Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Methods of measurement for semiconductor materials, process control, and devices

Activities directed toward the development of methods of measurement for semiconductor materials, process control, and devices are described. Accomplishments include the determination of the reasons for differences in measurements of transistor delay time, identification of an energy level model for gold-doped silicon, and the finding of evidence that it does not appear to be necessary for an ultrasonic bonding tool to grip the wire and move it across the substrate metallization to make the bond. Work is continuing on measurement of resistivity of semiconductor crystals; study of gold-doped silicon; development of the infrared response technique; evaluation of wire bonds and die attachment; measurement of thermal properties of semiconductor devices, delay time, and related carrier transport properties in junction devices, and noise properties of microwave diodes; and characterization of silicon nuclear radiation detectors.

Bullis, W. M.↗

Separation of surface and bulk minority-carrier lifetimes in silicon

A photoexcitation technique is suggested which is direct and convenient, requiring little special equipment. No change in the dimensions of the crystal sample is necessary. Although related to the technique of interposing a filter between the light source and the sample, it differs in that the filter is part of the crystal itself. Basically, one of the electrodes is split into two electrodes, one collecting charge from carriers excited in the bulk. This phenomenon in which the carriers follow very closely the electric field lines has been used in position-sensitive semiconductor radiation detectors (Norbeck and Carlson, 1963) but has not been applied to lifetime measurements. In a sense, the split electrode creates a sample without a surface.

Carroll, K. A.↗

The Identification of Scientific Programs to Utilize the Space Environment

A program to identify and develop ideas for scientific experimentation on the long duration exposure facility (LDEF) was completed. Four research proposals were developed: (1) Ultra pure germanium gamma ray radiation detectors in the space environment, intended to develop and demonstrate an X-ray and gamma-ray spectroscopy system incorporating a temperature cyclable high-purity germanium detector and diode heat pipe cryogenic system for cooling, (2) growth, morphogenesis and metabolism of plant embryos in the zero-gravity environment, to investigate if the space environment induces mutations in the embryogenic cells so that mutants of commercial significance with desirable attributes may be obtained, (3) effect of zero gravity on the growth and pathogenicity of selected zoopathic fungi. It is possible that new kinds of treatment for candidiasis, and tichophytosis could eventuate from the results of the proposed studies, and (4) importance of gravity to survival strategies of small animals. Gravitational effects may be direct or mediate the selection of genetic variants that are preadapted to weightlessness.

Kulacki, F. A.↗

Transition radiation effects in superconducting granules

The paper examines the use of a superheated superconducting suspension as a transition radiation detector of relativistic charged particles. The suspensions would also be used for detecting low-energy X-ray photons. The DESY experiment for developing such a superconducting detector has been carried out at a 7 GeV electron synchrotron. The detection is shown to be based on the recordable flipping of the state of a single superconducting grain.

Drukier, A. K.↗

Advanced Atmospheric Sounder and Imaging Radiometer (AASIR)

Design information for the Advanced Atmospheric Sounder and Imaging Radiometer is reported, which was developed to determine the configuration of a sensor for IR and visible imaging. The areas of technology reported include: systems design, optics, mechanics, electronics, detectors, radiative cooler, and radiometric calibration.

Source record↗

Survey of the Pioneer 10 and 11 Jupiter mission

After a description of the Pioneer 10 and 11 spacecraft, the following scientific experiments are discussed: Helium Vector Magnetometer, Fluxgate Magnetometer, Plasma Analyzer, Geiger Tube Telescope, Cosmic Ray Telescope, Trapped Radiation Detector, Ultraviolet Photometer, Imaging Photopolarimeter, Infrared Radiometer, Asteroid-Meteoroid Detector, and Meteoroid detector. Also reviewed are the mission profile and status.

Wolfe, J. H.↗

Regional variations in upper mantle compressional velocities beneath southern California 1. Post-shock temperatures: Their experimental determination, calculation, and implications, 2.

