray irradiation

In the laboratory study of extreme conditions of temperature and density, the exposure of matter to high intensity radiation sources has been of central importance. Here, we interrogate the performance of multi-layered targets in experiments involving high intensity, hard x-ray irradiation, motivated by the advent of extremely high brightness hard x-ray sources, such as free electron lasers and 4th-generation synchrotron facilities. Intense hard x-ray beams can deliver significant energy in targets having thick x-ray transparent layers (tampers) around samples of interest for the study of novel states of matter and materials’ dynamics. Heated-state lifetimes in such targets can approach the microsecond level, regardless of radiation pulse duration, enabling the exploration of conditions of local thermal and thermodynamic equilibrium at extreme temperature in solid density matter. The thermal and mechanical responses of such thick layered targets following x-ray heating, including hydrodynamic relaxation and heat flow on picosecond to millisecond timescales, are modeled using radiation hydrocode simulation, finite element analysis, and thermodynamic calculations. Assessing the potential for target survival over one or more exposures and resistance to damage arising from heating and resulting mechanical stresses, this study doubles as an investigation into the performance of diamond anvil high pressure cells under high x-ray fluences. Long used in conjunction with synchrotron x-ray radiation and high power optical lasers, the strong confinement afforded by such cells suggests novel applications at emerging high intensity x-ray facilities and new routes to studying thermodynamic equilibrium states of warm, very dense matter.

Meza-Galvez, J. (ORCID:000000032699849X)↗

SPITZER INFRARED SPECTROGRAPH DETECTION OF MOLECULAR HYDROGEN ROTATIONAL EMISSION TOWARDS TRANSLUCENT CLOUDS

Using the Infrared Spectrograph on board the Spitzer Space Telescope, we have detected emission in the S(0), S(1), and S(2) pure-rotational (v = 0-0) transitions of molecular hydrogen (H{sub 2}) toward six positions in two translucent high Galactic latitude clouds, DCld 300.2-16.9 and LDN 1780. The detection of these lines raises important questions regarding the physical conditions inside low-extinction clouds that are far from ultraviolet radiation sources. The ratio between the S(2) flux and the flux from polycyclic aromatic hydrocarbons (PAHs) at 7.9 {mu}m averages 0.007 for these six positions. This is a factor of about four higher than the same ratio measured toward the central regions of non-active Galaxies in the Spitzer Infrared Nearby Galaxies Survey. Thus, the environment of these translucent clouds is more efficient at producing rotationally excited H{sub 2} per PAH-exciting photon than the disks of entire galaxies. Excitation analysis finds that the S(1) and S(2) emitting regions are warm (T {approx}> 300 K), but comprise no more than 2% of the gas mass. We find that UV photons cannot be the sole source of excitation in these regions and suggest mechanical heating via shocks or turbulent dissipation as the dominant cause of the emission. The clouds are located on the outskirts of the Scorpius-Centaurus OB association and may be dissipating recent bursts of mechanical energy input from supernova explosions. We suggest that pockets of warm gas in diffuse or translucent clouds, integrated over the disks of galaxies, may represent a major source of all non-active galaxy H{sub 2} emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent advances in theoretical and numerical studies of wire array Z-pinch in the IAPCM

Fast Z-pinch has produced the most powerful X-ray radiation source in laboratory and also shows the possibility to drive inertial confinement fusion (ICF). Recent advances in wire-array Z-pinch researches at the Institute of Applied Physics and Computational Mathematics are presented in this paper. A typical wire array Z-pinch process has three phases: wire plasma formation and ablation, implosion and the MRT instability development, stagnation and radiation. A mass injection model with azimuthal modulation coefficient is used to describe the wire initiation, and the dynamics of ablated plasmas of wire-array Z-pinches in (r, θ) geometry is numerically studied. In the implosion phase, a two-dimensional(r, z) three temperature radiation MHD code MARED has been developed to investigate the development of the Magneto-Rayleigh-Taylor(MRT) instability. We also analyze the implosion modes of nested wire-array and find that the inner wire-array is hardly affected before the impaction of the outer wire-array. While the plasma accelerated to high speed in the implosion stage stagnates on the axis, abundant x-ray radiation is produced. The energy spectrum of the radiation and the production mechanism are investigated. The computational x-ray pulse shows a reasonable agreement with the experimental result. We also suggest that using alloyed wire-arrays can increase multi-keV K-shell yield by decreasing the opacity of K-shell lines. In addition, we use a detailed circuit model to study the energy coupling between the generator and the Z-pinch implosion. Recently, we are concentrating on the problems of Z-pinch driven ICF, such as dynamic hohlraum and capsule implosions. Our numerical investigations on the interaction of wire-array Z-pinches on foam convertors show qualitative agreements with experimental results on the “Qiangguang I” facility. An integrated two-dimensional simulation of dynamic hohlraum driven capsule implosion provides us the physical insights of wire-array plasma acceleration, shock generation and production, hohlraum formation, radiation ablation and fuel compression.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Do We Know How to Model Reionization?