The compressional velocity within the upper mantle beneath Southern California is investigated through observations of the dependence of teleseismic P-delays at all stations of the array on the distance and azimuth to the event. The variation of residuals with azimuth was found to be as large as 1.3 sec at a single station; the delays were stable as a function of time, and no evidence was found for temporal velocity variations related to seismic activity in the area. These delays were used in the construction of models for the upper mantle P-velocity structure to depths of 150 km, both by ray tracing and inversion techniques. The models exhibit considerable lateral heterogeneity including a region of low velocity beneath the Imperial Valley, and regions of increased velocity beneath the Sierra Nevada and much of the Transverse Ranges. The development is described of a technique for the experimental determination of post-shock temperatures, and its application to several metals and silicates shocked to pressures in the range 5 to 30 GPa. The technique utilizes an infra-red radiation detector to determine the brightness temperature of the free surface of the sample after the shock wave has passed through it.

Raikes, S. A.↗

Post-shock temperatures in minerals

An experimental technique was developed for measuring post-shock temperatures in a wide variety of materials, including those of geophysical interest such as silicates. The technique uses an infrared radiation detector to determine the brightness temperature of samples shocked to pressures in the range 5 to approximately 30 GPa; in these experiments measurements were made in two wavelength ranges (4.5 to 5.75 microns and 7 to 14 microns). Reproducible results, with the temperatures in the two wavelength bands generally in excellent agreement, were obtained for aluminum-2024 (10.5 to 33 GPa, 125 to 260 C), stainless steel-304 (11.5 to 50 GPa, 80 to 350 C), crystalline quartz (5.0 to 21.5 GPa, 80 to 250 C), forsterite (7.5 to 28.0 GPa, approximately 30 to 160 C) and Bamble bronzite (6.0 to 26.0 GPa, approximately 30 to 225 C). It is concluded that release adiabat data should be used, wherever available, for calculations of residual temperature, and that adequate descriptions of the shock and release processes in minerals are more complex than generally assumed.

Raikes, S. A.↗

Performance analysis of a filtered wide field-of-view radiometer for earth radiation budget measurements

The proposed Earth Radiation Budget Satellite System (ERBSS) of the 1980's will include a wide field-of-view (WFOV) fixed axes earth radiator discriminator consisting of a shortwave channel and a total (unfiltered) channel. The broadband spectral isolation required for the shortwave channel is achieved by use of a hemispherical fused silica (Suprasil W) dome filter placed in front of a wire wound thermopile radiation detector. A description is presented of the thermal response of the single-fused silica dome filter in the ERBSS WFOV shortwave channel conceptual design and the impact of that response on the channel measurement. Results from design definition and performance analysis studies are included. Problems associated with achieving the desired levels of confidence in a high accuracy filtered, WFOV radiometer are discussed. Design approaches, ground calibration, and data reduction techniques which minimize measurement uncertainties are explained.

Cooper, J. E.↗

Nuclear Science Symposium, 26th and Symposium on Nuclear Power Systems, 11th, San Francisco, Calif., October 17-19, 1979, Proceedings

The paper covers the studies presented on nuclear science and nuclear power systems symposiums. The studies deal with nuclear radiation detectors, nuclear circuits and systems, space and medical instrumentation, as well as with environmental and reactor instrumentation. Data preprocessing and acquisition are discussed. Emphasis is placed on the engineered safety features of nuclear systems.

Kerns, C. R.↗

Develop real-time dosimetry concepts and instrumentation for long term missions

The development of a rugged portable dosimetry system, based on microdosimetry techniques, which will measure dose and evaluate dose equivalent in a mixed radiation field is described. Progress in the desired dosimetry system can be divided into three distinct areas: development of the radiation detector, and electron system are presented. The mathematical techniques required are investigated.