I compare the power spectra of the radiation fields from two recent sets of fully-coupled simulations that model cosmic reionization: “Cosmic Reionization On Computers” (CROC) and “Thesan”. While both simulations have similar power spectra of the radiation sources, the power spectra of the photoionization rate are significantly different at the same values of cosmic time or the same values of the mean neutral hydrogen fraction. However, the power spectra of the photoionization rate can be matched at large scales for the two simulations when the matching snapshots are allowed to vary independently. I.e., on large scales, the clustering of the radiation field in two simulations evolves similarly, but the exact timing of this evolution is different in different simulations and is not parameterized by an easily interpretable physical quantity like the mean neutral fraction or the mean free path. On small scales, large differences are present and remain partially unexplained. Both CROC and Thesan use the Variable Eddington Tensor approximation for modeling radiative transfer, but adopt different closure relations (optically thin OTVET versus M1). The role of this key difference is tested by using smaller simulations with a new cosmological simulation code that implements both closure relations in a controlled environment (the same hydro, cooling, and gravity solvers and the star formation recipe). In these controlled tests, both the M1 closure and the OTVET ansatz follow the expected behavior from a simple analytical approximation, demonstrating that the differences in the 2-point function of the radiation field induced by the choice of the Eddington tensor are not dominant.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation sensitive area detection device and method

A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

Carter, Daniel C.↗

Shortening x-ray pulses for pump-probe experiments at synchrotrons

We implemented an experimental scheme for ultrafast x-ray diffraction at storage rings based on a laser-driven Bragg-switch that shortens the x-ray pulses emitted from an undulator. The increased time-resolution is demonstrated by observing changes of intensity, position and width of the diffraction peaks of a La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/SrTiO{sub 3} superlattice sample after optical excitation, i.e., by quantitatively measuring the propagation of an expansion wave through the sample. These experimental transients with timescales of 35 to 60 ps evidence a reduction of the x-ray pulse duration by a factor of two.

36 MATERIALS SCIENCE↗

Soft X-Ray Microscopy at HZB: Zone Plate Development and Imaging Using the Third Order of Diffraction

The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/{Delta}E = 10{sup 4}. An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to employ higher orders of diffraction of the zone plate objective. In this paper, we demonstrate that 11-nm lines and spaces of a multilayer test structure are clearly resolved by the x-ray microscope using the third order of diffraction of a zone plate objective with 20-nm outermost zone width. The disadvantage of high-order imaging is an about one order of magnitude lower diffraction efficiency of the used zone plates employed in the third order compared to the first order of diffraction. In addition, the measured background signal in the TXM images is no longer negligible. Therefore, we worked on the fabrication of zone plates with sub-20-nm outermost zone width to increase the spatial resolution in the first order of diffraction. A new high-resolution 100-keV e-beam lithography system from VISTEC, which was recently installed at the Helmholtz-Zentrum Berlin, makes these developments possible. Initial results on zone plates with an outermost zone width down to 15 nm exposed with the new e-beam system are presented. Furthermore, the contrast transfer function of the transmission x-ray microscope operating in partial coherence mode is measured by using the first and third diffraction order of the zone plate objective.

43 PARTICLE ACCELERATORS↗

Directional gamma sensing from covariance processing of inter-detector Compton crosstalk energy asymmetries

Energy asymmetry of inter-detector crosstalk from Compton scattering can be exploited to infer the direction to a gamma source. A covariance approach extracts the correlated crosstalk from data streams to estimate matched signals from Compton gammas split over two detectors. On a covariance map the signal appears as an asymmetric cross diagonal band with axes intercepts at the full photo-peak energy of the original gamma. The asymmetry of the crosstalk band can be processed to determine the direction to the radiation source. The technique does not require detector shadowing, masking, or coded apertures, thus sensitivity is not sacrificed to obtain the directional information. An angular precision of better than 1° of arc is possible, and processing of data streams can be done in real time with very modest computing hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional particle-in-cell simulations of laser-driven multiradiation sources based on double-layer targets

Double-layer targets (DLTs), made of a low-density foam on top of a solid substrate, can efficiently convert the energy of a high-intensity laser to provide sources of photons and protons. We investigate a 30-fs pulse with a peak intensity of I ~ 8.7×10 20 W/cm 2 and a peak power of ~120 TW interacting with a DLT using three-dimensional (3D) particle-in-cell simulations. We focus on providing quantitative results in full 3D geometry on the foam thickness dependence; on the competition between two photon-generating processes in DLTs, i.e., nonlinear inverse Compton scattering (NICS) and bremsstrahlung (BS); and on the acceleration of protons via enhanced target-normal sheath acceleration. Here, we discuss conversion efficiency, average energy, and angular distributions of such multiradiation sources. We find that NICS can prevail over BS if the DLT's substrate is thin enough (~µ⁢m) and that the optimal foam thickness that maximizes the conversion efficiency in NICS and BS photons and the proton cutoff energy, among those considered, is the same (15µ⁢m). These results show that DLTs constitute an excellent tool for developing relatively compact and optimized laser-driven multicomponent radiation sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