Braby, L. A.↗

Observations of effects from magnetospheric cusp movement during a solar proton event

Observations of a magnetospheric cusp motion event during a solar proton event are presented. The observations were made by a series of riometers and balloon-borne radiation detectors and conductivity probes near Sondre Stromfjord, Greenland. During the arrival of solar protons on August 19, 1979, the balloon-borne detectors recorded two rises and declines in nuclear gamma ray intensity accompanied by a marked softening in the photon spectrum. The observations are interpreted as a shift in detector position from the dayside of the magnetosphere to the polar cap resulting from an equatorward displacement or expansion of the polar cusp by 5 deg in 15 min with a southward turning of the IMF. Instruments on ISEE 3 confirm this interpretation, showing a southward turning of the IMF and a solar wind speed increase. Results imply a proton cutoff energy in the range 6-10 MeV at Sondre Strombjord prior to the cusp motion, and reflect the early effects of field line erosion.

Brown, R. R.↗

Advanced biostack experiment

The Advanced Biostack Experiment is described. The objectives are: (1) to confirm, complement, and enlarge the information obtained from the previous experiments by applying improved and advanced methods of localization and physical and biological evaluation, performing advanced experiments based on these data, and including additional biological specimens and additional radiation detectors; (2) to determine the biological importance of nuclear disintegration stars; (3) to determine the interference of HZE particle induced effects with those of other space flight factors (e.g., weightlessness); and (4) to determine the distribution of HZE particles and of disintegration stars at different locations inside the module and on the pallet.

Buecker, H.↗

Texas Symposium on Relativistic Astrophysics, 10th, Baltimore, MD, December 15-19, 1980, Proceedings

The present conference on relativistic astrophysics begins with consideration of such topics in the cosmology of the early universe as the implications of the neutrino rest mass, relic neutrino clustering, and the possibility of a matter-antimatter domain structure in the universe, and proceeds to the broader cosmological questions of the distances of extragalactic objects, the mass of the universe, and the dynamics of superclusters. Also considered are the cosmic microwave background, relativistic jet production and propagation in active galaxies, gravitational lenses, positron annihilation radiation from the galactic center region, supernova models, and the acceleration of cosmic rays by shock waves. Summaries are presented in closing, on workshops concerning such topics as gravitational radiation detectors, the UV cosmic ray background, pulsars, supernovae, active galaxies, and quasars.

Ramaty, R.↗

Cooling by Para-to-Ortho-Hydrogen Conversion

Catalyst speeds conversion, increasing capacity of solid hydrogen cooling system. In radial-flow catalytic converter, para-hydrogen is converted to equilibrium mixture of para-hydrogen and ortho-hydrogen as it passes through porous cylinder of catalyst. Addition of catalyst increases capacity of hydrogen sublimation cooling systems for radiation detectors.

Sherman, A.↗

Method and apparatus for precision control of radiometer

A radiometer controller of a radiation detector is provided with a calibration method and apparatus comprised of mounting all temperature sensitive elements of the controller in thermostatically controlled ovens during calibration and measurements, using a selected temperature that is above any which might be reached in the field. The instrument is calibrated in situ by adjusting heater power (EI) to the receptor cavity in the radiometer detector to a predetermined full scale level and is displayed by a meter.

Estey, R. S.↗

Investigation of the effects of long-duration exposure on active optical system components (S0050)

The effects of long duration space exposure on the relevant performance parameters of lasers, radiation detectors, and selected optical components, was determined. The results and implications of the measurements indicating real or suspected degradation mechanisms were evaluated and guidelines, based on these results, for selection and use of components for space electro-optical systems are established.

Blue, M. D.↗

The study of efficient low-power diffraction designs

Topics covered include the design and fabrication of: (1) a nuclear radiation monitor for use in measuring the radiation environment of the space shuttle payload bay (part of the Spacelab 2 payload; (2) a parallel plate ion chamber for measuring ionization loss by relativistic heavy ions and (3) ionization chambers and proportional chambers for the active radiation detector on Spacelab 1. An experiment to measure the response of ion chambers and Cerenkox counters to relativistic argon and iron atoms is also described.

Gregory, J. C.↗